My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2818 GRAND AVE 2020 Plans 2022-11-28
>
Address Records
>
GRAND AVE
>
2818
>
Plans
>
2818 GRAND AVE 2020 Plans 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 10:30:43 AM
Creation date
6/16/2022 8:55:32 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2818
Permit
B2004-010
Year
2020
Notes
REPLACE SIDING, TRIM, WINDOWS, SLIDING GLASS DOORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/fi <br />26 GA. PRE -FINISHED METAL f <br />UNLESS NOTED OTHERWISE �` •'�--------- 6"SAF OVER TOP OF <br />: i METAL, TYP. <br />SEALANT PER DESIGN DOCSTAPE <br />17 `17 <br />OR SEAL TO FLASING <br />(WRB NOT SHOWN FOR OR CLARHTY) <br />— OVERLAP <br />WRB/AIR BARRIER <br />~ f 1 PROVIDE PRE-FAB. <br />_, - " TRIM PER DESIGN DOCS <br />Copyright © 2018 All rights reserved. <br />J2 BuildingConsultants, Inc. <br />CORNER ASSEMBLIES TYP. <br />th Ave. W. 8425 44 <br />Mukl►teo WA 98275 <br />, <br />Tel425.774.5600 <br />WRAP ROLL AT ONE SIDE AROUND CORNER MIN.12" <br />w LAP COURSE ON ADJACENT WALL OVER FIRST <br />COURSE AND AROUND CORNER MIN.12" <br />f s <br />/ /- / <br />/� /� � <br />` <br />____________________•----_-___^_--_----------_----_____-_----.-----`---._._-___.._._.____ <br />- + ---� . DRAINAGE MEDIUM PER DESIGN DOCS TYP <br />, �' <br />, i <br />CREATING A WEAVE <br />f`• <br />I <br />i it <br />A <br />'fit <br />Fax 425.774.561 <br />c> <br />/" ,// ter` <br />� , <br />� / <br />fi <br />www.J2Consult nt <br />s.com <br />w START W/ 1/2 ROLL <br />of <br />10%MIN. SLOPE TO DRAIN <br />AIR BARRIER TAPE PER MFR <br />TAPE VERTICAL SEAMS <br />f <br />HEMMED DRIP EDGE, TYP. <br />SEALANT PER DESIGN DOCS <br />- - -T <br />--- WRB PER DESIGN DOCS; <br />The undersigned has provided building enclosure <br />y p judgement documents that in m professional 'ud ement are <br />appropriate to satisfy the requirements of RCW <br />DOUBLE BEAD OF BEDDING SEALANT <br />,✓ <br />OVERLAP WRB MIN.12" PAST CORNERS TYP. <br />EX. INSULATION & FRAMING <br />64.55.005 through 64.55.090 <br />ii <br />NOTE: REFER TO MANUFACTURER'S <br />INSTRUCTIONS FOR WRB/ AIR BARRIER INSTALL <br />• I� LAP JOINTS A MINIMUM OF 4" <br />APPLY 2 BEADS OF SEALANT <br />3l8 MIN. FOLDED END DAM <br />" <br />'� EX. SHEATHING <br />—�� ' <br />SIDING PER ELEVATIONS & DESIGN DOCS TYP. <br />12495 <br />REGISTERED <br />ARCHITECT <br />SAF OR PRE -STRIP OF WRB <br />_--- '" <br />` <br />WHERE SPECIFIED <br />s <br />I <br />-BRIAN FAJARDO <br />STATE OF WASHINGTON <br />! <br />PROVIDE PRE -FABRICATED <br />' <br />CORNER ASSEMBLIES TYP. <br />1 A7.1 <br />TYPICAL WRB APPLICATION <br />2 /A7.1 <br />TYPICAL FLASHING LAP <br />ID:60 <br />3 /A7.1 <br />TRIM AT OUTSIDE CORNER - TYPICAL SIDING <br />ID:59 <br />NOTES: <br />1. CONTRACTOR IS RESPONSIBLE <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />FOR FIELD VERIFICATION OF <br />SIZING AND QUANTITIES OF ALL <br />COMPONENTS. <br />KEEP EX. WRB <br />— <br />2. MOCK UP REVIEW OF ALL <br />SEALANT PER DESIGN DOCS WRAPPING PAST CORNER 18" MIN <br />SIDING PER DESIGN DOCS <br />- <br />:, . j <br />1 <br />EX. SIDING <br />EX. INSULATION & FRAMING TYP. <br />EXTERIOR ASSEMBLIES <br />REQUIRED BEFORE INSTALLATION. <br />DRAINAGE MEDIUM PER <br />I SIDING PER ELEVATIONS & DESIGN DOCS TYP. <br />�, ,_.. EX. SHEATHING TYP. <br />3. DRAWINGS ARE DIAGRAMMATIC <br />DESIGN DOCS — NEW TRIM PER DESIGN DOCS <br />EX. INSULATION & FRAMING TYP. <br />WRB <br />ONLY AND ARE NOT TO BE USED <br />FOR TAKE OFF QUANTITIES. <br />WRB PER DESIGN DOCS <br />:; EX. SHEATHING TYP. <br />° <br />Y <br />SEALANT PER DESIGN DOCS <br />.............. ---------------------------------- ---- -............................... <br />_. EX. INSIDE CORNER TRIM, R <br />REPLACE SEALANT IF <br />DAMAGED FAILING <br />}( # <br />— j I! NEW TRIM PER DESIGN DOCS <br />.. INSIDE CORNER TRIM PER DESIGN DOCS <br />a- .. SEALANT PER DESIGN DOCS <br />:� <br />OR <br />I SEALANT PER DESIGN DOCS <br />t �, <br />i 1 i f <br />V �, , s ;� <br />r <br />DRAINAGE MEDIUM PER DESIGN DOCS TYP. <br />Lu <br />> " <br />o WRB PER DESIGN DOCS; OVERLAP WRB 12 MIN. PAST CORNERS TYP. <br />DRAINAGE MEDIUM PER DESIGN DOCS TYP. <br />WRB PER DESIGN DOCS,12" MIN OVERLAP WITH EX. WRB <br />// <br />NEW SEALANT PER DESIGN DOCS <br />' <br />SIDING PER ELEVATIONS & DESIGN DOCS <br />Ffr <br />Revisions: <br />EX. WRB <br />�. <br />I '� <br />� e EX. INSULATION &FRAMING <br />i E i i EX. SHEATHING <br />'!------- -------------------------------------• <br />------------------------------------------------------------------------------------------------------------- <br />a <br />•........... _--- -- ---------------------------------------.._----------------------------------------- <br />i_ <br />y i <br />tE Date Description <br />EX. SIDING <br />f t ! 4 <br />t <br />$f <br />II } <br />0 <br />I F I <br />KEEP EX. WRB <br />--- <br />WRAPPING PAST CORNER 18" MIN <br />4 /A7.1 <br />TRIM AT OUTSIDE CORNER -NEW SIDING TO EXISTING SIDING <br />ID' <br />S /A7.1 <br />TRIM AT INSIDE CORNER - TYPICAL SIDING <br />ID:433 <br />6 /A7.1 <br />TRIM AT INSIDE CORNER - NEW SIDING TO EXISTING SIDING <br />1D <br />SCALE-: NTS <br />S E: NT <br />SCALE: : NTS <br />— SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />_ - EX. INSULATION & FRAMING TYP. <br />I <br />EX. SHEATHING TYP. <br />WRB FIELD LAYER LAPS METAL FLASHING APPLY SEALANT/TAPE AT <br />WRB TERMINATIONS <br />Project Title: <br />NAUTICA CONDOMINIUMS <br />EX. BRICK VENEER <br />''' <br />6 SAF OVER TOP OF METAL, TYP. <br />" <br />• <br />` <br />_ <br />- EX. SHEATHING <br />WRB PER DESIGN DOCS APPLY SEALANTffAPE AT WRB TERMINATIONS <br />: DRAINABLE INSECT PROOF STRIP <br />; ' 3/8" WEEP TYP. AT BASE <br />BUILDING ENVELOPE <br />�✓F ; , <br />BACKER ROD &SEALANT PER DESIGN DOCS <br />_ <br />- � DRAINAGE MEDIUM PER DESIGN DOCS,- <br />`- ��� � <br />- ;r, PRE -FINISHED METAL THRU-WALL FLASHING W/ HEMMED DRIP <br />I ' , ' ' <br />: : EDGE AND SLOPED HORIZONTAL LEG <br />2818 GRAND AVENUE <br />' <br />-� r <br />---_ J-TRIM PER DESIGN DOCS <br />_ <br />.�� f�= SIDING PER DESIGN DOCS <br />= --� ? " <br />6 SAF OVER FLASHING PER DESIGN DOCS <br />EVERETT WA 98201 <br />2818 GRAND AVENUE <br />TRANSLUCENT SILICONE SEALANT PER DESIGN DOCS <br />:_ __. _ DRAINABLE INSECT PROOF STRIP <br />EVERETT WA 98201 <br />DRAINAGE MEDIUM PER DESIGN DOCS TYP. <br />WRB PER DESIGN DOCS <br />3/8" GAP TYP. <br />: ;; <br />� I � <br />' <br />� � TRIM PER DESIGN DOCS <br />; <br />Sheet Title: <br />I�/ <br />_ <br />SIDING PER ELEVATIONS & DESIGN DOCS <br />., BUG SCREEN <br />3/8" WEEP TYP. AT BASE <br />WALL <br />DETAILS <br />.>.. I PRE -FINISHED METAL FLASHING W/ HEMMED EDGE & SLOPED <br />_ <br />N HORIZONTAL LEG <br />r ---------------------------------------------------------------------------• <br />- - -- <br />__ <br />Z-METAL W/ HEMMED EDGE & 10% <br />Scale: As Noted <br />i <br />f t { #' i` '7' t <br />- — SLOPED HORIZ. LEG, <br />M` <br />PERMIT SET <br />I <br />1/4 MIN GAP FOR VENTING <br />1/4" MIN. GAP FOR VENTING <br />' <br />SIDING PER DESIGN DOCS <br />Drawn By: <br />JMM <br />J - <br />— DRAINAGE MEDIUM PER DESIGN DOCS <br />Checked By: <br />DD/BDF <br />EXRSHEATH NG�I DESIGNPER DOCS REVIEWED „T. � �° � > �, . ; _ <br />F PERM""'I' <br />Issue Date: <br />Sheet Number: <br />03/24/20 <br />7.1 <br />Job #: <br />ID: 433 <br />7 A7.1 <br />TRIM AT INSIDE CORNER -BRICK VENEER TO TYPICAL SIDING <br />8 /A7.1 <br />THRU-WALL FLASHING - PANEL SIDING <br />ID: 62 <br />9 /A7.1 TBELLY <br />BAND - TYPICAL SIDING <br />ID; 61 <br />0580216 <br />SCALE: NTS <br />SCALE: NTS <br />S ALE: NTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.