Laserfiche WebLink
Permit#: B2004-009 <br />Site Address: 2824 GRAND AVE <br />GENERAL CONSTRUCTION NOTES <br />1) THESE DRAWINGS DESCRIBE GENERAL REQUIREMENTS FOR WEATHERIZATION DETAILS. NO PROPOSED CHANGES TO <br />CLADDING TYPES, COLORS, WALL ASSEMBLIES, AND THERMAL RESISTANCE VALUES. REFER TO ORIGINAL STRUCTURAL <br />ENGINEERING DOCUMENTS FOR ANY STRUCTURAL CONCRETE, STEEL OR WOOD FRAMING REQUIREMENTS. <br />2) ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, STANDARDS, AND MANUFACTURER'S INSTRUCTIONS. <br />REPORT ANY DISCREPANCIES TO CONSULTANT. <br />3) CONTRACTOR SHALL VERIFY CONDITIONS ON SITE BEFORE BEGINNING WORK AND REPORT ANY DISCREPANCIES TO <br />CONSULTANT. <br />4) THE CONTRACTOR SHALL BE FAMILIAR W/ THESE DRAWINGS AND DETAILS AND SHALL ENSURE THAT THEIR <br />WORKERS HAVE THE EXPERIENCE, TRAINING AND SKILLS REQUIRED TO EXECUTE THE WORK. <br />5) SUBMIT REQUEST FOR INFORMATION (RFI) TO THE CONSULTANT. SUBMIT ANY CHANGES IN THE CONTRACT VALUE IN THE <br />FORM OF A CHANGE ORDER PROPOSAL TO THE CONSULTANT. <br />6) NOTIFY CONSULTANT OF WORK SCHEDULE AND ACTIVITIES. PROVIDE SPECIAL CONSIDERATION FOR NOISY OPERATIONS, <br />INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. PROTECT LANDSCAPING & FIXTURES. <br />7) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER IMAGES AND ILLUSTRATIONS. <br />8) ALL LUMBER SIZES INDICATED ARE NOMINAL UNLESS DIMENSIONED OR NOTED OTHERWISE. <br />9) EXTERIOR SHEATHING & FRAMING REPAIRS SHALL REQUIRE INSPECTIONS. COORDINATE INSPECTIONS WITH <br />BUILDING OFFICIALS PRIOR TO COVERING. <br />10) DO NOT INSTALL DAMAGED OR DEFECTIVE MATERIAL(S). <br />11) LAP WEATHER RESISTANT BARRIER OVER VERTICAL FLASHING/SAMF A MIN OF 4". UNLESS NOTED OTHERWISE. <br />12) REFER TO MATERIAL DATA SHEETS AND MANUFACTURER'S INSTRUCTIONS BEFORE INSTALLING ANY NEW MATERIALS <br />13) PROVIDE; <br />A) 2" MIN CLEAR @ ALL CLADDING TO HORIZONTAL HARD SURFACES <br />B) 6" MIN CLEAR @ ALL FRAMING TO FINISH GRADE <br />14) EXPOSED FASTENERS SHALL BE SEALED OR GASKETED. INSTALL & LOCATE ALL FASTENERS PER SMACNA. <br />15) HEM METAL FLASHING DRIP EDGES, TYPICAL. PROVIDE FULLY SOLDERED JOINTS IN SECTIONS OF <br />FLASHING JOINED TOGETHER AS INDICATED ON DRAWINGS. <br />16) PROVIDE GALVANIC SEPARATION MATERIAL BETWEEN DISSIMILAR METALS. <br />17) NOTIFY THE CONSULTANT OF ANY PREVIOUSLY UNDISCOVERED DAMAGE, DEFICIENCIES OR THREATS THAT COMPROMISE <br />THE FIRE AND/OR LIFE SAFETY OF THE BUILDING OCCUPANTS. <br />18) CONTRACTOR SHALL PROMPTLY REPORT ANY ACCIDENTAL DAMAGE AND REPAIR AT NO ADDITIONAL COST TO THE OWNER. <br />19) CONTRACTOR SHALL REMOVE DEBRIS AND TRASH FROM THE SITE IMMEDIATELY. DISPOSE OF LEGALLY. KEEP THE <br />BUILDING AND GROUNDS CLEAN AND FREE OF REFUSE AT ALL TIMES. <br />20) CONTRACTOR SHALL DOCUMENT PRE-EXISTING CONDITIONS FOR REFERENCING DURING REPAIR PROCESS. <br />21) CONTRACTOR SHALL NOTIFY THE CONSULTANT OF ANY DISCOVERED MICROBIAL GROWTH DURING THE COURSE OF WORK. <br />22) ALL MATERIALS AND COMPONENTS ARE TO BE NEW UNLESS NOTED OTHERWISE <br />GENERAL WATERPROOFING NOTES <br />1) ALL FLASHINGS SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE WALL OR TO REDIRECT <br />IT TO THE EXTERIOR. <br />2) ALL WALL PENETRATIONS SHALL BE TARGET FLASHED. <br />3) ALL WEATHER RESISTIVE BARRIERS SHALL HAVE POSITIVE LAPPING (SHINGLE STYLE) WHEN INSTALLED. LAPPING AND SEALING OF <br />SEAMS AND JOINTS SHALL BE BY MANUFACTURER'S REQUIREMENTS. <br />4) ALL BUILDING INTERFACES SHALL BE FLASHED TO PREVENT MOISTURE FROM ENTERING THE WALL. <br />5) ALL HORIZONTAL HARD SURFACES SHALL HAVE CODE REQUIRED ADEQUATE SLOPING FOR DRAINAGE. <br />6) AFTER REMOVAL OF DAMAGED MATERIALS, TREAT ADJACENT SURFACES WITH FUNGICIDE AND ANTI -MICROBIAL (BORA-CARE + MOLD <br />CARE) TYPICAL. SURFACES MUST BE DRY BEFORE COVERING. REFER TO SECTION 02 050 DEMOLITION MOISTURE DAMAGE <br />MOCK UP AND TESTING MATRIX <br />AT BEGINNING OF PROJECT CONTRACTOR TO CONTACT J2 BUILDING CONSULTANTS TO ARRANGE REVIEW AND <br />OR TESTING OF FOLLOWING ASSEMBLY SYSTEMS: <br />(LIST MAY NOT INCLUDE ALL AREAS REQUIRING A REVIEW OF MOCK-UP INSTALLATIONS, ADDITIONAL <br />WEATHERIZATION ASSEMBLY SYSTEM MAY REQUIRE ADDITIONAL MOCK UPS AND WATER TESTING AS REQUESTED <br />REQUIRED MOCK UPS: <br />COORDINATION OF INSTALLATION NOTES: <br />WINDOW INSTALLATION <br />YES <br />1. ALL MATERIALS TO BE USED FOR MOCK-UP <br />MUST BE SUBMITTED FOR REVIEW AND <br />APPROVAL BY DESIGN PROFESSIONAL <br />BASE OF WALL FLASHING AND SIDING <br />YES <br />SIDING PENETRATIONS <br />YES <br />BEFORE USE. <br />2. MOCK-UP REVIEW SHALL CONSIST OF A <br />STEP BY STEP INSTALLATION SEQUENCING <br />DONE ON SITE. <br />3. IN PLACE MOCK-UPS MUST BE PERFORMED <br />DECK COATING & FLASHINGS <br />YES <br />DOOR INSTALLATION <br />YES <br />WALL MEMBRANES, RAINSCREEN <br />YES <br />SIDING AND TRIM <br />YES <br />BY PERSONNEL WHO WILL BE DOING THE <br />ACTUAL INSTALLATION. <br />JOINT BACKER ROD &SEALANT <br />YES <br />PULL TESTS <br />4. WATER TESTING AT WINDOWS AND DOORS <br />SHALL BE PERFORMED PRIOR TO FULL <br />PAINT SCHEME DISPLAYING ALL <br />SELECTED COLORS <br />YES <br />SIDING INSTALLATION. TEMPORARY SIDING <br />IMITATING INSTALLED CONDITION SHALL BE <br />UTILIZED TO IMITATE FINAL INSTALLATION. <br />5. ALL WINDOW TYPES TO BE TESTED. TWO <br />TESTS TOTAL PER TYPE, ONE AT BEGINNING <br />EXTERIOR LIGHTING <br />YES <br />ROOF TO WALL <br />YES <br />WINDOW SPRAY TESTING <br />YES-2 <br />MOCKUPS <br />AND ONE AT MID PROJECT. <br />6. CONTACT J2 48 HOURS PRIOR TO SCHEDULE <br />MOCK UPS AND TESTING. MOCK UP AND <br />TESTING SHALL BE INCLUDED IN <br />DAMAGE REPAIR <br />YES <br />PAINTING & PREP <br />YES <br />COLUMN TRIM AND FLASHINGS <br />YES <br />CONTRACTORS OVERALL CONSTRUCTION <br />SCHEDULE. <br />7. LIST MAY NOT INCLUDE ALL ITEMS <br />REQUIRING MOCK UP REVIEW. ADDITIONAL <br />MOCK UPS AND/OR WATER TESTING MAY BE <br />REQUESTED AS REQUIRED BY BUILDING <br />ENVELOPE CONSULTANT OF RECORD. <br />NOTES: <br />1. PROVIDE EXTERIOR PRODUCT SUBMITTALS FOR REVIEW AND APPROVAL BY J2 PRIOR TO INSTALLATION. <br />2. WATER TESTING MAY BE REQUIRED BY CONSULTANT. <br />fN .� '-' rvvrt 1 ri <br />1 VICINITY MAP <br />A0.1 N.T.S. 1�y <br />GENERAL NOTES <br />SITE ADDRESS: <br />YEAR BUILT: <br />NO. OF BUILDINGS: <br />NO. OF UNITS: <br />OCCUPANCY: <br />CONSTRUCTION TYPE: <br />2 RA AVENUE <br />EVERE �9201 <br />2824 GRAND AVENUE <br />EVERETT WA 98201 <br />1999-2001 <br />t <br />123 <br />R-2, B & S-2 <br />IB BASEMENT AND 1ST STORY (SPRINKLERED) <br />VB 2ND - 6TH STORIES (SPRINKLERED) <br />01049300110100 - 01049300161200 <br />t <br />PROJECT DESCRIPTION <br />AT LOCATIONS SPECIFIED ON ELEVATIONS: <br />1. REMOVE -AND REPLACE SIDING, WRB & TRIM y <br />2. REMOVE AND REPLACE WINDOWS, SLIDING GL/ <br />. DO(RS( SWING D��PERPECIFICQTIO <br />3. INSTALL NEW DECK SHEATHING, WATERPROOF <br />COATING, AND DECK SOFFITS. EXISTING DECK <br />GUARDRAILS TO BE DETACHED AND RESET. <br />4. PAINT ALL SIDING PER PLANS. <br />PROJECT TEAM <br />OWNER <br />NAUTICA SOUNDVIEW HOA <br />C/O TOM GISH, GARDNER PROPERTY MANAGEMENT <br />2907 HEWITT AVE. <br />EVERETT, WA 98201 <br />ARCHITECT ENGINEER CONSULTANT: <br />J2 BUILDING CONSULTANTS, INC. <br />8425 44TH AVE. W <br />MUKILTEO, WA 98275 <br />CONTRACTOR <br />TBD <br />VICINITY MAP <br />N.T.S. <br />INDEX TO DRAWINGS <br />A0.1 PROJECT SUMMARY, GENERAL NOTES, & SITE PLAN <br />A0.2 SCOPE OF WORK <br />A0.3 WALL, DECK, & ROOF TYPES <br />A0.4 SITE PHOTOS <br />A1.1 FLOOR PLANS <br />ELEVATIONS ,Q A Zd 7 <br />A3.1 WINDOW SEQUENCING <br />A4.1 WINDOW DOOR DETAILS <br />A4.2 WINDOW DOOR DETAILS <br />A5.1 DECK DETAILS <br />A5.2 DECK DETAILS <br />A6.1 PENETRATION DETAILS <br />A7.1 WALL DETAILS <br />A7.2 WALL DETAILS <br />A7.3 WALL DETAILS <br />A7.4 WALL DETAILS <br />A8.1 ROOF DETAILS <br />A8.2 ROOF DETAILS <br />PROJECT LOCATION <br />2818 GRAND <br />2824 GRAND AVE <br />BUILDING CODES <br />NOT ALL CODES MAYBE APPLICABLE TO THE SCOPE OF WORK <br />2015 INTERNATIONAL EXISTING BUILDING CODE <br />2015 INTERNATIONAL BUILDING CODE <br />2015 INTERNATIONAL RESIDENTIAL CODE <br />2015 INTERNATIONAL MECHANICAL CODE <br />2015 INTERNATIONAL ENERGY CODE <br />2015 INTERNATIONAL FIRE CODE <br />2015 INTERNATIONAL PROPERTY MAINTENANCE CODE <br />2015 UNIFORM PLUMBING CODE <br />2015 NATIONAL ELECTRIC CODE <br />2015 WASHINGTON STATE ENERGY CODE <br />2015 INTERNATIONAL ENERGY CONSERVATION CODE <br />ALL BUILDING CODES TO ADHERE TO WASHINGTON STATE AMENDMENTS <br />. U <br />PLANNING & COMMUNITY <br />DEVELOPMENT DEPT. <br />SYMBOLS INDICATED MAY OR MAY NOT BE IN USE WITHIN THIS GIVEN PROJECT <br />QREVISION <br />DELTA <br />F01 <br />WINDOW TAG <br />01 <br />KEY NOTE <br />D000 <br />DOOR TAG <br />WWALL <br />TYPE <br />80.0--------- <br />GRID SYMBOL <br />101 <br />ROOM NUMBER <br />N <br />(D NORTH ARROW <br />DRAWING NUMBER <br />TITLE <br />SCALE: NTS <br />SCALE (NTS = NOT TO SCALE) <br />ELEVATION TAG <br />A <br />Asoo <br />DETAIL TAG <br />A <br />Asoo � <br />A SECTION TAG <br />Asoo - - <br />SHEET NUMBER <br />Owner: H T LLC <br />Tenant: NAUTICA SOUNDVIEW CONDOS <br />App. Date: 4/7/2020 <br />Proposed Use: COMMERCIAL <br />Description: REPLACE SIDING, TRIM, WINDOWS, <br />SLIDING GLASS DOORS AND <br />Reviewed By n Date: <br />Office Set lob Site Set Fref Planning Set <br />7 <br />8425 44th Ave. W. <br />Mukilteo, WA 98275 <br />Tel 425.774.5600 <br />Fax 425.774.5661 <br />www.J2Consultants.com <br />The undersigned has provided building enclosure <br />documents that in my professional judgement are <br />appropriate to satisfy the requirements of RCW <br />64.55.005 through 64.55.090 <br />12495 5REGISTERED <br />ARCHITECT <br />r � <br />BRIAN FAJARDO <br />STATE OF WASHINGTON <br />NOTES: <br />NORTH 1. CONTRACTOR IS RESPONSIBLE <br />FOR FIELD VERIFICATION OF <br />SIZING AND QUANTITIES OF ALL <br />COMPONENTS. <br />2. MOCK UP REVIEW OF ALL <br />EXTERIOR ASSEMBLIES <br />REQUIRED BEFORE INSTALLATION. <br />3. DRAWINGS ARE DIAGRAMMATIC <br />ONLY AND ARE NOT TO BE USED <br />FOR TAKE OFF QUANTITIES. <br />CITE OF EVERETT <br />Revisions: <br />Date <br />Project Title: <br />NAUTICA CONDOMINIUMS <br />BUILDING ENVELOPE <br />2848 GRAND AVENUE <br />EVERETT WA 98201 <br />Sheet Title: <br />PROJECT SUMMARY <br />& GENERAL NOTES <br />Scale: As Noted <br />PERMIT SET <br />Drawn By: JMM <br />Checked By: DD/BDF <br />Issue Date: Sheet Number. <br />03/24/20 <br />Job #: AO.1 <br />0580216 <br />