m41
<br />ili-1-11
<br />REPLACEMENT
<br />BUILDING ELEMENT 1-10,
<br />SOFFITS
<br />REMOVE EXISTING SOFFIT MATERIAL. INSTALL
<br />FIBER CEMENT SOFFIT
<br />02 40 00 DEMOLITION AND
<br />6/A5.1, 7/A5. 1,
<br />DENSDECK AND FIBER CEMENT WITH CONTINUOUS
<br />MOISTURE DAMAGE;
<br />1/A5.2, 3/A7.2,
<br />VENT STRIP AT EACH END OF JOIST BAYS.
<br />_6
<br />07 46 46 FIBER CEMENT SIDING;
<br />5/A7.2, 7/A7.3
<br />RI
<br />,,, ctc 'T I 1 67' 6—AA', t, i A I- - 0,:` 4/1' F'� 7 /7-
<br />07 27 00 WEATHER RESISTIVE AIR
<br />-
<br />/4
<br />711,=
<br />BARRIERS;
<br />rA
<br />07 62 00 SHEET METAL FLASHING;
<br />07 92 00 JOINT SEALANTS
<br />R2
<br />AWNINGS
<br />EXISTING METAL AWNINGS AT STREET LEVEL TO
<br />NA
<br />NA
<br />NA
<br />REMAIN.
<br />COPING
<br />EXISTING COPING TO REMAIN. INSTALL NEW SIDING
<br />NA
<br />NA
<br />6/A7.3, 9/A7.3
<br />UP TO EXISTING PARAPET FASCIA TRIM/FLASHING.
<br />R3
<br />NEW STANDING SEAM METAL COPING TO BE
<br />INSTALLED AT BUILDING PROJECTION ON EAST
<br />ELEVATION
<br />ROOF DECK
<br />REMOVE EXISTING ROOFING AND COPING. INSTALL
<br />SOPREMA ALSAN RS
<br />07 62 00 SHEETMETAL FLASHING
<br />9/A7.3
<br />R4
<br />NEW PMMA DECK COATING AND INSTALL NEW
<br />ROOF
<br />STANDING SEAM METAL COPING.
<br />4:12 SLOPED
<br />AT 4:12 SLOPED ROOF ON N ELEVATION OF BLDG 2818,
<br />CERTAINTEED LANDMARK
<br />07 320 COMPOSITION SHINGLES
<br />I/A8.1, 2/A8. 1,
<br />ROOFING
<br />REMOVE EXISTING SINGLE PLY ROOFING. INSTALL
<br />PREMIUM; CERTAINTEED
<br />07 62 00 SHEETMETAL FLASHING
<br />3/A8.1, 4/A8. 1,
<br />UNDERLAYMENT, AND COMPOSITE SHINGLES. INSTALL
<br />ROOFERS' SELECT;
<br />5/A8.1, 6/A8.1
<br />R5
<br />NEW METAL FLASHING AT ROOF TO WALL
<br />CERTAINTEED
<br />INTERSECTIONS. INSTALL NEW ICE & WATER SHIELD AT
<br />WINTERGUARD;
<br />ALL EAVES. INSTALL TURTLE VENTS AT LOCATIONS
<br />ADDITIONAL
<br />INDICATED ON PLANS.
<br />CERTAINTEED ROOFING
<br />MATERIALS PER SPECS
<br />LOW SLOPED
<br />AT LOW SLOPED ROOF ON N ELEVATION OF BLDG 2818,
<br />CERTAINTEED LANDMARK
<br />07 320 COMPOSITION SHINGLES
<br />7/A8.1, 8/A8. 1,
<br />ROOFING
<br />REMOVE EXISTING SINGLE PLY ROOFING. INSTALL NEW
<br />PREMIUM; CERTAINTEED
<br />07 62 00 SHEETMETAL FLASHING
<br />9/A8.1, I/A8.2,
<br />PMMA DECK COATING. INSTALL NEW METAL FLASHING
<br />ROOFERS' SELECT;
<br />2/A8.2, 3/A8.2
<br />R6
<br />AT ROOF TO WALL INTERSECTIONS.
<br />CERTAINTEED
<br />WINTERGUARD;
<br />ADDITIONAL
<br />CERTAINTEED ROOFING
<br />MATERIALS PER SPECS
<br />SWING DOORS
<br />ALL PRIVATE DECK SWING DOORS TO BE REMOVED
<br />THERMATRU
<br />08 53 13 VINYL WINDOWS AND
<br />I/A4.1, 2/A4. 1,
<br />AND REPLACED EXCEPT AS NOTED IN DESIGN DOCS.
<br />DOORS
<br />3/A4.1, 4/A4. 1,
<br />METAL HALL ENTRY DOORS AT ELEVATED COURTYARD
<br />06 20 00 FINISH CARPENTRY;
<br />2/A4.2, 3/A4.2,
<br />F1
<br />TO REMAIN. PAINT PER SPECIFICATIONS. STOREFRONT
<br />07 62 00 SHEETMETAL FLASHING
<br />4/A4.2, 5/A4.2,
<br />DOORS ARE NIC.
<br />I/A4.3, 2/A4.3,
<br />3/A4.3
<br />F2
<br />GARAGE DOORS
<br />EXISTING GARAGE DOOR TO REMAIN
<br />NA
<br />NA
<br />NA
<br />WINDOWS & SLIDING
<br />REMOVE AND REPLACE SLIDING GLASS DOORS AS
<br />MILGARD MONTECITO
<br />08 53 13 VINYL WINDOWS AND
<br />SHEET A3.1, 5/A4.1,
<br />GLASS DOORS
<br />NOTED PER ELEVATIONS. MODIFY INTERIOR
<br />DOORS;
<br />6/A4.1, 7/A4. 1,
<br />FENESTRATIONS
<br />TRIM/SURROUNDS AS NEEDED TO ACCOMMODATE
<br />06 20 00 FINISH CARPENTRY;
<br />8/A4.1, 9/A4. 1,
<br />(WINDOWS AND
<br />REQUIRED DETAILING. ENSURE EGRESS OPENINGS ARE
<br />07 62 00 SHEETMETAL FLASHING
<br />I/A4.2, 6/A4.2,
<br />DOORS)
<br />ADEQUATE, ENSURE SAFETY GLAZING AT HAZARDOUS
<br />7/A4.2, 8/A4.2,
<br />LOCATIONS, AND ENSURE GUARDS/LIMITERS ARE
<br />9/A4.2, I/A4.3,
<br />INSTALLED WHERE APPLICABLE. CONTRACTOR TO
<br />2/A4.3, 3/A4.3
<br />F3
<br />INCLUDE CONTRACTOR SERVICES TO ACCOMMODATE
<br />WINDOW TESTING, IN PLACE, FOR EACH TYPE OF
<br />WINDOW. (3) WINDOWS (MIN.) TO BE TESTED AT
<br />EACH BUILDING. AT EXISTING WINDOWS, INSTALL
<br />NEW SAF AT WINDOW JAMB AND HEAD OVER NAIL
<br />FLANGE. WINDOWS AT ELEVATOR CORRIDOR OF BLDG
<br />2824 (BUILDING A) TO HAVE LIMITERS INSTALLED.
<br />REFER TO ELEVATIONS
<br />GENERAL SIDING
<br />REMOVE AND REPLACE SIDING, WRB AND FLASHINGS
<br />FIBER CEMENT SIDING,
<br />02 40 00 DEMOLITION AND
<br />ELEVATIONS, I/A7.1,
<br />AS CITED. PROVIDE ALLOWANCE TO REPLACE/REPAIR
<br />EXPOSURE TO MATCH TO
<br />MOISTURE DAMAGE;
<br />2/A7.1, 8/A7.3,
<br />EXTERIOR SHEATHING AND FRAMING. NEW SIDING TO
<br />EX.
<br />07 46 46 FIBER CEMENT SIDING;
<br />2/A7.4
<br />1
<br />RE INSTALLED ON A AINSCREEN SYSTEM. EXISTING
<br />7 27 0 EATHER RESISTIVE AIR
<br />SIDING AT STOREFRONTS TO REMAIN. PAINT PER
<br />BARRIERS;
<br />SPECIFICATIONS.
<br />07 62 00 SHEET METAL FLASHING;
<br />07 92 00 JOINT SEALANTS;
<br />09 29 00 GYPSUM BOARD
<br />GENERAL SIDING
<br />REMOVE AND REPLACE SIDING, WRB AND FLASHINGS
<br />FIBER CEMENT PANEL
<br />02 40 00 DEMOLITION AND
<br />ELEVATIONS, 1/A7.1,
<br />AS NOTED. PROVIDE ALLOWANCE TO REPLACE/REPAIR
<br />SIDING
<br />MOISTURE DAMAGE;
<br />2/A7.1, 8/A7.1
<br />EXTERIOR SHEATHING AND FRAMING. NEW SIDING TO
<br />07 46 46 FIBER CEMENT SIDING;
<br />8/A7.3, 2A/7.4
<br />W2
<br />BE INSTALLED ON A RAINSCREEN SYSTEM. EXISTING
<br />07 29 00 WEATHER RESISTIVE AIR
<br />SIDING AT STOREFRONTS TO REMAIN. PAINT PER
<br />BARRIERS;
<br />SPECIFICATIONS.
<br />07 62 00 SHEET METAL FLASHING;
<br />07 92 00 JOINT SEALANTS;
<br />09 290 GYPSUM BOARD
<br />INSIDE CORNER TRIM
<br />REPLACE INSIDE CORNER TRIM
<br />TAMLYN "W" METAL FOR
<br />07 46 46 FIBER CEMENT SIDING
<br />5/A7.1, 6/A7. 1,
<br />W3
<br />INTERIOR CORNERS
<br />8/A7.1
<br />OUTSIDE CORNER
<br />REMOVE AND REPLACE OUTSIDE CORNER TRIM
<br />FIBER CEMENT 5/4 X 3
<br />07 46 46 FIBER CEMENT -SIDING
<br />3/A7.1, 4/A7.1
<br />W4
<br />TRIM
<br />1/211
<br />BASE OF WALL
<br />ADD BASE OF WALL FLASHING AT ALL LOCATIONS. SEE
<br />PER SPECS AND DETAILS
<br />07 62 00 SHEETMETAL FLASHING
<br />I/A5,2, 2/A7.2,
<br />DETAILS FOR VARIOUS CONFIGURATIONS. INTEGRATE
<br />3/A7.2, 7/A7.2,
<br />W/ DECK SYSTEMS WHERE APPLICABLE. ALTERNATE:
<br />7A/7.3
<br />WS
<br />OPTION I - INSTALL VOF POLYEUTRETHANE STRIP TO
<br />ALL NEW BASE OF WALL FLASHINGS. OPTION 2 -
<br />INSTALL IOF 10-YR WARRANTIED POLYEUTRETHANE
<br />STRIP TO ALL NEW BASE OF WALL FLASHINGS. 10YR
<br />WARRANTY TO INCLUDE ALL NEW DECK COATING
<br />TOP OF WALL
<br />PROVIDE GAP AT TOP OF WALL TO VENTILATE RAIN
<br />5/4"X 3-1/2" FIBER
<br />07 46 46 FIBER CEMENT SIDING;
<br />5/A7.2, 3/A7.3,
<br />WALLS
<br />W6
<br />SCREEN. PROVIDE CONTINUOUS BUG SCREEN
<br />CEMENT TRIM OR EQ.
<br />07 62 00 SHEET METAL FLASHING
<br />6/A7.3, 9/A7.3
<br />(CORAVENT) AND COVER WITH FLASHING.
<br />WITH COUNTER
<br />FLASHING
<br />PENETRATIONS IN
<br />CONTRACTOR TO DETACH AND RESET ALL ELECTRICAL
<br />PER SPECS AND DETAILS
<br />07 62 00 SHEETMETAL FLASHING;
<br />SHEET A6.1, 1/A7.4
<br />SIDING
<br />OUTLETS, SWITCHES, BOXES, SATTELITE DISHES,
<br />08 90 00 LOUVERS AND VENTS
<br />PHONE/CABLE WIRING AND OTHER DEVICES
<br />W7
<br />NECESSARY TO COMPLETE THE SIDING WORK.
<br />SERVICES NO LONGER IN USE SHALL BE PERMANENTLY
<br />REMOVED RATHER THAN RESET. REPLACE ALL HVAC
<br />HOODS WITH FLANGED VENTS AND TIGHT -LINE TO
<br />DUCTS.
<br />FASCIA TRIM
<br />REMOVE EXISTING FASCIA TRIM AND BELLY BAND
<br />5/4" FIBER CEMENT TRIM
<br />02 40 00 DEMOLITION AND
<br />6/A5.1, 7/A5. 1,
<br />TRIM. INSTALL NEW FASCIA TRIM/BELLY BAND TRIM
<br />MOISTURE DAMAGE;
<br />6/A7.2, 7/A7.3,
<br />AT BUILDING FACE AND DECK FASCIA, INTEGRATE
<br />07 46 46 FIBER CEMENT SIDING;
<br />9/A7A
<br />W8
<br />WITH NEW WRB AND SAF.
<br />07 27 00 WEATHER RESISTIVE AIR
<br />BARRIERS;
<br />WRAP DECK COLUMNS IN FIBER CEMENT TRIM
<br />07 62 00 SHEET METAL FLASHING;
<br />07 92 00 JOINT SEALANTS
<br />CONCRETE WALLS
<br />NOT IN SCOPE OF WORK. PAINT CONCRETE IF
<br />SEE SPECS
<br />07 62 00 SHEET METAL FLASHING;
<br />7/A7.2, 8/A7.2,
<br />PREVIOUSLY PAINTED. AT CONCRETE -TO -BRICK AND
<br />GM OPTIC TRANSLUCENT
<br />09 90 00 EXTERIOR PAINTING
<br />I/A7.3, 2/A7.3,
<br />CONCRETE -TO -FRAMED WALL INTERSECTIONS, INSTALL
<br />SILICONE SEALANT
<br />09 96 50 TRANSLUCENT SILICONE
<br />4/A7.3, 5/A7.3
<br />W9
<br />SILICONE SEALANT PER DESIGN DOCUMENTS, IF WALL
<br />COATING
<br />HAD METAL COPING INSTALLED, INSTALL NEW
<br />STANDING SEAM WALL COPING, IF WALL WAS
<br />EXPOSED CONCRETE, INSTALL TRANSLUCENT SILICONE
<br />SEALANT PER DESIGN ROCS
<br />BRICK
<br />NOT IN SCOPE OF WORK. AT BRICK -TO -CONCRETE
<br />GM OPTIC
<br />07 62 00 SHEET METAL FLASHING;
<br />7/A7.2, 8/A7.2, I/A7.3
<br />W10
<br />INTERSECTIONS, INSTALL SILICONE SEALANT PER
<br />TRANSLUSCENT SILICONE
<br />09 96 50 TRANSLUCENT SILICONE
<br />DESIGN DOCUMENTS. INSTALL NEW STANDING SEAM
<br />SEALANT
<br />COATING
<br />PARAPET WALL COPING.
<br />DECKS
<br />REMOVE AND DISPOSE OF ALL EXISTING DECK
<br />ASSUME "LIKE FOR LIKE"
<br />02 40 00 DEMOLITION AND
<br />SHEET A5.1, I/A5.2
<br />COATINGS AS NOTED, FLASHINGS AND SHEATHING
<br />FRAMING
<br />MOISTURE DAMAGE;
<br />D1
<br />(TAKE DECK SURFACE DOWN TO FRAMING). PROVIDE
<br />CONFIGURATION. USE
<br />06 10 00 ROUGH CARPENTRY
<br />FRAMING REPAIR ALLOWANCE. INSTALL NEW
<br />ALL P.T. LUMBER
<br />07 18 00 PEDESTRIAN TRAFFIC
<br />SHEATHING AND DECK COATING. ALTERNATE: OPTION
<br />COATING
<br />DECKS/ENTRIES/
<br />2 - NEW DECK COATING TO INCLUDE 10YR WARRANTY
<br />PER SPECS
<br />GUARDRAILS
<br />REMOVE AND REINSTALL EXISTING GUARDRAILS ON
<br />02 40 00 DEMOLITION AND
<br />6/A5.1, 7/A5. 1,
<br />COURTYARDS
<br />RAISED MOUNTING BLOCKS INTEGRATED WITH DECK
<br />MOISTURE DAMAGE
<br />4/A7.2
<br />D2
<br />COATING. INSTALL NEW "L" METAL BRACKET AT BASE
<br />07 18 00 PEDESTRIAN TRAFFIC
<br />OF GUARDRAILS TO RESTRICT OPENING TO 4" OR LESS.
<br />COATING
<br />GUARDRAILS AT STREET LEVEL NOT INCLUDED IN
<br />SCOPE.
<br />STRUCTURAL
<br />S1
<br />NA
<br />NOT INCLUDED IN SCOPE OF WORK
<br />NA
<br />NA
<br />NA
<br />CRAWLSPACE
<br />NA
<br />NOT INCLUDED IN SCOPE OF WORK
<br />NA
<br />NA
<br />NA
<br />AND BELOW
<br />NA
<br />GRADE
<br />LIGHTING
<br />Ll
<br />WALL SCONCES
<br />REMOVE AND REPLACE WALL SCONCES AT PRIVATE
<br />SEE SPECS
<br />NA
<br />3/A6.1, 5/A6. IL
<br />DECKS AND COURTYARDS
<br />PAINT
<br />NEW TRIM TO BE PRE -PRIMED. PRIME AND PAINT ALL
<br />SEE SPECS
<br />09 90 00 EXTERIOR PAINTING
<br />NA
<br />CUT ENDS OF NEW TRIM. APPLY 2 COATS OF PREMIUM
<br />EXTERIOR ACRYLIC LATEX PAINT TO ALL NEW FIBER
<br />MISCELLANEOUS
<br />NA
<br />CEMENT SIDING AND TRIM AND ALL OTHER EXISTING
<br />PAINTED SURFACES. ASSUME ONE COLOR FOR BODY
<br />AND ONE COLOR FOR TRIM. ALL SURFACES TO BE
<br />PAINTED
<br />q
<br />E OR PERM
<br />Jk vf'ED FC)
<br />8425 44th Ave. W
<br />Mukilteo, WA 98275
<br />Tel 425.774.5600
<br />Fax 425.774.5661
<br />www.J2Gonsultants.com
<br />The undersigned has provided building enclosure
<br />documents that in my professional judgement are
<br />appropriate to satisfy the requirements of RCW
<br />64.55.005 through 64.55.090
<br />NOTES:
<br />CONTRACTOR IS RESPONSIBLE
<br />FOR FIELD VERIFICATION OF
<br />SIZING AND QUANTITIES OF ALL
<br />COMPONENTS.
<br />MOCK UP REVIEW OF ALL
<br />EXTERIOR ASSEMBLIES
<br />REQUIRED BEFORE INSTALLATION.
<br />3 DRAWINGS ARE DIAGRAMMATIC
<br />ONLY AND ARE NOT TO BE USED
<br />FOR TAKE OFF QUANTITIES.
<br />R70M
<br />M_
<br />�11 =-go
<br />
|