My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2824 GRAND AVE 2020 NAUTICA CONDOMINIUMS Plans 2022-11-08
>
Address Records
>
GRAND AVE
>
2824
>
NAUTICA CONDOMINIUMS
>
Plans
>
2824 GRAND AVE 2020 NAUTICA CONDOMINIUMS Plans 2022-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 10:32:20 AM
Creation date
6/16/2022 9:33:15 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2824
Tenant Name
NAUTICA CONDOMINIUMS
Permit
B2004-009
Year
2020
Notes
REPLACE SIDING, TRIM, WINDOWS, SLIDING GLASS DOORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
%", <br />26 GA. PRE -FINISHED METAL <br />UNLESS NOTED OTHERWISE /+ 6" SAF OVER TOP OF <br />/ / 1 METAL, TYP. <br />SEALANT PER DESIGN DOCS <br />{ TAPE OR SEAL WRB TO FLASHING <br />V-0" MIN. <br />OVERLAP <br />e4111y. / . %` (WRB NOT SHOWN FOR CLARITY) <br />r <br />WRB/ AIR BARRIER <br />/ ` s <br />}} <br />PROVIDE PRE-FAB. <br />TRIM PER DESIGN DOCS <br />Copyright © 2018 All rights reserved. <br />J2 Building Consultants, Inc. <br />CORNER ASSEMBLIES TYP. <br />WRAP ROLL AT ONE SIDE AROUND CORNER MIN.12" <br />,,r' / ' ,,�- <br />_____ ------------- - --------=-=-------_____--------------- -__----------:�ti <br />Lu LAP COURSE ON ADJACENT WALL OVER FIRST <br />COURSE AND AROUND CORNER MIN.12 <br />/- ,� �.� �,. <br />, • - .- <br />DRAINAGE MEDIUM PER DESIGN DOCS TYP.8425 <br />t i t r t ! ; ( ;; <br />44th Ave. W. <br />Mukilteo WA 98275 <br />Te1425.774.5600 <br />Fax 425.774.5661 <br />o `. CREATING A WEAVE <br />le, <br />1 <br />www.J2Consultants.com <br />Li <br />w START W/ 1/2 ROLL <br />S <br />- " ,/ — 10% MIN. SLOPE TO DRAIN <br />' <br />SEALANT PER DESIGN DOCS <br />AIR BARRIER TAPE PER MFR <br />The undersigned has provided building enclosure <br />TAPE VERTICAL SEAMS <br />- <br />HEMMED DRIP EDGE, TYP.� <br />�� <br />. ;; --- WRB PER DESIGN DOCS; <br />OVERLAP WRB MIN.12" PAST CORNERS TYP. <br />documents that in my professional judgement are <br />appropriate to satisfy the requirements of RCW <br />64.55.005 through 64.55.090 <br />DOUBLE BEAD OF BEDDING SEALANT <br />�--- LAP JOINTS A MINIMUM OF 4" <br />: - -;• F '; EX. INSULATION & FRAMING <br />� ;: <br />NOTE: REFER TO MANUFACTURER'S <br />INSTRUCTIONS FOR WRB/ AIR BARRIER INSTALL <br />/ APPLY 2 BEADS OF SEALANT <br />3/8" MIN. FOLDED END DAM <br />;� EX. SHEATHING <br />-- .� <br />fi <br />�� <br />' �� ` �' SIDING PER ELEVATIONS & DESIGN DOGS TYP. <br />12 4 9 5 <br />REGISTERED <br />ARCHITECT <br />SAF OR PRE -STRIP OF WRB <br />WHERE SPECIFIEDRIAN <br />s <br />� <br />FAJARDO <br />e <br />E OF WASHINGTON <br />PROVIDE PRE -FABRICATED <br />CORNER ASSEMBLIES TYP. <br />1 /A7.1 <br />TYPICAL WRB APPLICATION <br />2 /A7.1 <br />TYPICAL FLASHING LAP <br />ID:: <br />3 /A7.1 <br />TRIM AT OUTSIDE CORNER -TYPICAL SIDING <br />ID:: <br />NOTES: <br />1. CONTRACTOR IS RESPONSIBLE <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />FOR FIELD VERIFICATION OF <br />SIZING AND QUANTITIES OF ALL <br />COMPONENTS. <br />KEEP EX. WRB <br />"'—" <br />�� — <br />2. MOCK UP REVIEW OF ALL <br />WRAPPING PAST CORNER 18" MIN <br />i <br />EX. SIDING <br />EXTERIOR ASSEMBLIES <br />SEALANT PER DESIGN DOCS <br />''- a EX. INSULATION & FRAMING TYR <br />REQUIRED BEFORE INSTALLATION. <br />SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM PER <br />DESIGN DOCS NEW TRIM PER DESIGN DOCS <br />j SIDING PER ELEVATIONS & DESIGN DOCS TYP. <br />3 <br />_ + EX. SHEATHING TYP. <br />EX. WRB <br />3. DRAWINGS ARE DIAGRAMMATIC <br />ONLY AND ARE NOT TO BE USED <br />EX. INSULATION & FRAMING TYP. <br />::. <br />�- <br />FOR TAKE OFF QUANTITIES. <br />WRB PER DESIGN DOCS <br />" EX. SHEATHING TYP. <br />fi} 4 jfiA 3 <br />.i� <br />f n i <br />SEALANT PER DESIGN DOCS <br />----- -- --- <br />:' <br />U <br />$ fi EX. INSIDE CORNER TRIM, REPLACE SEALANT IF <br />�_ p <br />+ R <br />-------------- --- -- -._. ----- --- --- - <br />_ ; , _ <br />.. <br />�j INSIDE CORNER TRIM PER DESIGN DOCS <br />DAMAGED OR FAILING <br />g! +a <br />r' NEW TRIM PER DESIGN DOCS <br />�\ " =k'A 1 <br />°` �j SEALANT PER DESIGN DOCS.: <br />a. 1 <br />' SEALANT PER DESIGN DOCS <br />l f ' ` <br />t 1 <br />a. <br />- " DRAINAGE MEDIUM PER DESIGN DOCS TYP. <br />W :: <br />'o ;; WRB PER DESIGN DOCS; OVERLAP WRB 12" MIN. PAST CORNERS TYP.: <br />s °:� <br />;,.- <br />- DRAINAGE MEDIUM PER DESIGN DOCS TYP. <br />j I <br />; WRB PER DESIGN DOCS, 12"MIN OVERLAP WITH EX. WRB <br />T NEW SEALANT PER DESIGN DOCS <br />..-,....,. <br />= Z <br />N^.— <br />E <br />SIDING PER ELEVATIONS & DESIGN DOCS <br />a. ■ <br />Revisions: <br />- EX. WRB <br />_ <br />_ EX. INSULATION & FRAMING <br />! <br />EX. SHEATHING <br />s <br />11 <br />�r----------------------------------------- _ <br />3 s f ` f r 4 r <br />i / <br />A <br />t5 (j t}} <br />1. <br />I <br />., 1 <br />r `--------.__..------------ ----------------------------------------------------------------------------------- <br />. _ , _ y. <br />f i: <br />j <br /># Date Description <br />EX. SIDING <br />1 <br />i <br />j <br />KEEP EX. WRB <br />V `- <br />WRAPPING PAST CORNER 18" MIN <br />4 /A7.1 <br />TRIM AT OUTSIDE CORNER -NEW SIDING TO EXISTING SIDING <br />1D <br />5 /A7.1 <br />TRIM AT INSIDE CORNER - TYPICAL SIDING <br />6 /A7.1 <br />TRIM AT INSIDE CORNER -NEW SIDING TO EXISTING SIDING <br />ID <br />SCALE: NTS <br />SCALE: NT <br />ALE: N <br />SCALE: NTS <br />�---- SIDING PER DESIGN DOCS <br />-- — DRAINAGE MEDIUM PER DESIGN DOCS <br />" f-� ---- EX. INSULATION & FRAMING TYP. <br />�.�-- WRB FIELD LAYER LAPS METAL FLASHING, APPLY SEALANT/TAPE AT <br />-- WRB TERMINATIONS <br />!_ <br />- <br />-- <br />w <br />' ` _--- — EX. SHEATHING TYP. <br />: <br />Project Title: <br />6" SAF OVER TOP OF METAL, TYP. <br />i _ _ _------ EX. BRICK VENEER <br />w <br />EX. SHEATHING <br />,t �. <br />' DRAINABLE INSECT PROOF STRIP <br />j 3/8" WEEP TYP. AT BASE <br />NAUTICA CONDOMINIUMS <br />BUILDING ENVELOPE <br />--_ <br />fi� <br />BACKER ROD & SEALANT PER DESIGN DOCS <br />WRB PER DESIGN DOCS, APPLY SEALANTITAPE AT WRB TERMINATIONS <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />' <br />�'' <br />I <br />�, PRE -FINISHED METAL THRU-WALL FLASHING W/ HEMMED DRIP <br />EDGE AND SLOPED HORIZONTAL LEG <br />2818 GRAND AVENUE <br />✓ I <br />_` - SIDING PER DESIGN DOCS <br />I <br />EVERETT WA 98201 <br />J-TRIM PER DESIGN DOCS <br />_ <br />6" SAF OVER FLASHING PER DESIGN DOCS--; <br />' <br />2818 GRAND AVENUE <br />TRANSLUCENT SILICONE SEALANT PER DESIGN DOCS <br />/ <br />;,n"--� :. � ; DRAINABLE INSECT PROOF STRIP <br />EVERETT WA 98201 <br />......... <br />,! �` °` <br />DRAINAGE MEDIUM PER DESIGN DOCS TYP. <br />1 <br />- -__ I '; 3/8" GAP TYP. <br />"t j <br />TRIM PER DESIGN DOCS <br />Sheet Title: <br />WRB PER DESIGN DOCS <br />s <br />I : <br />; <br />SIDING PER ELEVATIONS & DESIGN DOCS <br />" ; ` <br />N <br />BUG SCREEN <br />3/8" WEEP TYP. AT BASE <br />WALL <br />DETAILS <br />' - <br />PP <br />✓' f :J----------------------------------------------------- <br />._ <br />I <br />PRE -FINISHED METAL FLASHING W/ HEMMED EDGE & SLOPED <br />HORIZONTAL LEG <br />1 <br />f i <br />f Z-METAL W/ HEMMED EDGE & 10% <br />'cv <br />Scale: As Noted <br />I <br />i y <br />, <br />j <br />l fi <br />_ SLOPED HORIZ. LEG <br />i . .__ <br />1/4" MIN. GAP FOR VENTING <br />PERMIT SET <br />1/4"MIN GAP FOR VENTING <br />l � <br />SIDING PER DESIGN DOCS <br />Drawn By: <br />JMM <br />Checked <br />Chec a By: <br />DDBDF <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />WRB PER DESIGN DOCS I T Y <br />Issue Date: <br />Sheet Number: <br />EX. SHEATHING REVIEWED FOR PERMIT <br />03/24/20 <br />A7 <br />Job #: <br />7 /A7.1 <br />TRIM AT INSIDE CORNER -BRICK VENEER TO TYPICAL SIDING <br />ID: 433 <br />8 /A7.1 <br />THRU-WALL FLASHING -PANEL SIDING <br />ID: 62 <br />9 /A7.1 TBELLY <br />BAND -TYPICAL SIDING <br />ID; 61 <br />0580216 <br />■ <br />SCALE: NTS <br />SC E: NTS <br />SCALE: NTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.