My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2824 GRAND AVE 2020 NAUTICA CONDOMINIUMS Plans 2022-11-08
>
Address Records
>
GRAND AVE
>
2824
>
NAUTICA CONDOMINIUMS
>
Plans
>
2824 GRAND AVE 2020 NAUTICA CONDOMINIUMS Plans 2022-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 10:32:20 AM
Creation date
6/16/2022 9:33:15 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2824
Tenant Name
NAUTICA CONDOMINIUMS
Permit
B2004-009
Year
2020
Notes
REPLACE SIDING, TRIM, WINDOWS, SLIDING GLASS DOORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />WRB FIELD LAYER LAPS METAL FLASHING, APPLY SEALANT/TAPE AT WRB TERMINATIONS <br />EX. SHEATHING <br />6" SAF OVER TOP OF METAL, TYP. <br />SAF PRE -STRIP, LAP ONTO CONC. FOR <br />METAL-TO-CONC. SEPARATION <br />MIN 24 GA MTL. FLASHING (PRIMED & PAINTED) WITH HEMMED FRONT EDGE, SET IN <br />SEALANT(ALSO SET HORIZONTAL LEG IN SEALANT). MIN 10 DEGREE SLOPE PRESSURE FIT <br />DRAINABLE INSECT PROOF STRIP <br />BACKER ROD & SEALANT @ BASE -OF -WALL GAP BETWEEN SHEATHING & CONC. IF <1/2" <br />ENSURE POSITIVE SLOPE THAT DRAINS AWAY FROM THE BUILDING <br />EXISTING CONCRETE PAD <br />EXISTING <br />STRUCTURE <br />SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM, PER DESIGN DOCS <br />WRB FIELD LAYER LAPS METAL FLASHING. <br />APPLY SEALANT BETWEEN WRB & SAF <br />EX. WALL SHEATHING <br />6" SAF OVER TOP OF METAL, TYP. <br />PRE -STRIP WRB, ALLOW AN EXCESS OF WRB TO HANG BELOW <br />WALL SHEATHING FOR A SEPARATION LAYER BETWEEN THE <br />METAL FLASHING AND CONC. STEM WALL <br />DRAINABLE INSECT PROOF STRIP <br />MIN. 24 GA PRESSURE FIT MTL FLASHING W/ HEMMED <br />DRIP EDGE, PRESSURE FIT TO WRB/FOUNDATION <br />WRB BED IN SEALANT OR PROVIDE SAF SEALED TO WRB <br />AND CONCRETE <br />PAINT CONCRETE PER SPECIFICATIONS IF PREVIOUSLY <br />PAINTED <br />VENT SOFFITS ONLY IF UNCONDITIONED SPACE ABOVE <br />SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />WRB PER DESIGN DOCS, APPLY SEALANT/TAPE AT WRB <br />TERMINATIONS <br />EX. SHEATHING <br />EX. INSULATION & FRAMING <br />PRE -WRAP WRB PER DESIGN DOCS <br />6" SAF PER DESIGN DOCS <br />DRAINABLE INSECT PROOF STRIP <br />SEALANT BETWEEN WRB AND SAF <br />1/4" MIN. DRAINAGE GAP <br />�— MTL DRIP EDGE WITH 4" LEG <br />SEALANT PER DESIGN DOCS <br />FIBER CEMENT SOFFIT OVER DENSGLASS <br />1 /A7.2 BASE OF WALL AT HARDSCAPE - TYPICAL SIDING / PEDESTRIAN TRAFFIC COATING 1D 2 /A7.2 BASE OF WALL AT CONCRETE SLAB -TYPICAL SIDING 3 A7.2 GWB/FIBER CEMENT SOFFIT -TYPICAL SIDING <br />SCALE: NTS SCALE: NTS SCALE: NTS <br />F <br />SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM PER DESIGN DOCS, TYP. <br />WRB PER DESIGN DOCS <br />SAF PER DESIGN DOCS <br />WRB PRE STRIP BEHIND FLASHING <br />MTL FLASHING W/ 4" BACK LEG, 1-1/2' DOWN LEG W/ HEM & NO DRIP EDGE <br />1/4" MIN. GAP <br />EX. HANDRAIL,TO BE REMOVED AND REINSTALLED <br />n� <br />5/4x6" MIN. FIBER CEMENT MOUNTING BLOCK <br />SEALANT, FILLET JOINT <br />NEW 2x6 MIN. BLOCKING OR VERIFY SOLID <br />FRAMING OF MOUNTING BLOCK LOCATION <br />SIDING PER DESIGN DOCS <br />WRB PER DESIGN DOCS <br />SHEATHING PER DESIGN DOCS <br />VENT SOFFITS ONLY IF UNCONDITIONED SPACE ABOVE <br />VENTED FIBER CEMENT SOFFIT OVER DENSGLASS <br />SEALANT PER DESIGN DOCS <br />TOP OF WALL FLASHING TRIM <br />1/4" MIN GAP FOR VENTILATION <br />C <br />PROVIDE CONTINUOUS SEALANT BEAD AT TERMINATION <br />POINTS OF WRB FOR AIR BARRIER CONTINUITY <br />DRAINABLE INSECT PROOF STRIP PER DESIGN DOCS <br />SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />�— — WRB PER DESIGN DOCS <br />EX. SHEATHING <br />EX. COLUMN <br />WRB PER DESIGN DOCS <br />TRIM PER DESIGN DOCS <br />SEALANT, FILLET JOINT PER DESIGN DOCS, TYP. <br />ID: 424 5 /A7.2 TOP OF WALL AT SOFFIT -TYPICAL SIDING SCALE: NTS 6 A7.2 COLUMN WRAP SCALE NTS <br />4 /A7.2 HANDRAIL/GUARDRAIL MOUNTING BLOCK - TYP. SIDING scALE: NTs <br />SIDING PER DESIGN DOCS <br />DRAINAGE MEDIUM, PER DESIGN DOCS <br />WRB FIELD LAYER LAPS METAL FLASHING. APPLY SEALANT BETWEEN WRB & SAF <br />WALL SHEATHING PER DESIGN DOCS <br />6" SAF OVER TOP OF METAL, TYP. <br />PRE -STRIP WRB, ALLOW AN EXCESS OF WRB TO HANG BELOW WALL SHEATHING FOR A <br />SEPARATION LAYER BETWEEN THE METAL FLASHING AND CONC. STEM WALL <br />DRAINABLE INSECT PROOF STRIP <br />MIN. 24 GA PRESSURE FIT MTL FLASHING W/ HEMMED DRIP EDGE, PRESSURE FIT TO WRB/FOUNDATION <br />TRANSLUCENT SILICONE SEALANT PER <br />DESIGN DOCS <br />SEALANT PER DESIGN DOCS <br />NEW FLASHING FLASHING SET IN SEALANT <br />EX. BRICK <br />1 7 / A7.2 I BASE OF WALL AT CONCRETE SLAB AND BRICK VENEER INTERSECTION <br />ISOMETRIC <br />LOCATION OF <br />TRANSLUCENT SILCONE <br />SEALANT <br />1. REMOVE EXISTING COPING <br />2. REMOVE VERTICAL GROUT JOINT BETWEEN BRICK <br />AND CONCRETE, INSTALL BACKER ROD AND SEALANT <br />3. INSTALL TRANSLUCENT SILICONE SEALANT <br />4. INSTALL NEW FLAT SEAM MTL COPING <br />5. INSTALL FILLET SEALANT AT COPING TO BUILDING <br />INTERSECTION <br />INSTALL NEW <br />FILLET BEAD <br />SEALANT AFl <br />NEW STANDII <br />SEAM COPIN, <br />BEEN INSTAL <br />Y <br />a` <br />m <br />w <br />z <br />0 <br />8 /A7.2 I PARAPET WALL AT BRICK AND CONCRETE WALL INTERSECTION <br />'E GROUT, <br />LBACKEROD <br />:ALANT <br />ION OF TRANSLUCENT <br />IE SEALANT <br />CITY OF EVERETT' <br />REVIEWED D FOR PER 1`11" <br />Copyright © 2018 All rights reserved. <br />J2 Building Consultants, Inc. <br />8425 44th Ave. W. <br />Mukilieo, WA 98275 <br />Tel 425.774.5600 <br />Fax 425.774.5661 <br />www.J2Consultants.com <br />The undersigned has provided building enclosure <br />documents that in my professional judgement are <br />appropriate to satisfy the requirements of RCW <br />64.55.005 through 64.55.090 <br />12495 �— <br />REGISTERED <br />ARCHITECT <br />10FBFAJARDOSTATWASHINGTON <br />NOTES: <br />1. CONTRACTOR IS RESPONSIBLE <br />FOR FIELD VERIFICATION OF <br />SIZING AND QUANTITIES OF ALL <br />COMPONENTS. <br />2. MOCK UP REVIEW OF ALL <br />EXTERIOR ASSEMBLIES <br />REQUIRED BEFORE INSTALLATION. <br />3. DRAWINGS ARE DIAGRAMMATIC <br />ONLY AND ARE NOT TO BE USED <br />FOR TAKE OFF QUANTITIES. <br />Revisions: <br />Date <br />Project Title: <br />NAUTICA CONDOMINIUMS <br />BUILDING ENVELOPE <br />2818 GRAND AVENUE <br />EVERETT WA 98201 <br />2818 GRAND AVENUE <br />EVERETT WA 98201 <br />Sheet Title: <br />WALL <br />DETAILS <br />Scale: As Noted <br />PERMIT SET <br />Drawn By: JMM <br />Checked By: DD/BDF <br />Issue Date: Sheet Number: <br />03/24/20 <br />Job #: 7.2 <br />0580216 <br />
The URL can be used to link to this page
Your browser does not support the video tag.