My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2824 GRAND AVE 2020 NAUTICA CONDOMINIUMS Plans 2022-11-08
>
Address Records
>
GRAND AVE
>
2824
>
NAUTICA CONDOMINIUMS
>
Plans
>
2824 GRAND AVE 2020 NAUTICA CONDOMINIUMS Plans 2022-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 10:32:20 AM
Creation date
6/16/2022 9:33:15 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2824
Tenant Name
NAUTICA CONDOMINIUMS
Permit
B2004-009
Year
2020
Notes
REPLACE SIDING, TRIM, WINDOWS, SLIDING GLASS DOORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLAT SEAM <br />FLAT SEAM <br />FLAT SEAM <br />CEDAR SHIM TO PROVIDE SLOPE <br />J2 <br />INTERMITTENT BEADS OF SEALANT <br />COMMON LOCK, HOOK <br />SEAM OR CLINCH LOCK DRAINABLE INSECT PROOF STRIP <br />COMMON LOCK, HOOK <br />COMMON LOCK, HOOK <br />1 1 <br />SEAM OR CLINCH LOCK <br />SEAM OR CLINCH LOCK CEDAR SHIM TO PROVIDE SLOPE <br />LOPE 24 GA. MIN. STANDING SEAM MTL COPING, CONCEALED CLEAT PER <br />MI�0 S <br />Copyright ©2018 All rights reserved. <br />INTERMITTENT BEADS OF SEALANT <br />— DESIGN DOCS. FASTEN W/ #12x2" SCREWS @ 12" O/C MAX. <br />J2 Building Consultants, Inc. <br />SAF PER DESIGN DOCS <br />WATER BLOCK PER MANUFACTURER <br />8425 44th Ave. W. <br />Mukilteo, WA 98275 <br />CEDAR SHIM TO PROVIDE SLOPE <br />SAF PER DESIGN DOCS <br />a . <br />nI� , <br />z ;' METAL FLAT SEAM PARAPET COPING W/ HEMMED DRIP EDGE; HOOK TO <br />: CONCEALED CLIP AT FACE AND THROUGH -FASTEN BACK W/ #12x2" <br />GASKETED SCREW @ 24" O/C MAX AT DECKNVALKWAY FACE <br />Tel 425.774.5600 <br />METAL FLAT SEAM SIDING PARAPET COPING W/ <br />.. <br />.' " <br />#12x2 GASKETED SCREWS @24 0/C <br />Fax <br />Fax 425.774.5661 <br />HEMMED DRIP EDGE, INSTALL WITH INTERMITTENT <br />;; <br />BEADS OF SEALANT <br />�---- WRB PER DESIGN DOCS <br />The undersigned has provided building enclosure <br />_ <br />METAL FLAT SEAM SIDING PARAPET COPING W/ HEMMED DRIP EDGE, <br />r <br />-- DRAINAGE MEDIUM PER DESIGN DOCS <br />INSTALL WITH INTERMITTENT BEADS OF SEALANT <br />' <br />documents that in my professional judgement are <br />SIDING PER DESIGN DOCS <br />appropriate to satisfy the requirements of RCW <br />EX. CONCRETE <br />#12x2" GASKETED SCREWS @24" O/C <br />64.55.005 through 64.55.090 <br />' <br />PRIVATE DECK / WALKWAY STREET 1 COURTYARD <br />12 4 9 5 _._._ <br />REGISTERED <br />ARCHITECT <br />EX. CONCRETE <br />BRIAN FAJARDO <br />TOAASHINGTON <br />1 /A7.3 <br />METAL COPING @ PARAPET - BRICK & CONCRETE <br />2/ A7.3 <br />METAL COPING@ PARAPET - TYP. SIDING & CONCRETE <br />1D: <br />3/ A7.3 <br />METAL COPING PARAPET - TYP. SIDING <br />ID: <br />NOTES: <br />SCALE: NT <br />SCALE: NTS <br />SCALE: NTS <br />1. CONTRACTOR IS RESPONSIBLE <br />FOR FIELD VERIFICATION OF <br />SIZING AND QUANTITIES OF ALL <br />SHIM, SAF AND COPING TO BE INSTALLED <br />COMPONENTS. <br />SIDING PER DESIGN DOCS <br />POST CLADDING INSTALL <br />WRB PER DESIGN DOCS <br />2. MOCK UP REVIEW OF ALL <br />SEALANT PER DESIGN DOCS, FILLET JOINT <br />EXTERIOR ASSEMBLIES <br />5/4" FIBER CEMENT TRIM, INSTALLED BY SIDER <br />REQUIRED BEFORE INSTALLATION. <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />TRIM PER DESIGN DOCS <br />SHIM TO BE INSTALLED BY ROOFER <br />SAF TO BE INSTALLED BY ROOFER <br />3. DRAWINGS ARE DIAGRAMMATIC <br />ONLY AND ARE NOT TO BE USED <br />----- SEALANT PER DESIGN DOCS <br />TRANSLUCENT SILCONE <br />SEALANT "BOOT" INSTALL AT <br />FOR TAKE OFF QUANTITIES. <br />TRANSLUCENT SILICONE SEALANT PER DESIGNINTERSECTIONS <br />IUD <br />OF <br />CONCRETE WALL TO SIDING, <br />- ...__ <br />DOCS, INSTALL AT INTERSECTION OF CONCRETE <br />GUARD WALL TO SIDING AT EA. SIDE. <br />TOP TO BOTTOM, ALONG TOP <br />DRAINABLE INSECT PROOF STRIP `- "'• NEW COPING TO BE INSTALLED BY ROOFER <br />4" <br />OF CONCRETE WALL, AND; <br />DOWN EXPOSED SIDES 1" <br />EX. ROOF ASSEMBLY <br />oll <br />" <br />•� <br />I I <br />Revisions: <br />( <br />WRB TO BE INSTALLED BY SIDER, EXTEND 4" MIN OVER <br />EX. CONCRETE GUARDRAIL WALL <br />I <br />TOP OF PARAPET <br />� <br />, <br />I <br />*, <br />y� <br />Date Description <br />_ BACKER ROD AND SEALANT <br />4 " <br />SIDING PER <br />" <br />I I <br />DESIGN DOGS <br />METAL J TRIM PER DESIGN DOCS <br />, <br />I <br />EX. SHEATHING TYP. <br />SIDING PER DESIGN DOCS <br />I I <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />EX. INSULATION & FRAMING ; <br />EX. SHEATHING, FRAMING AND INSULATION <br />IA <br />( I <br />4 A7.3 <br />/ <br />CONCRETE GUARDRAIL WALL TO SIDING <br />1D <br />5 A7.3 <br />/ <br />CONCRETE GUARDRAIL WALL TO SIDING <br />ID <br />6 A7.3 <br />/ <br />METAL COPING PARAPET -SINGLE PLY ROOF <br />@ <br />ID:117 <br />SCALE: NT <br />SCALE:. NTS <br />SCALE: NTS <br />INSTALL TRIM AT BASE OF WALL AT COURTYARD <br />ENTRANCE DOOR OF BUILDING B2818 <br />���` N� <br />NOTE: THIS CONDITION OCCURS ON BUILDING A 2824 FAST ELEVATION <br />*� � `00 2" MIN SPACE FROM ROOF <br />TOP TO SIDING MATERIAL TYP. <br />NEW PRE -FINISHED MTL STANDING <br />Project Title: <br />Y <br />SEAM COPING <br />SIDING PER DESIGN DOCS <br />'` - <br />` N <br />r -- NEW OR EX. STEP FLASHING <br />NAUTICA CONDOMINIUMS <br />WRB FIELD LAYER <br />-f'f <br />w <br />BUILDING ENVELOPE <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />!p ROOFING AND UNDERLAYMENT PER DESIGN DOCS <br />°� <br />�'` NEW ROOF COATING <br />'cc- <br />2818 GRAND AVENUE <br />_-- <br />1 <br />- % <br />UNDERLAYMENT TO ROLL UP WALL 8 <br />r <br />PER DESIGN DOCS <br />EVERETT WA 98201 <br />—_r-� —— WRB PRESTRIP`. <br />WEATHER RESISTIVE BARRIER OVER FLASHING W/ Z MIN. <br />" <br />LAP. SEALANT BETWEEN WRB AND ROOFING <br />a: EX. ROOF MATERIAL <br />PREPARED PER NEW <br />2818 GRAND AVENUE <br />EVERETT WA 98201 <br />f <br />` <br />6" SAF OVER FLASHING <br />DRAINABLE INSECT PROOF STRIP <br />' UNDERLAYMENT <br />! - <br />EX. WRB TO EXTEND 12" MIN. PAST NEW WRB ROOF MATERIAL <br />REQUIREMENTS <br />EX. MTL FLASHING; EXTEND BOTTOM <br />Sheet Title: <br />/ l : <br />WALL SHEATHING PER DESIGN DOCS <br />LEG 2" MIN. PAST T/O SIDING <br />3/8"MIN DRAINAGE GAP <br />NEW PRE FINISHED METAL HEAD FLASHING W/ 4" BACK LEG, <br />HEMMED DRIP EDGE, FOLDED END DAMS & SLOPING <br />; ��✓ PUNCH -LOCKED AND SEALED KICK OUT DIVERTER <br />1/4"MIN. GAP FOR VENTILATION <br />DRAINABLE INSECT PROOF STRIP <br />WALL <br />HORIZONTAL LEG <br />`� FLASHING INSERT UNDER NEW WRB ABOVE AND <br />-- - <br />DETAILS <br />i _ z <br />-' OVER NEW WRB BELOW <br />, <br />SIDING PER DESIGN DOCS i <br />"L" METAL TUCKED UNDER EAVE FLASHING AND SHINGLED <br />_ _.__.__.__.__ _ .__.__ __ <br />WRB PER DESIGN DOCS .--' - -_ <br />TRIM PER DESIGN DOCS <br />INTO SAF AT WALL <br />EX. SHEATHING TYP. <br />Scale: As Noted <br />{ ? z <br />r 12" SAF BEHIND DIVERTER FLASHING INSTALLED IN SHINGLE <br />PERMIT SET <br />N <br />FASHION W/ WRB. BEND SAF OUT AROUND FASCIA AND <br />COVER W/ "L" METAL <br />DRAINAGE MEDIUM PER DESIGN DOCS <br />EX. INSULATION & FRAMING ; <br />f � <br />l WRB CONTINUOUS BEHIND FASCIA <br />Drawn By: <br />JMM <br />4 <br />Checked By: <br />DDBDF <br />SEALANT PER DESIGN DOCS <br />Issue Date: <br />Sheet Number: <br />FIBER CEMENT SOFFIT OVER DENSGLASS <br />C ITS" OF EVERETT <br />REVIEWED FOR PERMIT <br />03/24/20 <br />A7.3 <br />Job #: <br />7 /A7.3 <br />BASE OF WALL AT SOFFIT - TYP SIDING <br />8 /A7.3[ROOF <br />DIVERTER FLASHING - COMP ROOF W/ TYPICAL SIDING <br />9 /A7.3 <br />ROOF TO PARAPET AT EXISTING ROOFING <br />ID: <br />0580216 <br />SCALE: NTS <br />SCALE: NTS <br />S NT <br />
The URL can be used to link to this page
Your browser does not support the video tag.