1717 13TH ST 2021 Plans 2022-12-01
>
Address Records
>
13TH ST
>
1717
>
Plans
>
1717 13TH ST 2021 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:20:47 AM
Creation date
6/21/2022 3:26:33 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1717
Permit
B2107-050
Year
2021
Notes
REPLACE TOMOGRAPHY UNIT AND LINEAR ACCELERATOR UNIT WITH NEW
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R <br />m <br />T UE EA (LI AC) CONDUIT SCHEDULE <br />VARIAN REQUIREMENTS <br />SITE SPECIFIC RACEWAYS <br />Conduit <br />EXISTING PATHWAYS <br />NEW PATHWAYS <br />NOTES <br />FROM <br />TO <br />QTY <br />SIZE <br />No. <br />CITY <br />SIZE <br />FROM <br />TO <br />CITY SIZE FROM <br />TO <br />CONTROL EQUIPMENT PULL BOX <br />4 <br />4" <br />A <br />3 <br />4" <br />CONTROL ROOM FLOOR <br />EXISTING BASE PULL BOX <br />- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />-- <br />-- <br />-- <br />2 <br />4" <br />CONTROL ROOM FLOOR <br />MODULATOR PULL BOX <br />-- -- -- <br />(1)4"C SPARED, (1)4"C FOR CONDUIT D <br />BASEFRAME PULL BOX <br />MODULATOR PULL BOX <br />3 <br />4" <br />B <br />3 <br />4" <br />MODULATOR PULL BOX <br />EXISTING BASE PULL BOX <br />- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />RELAY JUNCTION BOX <br />2 <br />2" <br />C <br />2 <br />2" <br />RELAY JUNCTION BOX <br />MODULATOR PULL BOX <br />2 2" NEW RELAY JUNCTION BOX <br />EXISTING BASEFRAME PULL BOX <br />NEW PATHWAY <br />1 <br />2" <br />MODULATOR PULL BOX <br />MAIN BREAKER <br />__ __ __ <br />-_ <br />REUSE EXISTING PATHWAY <br />MODULATOR PULL BOX <br />MAIN CIRCUIT BREAKER PANEL <br />2 <br />2" <br />D <br />1 <br />2" <br />BASEFRAME PULL BOX <br />MAIN BREAKER <br />1 2" BASEFRAME PULLBOX <br />MODULATOR PULL BOX <br />REUSE EXISTING PATHWAY TO BASEFRAME PULL BOX, EXTEND PATHWAY TO MODULATOR PULLBOX <br />WARNING LIGHTS <br />1 <br />0.5" <br />E <br />1 <br />0.5" <br />RELAY JUNCTION BOX <br />WARNING LIGHT <br />__ __ __ <br />__ <br />EXTEND EXISTING PATHWAY TO NEW RELAY JUNCTION BOX LOCATION <br />RELAY JUNCTION BOX <br />DOOR INTERLOCKS <br />1 <br />0.5" <br />F <br />1 <br />0.5" <br />RELAY JUNCTION BOX <br />DOOR <br />-- -- -- _ <br />-- <br />EXTEND EXISTING PATHWAY TO NEW RELAY JUNCTION BOX LOCATION <br />1 <br />3" <br />G <br />1 <br />3" <br />DOOR CAVITY <br />ABOVE CEILING OF TREATMENT ROOM <br />1 3" ABOVE CEILING OF TREATMENT ROOM <br />IN -ROOM ACCESSORY PULL BOX <br />EXTEND EXISTING PATHWAY TO NEW IN -ROOM ACCESSORY PULL BOX <br />CONTROL EQUIPMENT PULL BOX <br />H <br />1 <br />3" <br />DOOR CAVITY <br />ABOVE CEILING OF TREATMENT ROOM <br />1 3" ABOVE CEILING OF TREATMENT ROOM <br />IN -ROOM ACCESSORY PULL BOX <br />EXTEND EXISTING PATHWAY TO NEW IN -ROOM ACCESSORY PULL BOX <br />2 <br />2" <br />1 <br />2" <br />OUTLET IN CONTROL ROOM <br />OUTLET ON EAST WALL OF TREATMENT ROOM <br />1 2" OUTLET ON EAST WALL OF TREATMENT ROOM <br />IN -ROOM ACCESSORY PULL BOX <br />EXTEND EXISTING PATHWAY TO NEW IN -ROOM ACCESSORY PULL BOX <br />OPTICAL IMAGING CAMERA <br />1 <br />3" <br />I <br />-_ <br />__ <br />__ <br />__ <br />1 3" <br />OPTICAL IMAGING CAMERA <br />NEW PATHWAY <br />IN -ROOM ACCESSORY <br />IN -ROOM MONITORS <br />1 <br />2" <br />J <br />-- <br />__ <br />__ <br />__ <br />1 2" <br />IN -ROOM MONITORS <br />NEW PATHWAY <br />PULL BOX <br />LIVE VIEW CAMERA <br />2 <br />1.25" <br />K <br />-- <br />-- <br />- <br />-- <br />2 1.25" <br />LIVE VIEW CAMERA <br />NEW PATHWAY <br />MICROPHONE <br />1 <br />1.25" <br />L <br />-- <br />-- <br />-- <br />-- <br />1 1" IN -ROOM ACCESSORY PULL BOX <br />MICROPHONE <br />NEW PATHWAY <br />CCTV CAMERAS <br />1 <br />1" <br />M <br />-- <br />-- <br />-- <br />-- <br />4 1.25" <br />CCTV CAMERAS <br />(4) CCTV CAMERAS; NEW PATHWAYS <br />SPEAKERS <br />1 <br />V, <br />N <br />-- <br />-- <br />-- <br />-- <br />2 1" <br />SPEAKERS <br />(2) SPEAKERS; NEW PATHWAYS <br />SERVICE KEYBOARD <br />1 <br />1" <br />O <br />-- <br />-- <br />-- <br />-- <br />1 1" <br />SERVICE KEYBOARD <br />NEW PATHWAY <br />MAIN CIRCUIT <br />CONTROL EQUIPMENT PULL BOX <br />1 <br />2" <br />P <br />-- <br />-- <br />-- <br />-- <br />1 2 <br />CONTROL EQUIPMENT PULL BOX <br />NEW PATHWAY <br />MAIN CIRCUIT BREAKER PANEL <br />BREAKER PANEL <br />IEC 60309, 30A, 250V RECEPTACLE <br />1 <br />PER CODE <br />Q <br />-- <br />-- <br />-- <br />-- <br />1 SEE DWG <br />IEC 60309, 30A, 250V RECEPTACLE <br />NEW PATHWAY <br />NETWORK <br />1 <br />1" <br />R <br />-- <br />-- <br />-- <br />-- <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />EXPERIMENTAL <br />TREATMENT ROOM <br />1 <br />3" <br />S <br />1 <br />3" <br />CONTROL ROOM <br />EAST WALL OF TREATMENT ROOM <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />(PHYSICS) ACCESS <br />LINAC COMMITL ® REFER TO SHEET E6.1- <br />ACCURAY(T ) CONDUIT SCHEDULE <br />ACCUAY REQUIREMENTS <br />SITE SPECIFIC RACEWAYS <br />Conduit <br />EXISTING <br />PATHWAYS <br />NEW PATHWAYS <br />NOTES <br />FROM <br />TO <br />CITY <br />SIZE <br />No. <br />CITY <br />SIZE <br />FROM <br />TO <br />QTY SIZE FROM <br />TO <br />MAIN DISCONNECT <br />EPO <br />1 <br />0.5" <br />1 <br />1 <br />0.5" <br />MAIN DISCONNECT <br />EPO <br />-- - -- <br />-- <br />REUSE EXISTING PATHWAY <br />(MP) <br />PDU <br />1 <br />2" <br />2 <br />1 <br />?? <br />MAIN DISCONNECT <br />EPO <br />- -- -- <br />-- <br />REUSE_ EXISTING PATHWAY <br />EPO <br />1 <br />0.5" <br />3 <br />1 <br />0.5" <br />PDU (JB1) <br />EPO <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />WARNING LIGHTS <br />1 <br />0.75" <br />4 <br />1 <br />0.5" <br />PDU (JB1) <br />WARNING LIGHTS <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />DOOR SWITCH <br />1 <br />0.5" <br />5 <br />1 <br />0.5" <br />PDU (JB1) <br />DOOR SWITCH <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />1 <br />1" <br />PDU (JB1) <br />EXISITNG DORADO J-BOX <br />- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />DORADO LASERS <br />1 <br />1" <br />6 <br />3 <br />1" <br />EXISTING DORADO J-BOX <br />DORADO LASERS <br />- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />2 <br />1" <br />DORADO LASERS <br />DORADO LASERS <br />- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />PDU (JB1) <br />GROUNDING <br />7 <br />-- -_ __ <br />-- <br />REUSE EXISTING PATHWAY <br />SEE <br />GANTRY (JB5) <br />4 <br />4" <br />11 <br />1 <br />PDU (JB1) <br />GANTRY (1135) <br />- - - <br />-- <br />REUSE EXIST ING WIREWAY <br />DWG <br />CONTROL ROOM <br />1 <br />2" <br />A <br />1 <br />2" <br />PDU (JB1) <br />CONTROL ROOM <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />CONTROL ROOM <br />1 <br />2" <br />B <br />1 <br />2" <br />PDU (JB2) <br />CONTROL ROOM <br />_e __ __ <br />-- <br />REUSE EXISTING PATHWAY <br />1 <br />1.5" <br />PDU (JB1) <br />6" ABOVE DROP CEILING <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />DORADO LASERS <br />1 <br />1.5" <br />E <br />2 <br />1.5" <br />6" ABOVE DROP CEILING <br />DORADO LASERS <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />CONTROL ROOM <br />1 <br />1" <br />$ <br />- <br />__ <br />__ <br />__ <br />1 1" <br />CONTROL ROOM <br />NEW PATHWAY <br />INTERCOM <br />INTERCOM <br />BACK OF GANTRY (JB5) <br />1 <br />1" <br />G <br />-- <br />-- <br />1 1" <br />BACK OF GANTRY (JB5) <br />NEW PATHWAY <br />1 <br />3" <br />C <br />1 <br />3" <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />PATIENT TABLE (JB2) <br />BACK OF GANTRY (JB5) <br />PATIENT TABLE (JB2) <br />BACK OF GANTRY (JB5) <br />1 <br />3" <br />D <br />1 <br />2" <br />-- -- -- <br />-- <br />REUSE EXISTING PATHWAY <br />PHYSICS PORT <br />TREATMENT ROOM <br />1 <br />4" <br />F <br />1 <br />4" <br />PHYSICS PORT <br />TREATMENT ROOM <br />-_ __ __ <br />-- <br />REUSE EXISTING PATHWAY <br />TOMO IT a <br />'" <br />ntec- <br />00 194fh Sfreef SW Suife 400 <br />0. <br />Y <br />