2
<br />y'-
<br />Stantec
<br />Panel
<br />Name
<br />D1NH2 277/480V
<br />3 PH 4W
<br />400A
<br />Main lugs only
<br />Type: Panelboard
<br />Location:
<br />Main Electrical Room #0636
<br />Surface Mounted
<br />65,000 AIC
<br />Serves:
<br />Feed Thru Lugs
<br />#
<br />Description
<br />Load
<br />CB
<br />*
<br />A
<br />113
<br />IC
<br />CB
<br />*
<br />Load
<br />Description
<br />#
<br />1#
<br />Mech PP-1, PUMP ROOM
<br />0.30
<br />15/3
<br />CB
<br />X
<br />15/3 CB
<br />1.27
<br />Mech AC-1, PUMP ROOM
<br />2*#
<br />3#
<br />-------PP-1, PUMP ROOM
<br />0.30
<br />-------
<br />---
<br />X
<br />------- ---
<br />1.27
<br />-------AC-1, PUMP ROOM
<br />4*#
<br />5#
<br />-------PP-1, PUMP ROOM
<br />0.30
<br />-------
<br />---
<br />X
<br />------- ---
<br />1.27
<br />-------AC-1, PUMP ROOM
<br />6*#
<br />7#
<br />Mech PP-2, PUMP ROOM
<br />0.30
<br />15/3
<br />CB
<br />X
<br />30/3 CB
<br />4.07
<br />Mech MV-1 (DUPLEX), FAN ROOM
<br />8#
<br />=9#---PP-2,
<br />PUMP ROOM
<br />0.30
<br />-------
<br />--
<br />X
<br />------- ---
<br />4.07
<br />-------MV-1 (DUPLEX), FAN ROOM
<br />10#
<br />11#
<br />-------PP-2, PUMP ROOM
<br />0.30
<br />-------
<br />---
<br />X
<br />------- ---
<br />4.07
<br />-------MV-1 (DUPLEX), FAN ROOM
<br />12#
<br />13#
<br />Mech PP-3, PUMP ROOM
<br />0.30
<br />15/3
<br />CB
<br />X
<br />15/3 CB
<br />0.30
<br />Mech PP-4, PUMP ROOM
<br />14#
<br />15#
<br />-------PP-3, PUMP ROOM
<br />0.30
<br />-------
<br />---
<br />X
<br />------- ---
<br />0.30
<br />-------PP-4, PUMP ROOM
<br />16#
<br />17#
<br />-------PP-3, PUMP ROOM
<br />0.30
<br />------
<br />---
<br />X
<br />------- ---
<br />0.30
<br />-------PP-4, PUMP ROOM
<br />18#
<br />19#
<br />Spare
<br />0.00
<br />25/3
<br />CB
<br />X
<br />15/3 CB
<br />0.94
<br />Mech DPAC, PUMP ROOM
<br />20#
<br />21#
<br />-___--
<br />0.00
<br />-------
<br />---
<br />X
<br />------- ---
<br />0.94
<br />-------DPAC, PUMP ROOM
<br />22#
<br />23#
<br />-------
<br />0.00
<br />-------
<br />---
<br />X
<br />------- ---
<br />0.94
<br />-------DPAC, PUMP ROOM
<br />24#
<br />25#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />50/3 CB
<br />10.12
<br />Mech AC-2, PUMP ROOM [NBNL]
<br />26
<br />27#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />------- ---
<br />10.12
<br />-------AC-2, PUMP ROOM [NBNL]
<br />28
<br />29#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />------- ---
<br />10.12
<br />-------AC-2, PUMP ROOM [NBNL]
<br />30
<br />31#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />O/1
<br />0.00
<br />Space
<br />32
<br />33#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />0/1
<br />0.00
<br />Space
<br />34
<br />35#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />0/1
<br />0.00
<br />Space
<br />36
<br />E
<br />Spare
<br />0.0020/1
<br />CB
<br />X
<br />0/1
<br />0.00
<br />Space
<br />38
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />0/1
<br />0.00
<br />Space
<br />40
<br />41#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />0/1
<br />0.00
<br />Space
<br />42
<br />Rev:
<br />PH A
<br />PH B
<br />PH C
<br />* Circuit Breaker Code
<br />Revised Ckts Marked * Existing Ckts Marked #
<br />Connected KVA
<br />17.61
<br />17.61
<br />17.61
<br />G = GFCI H = HID Rated
<br />S = Shunt Trip C = HACR Rated
<br />File:
<br />R:\client\PRMCE\PEMC COLBY CAMPUS\New
<br />Master
<br />Panel Schedules\Winpanel
<br />(on going schedule)
<br />D = Switching Duty # = See Note
<br />A = AFCI
<br />Notes:
<br />EXISTING PANEL; [NBNL] = NEW BREAKER, NEW LOAD
<br />Dem.
<br />Load Type Conn KVA NEC Demand Factor
<br />KVA Dem. Amps NEC Feed % NEC Feed Amps
<br />Mech
<br />52.82 x 100%
<br />52.82
<br />64 125% of Largest
<br />73
<br />52.82
<br />64 Amps
<br />52.82
<br />64
<br />73
<br />Sta ntec
<br />Panel
<br />Name
<br />D1NL3 120/208V
<br />3 PH 4W
<br />225A Main lugs only
<br />Type: Panelboard
<br />Location:
<br />Main Electrical Room 4OB36
<br />Surface Mounted
<br />10,000 AIC
<br />Serves:
<br />Feed Thru Lugs
<br />#
<br />Description
<br />Load
<br />CB
<br />*
<br />A
<br />B
<br />C
<br />CB
<br />*
<br />Load
<br />Description
<br />#
<br />1#
<br />Recept OB45
<br />0.72
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.20
<br />Equip OB23-COFFEE
<br />2#
<br />3#
<br />Recept OB29
<br />0.72
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.20
<br />Equip OB23-UC REF
<br />4#
<br />5#
<br />Recept OB30
<br />0.90
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.20
<br />Equip OB23-ICE
<br />6#
<br />7#
<br />Equip FIREPLACE
<br />0.40
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.20
<br />Equip OB23-PASTRY CASE
<br />8#
<br />9#
<br />Recept GREETERS DESK
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.60
<br />Equip OB23-POS
<br />10#
<br />11#
<br />Recept HALLWAY
<br />1.08
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.60
<br />Equip OB23-MUSIC
<br />12#
<br />13#
<br />Recept OB18
<br />0.90
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.20
<br />Equip OB23-GRINDER
<br />14#
<br />15#
<br />Recept OB18
<br />0.90
<br />20/1
<br />CB
<br />X
<br />30/2
<br />CB
<br />1.25
<br />Equip OB23-ESPRESSO
<br />16#
<br />174
<br />Recept OB18
<br />0.90
<br />20/1
<br />CB
<br />X
<br />-------
<br />---
<br />1.25
<br />-------OB23-ESPRESSO
<br />18#
<br />19#
<br />Recept CONFERENCE ROOM
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.70
<br />Mech SF-2, FAN ROOM
<br />20#
<br />21#
<br />Recept CONFERENCE ROOM
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.10
<br />Mech 02-1, GARAGE MANIFOLD RM
<br />22#
<br />23#
<br />Recept CONFERENCE ROOM
<br />0.72
<br />-
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.70
<br />Equip OB18-COPIER
<br />24#
<br />25#
<br />Lighting CONCOURSE
<br />0.53
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.60
<br />Mech AD-1, PUMP ROOM
<br />26#
<br />27#
<br />Recept ELEV MACHINE ROOM
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.53
<br />Mech UH-3, LOADING DOCK
<br />28#
<br />29#
<br />Equip 0603 LIGHTING CONTROL
<br />0.38
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.40
<br />(Mech CUH-1, CUH-2, CUH-3
<br />30#
<br />31
<br />Mech DESSICANT DRYER, PUMP ROOM [EBNL]
<br />0.48
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.01
<br />Mech FCU's
<br />32#
<br />33
<br />Mech EF-OB47B, PUMP ROOM [NBNL]
<br />0.83
<br />20/2
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.18
<br />Recept MECHANICAL ROOM
<br />34#
<br />35
<br />-------EF-OB47B, PUMP ROOM [NBNL]
<br />0.83
<br />-------
<br />---
<br />X
<br />20/1
<br />CB
<br />1.20
<br />Equip INSTA HOT OB05
<br />36#
<br />374
<br />Equip POS
<br />0.60
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.86
<br />Mech AD-2, PUMP ROOM
<br />138#
<br />39#
<br />Recept OB31
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.20
<br />Equip LIGHTING CONTROL LCP-LL
<br />40#
<br />414
<br />Equip 01341
<br />0.60
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.25
<br />Lighting
<br />142#
<br />Rev:
<br />PH A
<br />PH B IPH
<br />C
<br />* Circuit Breaker Code
<br />Revised Ckts Marked * Existing Ckts Marked #
<br />Connected KVA
<br />10.57
<br />7.23 111.01
<br />G = GFCI H = HID Rated
<br />S = Shunt Trip C = HACR Rated
<br />File:
<br />R:\client\PRMCE\PEMC COLBY CAMPUS\New Master Panel Schedules\Winpanel
<br />(on going schedule)
<br />D = Switching Duty # = See Note
<br />A = AFCI
<br />Notes:
<br />EXISITNG PANEL; 200% RATED NEUTRAL BUS; [NBNL] = NEW BREAKER,
<br />NEW
<br />LOAD; [EBNL] = EXISTING BREAKER,
<br />NEW LOAD
<br />Dem.
<br />Load Type Conn KVA NEC Demand Factor
<br />KVA Dem. Amps NEC Feed % NEC Feed Amps
<br />Equip
<br />13.78 x 100%
<br />13.78
<br />38 x 100%
<br />38
<br />Lighting
<br />0.77 x 100%
<br />0.77
<br />2 x 125%
<br />3
<br />Mech
<br />6.34 x 100%
<br />6.34
<br />18 125% of Largest
<br />19
<br />Recept
<br />7.92 10 KVA @ 100%,
<br />rest @ 50%
<br />7.92
<br />22 x 100%
<br />22
<br />28.81
<br />80 Amps
<br />28.81
<br />80
<br />]2
<br />Stantec
<br />Panel
<br />Name
<br />D1NL4 120/208V
<br />3 PH 4W
<br />100A Main lugs only
<br />Type: Panelboard
<br />Location:
<br />Main Electrical Room #OB36
<br />Surface Mounted
<br />10,000 AIC
<br />Serves:
<br />Feed Thru Lugs
<br />#
<br />Description
<br />Load
<br />CB
<br />*
<br />A
<br />B IC
<br />CB
<br />*
<br />Load
<br />Description
<br />#
<br />1
<br />Equip 1680, CAMERA, MONITOR, LASERS [EBRL]
<br />0.95
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.70
<br />Equip 1B90-MOTORIZED SHADE
<br />2#
<br />3
<br />Recept 11380 [EBRL]
<br />0.72
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.70
<br />Equip 1B90-MOTORIZED SHADE
<br />4#
<br />5
<br />Equip CAMERA, OPTICAL CAMERA [EBRL]
<br />0.54
<br />20/1
<br />CB
<br />X
<br />i 20/1
<br />CB
<br />1.26
<br />Lighting 1B80
<br />6#
<br />74
<br />Recept 1895
<br />0.36
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.26
<br />Lighting 1B106
<br />8#
<br />9
<br />I<Multi> 1695, WARN LTG, IN RM MONITORS [EBRL]
<br />0.55
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />1.26
<br />Lighting 16116
<br />10#
<br />11
<br />Equip Apollo Laser, 11395 [EBRL]
<br />0.36
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.78
<br />Equip PARK GATE OP AND EXIT VERIFIER
<br />12#
<br />13#
<br />Recept 18106, CAMERAS, MONITOR, LASERS
<br />1.00
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.78
<br />Equip PARK GATE OP AND TICKET DISP
<br />14#
<br />15#
<br />Recept 1B106
<br />0.54
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />16#
<br />17#
<br />Equip Computer
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />18#
<br />19#
<br />Equip 16116, CAMERA MONITOR LASERS
<br />1.00
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />20#
<br />21#
<br />Recept 1_B116
<br />0.54
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />22#
<br />23#
<br />Equip OSMS PWR SUPPLY 1B116
<br />0.60
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />24#
<br />254
<br />Recept BAT, 1B106
<br />0.18
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />26#
<br />27#
<br />Equip 1880 - DOOR OPERATOR
<br />0.86
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />28#
<br />29#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />30#
<br />31#
<br />Equip 1B95 - DOOR OPERATOR
<br />0.86
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />32#
<br />33#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />34#
<br />35#
<br />Equip 1B106 - DOOR OPERATOR
<br />0.86
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />36#
<br />37#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />38#
<br />394
<br />Equip 1B116 - DOOR OPERATOR
<br />0.86
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />40#
<br />41#
<br />Spare
<br />0.00
<br />20/1
<br />CB
<br />X
<br />20/1
<br />CB
<br />0.00
<br />Spare
<br />42#
<br />Rev:
<br />PH A
<br />PH B IPH
<br />C
<br />* Circuit Breaker Code
<br />Revised Ckts Marked * Existing Ckts Marked #
<br />Connected KVA
<br />7.09
<br />6.04
<br />4.51
<br />G = GFCI H = HID Rated
<br />S = Shunt Trip C = HACR Rated
<br />File:
<br />R:\client\PRMCE\PEMC COLBY CAMPUS\New Master
<br />Panel Schedules\Winpanel (on going schedule)
<br />D = Switching Duty # = See Note
<br />I
<br />A = AFCI
<br />Notes:
<br />EXISTING PANEL; 200% RATED NEUTRAL BUS; [EBRL]
<br />= EXISTING BREAKER, REVISED LOAD
<br />Dem.
<br />Load Type Conn KVA NEC Demand Factor
<br />KVA Dem. Amps NEC Feed % NEC Feed Amps
<br />Equip
<br />10.40 x 100%
<br />10.40
<br />29 x 100%
<br />29
<br />Lighting
<br />3.79 x 100%
<br />3.79
<br />11 x 125%
<br />13
<br />Recept
<br />3.52 10 KVA @ 100%, rest @ 50%
<br />3.52
<br />10 x 100%
<br />10
<br />17.71 49 Amps
<br />17.71
<br />49
<br />52
<br />Stantec Panel
<br />Name D2NL1 120/208V 3 PH 4W 400A Main CB Type: Panelboard
<br />Location: Electrical Room #1818 Surface Mounted 10,000AIC
<br />Serves: Single Lugs
<br />#
<br />Description
<br />Load
<br />CB
<br />*
<br />A
<br />B
<br />C
<br />CB
<br />*
<br />Load
<br />Description
<br />#
<br />1#
<br />Recept LVL 1- IS ROOM- CABLE TV HEADENDS
<br />0.36
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.23
<br />Lighting CONCOURSE
<br />2#
<br />3#
<br />Recept LVL 1 - IS ROOM
<br />0.72
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.54
<br />Recept CONTROL ROOM 1839
<br />4#
<br />5#
<br />ReceptTOMO PLANNING 1827
<br />0.36
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.00
<br />Spare
<br />6#
<br />7#
<br />Recept TOMO FILM ANALYSIS EQUIP 1B21
<br />0.81
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.00
<br />Spare
<br />8#
<br />9#
<br />Recept TOMO FILM ANALYSIS EQUIP 1B21
<br />1.00
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.00
<br />Spare
<br />10#
<br />11
<br />Equip TOMO DORADO LASER PWR SUPPLY [NBNL]
<br />0.45
<br />20/2 CB
<br />X
<br />20/1 CB
<br />0.00
<br />Spare
<br />12#
<br />13
<br />-------TOMO DORADO LASER PWR SUPPLY [NBNL]
<br />0.45
<br />------- ---
<br />X
<br />20/2 CB
<br />1.25
<br />Equip TOMO DATA SERVER UNIT [EBRL]
<br />14
<br />15#
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />------- ---
<br />1.25
<br />-------TOMO DATA SERVER UNIT [EBRL]
<br />16
<br />17#
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />20/2 CB
<br />1.25
<br />Equip TOMO DATA SERVER UNIT [EBRL]
<br />18
<br />194
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />------- ---
<br />1.25
<br />-------TOMO DATA SERVER UNIT [EBRL]
<br />20
<br />21#
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />20/2 CB
<br />1.25
<br />Equip TOMO DATA SERVER UNIT [NBNL]
<br />22
<br />23#
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />------- ---
<br />1.25
<br />-------TOMO DATA SERVER UNIT [NBNL]
<br />24
<br />25#
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.00
<br />Spare
<br />26#
<br />27#
<br />Spare
<br />0.00
<br />20/1 CB
<br />X
<br />20/1 C13
<br />0.00
<br />Spare
<br />28#
<br />29#
<br />Mech FCUS
<br />0.44
<br />20/1 CB
<br />X
<br />20/1 CB
<br />0.00
<br />Spare
<br />30#
<br />31#
<br />Mech EF-4, GARAGE P2
<br />0.10
<br />20/1 CB
<br />X
<br />100/3 CB
<br />8.74
<br />Panel D2NL4
<br />32#
<br />33#
<br />Equip PTS
<br />0.60
<br />20/1 CB
<br />X
<br />------- ---
<br />9.98
<br />-------D2NL4
<br />34#
<br />35*#
<br />Equip 1B75 HDR Equipment
<br />1.20
<br />20/1 CB
<br />X
<br />------- ---
<br />6.34
<br />-------D2NL4
<br />36#
<br />37*#
<br />Equip 1B75 Orthovoltage Equipment
<br />4.00
<br />50/2 CB
<br />X
<br />225/3 CB
<br />23.32
<br />Panel D2NL2
<br />38#
<br />39*#
<br />-------1B75 Orthovoltage Equipment
<br />4.00
<br />------- ---
<br />X
<br />------- ---
<br />23.14
<br />-------D2NL2
<br />40#
<br />41#
<br />Recept ELECTRICAL ROOM
<br />0.18
<br />20/1 CB
<br />X
<br />------- ---
<br />22.87
<br />-------D2NL2
<br />42#
<br />Rev:
<br />Revised Ckts Marked * Existing Ckts Marked #
<br />File: R:\client\PRMCE\PEMC COLBY CAMPUS\New Master
<br />PH A
<br />PH B
<br />PH C
<br />* Circuit Breaker Code
<br />G =GFCI H =HID Rated
<br />S = Shunt Trip C = HACR Rated
<br />D = Switching Duty # = See Note
<br />A e AFCI
<br />Connected KVA
<br />40.50
<br />42.47
<br />34.34
<br />Panel Schedules\Winpanel
<br />(on going schedule)
<br />Notes: EXISTING PANEL; 200% RATED NEUTRAL BUS; [NBNL] = NEW BREAKER, NEW LOAD; [EBRL] = EXISTING BREAKER,
<br />NEW LOAD
<br />Dem.
<br />Load Type Conn KVA NEC Demand Factor KVA Dem. Amps NEC Feed % NEC Feed Amps
<br />Equip 48.49 x 100% 48.49 135 x 100% 135
<br />Lighting 0.22 x 100% 0.22 1 x 125% 1
<br />Mech 0.54 x 100% 0.54 2 125% of Largest 2
<br />Recept 68.05 10 KVA @ 100%, rest @ 50% 39.02 108 x 100% 108
<br />117.31 326 Amps 88.29 245 246
<br />Stantec
<br />Panel
<br />Name D2NH1
<br />277/480V 3 PH 4W
<br />225A Main CB
<br />Type: Panelboard
<br />Location: Electrical Room
<br />#1818
<br />Surface Mounted
<br />35,000 AIC
<br />Serves:
<br />Single Lugs
<br />Dem.
<br />Load Type
<br />Conn KVA
<br />NEC Demand Factor
<br />KVA Dem.
<br />Amps
<br />NEC Feed %
<br />NEC Feed Amps
<br />Equip
<br />54.49
<br />x 100%
<br />54.49
<br />66
<br />x 100%
<br />66
<br />Lighting
<br />22.56
<br />x 100%
<br />22.56
<br />27
<br />x 125%
<br />34
<br />Mech
<br />5.05
<br />x 100%
<br />5.05
<br />6
<br />125% of Largest
<br />7
<br />Recept
<br />68.05
<br />10 KVA @ 100%, rest @ 50%
<br />39.02
<br />47
<br />x 100%
<br />47
<br />150.16
<br />181 Amps
<br />121.14
<br />146
<br />153
<br />Stantec
<br />Panel
<br />Name D1NL1
<br />120/208V 3 PH 4W
<br />400A Main CB
<br />Type: Panelboard
<br />Location: Main Electrical
<br />Room #0836
<br />Surface Mounted
<br />10,000 AIC
<br />Serves:
<br />Single Lugs
<br />Dem.
<br />Load Type
<br />Conn KVA
<br />NEC Demand Factor
<br />KVA Dem.
<br />Amps
<br />NEC Feed %
<br />NEC Feed Amps
<br />Equip
<br />42.44
<br />x 100%
<br />42.44
<br />118
<br />x 100%
<br />118
<br />Lighting
<br />5.61
<br />x 100%
<br />5.61
<br />16
<br />x 125%
<br />19
<br />Mech
<br />6.34
<br />x 100%
<br />6.34
<br />18
<br />125% of Largest
<br />19
<br />Misc
<br />2.10
<br />x 100%
<br />2.10
<br />6
<br />x 100%
<br />6
<br />Motors
<br />4.07
<br />x 100%
<br />4.07
<br />11
<br />125% of Largest
<br />12
<br />Recept
<br />47.10
<br />10 KVA @ 100%, rest @ 50%
<br />28.55
<br />79
<br />x 100%
<br />79
<br />107.67
<br />299 Amps
<br />89.12
<br />247
<br />254
<br />Stantec
<br />Name D1NH1 277/480V 3 PH 4W
<br />Location: Main Electrical Room #0836
<br />Serves:
<br />Load Type
<br />Conn KVA
<br />NEC Demand Factor
<br />Equip 48.44
<br />x 100%
<br />Lighting
<br />37.64
<br />x 100%
<br />Mech
<br />94.53
<br />x 100%
<br />Misc
<br />2.10
<br />x 100%
<br />Motors
<br />10.39
<br />x 100%
<br />Recept
<br />47.10
<br />10 KVA @ 100%, rest @ 50%
<br />240.20
<br />289 Amps
<br />Z �
<br />Surface Mounted
<br />Feed Thru Lugs
<br />Dem.
<br />KVA Dem. Amps
<br />NEC Feed %
<br />48.44
<br />58
<br />x 100%
<br />37.64
<br />45
<br />x 125%
<br />94.53
<br />114
<br />125% of Largest
<br />2.10
<br />3
<br />x 100%
<br />1039
<br />12
<br />125% of Largest
<br />28.55
<br />34
<br />x 100%
<br />221.65
<br />267
<br />sm
<br />Type: Panelboard
<br />65,000 AIC
<br />NEC Feed Amps
<br />Sta ntec
<br />Swbd
<br />Name MSB-D
<br />277/480V 3 PH 4W 4000A
<br />Main CB
<br />Type: Switchboard
<br />Location: Main Electrical Room #0036
<br />Surface Mounted
<br />65,000 AIC
<br />Serves:
<br />Single Lugs
<br />Dem.
<br />Dem.
<br />Load Type Conn KVA
<br />NEC Demand Factor
<br />KVA
<br />Amps
<br />NEC Feed %
<br />NEC Feed Amps
<br />Equip 108.59
<br />x 100%
<br />108.59
<br />131
<br />x 100%
<br />131
<br />Lighting 0.01
<br />x 100%
<br />0.01
<br />0
<br />x 125%
<br />0
<br />Mech 32.49
<br />x 100%
<br />32.49
<br />39
<br />125% of Largest
<br />48
<br />Recept 0.90
<br />10 KVA @ 100%, rest @ 50%
<br />0.90
<br />1
<br />x 100%
<br />1
<br />Recorded Demand 308.00
<br />x 125%
<br />385.00
<br />463
<br />x 100%
<br />463
<br />* Recorded Demand calculated as 308.00kVA x 100% S.A.F. x 100% O.A.F.
<br />449.99
<br />541 Amps
<br />526.99
<br />634
<br />643
<br />58
<br />57
<br />123
<br />3
<br />14
<br />34
<br />289
<br />2727 Oakes Ave.
<br />sufte t
<br />Ever4 WA 98201
<br />REVISIONS
<br />v
<br />k38180
<br />®� 4' �r
<br />�'8IONAL 7/13/2021
<br />4100 194th Street SW Suite 400
<br />Lynnwood Washington 98036-4613
<br />(206)667-0555
<br />CD
<br />7-13-21
<br />r..,,
<br />if,
<br />l� 1