Laserfiche WebLink
2 <br />y'- <br />Stantec <br />Panel <br />Name <br />D1NH2 277/480V <br />3 PH 4W <br />400A <br />Main lugs only <br />Type: Panelboard <br />Location: <br />Main Electrical Room #0636 <br />Surface Mounted <br />65,000 AIC <br />Serves: <br />Feed Thru Lugs <br /># <br />Description <br />Load <br />CB <br />* <br />A <br />113 <br />IC <br />CB <br />* <br />Load <br />Description <br /># <br />1# <br />Mech PP-1, PUMP ROOM <br />0.30 <br />15/3 <br />CB <br />X <br />15/3 CB <br />1.27 <br />Mech AC-1, PUMP ROOM <br />2*# <br />3# <br />-------PP-1, PUMP ROOM <br />0.30 <br />------- <br />--- <br />X <br />------- --- <br />1.27 <br />-------AC-1, PUMP ROOM <br />4*# <br />5# <br />-------PP-1, PUMP ROOM <br />0.30 <br />------- <br />--- <br />X <br />------- --- <br />1.27 <br />-------AC-1, PUMP ROOM <br />6*# <br />7# <br />Mech PP-2, PUMP ROOM <br />0.30 <br />15/3 <br />CB <br />X <br />30/3 CB <br />4.07 <br />Mech MV-1 (DUPLEX), FAN ROOM <br />8# <br />=9#---PP-2, <br />PUMP ROOM <br />0.30 <br />------- <br />-- <br />X <br />------- --- <br />4.07 <br />-------MV-1 (DUPLEX), FAN ROOM <br />10# <br />11# <br />-------PP-2, PUMP ROOM <br />0.30 <br />------- <br />--- <br />X <br />------- --- <br />4.07 <br />-------MV-1 (DUPLEX), FAN ROOM <br />12# <br />13# <br />Mech PP-3, PUMP ROOM <br />0.30 <br />15/3 <br />CB <br />X <br />15/3 CB <br />0.30 <br />Mech PP-4, PUMP ROOM <br />14# <br />15# <br />-------PP-3, PUMP ROOM <br />0.30 <br />------- <br />--- <br />X <br />------- --- <br />0.30 <br />-------PP-4, PUMP ROOM <br />16# <br />17# <br />-------PP-3, PUMP ROOM <br />0.30 <br />------ <br />--- <br />X <br />------- --- <br />0.30 <br />-------PP-4, PUMP ROOM <br />18# <br />19# <br />Spare <br />0.00 <br />25/3 <br />CB <br />X <br />15/3 CB <br />0.94 <br />Mech DPAC, PUMP ROOM <br />20# <br />21# <br />-___-- <br />0.00 <br />------- <br />--- <br />X <br />------- --- <br />0.94 <br />-------DPAC, PUMP ROOM <br />22# <br />23# <br />------- <br />0.00 <br />------- <br />--- <br />X <br />------- --- <br />0.94 <br />-------DPAC, PUMP ROOM <br />24# <br />25# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />50/3 CB <br />10.12 <br />Mech AC-2, PUMP ROOM [NBNL] <br />26 <br />27# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />------- --- <br />10.12 <br />-------AC-2, PUMP ROOM [NBNL] <br />28 <br />29# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />------- --- <br />10.12 <br />-------AC-2, PUMP ROOM [NBNL] <br />30 <br />31# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />O/1 <br />0.00 <br />Space <br />32 <br />33# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />0/1 <br />0.00 <br />Space <br />34 <br />35# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />0/1 <br />0.00 <br />Space <br />36 <br />E <br />Spare <br />0.0020/1 <br />CB <br />X <br />0/1 <br />0.00 <br />Space <br />38 <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />0/1 <br />0.00 <br />Space <br />40 <br />41# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />0/1 <br />0.00 <br />Space <br />42 <br />Rev: <br />PH A <br />PH B <br />PH C <br />* Circuit Breaker Code <br />Revised Ckts Marked * Existing Ckts Marked # <br />Connected KVA <br />17.61 <br />17.61 <br />17.61 <br />G = GFCI H = HID Rated <br />S = Shunt Trip C = HACR Rated <br />File: <br />R:\client\PRMCE\PEMC COLBY CAMPUS\New <br />Master <br />Panel Schedules\Winpanel <br />(on going schedule) <br />D = Switching Duty # = See Note <br />A = AFCI <br />Notes: <br />EXISTING PANEL; [NBNL] = NEW BREAKER, NEW LOAD <br />Dem. <br />Load Type Conn KVA NEC Demand Factor <br />KVA Dem. Amps NEC Feed % NEC Feed Amps <br />Mech <br />52.82 x 100% <br />52.82 <br />64 125% of Largest <br />73 <br />52.82 <br />64 Amps <br />52.82 <br />64 <br />73 <br />Sta ntec <br />Panel <br />Name <br />D1NL3 120/208V <br />3 PH 4W <br />225A Main lugs only <br />Type: Panelboard <br />Location: <br />Main Electrical Room 4OB36 <br />Surface Mounted <br />10,000 AIC <br />Serves: <br />Feed Thru Lugs <br /># <br />Description <br />Load <br />CB <br />* <br />A <br />B <br />C <br />CB <br />* <br />Load <br />Description <br /># <br />1# <br />Recept OB45 <br />0.72 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.20 <br />Equip OB23-COFFEE <br />2# <br />3# <br />Recept OB29 <br />0.72 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.20 <br />Equip OB23-UC REF <br />4# <br />5# <br />Recept OB30 <br />0.90 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.20 <br />Equip OB23-ICE <br />6# <br />7# <br />Equip FIREPLACE <br />0.40 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.20 <br />Equip OB23-PASTRY CASE <br />8# <br />9# <br />Recept GREETERS DESK <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.60 <br />Equip OB23-POS <br />10# <br />11# <br />Recept HALLWAY <br />1.08 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.60 <br />Equip OB23-MUSIC <br />12# <br />13# <br />Recept OB18 <br />0.90 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.20 <br />Equip OB23-GRINDER <br />14# <br />15# <br />Recept OB18 <br />0.90 <br />20/1 <br />CB <br />X <br />30/2 <br />CB <br />1.25 <br />Equip OB23-ESPRESSO <br />16# <br />174 <br />Recept OB18 <br />0.90 <br />20/1 <br />CB <br />X <br />------- <br />--- <br />1.25 <br />-------OB23-ESPRESSO <br />18# <br />19# <br />Recept CONFERENCE ROOM <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.70 <br />Mech SF-2, FAN ROOM <br />20# <br />21# <br />Recept CONFERENCE ROOM <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.10 <br />Mech 02-1, GARAGE MANIFOLD RM <br />22# <br />23# <br />Recept CONFERENCE ROOM <br />0.72 <br />- <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.70 <br />Equip OB18-COPIER <br />24# <br />25# <br />Lighting CONCOURSE <br />0.53 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.60 <br />Mech AD-1, PUMP ROOM <br />26# <br />27# <br />Recept ELEV MACHINE ROOM <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.53 <br />Mech UH-3, LOADING DOCK <br />28# <br />29# <br />Equip 0603 LIGHTING CONTROL <br />0.38 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.40 <br />(Mech CUH-1, CUH-2, CUH-3 <br />30# <br />31 <br />Mech DESSICANT DRYER, PUMP ROOM [EBNL] <br />0.48 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.01 <br />Mech FCU's <br />32# <br />33 <br />Mech EF-OB47B, PUMP ROOM [NBNL] <br />0.83 <br />20/2 <br />CB <br />X <br />20/1 <br />CB <br />0.18 <br />Recept MECHANICAL ROOM <br />34# <br />35 <br />-------EF-OB47B, PUMP ROOM [NBNL] <br />0.83 <br />------- <br />--- <br />X <br />20/1 <br />CB <br />1.20 <br />Equip INSTA HOT OB05 <br />36# <br />374 <br />Equip POS <br />0.60 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.86 <br />Mech AD-2, PUMP ROOM <br />138# <br />39# <br />Recept OB31 <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.20 <br />Equip LIGHTING CONTROL LCP-LL <br />40# <br />414 <br />Equip 01341 <br />0.60 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.25 <br />Lighting <br />142# <br />Rev: <br />PH A <br />PH B IPH <br />C <br />* Circuit Breaker Code <br />Revised Ckts Marked * Existing Ckts Marked # <br />Connected KVA <br />10.57 <br />7.23 111.01 <br />G = GFCI H = HID Rated <br />S = Shunt Trip C = HACR Rated <br />File: <br />R:\client\PRMCE\PEMC COLBY CAMPUS\New Master Panel Schedules\Winpanel <br />(on going schedule) <br />D = Switching Duty # = See Note <br />A = AFCI <br />Notes: <br />EXISITNG PANEL; 200% RATED NEUTRAL BUS; [NBNL] = NEW BREAKER, <br />NEW <br />LOAD; [EBNL] = EXISTING BREAKER, <br />NEW LOAD <br />Dem. <br />Load Type Conn KVA NEC Demand Factor <br />KVA Dem. Amps NEC Feed % NEC Feed Amps <br />Equip <br />13.78 x 100% <br />13.78 <br />38 x 100% <br />38 <br />Lighting <br />0.77 x 100% <br />0.77 <br />2 x 125% <br />3 <br />Mech <br />6.34 x 100% <br />6.34 <br />18 125% of Largest <br />19 <br />Recept <br />7.92 10 KVA @ 100%, <br />rest @ 50% <br />7.92 <br />22 x 100% <br />22 <br />28.81 <br />80 Amps <br />28.81 <br />80 <br />]2 <br />Stantec <br />Panel <br />Name <br />D1NL4 120/208V <br />3 PH 4W <br />100A Main lugs only <br />Type: Panelboard <br />Location: <br />Main Electrical Room #OB36 <br />Surface Mounted <br />10,000 AIC <br />Serves: <br />Feed Thru Lugs <br /># <br />Description <br />Load <br />CB <br />* <br />A <br />B IC <br />CB <br />* <br />Load <br />Description <br /># <br />1 <br />Equip 1680, CAMERA, MONITOR, LASERS [EBRL] <br />0.95 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.70 <br />Equip 1B90-MOTORIZED SHADE <br />2# <br />3 <br />Recept 11380 [EBRL] <br />0.72 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.70 <br />Equip 1B90-MOTORIZED SHADE <br />4# <br />5 <br />Equip CAMERA, OPTICAL CAMERA [EBRL] <br />0.54 <br />20/1 <br />CB <br />X <br />i 20/1 <br />CB <br />1.26 <br />Lighting 1B80 <br />6# <br />74 <br />Recept 1895 <br />0.36 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.26 <br />Lighting 1B106 <br />8# <br />9 <br />I<Multi> 1695, WARN LTG, IN RM MONITORS [EBRL] <br />0.55 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />1.26 <br />Lighting 16116 <br />10# <br />11 <br />Equip Apollo Laser, 11395 [EBRL] <br />0.36 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.78 <br />Equip PARK GATE OP AND EXIT VERIFIER <br />12# <br />13# <br />Recept 18106, CAMERAS, MONITOR, LASERS <br />1.00 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.78 <br />Equip PARK GATE OP AND TICKET DISP <br />14# <br />15# <br />Recept 1B106 <br />0.54 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />16# <br />17# <br />Equip Computer <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />18# <br />19# <br />Equip 16116, CAMERA MONITOR LASERS <br />1.00 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />20# <br />21# <br />Recept 1_B116 <br />0.54 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />22# <br />23# <br />Equip OSMS PWR SUPPLY 1B116 <br />0.60 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />24# <br />254 <br />Recept BAT, 1B106 <br />0.18 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />26# <br />27# <br />Equip 1880 - DOOR OPERATOR <br />0.86 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />28# <br />29# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />30# <br />31# <br />Equip 1B95 - DOOR OPERATOR <br />0.86 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />32# <br />33# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />34# <br />35# <br />Equip 1B106 - DOOR OPERATOR <br />0.86 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />36# <br />37# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />38# <br />394 <br />Equip 1B116 - DOOR OPERATOR <br />0.86 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />40# <br />41# <br />Spare <br />0.00 <br />20/1 <br />CB <br />X <br />20/1 <br />CB <br />0.00 <br />Spare <br />42# <br />Rev: <br />PH A <br />PH B IPH <br />C <br />* Circuit Breaker Code <br />Revised Ckts Marked * Existing Ckts Marked # <br />Connected KVA <br />7.09 <br />6.04 <br />4.51 <br />G = GFCI H = HID Rated <br />S = Shunt Trip C = HACR Rated <br />File: <br />R:\client\PRMCE\PEMC COLBY CAMPUS\New Master <br />Panel Schedules\Winpanel (on going schedule) <br />D = Switching Duty # = See Note <br />I <br />A = AFCI <br />Notes: <br />EXISTING PANEL; 200% RATED NEUTRAL BUS; [EBRL] <br />= EXISTING BREAKER, REVISED LOAD <br />Dem. <br />Load Type Conn KVA NEC Demand Factor <br />KVA Dem. Amps NEC Feed % NEC Feed Amps <br />Equip <br />10.40 x 100% <br />10.40 <br />29 x 100% <br />29 <br />Lighting <br />3.79 x 100% <br />3.79 <br />11 x 125% <br />13 <br />Recept <br />3.52 10 KVA @ 100%, rest @ 50% <br />3.52 <br />10 x 100% <br />10 <br />17.71 49 Amps <br />17.71 <br />49 <br />52 <br />Stantec Panel <br />Name D2NL1 120/208V 3 PH 4W 400A Main CB Type: Panelboard <br />Location: Electrical Room #1818 Surface Mounted 10,000AIC <br />Serves: Single Lugs <br /># <br />Description <br />Load <br />CB <br />* <br />A <br />B <br />C <br />CB <br />* <br />Load <br />Description <br /># <br />1# <br />Recept LVL 1- IS ROOM- CABLE TV HEADENDS <br />0.36 <br />20/1 CB <br />X <br />20/1 CB <br />0.23 <br />Lighting CONCOURSE <br />2# <br />3# <br />Recept LVL 1 - IS ROOM <br />0.72 <br />20/1 CB <br />X <br />20/1 CB <br />0.54 <br />Recept CONTROL ROOM 1839 <br />4# <br />5# <br />ReceptTOMO PLANNING 1827 <br />0.36 <br />20/1 CB <br />X <br />20/1 CB <br />0.00 <br />Spare <br />6# <br />7# <br />Recept TOMO FILM ANALYSIS EQUIP 1B21 <br />0.81 <br />20/1 CB <br />X <br />20/1 CB <br />0.00 <br />Spare <br />8# <br />9# <br />Recept TOMO FILM ANALYSIS EQUIP 1B21 <br />1.00 <br />20/1 CB <br />X <br />20/1 CB <br />0.00 <br />Spare <br />10# <br />11 <br />Equip TOMO DORADO LASER PWR SUPPLY [NBNL] <br />0.45 <br />20/2 CB <br />X <br />20/1 CB <br />0.00 <br />Spare <br />12# <br />13 <br />-------TOMO DORADO LASER PWR SUPPLY [NBNL] <br />0.45 <br />------- --- <br />X <br />20/2 CB <br />1.25 <br />Equip TOMO DATA SERVER UNIT [EBRL] <br />14 <br />15# <br />Spare <br />0.00 <br />20/1 CB <br />X <br />------- --- <br />1.25 <br />-------TOMO DATA SERVER UNIT [EBRL] <br />16 <br />17# <br />Spare <br />0.00 <br />20/1 CB <br />X <br />20/2 CB <br />1.25 <br />Equip TOMO DATA SERVER UNIT [EBRL] <br />18 <br />194 <br />Spare <br />0.00 <br />20/1 CB <br />X <br />------- --- <br />1.25 <br />-------TOMO DATA SERVER UNIT [EBRL] <br />20 <br />21# <br />Spare <br />0.00 <br />20/1 CB <br />X <br />20/2 CB <br />1.25 <br />Equip TOMO DATA SERVER UNIT [NBNL] <br />22 <br />23# <br />Spare <br />0.00 <br />20/1 CB <br />X <br />------- --- <br />1.25 <br />-------TOMO DATA SERVER UNIT [NBNL] <br />24 <br />25# <br />Spare <br />0.00 <br />20/1 CB <br />X <br />20/1 CB <br />0.00 <br />Spare <br />26# <br />27# <br />Spare <br />0.00 <br />20/1 CB <br />X <br />20/1 C13 <br />0.00 <br />Spare <br />28# <br />29# <br />Mech FCUS <br />0.44 <br />20/1 CB <br />X <br />20/1 CB <br />0.00 <br />Spare <br />30# <br />31# <br />Mech EF-4, GARAGE P2 <br />0.10 <br />20/1 CB <br />X <br />100/3 CB <br />8.74 <br />Panel D2NL4 <br />32# <br />33# <br />Equip PTS <br />0.60 <br />20/1 CB <br />X <br />------- --- <br />9.98 <br />-------D2NL4 <br />34# <br />35*# <br />Equip 1B75 HDR Equipment <br />1.20 <br />20/1 CB <br />X <br />------- --- <br />6.34 <br />-------D2NL4 <br />36# <br />37*# <br />Equip 1B75 Orthovoltage Equipment <br />4.00 <br />50/2 CB <br />X <br />225/3 CB <br />23.32 <br />Panel D2NL2 <br />38# <br />39*# <br />-------1B75 Orthovoltage Equipment <br />4.00 <br />------- --- <br />X <br />------- --- <br />23.14 <br />-------D2NL2 <br />40# <br />41# <br />Recept ELECTRICAL ROOM <br />0.18 <br />20/1 CB <br />X <br />------- --- <br />22.87 <br />-------D2NL2 <br />42# <br />Rev: <br />Revised Ckts Marked * Existing Ckts Marked # <br />File: R:\client\PRMCE\PEMC COLBY CAMPUS\New Master <br />PH A <br />PH B <br />PH C <br />* Circuit Breaker Code <br />G =GFCI H =HID Rated <br />S = Shunt Trip C = HACR Rated <br />D = Switching Duty # = See Note <br />A e AFCI <br />Connected KVA <br />40.50 <br />42.47 <br />34.34 <br />Panel Schedules\Winpanel <br />(on going schedule) <br />Notes: EXISTING PANEL; 200% RATED NEUTRAL BUS; [NBNL] = NEW BREAKER, NEW LOAD; [EBRL] = EXISTING BREAKER, <br />NEW LOAD <br />Dem. <br />Load Type Conn KVA NEC Demand Factor KVA Dem. Amps NEC Feed % NEC Feed Amps <br />Equip 48.49 x 100% 48.49 135 x 100% 135 <br />Lighting 0.22 x 100% 0.22 1 x 125% 1 <br />Mech 0.54 x 100% 0.54 2 125% of Largest 2 <br />Recept 68.05 10 KVA @ 100%, rest @ 50% 39.02 108 x 100% 108 <br />117.31 326 Amps 88.29 245 246 <br />Stantec <br />Panel <br />Name D2NH1 <br />277/480V 3 PH 4W <br />225A Main CB <br />Type: Panelboard <br />Location: Electrical Room <br />#1818 <br />Surface Mounted <br />35,000 AIC <br />Serves: <br />Single Lugs <br />Dem. <br />Load Type <br />Conn KVA <br />NEC Demand Factor <br />KVA Dem. <br />Amps <br />NEC Feed % <br />NEC Feed Amps <br />Equip <br />54.49 <br />x 100% <br />54.49 <br />66 <br />x 100% <br />66 <br />Lighting <br />22.56 <br />x 100% <br />22.56 <br />27 <br />x 125% <br />34 <br />Mech <br />5.05 <br />x 100% <br />5.05 <br />6 <br />125% of Largest <br />7 <br />Recept <br />68.05 <br />10 KVA @ 100%, rest @ 50% <br />39.02 <br />47 <br />x 100% <br />47 <br />150.16 <br />181 Amps <br />121.14 <br />146 <br />153 <br />Stantec <br />Panel <br />Name D1NL1 <br />120/208V 3 PH 4W <br />400A Main CB <br />Type: Panelboard <br />Location: Main Electrical <br />Room #0836 <br />Surface Mounted <br />10,000 AIC <br />Serves: <br />Single Lugs <br />Dem. <br />Load Type <br />Conn KVA <br />NEC Demand Factor <br />KVA Dem. <br />Amps <br />NEC Feed % <br />NEC Feed Amps <br />Equip <br />42.44 <br />x 100% <br />42.44 <br />118 <br />x 100% <br />118 <br />Lighting <br />5.61 <br />x 100% <br />5.61 <br />16 <br />x 125% <br />19 <br />Mech <br />6.34 <br />x 100% <br />6.34 <br />18 <br />125% of Largest <br />19 <br />Misc <br />2.10 <br />x 100% <br />2.10 <br />6 <br />x 100% <br />6 <br />Motors <br />4.07 <br />x 100% <br />4.07 <br />11 <br />125% of Largest <br />12 <br />Recept <br />47.10 <br />10 KVA @ 100%, rest @ 50% <br />28.55 <br />79 <br />x 100% <br />79 <br />107.67 <br />299 Amps <br />89.12 <br />247 <br />254 <br />Stantec <br />Name D1NH1 277/480V 3 PH 4W <br />Location: Main Electrical Room #0836 <br />Serves: <br />Load Type <br />Conn KVA <br />NEC Demand Factor <br />Equip 48.44 <br />x 100% <br />Lighting <br />37.64 <br />x 100% <br />Mech <br />94.53 <br />x 100% <br />Misc <br />2.10 <br />x 100% <br />Motors <br />10.39 <br />x 100% <br />Recept <br />47.10 <br />10 KVA @ 100%, rest @ 50% <br />240.20 <br />289 Amps <br />Z � <br />Surface Mounted <br />Feed Thru Lugs <br />Dem. <br />KVA Dem. Amps <br />NEC Feed % <br />48.44 <br />58 <br />x 100% <br />37.64 <br />45 <br />x 125% <br />94.53 <br />114 <br />125% of Largest <br />2.10 <br />3 <br />x 100% <br />1039 <br />12 <br />125% of Largest <br />28.55 <br />34 <br />x 100% <br />221.65 <br />267 <br />sm <br />Type: Panelboard <br />65,000 AIC <br />NEC Feed Amps <br />Sta ntec <br />Swbd <br />Name MSB-D <br />277/480V 3 PH 4W 4000A <br />Main CB <br />Type: Switchboard <br />Location: Main Electrical Room #0036 <br />Surface Mounted <br />65,000 AIC <br />Serves: <br />Single Lugs <br />Dem. <br />Dem. <br />Load Type Conn KVA <br />NEC Demand Factor <br />KVA <br />Amps <br />NEC Feed % <br />NEC Feed Amps <br />Equip 108.59 <br />x 100% <br />108.59 <br />131 <br />x 100% <br />131 <br />Lighting 0.01 <br />x 100% <br />0.01 <br />0 <br />x 125% <br />0 <br />Mech 32.49 <br />x 100% <br />32.49 <br />39 <br />125% of Largest <br />48 <br />Recept 0.90 <br />10 KVA @ 100%, rest @ 50% <br />0.90 <br />1 <br />x 100% <br />1 <br />Recorded Demand 308.00 <br />x 125% <br />385.00 <br />463 <br />x 100% <br />463 <br />* Recorded Demand calculated as 308.00kVA x 100% S.A.F. x 100% O.A.F. <br />449.99 <br />541 Amps <br />526.99 <br />634 <br />643 <br />58 <br />57 <br />123 <br />3 <br />14 <br />34 <br />289 <br />2727 Oakes Ave. <br />sufte t <br />Ever4 WA 98201 <br />REVISIONS <br />v <br />k38180 <br />®� 4' �r <br />�'8IONAL 7/13/2021 <br />4100 194th Street SW Suite 400 <br />Lynnwood Washington 98036-4613 <br />(206)667-0555 <br />CD <br />7-13-21 <br />r..,, <br />if, <br />l� 1 <br />