Laserfiche WebLink
To Main Distribution <br />Power Panel <br />(Size Per Code) <br />Locate Chilled Water Supply & <br />Return Line Valves on Rear <br />Concrete Wall at -30" A.F.F. <br />Provide Access Door. <br />To Transtector <br />Power Conditioner <br />(Size Per Code) <br />(2) 2" Chilled Water Conduit <br />Sleeves w/12" radius bends <br />Install against the <br />BaseFrame before grout. <br />TrueBeam Conduit Plan <br />Scale: 1 /8" = 1'-0" <br />AB -SLAB CONDUIT <br />IN -SLAB CONDUIT --- <br />TO MAIN POWER <br />DISTRIBUTION <br />SINGLE VOLTAGE INPUT, <br />SINGLE VOLTAGE OUTPUT <br />POWER CONDITIONER <br />GENERAL TrueBeam POWER SPEC: <br />• 480V, 80A, at 60Hz <br />• 3PH + N & G. 48KVA <br />FOR COMPLETE POWER SPEC SEE <br />SECTION 4.2 IN THE TrueBeam DDR. <br />Provide adequate clearance for typical conduit radius of <br />six times the diameter. Conduit bends shall not exceed <br />270 degrees per cable run. Route all room penetrations <br />as perpendicular to the isocenter as possible to avoid <br />radiation scatter. Verify all room penetrations with the <br />Physicist of Record. <br />Conduit run lengths for Varian supplied cables shall not <br />exceed 75'-0" <br />FROM <br />TO <br />Qty <br />Size <br />in. [mm] <br />BaseFrame Pull Box <br />Control Equipment Pull Box <br />4 <br />4" [100] <br />A <br />Modulator Pull Box <br />3 <br />4" [100] <br />B <br />Relay Junction Box <br />2 <br />2" [50] <br />C <br />Modulator Pull Box <br />Main Circuit Breaker Panel <br />2 <br />2" [50] <br />D <br />Relay Junction Box <br />Warning Lights <br />1 <br />0.5" [13] <br />E <br />Door Interlocks (24vDc & uovx) <br />1 <br />0.5" (13] <br />F <br />Accessory Pull Box <br />Control Equipment <br />Pull Box <br />1 <br />3" [75] <br />G <br />2 <br />2" [50] <br />H <br />Optical Imaging Camera <br />1 <br />3" (75] <br />1 <br />In -Room Monitors (qty 1 set) <br />1 <br />2" [50] <br />J <br />Live View Camera & <br />Microphone (primary) <br />2 <br />1.25" (32] <br />K <br />Microphone (secondary, ceiling) <br />1 <br />1.25" (32] <br />L <br />CCTV Camera (qty 4) <br />1 <br />1" [25] <br />M <br />Speaker (qty 2) <br />1 <br />1" [25] <br />N <br />Service Keyboard & <br />Optional VVS System <br />1 <br />1" [25] <br />0 <br />Main Circuit <br />Breaker Panel <br />Control Equipment Pull Box <br />1 <br />2" [50] <br />P <br />IEC 60309, 30A, 250V <br />Receptacle <br />1 <br />Per Code <br />Q <br />Network (Data) <br />1 <br />1" [25] <br />R <br />Experimental <br />(Physics) Access <br />Treatment Room <br />1 <br />3" [75] <br />S <br />Control Area <br />Treatment Room <br />(future use, optional) <br />2 <br />4" [100] <br />T <br />04 <br />Typical TrueBeam Conduit Riser Diagram <br />Scale: 1/8" = 1'-0" <br />W I EQUIPMENT <br />01 Stand <br />02 Gantry <br />031 Modulator Cabinet <br />06 Isocenter <br />08 Control Cabinet, 2-1 Configuration <br />(5'-1 7/16" H x 2'-2 7/16"W x 2'-9 7/16"D) <br />09 Optical Imaging Camera <br />10 In —Room Monitors <br />11 CCTV Camera <br />121 Live View Camera w/Mic <br />131 Microphone (ceiling) <br />14 Wireless Keyboard/Mouse <br />15 Speaker <br />16 Optional VVS or PAVS System <br />Warning Lights <br />18 (0ty:2) Beam —On & X—Ray—On, verify additional <br />requirements with the regional regulatory agency <br />Control Console Pull Box <br />19 (30"x 12" x 6•) <br />20 Modulator Pull Box <br />(24" x 18" x 10") <br />21 BaseFrame Pull Box <br />(24" x 12" x 10") <br />22 Accessory Pull Box <br />(24"W x 18"L x 12"D — minimum) <br />24 Relay Junction Box <br />(20"H x 16"W x 6"D) <br />25 Main Circuit Breaker Panel <br />(37 1 /4"H x 25 1 /2"W x 9 1 /4"D, 179 lbs.) <br />30 Transtector Power Conditioner <br />(66"H x 29"W x 36"D, 1,142 lbs.) <br />I <br />■ <br />