SPECIFICATIONS <br />011000-SUMMARY <br />A. WORK SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CALIFORNIA GREEN <br />BUILDING STANDARDS CODE (CALGREEN), SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT <br />(SCAQMD) AIR POLLUTION CONTROL AGENCY, SACRAMENTO METROPOLITAN AIR QUALITY <br />MANAGEMENT DISTRICT (SMAQMD) AIR POLLUTION CONTROL AGENCY AND OTHER <br />AUTHORITIES HAVING JURISDICTION. <br />B. ALL DIRECTIVES AND/OR CHANGES THAT AFFECT THIS PROJECT SHALL COME FROM THE OWNER <br />TO THE ARCHITECT, AND THEN TO THE GENERAL CONTRACTOR, THE GENERAL CONTRACTOR <br />SHALL ISSUE A CHANGE ORDER PROPOSAL ON FORM ACCEPTABLE TO OWNER TO THE <br />ARCHITEcr AND OWNER FOR SIGNATURE. FIELD DIRECTIVES AND/OR CHANGES SHALL NOT BE <br />INCLUDED IN THE WORK UNTIL THE ARCHITECT AND OWNER HAVE SIGNED THE CHANGE <br />ORDER, NO WORK IS TO BE DONE AT THE REQUEST OF THE WAREHOUSE MANAGER, <br />C. THE GENERAL CONTRACTOR IS THE PROJECT COORDINAT OR, AND SHALL PROVIDE <br />COORDINATION AND CONTROL FOR ALL WORK OF THE ENTIRE CONTRACT INCLUDED IN THESE <br />CONTRACT DOCUMENTS AND SPECIFIED HEREIN. <br />014000 - QUALITY REQUIREMENTS <br />A� COSTS FOR INSPECTIONS AND TESTS REQUIRED BY BUILDING OFFICIALS AND REQUEsTED BY <br />OWNER ON EARTHWORK, STEEL WORK, AND CONCRETE PLACED ON THE SITE WILL BE PAID BY <br />THE OWNER. <br />B� COSTS FOR RE -INSPECTIONS AND RE -TESTS, AND ADDED COSTS FOR INSPECTIONS AND TESTS <br />DUE TO POOR WORKMANSHIP, NON-COM PLIANCE WITH THE CONTRACT DOCUMENTS, LATE <br />SCHEDULING, CANCELLATIONS, OR ILL-TIMED NOTICES ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR. <br />1. WHEN INITIAL TESTS DISPLAY NON-COMPLIANCE WITH THE CONTRACT DOCUMENTS, THE <br />SAME TESTING AGENCY THAT PERFORMED THE INITIAL TESTS SHALL DO THE WORK OF RE - <br />INSPECTION OR RE-TEsTING THE EARLIER TESTS, <br />2. PAYMENT FOR RE -INSPECTION OR RE -TEST COSTS WILL BE MADETO THE TESTING AGENCY <br />BY THE OWNER, BUT THE CONTRACT SUM IN THE AGREEMENT BETWEEN OWNER AND <br />CONTRACTOR WILL BE ADJUSTED BY CHANGE ORDER TO RECOVER THE COST. <br />C. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF MATERIALS AND <br />EQUIPMENT. <br />A. TEMPORARY UTILITIES, USE OF OWNER'S EXISTING ELECTRICAL, SEWAGE, AND WATER WILL BE <br />PERMITTED WITHOUT METERING. CONTRACTOR SHALL PROVIDE SAFE TEMPORARY <br />CONNECTIONS AND MAINTAIN CONDITIONS ACCEPTABLE TO THE OWNER, <br />B. SANITARY FACILITIES: USE OF OWNER'S EXISTING TOILET FACILITIES WILL BE PERMITTED, AS <br />LONG AS FACILITIES ARE CLEANED AND MAINTAINED IN A CONDITION ACCEPTABLE TO OWNER, <br />AT SUBSTANTIAL COMPLETION, RESTORE THESE FACILITIES TO CONDITION EXISTING BEFORE <br />INITIAL USE. <br />C. TEMPORARY PARTITIONS: PROVIDE DUSTPROOF PARTITIONS TO LIMIT DUST AND DIRT <br />MIGRATION AND TO SEPARATE AREAS OCCUPIED BY OWNER FROM 'FUMES AND NOISE. <br />1. INSULATE PARTITIONS TO CONTROL NOISE TRANSMISSION TO OCCUPIED AREAS. <br />2, SEAL JOINTS AND PERIMETER. EQUIP PARTITIONS WITH GASKETED DUSTPROOF DOORS <br />AND SECURITY LOCKS WHERE OPENINGS ARE REQUIRED. <br />3. PROTECT AIR -HANDLING EQUIPMENT. <br />4. PROVIDE WALK -OFF MATS AT EACH ENTRANCE THROUGH TEMPORARY PARTITION, <br />5. PLASTIC SHEETING USED SHALL BE FLAME RESISTANT. <br />D. BARRICADES, WARNING SIGNS, AND LIGHTS: <br />1. PROVIDE FENCES AND SAFEGUARDS NECESSARY FOR THE CONVENIENCE AND PROTECTION <br />OF THE PUBLIC, AS REQUIRED BY CODE AND LAW ENFORCEMENT REGULATIONS. <br />017329 - CUTTING AND PATCHING <br />A. CUTTING: CUT EXISTING CONSTRUCTION BY SAWING, DRILLING, BREAKING, CHIPPING, <br />G RINDING, AND SIMILAR OPERATIONS, INCLUDING EXCAVATION, USING METHODS LEAST <br />LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJOINING CONSTRUCTION. <br />1. IN GENERAL, USE HAND OR SMALL POWER TOOLS DESIGNED FOR SAWING AND GRINDING, <br />NOT HAMMERING AND CHOPPING. CUT HOLES AND SL07FS AS SMALL AS POSSIBLE, NEATLY <br />TO SIZE REQUIRED, AND WITH MINIMUM DISTURBANCE OF ADJACENT SURFACES. <br />TEMPORARILY COVER OPENINGS WHEN NOT IN USE. <br />2. EXISTING FINISHED SURFACES: CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO <br />CONCEALED SURFACES. <br />3. CONCRETE, MASONRY: CUT USING A CUTTING MACHINE, SUCH AS AN ABRASIVE SAW OR A <br />DIANIOND CORE DRILL, <br />4. MECHANICAL AND ELECTRICAL SERVICES: CUT OFF PIPE OR CONDUIT IN WALLS OR <br />PARTITIONS TO BE REMOVED. CAP, VALVE, OR PLUG AND SEAL REMAINING PORTION OF <br />PIPE OR CONDUIT TO PREVENT ENTRANCE OF MOISTURE OR OTHER FOREIGN MATTER <br />AFTER CUTTING. <br />PATCHING: PATCH CONSTRUCTION BY FILLING, REPAIRING, REFINISHING, CLOSING UP, AND <br />SIMILAR OPERATIONS FOLLOWING PERFORMANCE OF OTHER WORK. PATCH WITH DURABLE <br />SEAMS THAT ARE AS INVISIBLE AS POSSIBLE. PROVIDE MATERIALS AND COMPLY WITH <br />INSTALLATION REQUIREMENTS SPECIFIED IN OTHER SECTIONS OF THESE SPECIFICATIONS. <br />1. EXPOSED FINISHES: RESTORr' EXPOSED FINISHES OF PATCHED AREAS AND EXTEND FINISH <br />RESTORATION INTO RETAINED ADJOINING CONSTRUCTION IN A MANNER THAT WILL <br />ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. <br />2. FLOORS AND WALLS: WHERE WALLS OR PARTITIONS THAT ARE REMOVED EXTEND ONE <br />FINISHED AREA INTO ANOTHER, PATCH AND REPAIR FLOOR AND WALL SURFACES IN THE <br />NEW SPACE, PROVIDE AN EVEN SURFACE OF UNIFORM FINISH, COLOR, TEXTURE, AND <br />APPEARANCE. REMOVE EXISTING FLOOR AND WALL COVERINGS AND REPLACE WITH NEW <br />MATERIALS, IF NECESSARY, TO ACHIEVE UNIFORM COLOR AND APPEARANCE. <br />1 WHERE PATCHING OCCURS IN A PAINTED SURFACE, APPLY PRIMER AND INTERMEDIATE <br />PAINT COATS OVER THE PATCH AND APPLY FINAL PAINT COAT OVER ENTIRE UNBROKEN <br />SURFACE CONTAINING THE PATCH. PROVIDE ADDITIONAL COATS UNTIL PATCH BLENDS <br />WITH ADJACENT SURFACES. <br />4. CEILINGS: PATCH, REPAIR, OR RE -HANG EXISTING CEILINGS AS NECESSARY'ro PROVIDE AN <br />EVEN PLANE SURFACE OF UNIFORM APPEARANCE. <br />33300 - CONCRETE FLOOR AND CURBS <br />A. PROPORTIONING AND DESIGN OF CONCRETE MIXES: <br />1. PREPARE DESIGN MIX FOR 3500 PSI STRENGTH CONCRETE BY EITHER LABORATORY TRIAL <br />BATCH OR FIELD EXPERIENCE METHODS AS SPECIFIED IN ACI 301. IF TRIAL BATCH METHOD <br />USED, USE AN INDEPENDENT TESTING FACILITY FOR PREPARING AND REPORTING <br />PROPOSED MIX DESIGNS. THE TEST ING FACILITY SHALL NOT BE THE SAME AS USED FOR <br />FIELD QUALITY CONTROL TESTING. <br />2. USE NO FLY ASH IN CONCRETE. <br />1 USE NO AIR ENTRAINMENT. <br />B. CONCRETE SLAB REPAIR PRODUCT: TWO-PART HYBRID URETHANE THAT COMBINES WITH SAND <br />TO FORM A TOUGH INSTANT POUYMER CONCRETE. <br />1. ACCEPTABLE PRODUCT: "10-MINUTE CONCRETE MENDER"' (VOC 5.5 G/L) MANUFACTURED <br />BY ROADWARE INC., 2100 WENTWORTH AVE., SOUTH SAINT PAUL, MN 55075; PHONE- <br />(800) 5227623 OR (651) 457-6122; FAX: (651) 457-1420;. WWW,rONCP,.ETEMENDER.COM. <br />051200 -STRUCTURAL STEEL RAMING <br />A� STEEL MATERIALS: STRUCTURAL QUALITY, OF SIZES AND TYPES NOTED ON STRUCTURAL <br />DRAWINGS, <br />1. CARBON STEEL SHAPES, PLATES AND BARS A-STM A 36/A 36M. <br />2. STEEL TUBE SECTIONS: ASTM A 500/A 500M, GRADE B. <br />B. WELDED, RIVETED OR BOLTED CONNECTIONS IN ACCORDANCE WITH AISC CODE, <br />1. WELDING IN ACCORDANCE WITH CURRENT "CODE FOR ARC AND GAS WELDING IN <br />BUILDING CONSTRUCTION" OF AMERICAN WELDING SOCIETY. <br />2. HOLES PUNCHED OR DRILLED; CUTTING TORCH NOT PERMITTED. <br />054000 - COLD FORMED METAL FRAMING <br />A. WALL FRAMING: MANUFACTURER'S STANDARD STEEL STUDS, OF WEB DEPTHS INDICATED, <br />WITH STIFFENED FLANGES, COMPLYING WITH ASTM C 955, AND AS FOLLOWS, <br />1� MINIMUM UNCOATED -STEEL THICKNESS, 18 GAUGE 0.0428 INCHa <br />2. FLANGE WIDTH: 1-5/8 INCHES (41 MM). <br />3. TRACK: MANUFACTURER'S STANDARD U-SHAPED STEEL TRACK, UNPUNCHED, WITH <br />STRAIGHT FLANGES, COMPLYING WITH ASTNI C 955, MANUFAcTURER�S STANDARD FLANGE <br />WIDTH., AND MINIMUM UNCOATED -STEEL THICKNESS MATCHING STEEL STUDS. <br />S. JOISTFRAMING: MANUFACTURER�S STANDARD C-SHAPED STEEL JOISTS., OF WEB DEPTHS <br />INDICATED, UNPUNCHED, WITH STIFFENED FLANGES, COMPLYING WITH ASTM C 955. UNLESS <br />OTHERWISE INDICATED ON THE DRAWINGS, USE THE FOLLOWING: <br />1. MINIMUM UNCOATED-STEELTHICKNESS. 16 GAUGE 0.0538 INCH� <br />2. FLANGE WIDTH: 1-5/8 INCHES (41 MM), MINIMUM. <br />3. TRACK: MANUFACTURER'S STANDARD U-SHAPED STEEL JOIST TRACK, OF WEB DEPTHS <br />INDICATED, UNPUNCHED, WITH UNSTIFFENED FLANGES, COMPLYING WITH ASTM C 955, <br />AND AS FOLLOWS: <br />a. MINIMUM UNCOATED -STEEL THICKNESS: MATCHING STEELJOISTS. <br />b. FLANGE WIDTH: 1-5/8 INCHES (41 MM), MINIMUM. <br />C. ACCESSORIES: <br />1. FABRICATE STEEL -FRAMING ACCESSORIES OF THE SAME MATERIAL AND FINISH USED FOR <br />FRAMING MEMBERS, WITH MINIMUM YIELD STRENGTH OF 33,000 PSI, OF <br />MANUFACTURER'S STANDARD THICKNESS AND CONFIGURATION, UNLESS OTHERWISE <br />INDICATED. <br />2, EXPANSION ANCHORS: FABRICATED FROM CORROSION -RESISTANT MATERIALS, WITH <br />CAPABILITY TO SUSTAIN, WITHOUT FAILURE, A LOAD EQUAL TO 5 TIMES DESIGN LOAD, AS <br />DETERMINED BYTESTING PER ASTM E 488 CONDUCTED BY A QUALIFIED INDEPENDENT <br />TESTING AGENCY. <br />068316 - FIBERGLASS REINFORCED PANELS <br />A. ACCEPTABLE PRODUCTS: PROVIDE FRPP HAVING UL (ULC) 'CLASSIFIED CLASS A INTERIOR FINISH <br />MATERIAL PER ASTM E 84, 3/32 (�090) INCH THICK, WITH SIZE OF 4 x 8 FEET OR 4 x 10 FEET, <br />1. CRANE COMPOSITES; FIRE-X GLASBORD WITH SURFASEAL, PRODUCT CODE 6226, CLASS A, <br />WITH EMBOSSED TEXTURE. <br />a. COLOR: ff 85 WHITE, <br />2. NUDO FIBERLITE FRP PANELS, CLASS A, WITH PEBBLE TEXTURED SURFACE. <br />a. COLOR: 050 WHITE. <br />3. MARLITE STANDARD FRP PANELS, CLASS A, WITH PEBBLE TEXTURED SURFACE. <br />a. COLOR: P199 BRITE WHITE. <br />D. ACCESSORIES: <br />ADHESIVE: PROVIDE PANEL ADHESIVE AS RECOMMENDED BY PANEL MANUFACTURER. <br />2. TRIM AND SEAM TREATMENT: EXTRUDED PVC CORNER MOLDINGS, DIVISION BARS, END <br />TRIM AND CAP. <br />a. COLOR: WHITE TO MATCH PANEL COLOR. <br />A. INTERIOR JOINTS BETWEEN PLUMBING FIXTURES AND ADJOINING WALLS, FLOORS, AND <br />COUNTERS; AND BETWEEN POLYMER FLOOR BASE AND MIP / FRPP: USE SINGLE -COMPONENT <br />MILDEW-RESISTANTACID-CURING SILICONE SEALANT. USE WHITE COLOR AT PORCELAIN <br />FIXTURES, GREY COLOR AT STAINLESS STEEL, OR OTHER APPROPRIATE COLOR TO MATCH <br />ADJACENT SURFACE FINISHES. <br />1. ACCEPTABLE PRODUCTS: <br />a. 786 MILDEW RESISTANT (VOC 33 G/L) BY DOW CORNING CORP., 2200 W. SALZBURG <br />ROAD, MIDLAND, MI 48686-0994, PH� (800) 248-2481 OR (989) 496-4400, PAX: (989) <br />496-4393, HTTP://WWW,DOWCORNING,COM. <br />b� SANITARY SCS1700 (VOC 20 G - /L) BY GE CONSTRUCTION SEALANT, 9930 KINCEY <br />AVENUE, HUNTERSVILLE, NC 28078, PH: (800) 255-8886 OR (877) 943-7325, FXX: (304) <br />746-1654, HTTP://WWW.GESEALANTS,COM, <br />2. TYPE AND GRADE: S (SINGLE COMPONENT) AND NS (NONSAG). <br />3. CLASS: 25, <br />USE RELATED TO EXPOSURE: NT. <br />092116 -GYPSUM BOARD ASSEMBLIES <br />A. STEEL FRAMING, GENERAL: COMPLY WITH ASTM C 754 AND ASTM C 840 FOR CONDITIONS <br />INDICATED, <br />1. STEEL SHEET COMPONENTS: METAL COMPLYING WITH ASTM C 645 REQUIREMENTS. <br />2. PROTECTIVE COATING: ASTM A 653 /A 653M, G60, HOT -DIP GALVANIZED ZINC COATING. <br />B. INTERIOR GYPSUM WALLBOARD: COMPLYING WITH ASTM C 36/C 36M OR ASTM C 1396/C <br />1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD INDICATED AND WHICHEVER IS N10RE <br />STRINGENT. <br />1. USE 5/8-INCH THICK, TYPE X, WITH LONG EDGES TAPERED, TYPICAL. <br />C. BEHIND WALL TILE, STAINLESS STEEL WALL LINING, FIBERGLASS REINFORCED PLASTIC PANELS <br />(FRPP) IN FOOD PREPARATION AREAS: PROVIDE 5/8 INCH THICK, GYPSUM FIBER INTERIOR <br />PANELS WITHOUT FACE PAPER. <br />1. ACCEPTABLE PRODUCT. "FIBEROCK BRAND AQUA TOUGH INTERIOR PANELS" <br />MANUFACTURED BY USG. <br />096700 - POLYMER FLOORING <br />A. THE OWNER HASA NATIONAL ACCOUNT WITH HTI POLYMER, INC. TO SUPPLY ALL PRODUCTS <br />SPECIFIED IN THIS SECTION. <br />HTI POL.YMER, INC. <br />18732 142ND AVE NE <br />WOODINVILLE, WA 98072 <br />CONTACT: CHRIS CAMPTON <br />PHONE: (425) 487-8911 / (866) 930-8911 <br />FAX: (425) 487-8915 <br />EMAIL: CHRIS@HTIPO�-YMER.COM <br />B. A FOUR -WEEK NOTICE IS REQUIRED PRIORTO INSTALLATION OF POLYMER FLOORS. <br />C. PF-A: GENERAL POLYMERS FASTOP 12 TC URETHANE CEMENT SYSTEM: <br />1. PENETRATING, MOISTURE TOLERANT TWO -COMPONENT EPDXY WATER EMULSION <br />PRIMER, APPLIED AT 250-300 SQ� FT. / GAL. <br />a. APPROVED PRODUCT: GENERAL POLYMERS 3477. <br />2. THREE -COMPONENT URETHANE CEMENT SLURRY, APPLIED AT 40 SQ. FT. PER MIXED UNIT <br />(NOMINAL 1/4-INCH THICK FOR THIS MORTAR LAYER COMPONENT OF THE SYSTEM). <br />a. APPROVED PRODUCT. GENERAL POLYMERS FASTOP 12 S. <br />3. THREE -COMPONENT URETHANE CEMENTTOPCOAT SEALER, APPLIED WITH A SPRAYER <br />APPARATUS. <br />a. APPROVED PRODUCT: GENERAL POLYMERS FASTOP TC. <br />b. COLOR: MATCH EXISTING, <br />D. HONOR ALL CONTROL JOINTS IN THE CONCRETE SLAB BY CUTTING THROUGH THE URETHANE <br />CEMENT FLOOR AND INSTALLING A JOINT FILLER. <br />a. APPROVED PRODUCT: METZGER MCGUIRE SPAL-PRO, RS 88 POLYUREA JOINT FILLER. <br />b. COLOR� GRAY. <br />097000 - STAINLESS STEEL PANELS <br />A. STAINLESS -STEEL SHEET: USE 20 GAUGE (0.036 INCH) (0.91 MM) ASTM A 666, TYPE 304 <br />STAINLESS STEEL SHEETS. <br />1� GENERAL, COMPLY WITH SSINA'S "FINISHES FOR STAINLESS STEEL" FOR <br />RECOMMENDATIONS FOR APPLYING AND DESIGNATING FINISHES. <br />2. REMOVE TOOL AND DIE MARKS AND STRETCH LINES OR BLEND INTO FINISH. GRIND AND <br />POLISH SURFACES TO PRODUCE UNIFORM, DIRECTIONALLY TEXTURED, POLISHED FINISH <br />INDICATED, FREE OF CROSS SCRATCHES, RUN GRAIN WITH LONG DIMENSION OF EACH <br />PIECE, <br />3. STAINLESS -STEEL FINISHES: <br />a. EXPOSED SURFACESA ASTM A 480 / A 480M, NO. 4 FINISH. <br />b. CONCEALED SURFACES: ASTM A 480 / A 480M, NO. 2B FINISH (BRIGHT, COLD -ROLLED, <br />UNPOLISHED FINISH). <br />4. FABRICATE THE FOLLOWING WALL PANEL JOINT CONNECTORS AND COVERS USING <br />MATCHING MATERIAL: <br />a. PANEL CORNER, CENTER, AND END SLIP JOINTS, CLEATS, AND MOLDINGS <br />b. TOP, BOTTOM, AND END PANEL EDGE COVERS AND FLASHINGS. <br />c. FORMED AND MATCHING END TRIM. <br />099100 - PAINTING <br />A. UN -GALVANIZED AND GALVANIZED STEEL: <br />1. SHERWIN-WILLIAMS: <br />a. FIRSTCOAT: PRO INDUSTRIAL PRO-CRYL UNIVERSAL WATER BASED PRIMER B66-310 <br />SERIES (2.0-4.0 MILS DRY) (VOC < 100 G/L) <br />b. SECOND AND THIRD COATS: PROMAR 200 ZERO VOC INTERIOR LATEX B31-2600 <br />SEMIGLOSS B31WO2651 (1.6 MILS DRY PER COAT). <br />2, PPG: <br />a. FIRST COAT! 90-912 PITTTECH PLUS DTM ACRYLIC PRIMER (2.0-4.0 MILS DRY). <br />b. SECOND AND THIRD COATS: 6-4510 SERIES SPEEDHIDE INTERIOR ZERO VOC LATEX <br />SEMIGLOSS (13 MILS DRY PER COAT). <br />3. COLOR TO MATCH SHERWIN-WILLIAMS SW 7030 "'ANEW GRAY". <br />B. GYPSUM WALLBOARD: <br />1. SHERWIN-WILLIAMS. <br />a. FIRSTCOAT: PROMAR 400 ZERO VOC INTERIOR LATEX PRIMER B28WO4600 (1A MILS <br />DRY PER COAT). <br />b. SECOND AND THIRD COATS: PROMAR 200 ZERO VOC INTERIOR LATEX 020-2600 EG- <br />SHEL B20WI2651 (L7 MILS DRY PER COAT). <br />2. PPG: <br />a. FIRST COAT: 6-2 SPEEDHIDE INTERIOR LATEX PRIMER (1,2 MILS DRY) (VOC < 46 G/Q� <br />b. SECOND AND THIRD COATS: 6-4310 SERIES SPEEDHIDE INTERIOR ZERO VOC LATEX <br />EGGSHELL (1.5 MILS DRY PER COAT) (VOC 0 G/Q. <br />3. COLOR OF GENERAL WALLBOARD APPLICATIONS: COLOR TO MATCH SHERWIN-WILLIAMS <br />SW 7003 "TOQUE WHITE", EXCEPT WHERE NOTED ON DRAWINGS. <br />www.ctagroup.com <br />8 0 0. 7 5 7 . 9 5 2 2 <br />0 <br />0 <br />0 <br />C) <br />(D <br />C) <br />N <br />C) <br />9T_ <br />T <br />Oc 2018 1 ALL RIGHTS RESERVED <br />12.14.2018 <br />DRAWN BY I CHUDY <br />CHECKED BY I BRENNAN <br />REVISIONS <br />079200 - JOINT SEALANTS <br />OU9.17 11:03 PIM I L\COSTCOM 14 Evereft, WAUIVICAMArchld 14_G2.dwg <br />