SPECIFICATIONS
<br />011000-SUMMARY
<br />A. WORK SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CALIFORNIA GREEN
<br />BUILDING STANDARDS CODE (CALGREEN), SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT
<br />(SCAQMD) AIR POLLUTION CONTROL AGENCY, SACRAMENTO METROPOLITAN AIR QUALITY
<br />MANAGEMENT DISTRICT (SMAQMD) AIR POLLUTION CONTROL AGENCY AND OTHER
<br />AUTHORITIES HAVING JURISDICTION.
<br />B. ALL DIRECTIVES AND/OR CHANGES THAT AFFECT THIS PROJECT SHALL COME FROM THE OWNER
<br />TO THE ARCHITECT, AND THEN TO THE GENERAL CONTRACTOR, THE GENERAL CONTRACTOR
<br />SHALL ISSUE A CHANGE ORDER PROPOSAL ON FORM ACCEPTABLE TO OWNER TO THE
<br />ARCHITEcr AND OWNER FOR SIGNATURE. FIELD DIRECTIVES AND/OR CHANGES SHALL NOT BE
<br />INCLUDED IN THE WORK UNTIL THE ARCHITECT AND OWNER HAVE SIGNED THE CHANGE
<br />ORDER, NO WORK IS TO BE DONE AT THE REQUEST OF THE WAREHOUSE MANAGER,
<br />C. THE GENERAL CONTRACTOR IS THE PROJECT COORDINAT OR, AND SHALL PROVIDE
<br />COORDINATION AND CONTROL FOR ALL WORK OF THE ENTIRE CONTRACT INCLUDED IN THESE
<br />CONTRACT DOCUMENTS AND SPECIFIED HEREIN.
<br />014000 - QUALITY REQUIREMENTS
<br />A� COSTS FOR INSPECTIONS AND TESTS REQUIRED BY BUILDING OFFICIALS AND REQUEsTED BY
<br />OWNER ON EARTHWORK, STEEL WORK, AND CONCRETE PLACED ON THE SITE WILL BE PAID BY
<br />THE OWNER.
<br />B� COSTS FOR RE -INSPECTIONS AND RE -TESTS, AND ADDED COSTS FOR INSPECTIONS AND TESTS
<br />DUE TO POOR WORKMANSHIP, NON-COM PLIANCE WITH THE CONTRACT DOCUMENTS, LATE
<br />SCHEDULING, CANCELLATIONS, OR ILL-TIMED NOTICES ARE THE RESPONSIBILITY OF THE
<br />CONTRACTOR.
<br />1. WHEN INITIAL TESTS DISPLAY NON-COMPLIANCE WITH THE CONTRACT DOCUMENTS, THE
<br />SAME TESTING AGENCY THAT PERFORMED THE INITIAL TESTS SHALL DO THE WORK OF RE -
<br />INSPECTION OR RE-TEsTING THE EARLIER TESTS,
<br />2. PAYMENT FOR RE -INSPECTION OR RE -TEST COSTS WILL BE MADETO THE TESTING AGENCY
<br />BY THE OWNER, BUT THE CONTRACT SUM IN THE AGREEMENT BETWEEN OWNER AND
<br />CONTRACTOR WILL BE ADJUSTED BY CHANGE ORDER TO RECOVER THE COST.
<br />C. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF MATERIALS AND
<br />EQUIPMENT.
<br />A. TEMPORARY UTILITIES, USE OF OWNER'S EXISTING ELECTRICAL, SEWAGE, AND WATER WILL BE
<br />PERMITTED WITHOUT METERING. CONTRACTOR SHALL PROVIDE SAFE TEMPORARY
<br />CONNECTIONS AND MAINTAIN CONDITIONS ACCEPTABLE TO THE OWNER,
<br />B. SANITARY FACILITIES: USE OF OWNER'S EXISTING TOILET FACILITIES WILL BE PERMITTED, AS
<br />LONG AS FACILITIES ARE CLEANED AND MAINTAINED IN A CONDITION ACCEPTABLE TO OWNER,
<br />AT SUBSTANTIAL COMPLETION, RESTORE THESE FACILITIES TO CONDITION EXISTING BEFORE
<br />INITIAL USE.
<br />C. TEMPORARY PARTITIONS: PROVIDE DUSTPROOF PARTITIONS TO LIMIT DUST AND DIRT
<br />MIGRATION AND TO SEPARATE AREAS OCCUPIED BY OWNER FROM 'FUMES AND NOISE.
<br />1. INSULATE PARTITIONS TO CONTROL NOISE TRANSMISSION TO OCCUPIED AREAS.
<br />2, SEAL JOINTS AND PERIMETER. EQUIP PARTITIONS WITH GASKETED DUSTPROOF DOORS
<br />AND SECURITY LOCKS WHERE OPENINGS ARE REQUIRED.
<br />3. PROTECT AIR -HANDLING EQUIPMENT.
<br />4. PROVIDE WALK -OFF MATS AT EACH ENTRANCE THROUGH TEMPORARY PARTITION,
<br />5. PLASTIC SHEETING USED SHALL BE FLAME RESISTANT.
<br />D. BARRICADES, WARNING SIGNS, AND LIGHTS:
<br />1. PROVIDE FENCES AND SAFEGUARDS NECESSARY FOR THE CONVENIENCE AND PROTECTION
<br />OF THE PUBLIC, AS REQUIRED BY CODE AND LAW ENFORCEMENT REGULATIONS.
<br />017329 - CUTTING AND PATCHING
<br />A. CUTTING: CUT EXISTING CONSTRUCTION BY SAWING, DRILLING, BREAKING, CHIPPING,
<br />G RINDING, AND SIMILAR OPERATIONS, INCLUDING EXCAVATION, USING METHODS LEAST
<br />LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJOINING CONSTRUCTION.
<br />1. IN GENERAL, USE HAND OR SMALL POWER TOOLS DESIGNED FOR SAWING AND GRINDING,
<br />NOT HAMMERING AND CHOPPING. CUT HOLES AND SL07FS AS SMALL AS POSSIBLE, NEATLY
<br />TO SIZE REQUIRED, AND WITH MINIMUM DISTURBANCE OF ADJACENT SURFACES.
<br />TEMPORARILY COVER OPENINGS WHEN NOT IN USE.
<br />2. EXISTING FINISHED SURFACES: CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO
<br />CONCEALED SURFACES.
<br />3. CONCRETE, MASONRY: CUT USING A CUTTING MACHINE, SUCH AS AN ABRASIVE SAW OR A
<br />DIANIOND CORE DRILL,
<br />4. MECHANICAL AND ELECTRICAL SERVICES: CUT OFF PIPE OR CONDUIT IN WALLS OR
<br />PARTITIONS TO BE REMOVED. CAP, VALVE, OR PLUG AND SEAL REMAINING PORTION OF
<br />PIPE OR CONDUIT TO PREVENT ENTRANCE OF MOISTURE OR OTHER FOREIGN MATTER
<br />AFTER CUTTING.
<br />PATCHING: PATCH CONSTRUCTION BY FILLING, REPAIRING, REFINISHING, CLOSING UP, AND
<br />SIMILAR OPERATIONS FOLLOWING PERFORMANCE OF OTHER WORK. PATCH WITH DURABLE
<br />SEAMS THAT ARE AS INVISIBLE AS POSSIBLE. PROVIDE MATERIALS AND COMPLY WITH
<br />INSTALLATION REQUIREMENTS SPECIFIED IN OTHER SECTIONS OF THESE SPECIFICATIONS.
<br />1. EXPOSED FINISHES: RESTORr' EXPOSED FINISHES OF PATCHED AREAS AND EXTEND FINISH
<br />RESTORATION INTO RETAINED ADJOINING CONSTRUCTION IN A MANNER THAT WILL
<br />ELIMINATE EVIDENCE OF PATCHING AND REFINISHING.
<br />2. FLOORS AND WALLS: WHERE WALLS OR PARTITIONS THAT ARE REMOVED EXTEND ONE
<br />FINISHED AREA INTO ANOTHER, PATCH AND REPAIR FLOOR AND WALL SURFACES IN THE
<br />NEW SPACE, PROVIDE AN EVEN SURFACE OF UNIFORM FINISH, COLOR, TEXTURE, AND
<br />APPEARANCE. REMOVE EXISTING FLOOR AND WALL COVERINGS AND REPLACE WITH NEW
<br />MATERIALS, IF NECESSARY, TO ACHIEVE UNIFORM COLOR AND APPEARANCE.
<br />1 WHERE PATCHING OCCURS IN A PAINTED SURFACE, APPLY PRIMER AND INTERMEDIATE
<br />PAINT COATS OVER THE PATCH AND APPLY FINAL PAINT COAT OVER ENTIRE UNBROKEN
<br />SURFACE CONTAINING THE PATCH. PROVIDE ADDITIONAL COATS UNTIL PATCH BLENDS
<br />WITH ADJACENT SURFACES.
<br />4. CEILINGS: PATCH, REPAIR, OR RE -HANG EXISTING CEILINGS AS NECESSARY'ro PROVIDE AN
<br />EVEN PLANE SURFACE OF UNIFORM APPEARANCE.
<br />33300 - CONCRETE FLOOR AND CURBS
<br />A. PROPORTIONING AND DESIGN OF CONCRETE MIXES:
<br />1. PREPARE DESIGN MIX FOR 3500 PSI STRENGTH CONCRETE BY EITHER LABORATORY TRIAL
<br />BATCH OR FIELD EXPERIENCE METHODS AS SPECIFIED IN ACI 301. IF TRIAL BATCH METHOD
<br />USED, USE AN INDEPENDENT TESTING FACILITY FOR PREPARING AND REPORTING
<br />PROPOSED MIX DESIGNS. THE TEST ING FACILITY SHALL NOT BE THE SAME AS USED FOR
<br />FIELD QUALITY CONTROL TESTING.
<br />2. USE NO FLY ASH IN CONCRETE.
<br />1 USE NO AIR ENTRAINMENT.
<br />B. CONCRETE SLAB REPAIR PRODUCT: TWO-PART HYBRID URETHANE THAT COMBINES WITH SAND
<br />TO FORM A TOUGH INSTANT POUYMER CONCRETE.
<br />1. ACCEPTABLE PRODUCT: "10-MINUTE CONCRETE MENDER"' (VOC 5.5 G/L) MANUFACTURED
<br />BY ROADWARE INC., 2100 WENTWORTH AVE., SOUTH SAINT PAUL, MN 55075; PHONE-
<br />(800) 5227623 OR (651) 457-6122; FAX: (651) 457-1420;. WWW,rONCP,.ETEMENDER.COM.
<br />051200 -STRUCTURAL STEEL RAMING
<br />A� STEEL MATERIALS: STRUCTURAL QUALITY, OF SIZES AND TYPES NOTED ON STRUCTURAL
<br />DRAWINGS,
<br />1. CARBON STEEL SHAPES, PLATES AND BARS A-STM A 36/A 36M.
<br />2. STEEL TUBE SECTIONS: ASTM A 500/A 500M, GRADE B.
<br />B. WELDED, RIVETED OR BOLTED CONNECTIONS IN ACCORDANCE WITH AISC CODE,
<br />1. WELDING IN ACCORDANCE WITH CURRENT "CODE FOR ARC AND GAS WELDING IN
<br />BUILDING CONSTRUCTION" OF AMERICAN WELDING SOCIETY.
<br />2. HOLES PUNCHED OR DRILLED; CUTTING TORCH NOT PERMITTED.
<br />054000 - COLD FORMED METAL FRAMING
<br />A. WALL FRAMING: MANUFACTURER'S STANDARD STEEL STUDS, OF WEB DEPTHS INDICATED,
<br />WITH STIFFENED FLANGES, COMPLYING WITH ASTM C 955, AND AS FOLLOWS,
<br />1� MINIMUM UNCOATED -STEEL THICKNESS, 18 GAUGE 0.0428 INCHa
<br />2. FLANGE WIDTH: 1-5/8 INCHES (41 MM).
<br />3. TRACK: MANUFACTURER'S STANDARD U-SHAPED STEEL TRACK, UNPUNCHED, WITH
<br />STRAIGHT FLANGES, COMPLYING WITH ASTNI C 955, MANUFAcTURER�S STANDARD FLANGE
<br />WIDTH., AND MINIMUM UNCOATED -STEEL THICKNESS MATCHING STEEL STUDS.
<br />S. JOISTFRAMING: MANUFACTURER�S STANDARD C-SHAPED STEEL JOISTS., OF WEB DEPTHS
<br />INDICATED, UNPUNCHED, WITH STIFFENED FLANGES, COMPLYING WITH ASTM C 955. UNLESS
<br />OTHERWISE INDICATED ON THE DRAWINGS, USE THE FOLLOWING:
<br />1. MINIMUM UNCOATED-STEELTHICKNESS. 16 GAUGE 0.0538 INCH�
<br />2. FLANGE WIDTH: 1-5/8 INCHES (41 MM), MINIMUM.
<br />3. TRACK: MANUFACTURER'S STANDARD U-SHAPED STEEL JOIST TRACK, OF WEB DEPTHS
<br />INDICATED, UNPUNCHED, WITH UNSTIFFENED FLANGES, COMPLYING WITH ASTM C 955,
<br />AND AS FOLLOWS:
<br />a. MINIMUM UNCOATED -STEEL THICKNESS: MATCHING STEELJOISTS.
<br />b. FLANGE WIDTH: 1-5/8 INCHES (41 MM), MINIMUM.
<br />C. ACCESSORIES:
<br />1. FABRICATE STEEL -FRAMING ACCESSORIES OF THE SAME MATERIAL AND FINISH USED FOR
<br />FRAMING MEMBERS, WITH MINIMUM YIELD STRENGTH OF 33,000 PSI, OF
<br />MANUFACTURER'S STANDARD THICKNESS AND CONFIGURATION, UNLESS OTHERWISE
<br />INDICATED.
<br />2, EXPANSION ANCHORS: FABRICATED FROM CORROSION -RESISTANT MATERIALS, WITH
<br />CAPABILITY TO SUSTAIN, WITHOUT FAILURE, A LOAD EQUAL TO 5 TIMES DESIGN LOAD, AS
<br />DETERMINED BYTESTING PER ASTM E 488 CONDUCTED BY A QUALIFIED INDEPENDENT
<br />TESTING AGENCY.
<br />068316 - FIBERGLASS REINFORCED PANELS
<br />A. ACCEPTABLE PRODUCTS: PROVIDE FRPP HAVING UL (ULC) 'CLASSIFIED CLASS A INTERIOR FINISH
<br />MATERIAL PER ASTM E 84, 3/32 (�090) INCH THICK, WITH SIZE OF 4 x 8 FEET OR 4 x 10 FEET,
<br />1. CRANE COMPOSITES; FIRE-X GLASBORD WITH SURFASEAL, PRODUCT CODE 6226, CLASS A,
<br />WITH EMBOSSED TEXTURE.
<br />a. COLOR: ff 85 WHITE,
<br />2. NUDO FIBERLITE FRP PANELS, CLASS A, WITH PEBBLE TEXTURED SURFACE.
<br />a. COLOR: 050 WHITE.
<br />3. MARLITE STANDARD FRP PANELS, CLASS A, WITH PEBBLE TEXTURED SURFACE.
<br />a. COLOR: P199 BRITE WHITE.
<br />D. ACCESSORIES:
<br />ADHESIVE: PROVIDE PANEL ADHESIVE AS RECOMMENDED BY PANEL MANUFACTURER.
<br />2. TRIM AND SEAM TREATMENT: EXTRUDED PVC CORNER MOLDINGS, DIVISION BARS, END
<br />TRIM AND CAP.
<br />a. COLOR: WHITE TO MATCH PANEL COLOR.
<br />A. INTERIOR JOINTS BETWEEN PLUMBING FIXTURES AND ADJOINING WALLS, FLOORS, AND
<br />COUNTERS; AND BETWEEN POLYMER FLOOR BASE AND MIP / FRPP: USE SINGLE -COMPONENT
<br />MILDEW-RESISTANTACID-CURING SILICONE SEALANT. USE WHITE COLOR AT PORCELAIN
<br />FIXTURES, GREY COLOR AT STAINLESS STEEL, OR OTHER APPROPRIATE COLOR TO MATCH
<br />ADJACENT SURFACE FINISHES.
<br />1. ACCEPTABLE PRODUCTS:
<br />a. 786 MILDEW RESISTANT (VOC 33 G/L) BY DOW CORNING CORP., 2200 W. SALZBURG
<br />ROAD, MIDLAND, MI 48686-0994, PH� (800) 248-2481 OR (989) 496-4400, PAX: (989)
<br />496-4393, HTTP://WWW,DOWCORNING,COM.
<br />b� SANITARY SCS1700 (VOC 20 G - /L) BY GE CONSTRUCTION SEALANT, 9930 KINCEY
<br />AVENUE, HUNTERSVILLE, NC 28078, PH: (800) 255-8886 OR (877) 943-7325, FXX: (304)
<br />746-1654, HTTP://WWW.GESEALANTS,COM,
<br />2. TYPE AND GRADE: S (SINGLE COMPONENT) AND NS (NONSAG).
<br />3. CLASS: 25,
<br />USE RELATED TO EXPOSURE: NT.
<br />092116 -GYPSUM BOARD ASSEMBLIES
<br />A. STEEL FRAMING, GENERAL: COMPLY WITH ASTM C 754 AND ASTM C 840 FOR CONDITIONS
<br />INDICATED,
<br />1. STEEL SHEET COMPONENTS: METAL COMPLYING WITH ASTM C 645 REQUIREMENTS.
<br />2. PROTECTIVE COATING: ASTM A 653 /A 653M, G60, HOT -DIP GALVANIZED ZINC COATING.
<br />B. INTERIOR GYPSUM WALLBOARD: COMPLYING WITH ASTM C 36/C 36M OR ASTM C 1396/C
<br />1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD INDICATED AND WHICHEVER IS N10RE
<br />STRINGENT.
<br />1. USE 5/8-INCH THICK, TYPE X, WITH LONG EDGES TAPERED, TYPICAL.
<br />C. BEHIND WALL TILE, STAINLESS STEEL WALL LINING, FIBERGLASS REINFORCED PLASTIC PANELS
<br />(FRPP) IN FOOD PREPARATION AREAS: PROVIDE 5/8 INCH THICK, GYPSUM FIBER INTERIOR
<br />PANELS WITHOUT FACE PAPER.
<br />1. ACCEPTABLE PRODUCT. "FIBEROCK BRAND AQUA TOUGH INTERIOR PANELS"
<br />MANUFACTURED BY USG.
<br />096700 - POLYMER FLOORING
<br />A. THE OWNER HASA NATIONAL ACCOUNT WITH HTI POLYMER, INC. TO SUPPLY ALL PRODUCTS
<br />SPECIFIED IN THIS SECTION.
<br />HTI POL.YMER, INC.
<br />18732 142ND AVE NE
<br />WOODINVILLE, WA 98072
<br />CONTACT: CHRIS CAMPTON
<br />PHONE: (425) 487-8911 / (866) 930-8911
<br />FAX: (425) 487-8915
<br />EMAIL: CHRIS@HTIPO�-YMER.COM
<br />B. A FOUR -WEEK NOTICE IS REQUIRED PRIORTO INSTALLATION OF POLYMER FLOORS.
<br />C. PF-A: GENERAL POLYMERS FASTOP 12 TC URETHANE CEMENT SYSTEM:
<br />1. PENETRATING, MOISTURE TOLERANT TWO -COMPONENT EPDXY WATER EMULSION
<br />PRIMER, APPLIED AT 250-300 SQ� FT. / GAL.
<br />a. APPROVED PRODUCT: GENERAL POLYMERS 3477.
<br />2. THREE -COMPONENT URETHANE CEMENT SLURRY, APPLIED AT 40 SQ. FT. PER MIXED UNIT
<br />(NOMINAL 1/4-INCH THICK FOR THIS MORTAR LAYER COMPONENT OF THE SYSTEM).
<br />a. APPROVED PRODUCT. GENERAL POLYMERS FASTOP 12 S.
<br />3. THREE -COMPONENT URETHANE CEMENTTOPCOAT SEALER, APPLIED WITH A SPRAYER
<br />APPARATUS.
<br />a. APPROVED PRODUCT: GENERAL POLYMERS FASTOP TC.
<br />b. COLOR: MATCH EXISTING,
<br />D. HONOR ALL CONTROL JOINTS IN THE CONCRETE SLAB BY CUTTING THROUGH THE URETHANE
<br />CEMENT FLOOR AND INSTALLING A JOINT FILLER.
<br />a. APPROVED PRODUCT: METZGER MCGUIRE SPAL-PRO, RS 88 POLYUREA JOINT FILLER.
<br />b. COLOR� GRAY.
<br />097000 - STAINLESS STEEL PANELS
<br />A. STAINLESS -STEEL SHEET: USE 20 GAUGE (0.036 INCH) (0.91 MM) ASTM A 666, TYPE 304
<br />STAINLESS STEEL SHEETS.
<br />1� GENERAL, COMPLY WITH SSINA'S "FINISHES FOR STAINLESS STEEL" FOR
<br />RECOMMENDATIONS FOR APPLYING AND DESIGNATING FINISHES.
<br />2. REMOVE TOOL AND DIE MARKS AND STRETCH LINES OR BLEND INTO FINISH. GRIND AND
<br />POLISH SURFACES TO PRODUCE UNIFORM, DIRECTIONALLY TEXTURED, POLISHED FINISH
<br />INDICATED, FREE OF CROSS SCRATCHES, RUN GRAIN WITH LONG DIMENSION OF EACH
<br />PIECE,
<br />3. STAINLESS -STEEL FINISHES:
<br />a. EXPOSED SURFACESA ASTM A 480 / A 480M, NO. 4 FINISH.
<br />b. CONCEALED SURFACES: ASTM A 480 / A 480M, NO. 2B FINISH (BRIGHT, COLD -ROLLED,
<br />UNPOLISHED FINISH).
<br />4. FABRICATE THE FOLLOWING WALL PANEL JOINT CONNECTORS AND COVERS USING
<br />MATCHING MATERIAL:
<br />a. PANEL CORNER, CENTER, AND END SLIP JOINTS, CLEATS, AND MOLDINGS
<br />b. TOP, BOTTOM, AND END PANEL EDGE COVERS AND FLASHINGS.
<br />c. FORMED AND MATCHING END TRIM.
<br />099100 - PAINTING
<br />A. UN -GALVANIZED AND GALVANIZED STEEL:
<br />1. SHERWIN-WILLIAMS:
<br />a. FIRSTCOAT: PRO INDUSTRIAL PRO-CRYL UNIVERSAL WATER BASED PRIMER B66-310
<br />SERIES (2.0-4.0 MILS DRY) (VOC < 100 G/L)
<br />b. SECOND AND THIRD COATS: PROMAR 200 ZERO VOC INTERIOR LATEX B31-2600
<br />SEMIGLOSS B31WO2651 (1.6 MILS DRY PER COAT).
<br />2, PPG:
<br />a. FIRST COAT! 90-912 PITTTECH PLUS DTM ACRYLIC PRIMER (2.0-4.0 MILS DRY).
<br />b. SECOND AND THIRD COATS: 6-4510 SERIES SPEEDHIDE INTERIOR ZERO VOC LATEX
<br />SEMIGLOSS (13 MILS DRY PER COAT).
<br />3. COLOR TO MATCH SHERWIN-WILLIAMS SW 7030 "'ANEW GRAY".
<br />B. GYPSUM WALLBOARD:
<br />1. SHERWIN-WILLIAMS.
<br />a. FIRSTCOAT: PROMAR 400 ZERO VOC INTERIOR LATEX PRIMER B28WO4600 (1A MILS
<br />DRY PER COAT).
<br />b. SECOND AND THIRD COATS: PROMAR 200 ZERO VOC INTERIOR LATEX 020-2600 EG-
<br />SHEL B20WI2651 (L7 MILS DRY PER COAT).
<br />2. PPG:
<br />a. FIRST COAT: 6-2 SPEEDHIDE INTERIOR LATEX PRIMER (1,2 MILS DRY) (VOC < 46 G/Q�
<br />b. SECOND AND THIRD COATS: 6-4310 SERIES SPEEDHIDE INTERIOR ZERO VOC LATEX
<br />EGGSHELL (1.5 MILS DRY PER COAT) (VOC 0 G/Q.
<br />3. COLOR OF GENERAL WALLBOARD APPLICATIONS: COLOR TO MATCH SHERWIN-WILLIAMS
<br />SW 7003 "TOQUE WHITE", EXCEPT WHERE NOTED ON DRAWINGS.
<br />www.ctagroup.com
<br />8 0 0. 7 5 7 . 9 5 2 2
<br />0
<br />0
<br />0
<br />C)
<br />(D
<br />C)
<br />N
<br />C)
<br />9T_
<br />T
<br />Oc 2018 1 ALL RIGHTS RESERVED
<br />12.14.2018
<br />DRAWN BY I CHUDY
<br />CHECKED BY I BRENNAN
<br />REVISIONS
<br />079200 - JOINT SEALANTS
<br />OU9.17 11:03 PIM I L\COSTCOM 14 Evereft, WAUIVICAMArchld 14_G2.dwg
<br />
|