a <br />IN- <br />m <br />A <br />GENERAL STRUCTURAL NOTES <br />GENERAL <br />ALL TYPICAL DETAILS AND NOTES SHOWN ON THESE DRAWINGS ARE PART OF THE CONSTRUCTION CONTRACT <br />CARBON FADER REINFORCED POLYMER (CFRP) AND EPDXY �NJEC70N <br />AND SHALL BE PROVIDED BY THE CONTRACTOR. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE <br />PLANS, BUT SHALL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. <br />REFERENCE STANDARDS: FRP SHALL CONFORM TO ALL REQUIREMENTS OF THE FOLLOWING DOCUMENTS: <br />ACI 440.2-17 "GUIDE FOR THE DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS <br />C <br />FOR STRENGTHENING CONCRETE STRUCTURES" <br />BUILDING CODE: ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE <br />ACI 503R-93 "USE OF EPDXY COMPOUNDS WITH CONCRETE" <br />DRAWINGS AND THE INTERNATIONAL BUILDING CODE (IBC) 2015 EDITION AND THE INTERNATIONAL EXISTING <br />BUILDING CODE (IEBC) 2015 EDITION, AS AMENDED BY THE CITY OF EVERETT. STRUCTURAL REPAIRS SHALL BE IN <br />ACI 546R-14 "CONCRETE REPAIR GUIDE" <br />COMPLIANCE WITH IEBC SECTION 606. <br />ICRI 310.2-2013 "SELECTING AND SPECIFYING CONCRETE SURFACE PREPARATION FOR SEALERS, COATINGS, <br />THE REPAIR WORK ON THE EXISTING BUILDING INCLUDES RESTORATION AND REPLACEMENT OF DAMAGED <br />POLYMER OVERLAYS, AND CONCRETE REPAIRS" <br />CONCRETE ELEMENTS WITH MATERIALS OF SIMILAR CAPACITIES TO RESTORE TO THEIR ORIGINAL CONDITION. <br />ICRI #320.2R-2009 "GUIDE FOR SELECTING AND SPECIFYING MATERIALS FOR REPAIR OF CONCRETE SURFACES" <br />STANDARDS: REFERENCE TO ASTM AND OTHER STANDARDS SHALL MEAN THE LATEST EDITION IN EFFECT ON <br />FRP SYSTEMS SHALL CONFORM TO ANY ADDITIONAL STANDARDS RECOMMENDED BY THE MANUFACTURER OR THE SUPPLIER. <br />THE BID DATE, UNLESS NOTED IN THESE DOCUMENTS OR DESIGNATED BY THE GOVERNING CODE. <br />MATERIALS AND TESTING: <br />LOADS AND CRITERIA <br />EPDXY -RESIN BONDING SYSTEMS ASTM C881 / C881M <br />GRAVITY- IN ADDITION TO THE SELF WEIGHT, THE FOLLOWING WERE USED FOR DESIGN: <br />FRP TEST METHODS ASTM D3039 <br />UNIFORM CONCENTRATED SUPERIMPOSED <br />LIVE LOAD LIVE LOAD DEAD LOAD <br />PULL -OFF TEST ASTM D4541 <br />(PSF) (K) (PSF) <br />STAIRS AND LANDINGS 100 3,000 5 <br />FRP MATERIALS: THE CFRP COMPOSITE LAMINATE SYSTEM SHALL BE ONE OF THE FOLLOWING PRODUCTS: <br />FLOORS 40 - 15 <br />* FYFECO TYFO SCH CARBON FIBER OR SEH GLASS FIBER <br />CORRIDORS 100 - 15 <br />* MILLIKEN INFRASTRUCTURE RENEW WRAP CARBON FIBER OR VELAGLASS GLASS FIBER <br />EITHER GFRP OR CFRP MAY BE USED AT CONTRACTOR'S OPTION AT FRP LOCATIONS UNLESS GFRP IS SPECIFICALLY <br />SUBMITTALS <br />CALLED OUT IN THE PLANS OR ELEVATIONS, GFRP MUST BE USED AT LOCATIONS WHERE IT IS SPECIFICALLY CALLED <br />OUT. CFRP MAY NOT BE USED AT CFRP LOCATIONS, CONTRACTOR SHALL VERIFY THAT THE FRP SYSTEM SELECTED <br />SHOP DRAWINGS AND SUBMITTALS SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION OR <br />HAS SUFFICIENT CAPACITY TO MEET DESIGN REQUIREMENTS AND THAT THICKNESS OF THE SYSTEM WILL BE <br />CONSTRUCTION OF THESE ITEMS: <br />COMPATIBLE WITH FINISHES NOTED IN ARCHITECTURAL DRAWINGS. <br />EPDXY INJECTION <br />EPDXY RESIN SHALL BE INTENDED BY THE MANUFACTURER FOR USE AS PART OF A FRP SYSTEM AND SHALL BE <br />FIBER REINFORCED POLYMER SYSTEM <br />PROVIDED AS PART OF THE FRP SYSTEM. AN APPROVED ICC-ES REPORT OR ICC-ES LEGACY REPORT SHALL BE <br />CONTRACTOR SHALL REVIEW AND STAMP SUBMITTALS PRIOR TO SUBMISSION. DIMENSIONS AND QUANTITIES ARE <br />PROVIDED TO SUBSTANTIATE THE PERFORMANCE OF THE FRP SYSTEM. PREPARATION AND INSTALLATION OF THE <br />CONTRACTOR'S RESPONSIBILITY AND WILL NOT BE REVIEWED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL <br />SYSTEM SHALL BE AS RECOMMENDED BY THE MANUFACTURER AND ANY ADDITIONAL REQUIREMENTS INCLUDED IN <br />MATERIALS PLACED PRIOR TO RECEIPT OF REVIEWED SUBMITTALS. CONTRACTOR SHALL ALLOW14 CALENDAR <br />THE ICC-ES REPORT OR ICC-ES LEGACY REPORT. <br />DAYS TIME FOR REVIEW. <br />RAW SAMPLES AND MSDS OF ALL MATERIALS USED IN THE APPLICATION OF THE FRP COMPOSITE LAMINATE SYSTEM <br />DEFERRED SUBMITTALS: DRAWINGS AND CALCULATIONS FOR BIDDER -DESIGNED COMPONENTS, SEALED BY THE <br />SHALL BE SUBMITTED TO THE EVERGREEN STATE COLLEGE DEPARTMENT OF HEALTH AND SAFETY FOR REVIEW AND <br />WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN, SHALL BE SUBMITTED <br />APPROVAL PRIOR TO CONSTRUCTION. SAMPLES SHALL BE SUBMIT FOR ANY EPDXY, BONDING AGENTS SEALER, <br />FOR REVIEW OF GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. DEFERRED SUBMITTALS INCLUDE: <br />ARCHITECTURAL FINISH, OR ANY OTHER CHEMICAL USED DURING THE COURSE OF THE PROJECT. SEE SPECIFICATIONS <br />FOR FRP FINISH REQUIREMENTS WHERE DRAWINGS INDICATE ARCHITECTURAL FINISHES ARE REQUIRED. <br />FIBER REINFORCED POLYMER SYSTEM TEMPORARY SHORING <br />DESIGN STRENGTH: THE FRP SYSTEM SHALL PROVIDE A TOTAL STRENGTH AND CONFINEMENT AS CALLED OUT IN THE <br />SUBMITTALS OF BIDDER -DESIGNED ITEMS SHALL INCLUDE LOCATIONS, MAGNITUDES, AND DIRECTIONS OF ALL FORCES <br />DRAWINGS. WHERE REQUIRED NOMINAL STRENGTHS ARE CALLED OUT IN THE DRAWINGS, THEY REFLECT THE REQUIRED <br />CFRP STRENGTH ONLY. WHERE A MINIMUM NUMBER OF FRP LAYERS IS ALSO INDICATED, BOTH CRITERIA SHALL BE <br />TRANSFERRED TO THE STRUCTURE. CALCULATIONS SUBMITTED FOR BIDDER -DESIGNED ITEMS ARE FOR INFORMATION <br />APPLIED TO THE CFRP DESIGN. CONTRIBUTIONS FROM EXISTING CONCRETE OR REBAR ARE NOT INCLUDED. NOMINAL <br />ONLY AND WILL NOT BE APPROVED OR RETURNED. <br />VALUES ASSUME THAT A SHEAR STRENGTH REDUCTION FACTOR, 0, OF 0.75 (PER ACI 318-14) AND AN ADDITIONAL <br />SPECIAL INSPECTION PER IBC SECTIONS 1704 SHALL BE PERFORMED BY AN AGENCY ACCEPTED BY THE BUILDING <br />REDUCTION FACTOR,Vf, , OF 0.95 AND 0.85 FOR COMPLETELY -WRAPPED AND PARTIALLY -WRAPPED MEMBERS, <br />OFFICIAL AND AS OUTLINED IN THE STRUCTURAL INSPECTION SCHEDULE. <br />RESPECTIVELY (PER ACI 440.2R-17, TABLE 11.3), WILL BE APPLIED. IF THE PROPOSED CFRP SYSTEM REQUIRES A <br />DIFFERENT 0 O 1�f FACTOR, NOMINAL VALUES SHALL BE SCALED UP AS REQUIRED TO COMPENSATE FOR THE <br />STRUCTURAL OBSERVATION SHALL BE PERFORMED PER IBC 1704.6. <br />ALTERNATE REDUCTION VALUES. LOWER NOMINAL VALUES SHALL NOT BE USED. PLEASE NOTE THAT ICC-ES AC125 <br />REQUIRES LOWER VALUES FOR WALLS WITH 1-SIDED FRP APPLICATIONS AS COMPARED TO 2-SIDED APPLICATIONS. SEE <br />ICC-ES AC125 SECTION 7.3.2.6.1.CALCULATIONS PREPARED AND STAMPED BY AN WASHINGTON STATE LICENSED <br />EXISTING CONDITIONS: CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR <br />PROFESSIONAL ENGINEER QUALIFIED TO DESIGN FRP SYSTEMS SHALL BE PROVIDED TO SUBSTANTIATE THESE VALUES. <br />TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED <br />DESIGNS SHALL BE BASED ON DESIGN VALUES ESTABLISHED IN THE ICC-ES REPORT OR ICC-ES LEGACY REPORT. <br />AS GUIDELINES ONLY AND MUST BE VERIFIED. EXISTING CONDITIONS SHOWN ON DRAWINGS ARE BASED EITHER ON SITE <br />OBSERVATIONS, ORIGINAL DRAWINGS, OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF EXISTING CONDITIONS <br />EPDXY CONCRETE: EPDXY CONCRETE SHALL BE USED TO FILL VOIDS AND SHALL BE APPLIED ACCORDING TO THE <br />DO NOT CLOSELY MATCH CONDITIONS SHOWN ON DRAWINGS, OR IF EXISTING MATERIALS ARE OF QUESTIONABLE OR <br />MANUFACTURER'S RECOMMENDATIONS. PRIME DRY CAVITY SURFACES WITH EPDXY RESIN USING A STIFF BRISTLE <br />SUBSTANDARD QUALITY, NOTIFY ENGINEER PRIOR TO COMMENCING ANY WORK. <br />BRUSH. MAKE COATING APPROXIMATELY 20 MILS THICK. PLACE EPDXY CONCRETE WHILE PRIMER IS STILL TACKY AND I <br />CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING FOR APPROVAL PRIOR TO FABRICATION AND <br />LAYERS NOT EXCEEDING ONE INCH THICK. USE VIBRATORY FLOATS, PLATES, OR HAND TAMPERS TO CONSOLIDATE THE <br />CONCRETE. LEVEL EACH LAYER AND SCREED THE FINAL SURFACE TO MATCH THE ADJOINING SURFACES. REMOVE <br />CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS OR SUBMITTALS ONLY WILL NOT SATISFY THIS REQUIREMENT. <br />EXCESS EPDXY CONCRETE ON ADJACENT SURFACES BEFORE THE CONCRETE HARDENS. DO NOT FEATHER EPDXY <br />CONCRETE OUT ONTO ADJACENT SURFACES. EPDXY CONCRETE COMPRESSIVE STRENGTH SHALL BE 6,000 PSI MINIMUM. <br />CONTRACTOR RESPONSIBILITIES: DRAWINGS REPRESENT DESIGN OF STRUCTURE IN COMPLETED FORM. CONTRACTOR <br />FRP CURING: CURE EPDXY CONCRETE MATERIALS AND FRP MATERIALS IN ACCORDANCE WITH MANUFACTURER'S ,. <br />SHALL BE RESPONSIBLE FOR METHODS, SEQUENCES, AND SAFETY PRECAUTIONS REQUIRED TO PERFORM WORK. <br />RECOMMENDATION. <br />CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING OF ALL STRUCTURAL MEMBERS, EXISTING CONSTRUCTION, <br />FRP MATERIAL TESTING: A SAMPLE BATCH SHALL CONSIST OF TWO 12"x12" SAMPLES OF CURED FRP COMPOSITE <br />AND SOIL EXCAVATION AS REQUIRED. SHORING AND BRACING SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE <br />MATERIAL. THE LOT NUMBER OF THE FABRIC AND RESIN AND THE LOCATION OF THE INSTALLATION SHALL BE RECORDED. <br />BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS, AND MATERIALS HAVE ACHIEVED DESIGN STRENGTH. <br />MAKE A MINIMUM OF TWO SAMPLE BATCHES PER DAY. THE TEST LABORATORY SHALL PREPARE THE SAMPLE IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND AS REQUIRED PER ASTM D3039. FURNISH ONE <br />CONTRACTOR SHALL OBTAIN AND REVIEW THE EXISTING RECORD DRAWINGS AND TESTING RECORDS ASSOCIATED WITH <br />12"x12" SAMPLE OF CURED COMPOSITE TO THE ENGINEER OF RECORD. <br />THIS PROJECT PRIOR TO DESIGN, FABRICATION, OR INSTALLATION OF THE CFRP SYSTEM. STRUCTURAL DESIGN SHOWN <br />IN THESE DRAWINGS IS BASED ON GEOMETRY AND DIMENSIONS SHOWN IN RECORD DRAWINGS PROVIDED BY THE CITY <br />THE 12"xl2" SAMPLE PANELS SHALL HAVE FIVE COUPONS, 3/4"x9", REMOVED AND TESTED FOR MATERIAL PROPERTIES IN <br />OF EVERETT. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND GEOMETRY PRIOR TO FABRICATION WHERE <br />THE LONGITUDINAL (PRIMARY FIBER) DIRECTION PER ASTM D3039. TEST LABORATORY SHALL CONFIRM WITH THE <br />VARIATIONS IN THE EXISTING CONDITIONS MAY AFFECT FABRICATION OR INSTALLATION. <br />MANUFACTURER THAT THEY ARE TESTING IN THE SPECIFIED DIRECTION. TEST PROCEDURES SHALL CONFORM TO ASTM <br />D3039 AND THE MANUFACTURER'S PUBLISHED TESTING METHODS. TESTING RESULTS SHALL BE MADE AVAILABLE WITHIN <br />DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS, REFERENCE STANDARDS, OR <br />THREE WEEKS OF SAMPLE SUBMISSION. TESTING SHALL PROVIDE AVERAGE VALUES OF ULTIMATE TENSILE STRENGTH, <br />GOVERNING CODE, THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. CONTRACTOR SHALL NOTIFY THE ENGINEER <br />TENSILE MODULUS, AND PERCENT ELONGATION AT ULTIMATE TENSILE STRENGTH. 25 PERCENT OF SAMPLE BATCHES <br />OF DISCREPANCIES AND OBTAIN DIRECTION PRIOR TO PROCEEDING. NOTES ON INDIVIDUAL STRUCTURAL DRAWINGS <br />SHALL BE TESTED. IF ONE 12"x12" SPECIMEN FAILS (ON AVERAGE), THE REMAINING SPECIMEN FROM THE SAME BATCH <br />SHALL TAKE PRIORITY OVER STRUCTURAL NOTES ON SHEET S0.00. NOTED DIMENSIONS TAKE PRECEDENCE OVER <br />SHALL BE TESTED. IF THE SECOND SPECIMEN ALSO FAILS OR IF THE FIRST SPECIMEN FAILED BY 15 PERCENT OR MORE, <br />SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. <br />THE MANUFACTURER SHALL RECOMMEND AND THE CONTRACTOR SHALL EXECUTE REMEDIAL MEASURES TO ENSURE THE <br />INTEGRITY OF THE SYSTEM. ADDITIONALLY, 50 PERCENT OF REMAINING SAMPLES SHALL BE TESTED IF ANY ONE FAILING <br />RENOVATION <br />SPECIMEN IS FOUND. <br />DEMOLITION CUTTING AND DRILLING: DEMOLITION CUTTING AND DRILLING: CONTRACTOR SHALL VERIFY ALL EXISTING <br />CONDITIONS BEFORE COMMENCING ANY DEMOLITION, CUTTING OR DRILLING. SHORING SHALL BE INSTALLED TO SUPPORT <br />FRP PULL -OFF TESTING: A MINIMUM OF THREE PULL -OFF TEST PER 500 FT OF FRP INSTALLED OR ONE TEST MINIMUM <br />EXISTING CONSTRUCTION AS REQUIRED AND I A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING REINFORCING <br />SHALL BE PERFORMED, PERFORM TEST PER ASTM D4541 AND ACCORDING TO THE REQUIREMENTS OF THE <br />SHALL NOT BE DAMAGED. SAW -CUTTING, IF AND WHERE USED, SHALL NOT CUT EXISTING REINFORCING THAT IS TO BE <br />MANUFACTURER AND ANY ADDITIONAL REQUIREMENTS IN THE ICC-ES O ICC-ES LEGACY REPORT. TESTING EQUIPMENT <br />SAVED. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE, <br />AND LOCATIONS SHALL BE SELECTED TO AVOID DAMAGE TO THE POST -TENSIONING ANCHORAGE GROUT POCKETS THAT <br />CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS SHALL BE LIMITED TO 30 PSF. <br />OCCUR AT SOME COLUMN FACE LOCATIONS. CONDITIONS OF ACCEPTANCE SHALL BE: <br />SMALL ROUND OPENINGS SHALL BE ACCOMPLISHED BY HAMMER DRILLING. CORE DRILLING IS NOT PERMITTED. <br />A. THE FAILURE MODE IS COHESIVE FAILURE WITHIN THE CONCRETE. <br />REINFORCEMENT SHALL NOT BE DAMAGED. <br />B. THE TENSILE BOND STRENGTH SHALL BE IN EXCESS OF 200 PSI. <br />THE CONTRACTOR SHALL REPAIR THE TEST AREA IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION. <br />FRP INSPECTION: CHECK EACH AREA WHERE FRP HAS BEEN INSTALLED FOR CRACKS, SPALLS, POPOUTS, AND LOSS OF <br />BOND BETWEEN THE EPDXY CONCRETE OR FRP SYSTEM COMPONENTS AND THE SURROUNDING CONCRETE. CHECK EACH <br />EPDXY CONCRETE REPAIRED AREA FOR VOIDS BY TAPPING WITH A HAMMER OR STEEL ROD AND LISTENING FOR A DULL O <br />HOLLOW SOUNDS, CHECK EACH FRP REINFORCED AREA IN ACCORDANCE WITH THE MANUFACTURER°S RECOMMENDATIONS <br />AND ANY ADDITIONAL REQUIREMENTS IN THE ICC-ES OR ICC-ES LEGACY REPORT. IMMEDIATELY REPAIR DEFECTS. <br />� � 11 v�59 � ° 3 <br />TYPE OF MEMBER ASTM SPECIFICATION YIELD " Lv) m y� .,a .� <br />PLATES, ANGLES, a <br />R 15 <br />SI <br />CHANNELS, AND BARS A36 36 K(- z. C p <br />SPECIAL SHAPES'' ��I- �`. <br />(NOTED GRADE 50 ON DRAWINGS) A572 50 KSI P c ' ' 0 t ' e ''s"ce:`sn <br />MACHINE BOLTS (MB) A307 36 KSI <br />THREADED RODS JR) A193 GRADE B7 <br />CONNECTION BOLTS (HSB) A325 <br />STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE ZINC -COATED HOT -DIPPED GALVANIZED PER ASTM A123. ALL FIELD WELDS <br />EXPOSED TO WEATHER SHALL BE COATED WITH BRUSH APPLIED PAINT CONTAINING ZINC DUST COMPLYING WITH ASTM A780. ALL <br />BOLTS AND ANCHOR RODS EXPOSED TO WEATHER SHALL BE ZINC -COATED HOT -DIPPED GALVANIZED PER ASTM A153. <br />BOLTED CONNECTIONS SHALL BE TYPE "N`° WITH NUTS TIGHTENED TO AISC SNUG -TIGHT CRITERIA, UNLESS NOTED OTHERWISE. <br />CONNECTION PLATES SHALL HAVE AISC STANDARD ROUND HOLES UNLESS NOTED OTHERWISE. ALL OVERSIZED OR SLOTTED HOLES <br />SHALL HAVE WASHERS PROVIDED IN ACCORDANCE WITH AISC 360, UNLESS NOTED OTHERWISE. <br />WELDING: ALL WELDS SHALL COMPLY WITH AWS D1.1. WELDS SHALL BE MADE USING LOW HYDROGEN ELECTRODES WITH MINIMUM <br />TENSILE STRENGTH OF 70 KSI. ONLY AWS PREQUALIFIED WELDED JOINTS SHALL BE USED. SHOP DRAWINGS SHALL SHOW ALL <br />WELDING WITH AWS A2.4 STANDARD SYMBOLS, WELDS SHOWN ON DRAWINGS ARE MINIMUM SIZES. INCREASE WELD SIZE TO AWS <br />MINIMUM SIZES BASED ON PLATE THICKNESS. WELDS NOT SPECIFIED SHALL BE CONTINUOUS 3/16" FILLET WELDS. <br />ro <br />ENGINEER'S SEAL <br />EVERPARK GARAGE <br />2815 HOYT AVENUE <br />EVERETT, WA 98201 <br />FOR <br />CITY OF EVERETT <br />EVERPARK GARAGE <br />I ° A, RS <br />EVERETT, <br />{a x r Ida s' <br />tl T 1 <br />REVISIONS <br />NO. DATE <br />DESCRIPTION <br />3/12/19 <br />PERMIT RESUEMITTAL <br />4/2/19 <br />PERMIT RESUBMTTAL <br />PROJECT PRINCIPLE: <br />PROJECT MANAGER: <br />DESIGNED: <br />DRAWN: <br />CHECKED: <br />DATE: <br />PROJECT NUMBER: <br />PNC <br />PNC <br />SSS <br />EPP <br />PNC <br />03/12/2019 <br />262018_055 <br />w <br />SHEET TITLE <br />GENERAL STRUCTURAL A <br />NOTES <br />SHEET NUMBER <br />=1 <br />9 <br />