Laserfiche WebLink
CONTINUOUS <br />PERIODIC REFERENCED <br />SPECIAL INSPECTION OR TEST TYPE <br />SPECIAL <br />SPECIAL STANDARD <br />INSPECTION <br />INSPECTION <br />SDI QA/QC TABLE 1.1 <br />1. PRIOR TO DECK PLACEMENT VERIFY AND INSPECT THE FOLLOWING, <br />A. COMPLIANCE OF MATERIALS (DECK AND ALL ACCESSORIES) WITH <br />CONSTRUCTION DOCUMENTS INCLUDING PROFILES, MATERIAL <br />✓ <br />N(R <br />PROPERTIES, AND BASE METAL THICKNESS <br />B. DOCUMENT ACCEPTANCE OR REJECTION OF DECK AND DECK <br />✓ <br />N/R <br />ACCESSORIES <br />SDI QA/QC TABLE 1.2 <br />2. AFTER DECK PLACEMENT VERIFY AND INSPECT THE FOLLOWING: <br />A. COMPLIANCE OF DECK AND ALL ACCESSORIES INSTALLATION WITH <br />✓ <br />N/R <br />CONSTRUCTION DOCUMENTS <br />B. DECK MATERIALS ARE REPRESENTED BY THE MILL CERTIFICATIONS <br />✓ <br />NIR <br />THAT COMPLY WITH THE CONSTRUCTION DOCUMENTS <br />C. DOCUMENT ACCEPTANCE OR REJECTION OF INSTALLATION OF DECK <br />✓ <br />N/R <br />AND DECK ACCESSORIES <br />SDI QAlQC TABLE 1.3 <br />3. PRIOR TO WELDING, VERIFY AND INSPECT THE FOLLOWING: <br />A. WELDING PROCEDURE SPECIFICATION (WPS) <br />NIR <br />✓ <br />B. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES <br />N/R <br />✓ <br />C. MATERIAL IDENTIFICATION (TYPE/GRADE) <br />N/R <br />✓ <br />D, CHECK WELDING EQUIPMENT <br />NIR <br />SDI QA/QC TABLE 1.4 <br />4. DURING WELDING, VERIFY AND INSPECT THE FOLLOWING: <br />A. USE OF QUALIFIED WELDERS <br />N/R <br />✓ <br />B. CONTROL AND HANDLING OF WELDING CONSUMABLES <br />N/R <br />✓ <br />C. ENVIRONMENTAL CONDITIONS (WIND SPEED, MOISTURE, <br />N/R <br />✓ <br />TEMPERATURE <br />D. WPS FOLLOWED <br />NIR� <br />✓ <br />SDI QA/QC TABLE 1.6 <br />5. AFTER WELDING, VERIFY AND INSPECT THE FOLLOWING: <br />A. SIZE AND LOCATION OF WELDS INCLUDING SUPPORT, SIDE LAP AND <br />✓ <br />N/R <br />PERIMETER <br />B. WELDS MEET VISUAL ACCEPTANCE CRITERIA <br />✓ <br />N/R <br />C. REPAIR ACTIVITIES <br />✓ <br />N/R <br />D. DOCUMENT ACCEPTANCE OR REJECTION OF WELDS <br />�l — <br />✓ <br />N/R <br />SDI QA/QC TABLE 1.6 <br />6. PRIOR TO MECHANICAL FASTENING, VERIFY AND INSPECT THE FOLLOWING: <br />INSTALLATION INSTRUCTIONS AVAILABLE FOR <br />N/RECHANICAL <br />FASTENERS <br />JB,MANUFACTURER <br />PROPER TOOLS AVAILABLE FOR FASTENER INSTALLATION <br />N/R <br />✓ <br />C. PROPER STORAGE FOR MECHANICAL FASTENERS <br />N/R <br />✓ <br />SDI QA/QC TABLE 1.7 <br />7. DURING MECHANICAL FASTENING, VERIFY OR INSPECT THE FOLLOWING: <br />A. FASTENERS ARE POSITIONED AS REQUIRED <br />NIR <br />✓ <br />B. FASTENERS ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S <br />N/R <br />✓ <br />INSTRUCTIONS <br />SDI QA/QC TABLE 1.8 <br />8, AFTER MECHANICAL FASTENING, VERIFY OR INSPECT THE FOLLOWING: <br />A. CHECK SPACING, TYPE, AND INSTALLATION OF SUPPORT FASTENERS <br />✓ <br />N/R <br />B. CHECK SPACING, TYPE, AND INSTALLATION OF SIDELAP FASTENERS <br />✓ <br />N/R <br />C. CHECK SPACING, TYPE, AND INSTALLATION OF PERIMETER FASTENERS <br />✓ <br />N/R <br />D. VERIFY REPAIR ACTIVITIES <br />✓ <br />N/R <br />E. DOCUMENT ACCEPTANCE OR REJECTION OF MECHANICAL FASTENERS <br />✓ <br />N/R <br />1 E. REQUIRED SPECIAL. INSPECTIONS AND TESTS OF OPEN -WEB STEED JOISTS <br />AND JOIST GIRDERS <br />IBC TABLE 1705.2.3 <br />CONTINUOUS <br />PERIODIC <br />REFERENCED <br />SPECIAL INSPECTION OR TEST TYPE <br />SPECIAL <br />SPECIAL <br />STANDARD <br />INSPECTION <br />INSPECTION <br />1. INSTALLATION OF OPEN -WEB STEEL JOISTS AND JOIST GIRDERS <br />A. END CONNECTIONS - WELDING OR BOLTED <br />N/R <br />✓ <br />SJI SPECIFICATIONS <br />B. BRIDGING - HORIZONTAL OR DIAGONAL <br />N/R <br />✓ <br />SJI SPECIFICATIONS <br />15.1 STRUCTURAL STEEL CONSTRUCTION: <br />SPECIAL INSPECTION AND NONDESTRUCTIVE TESTING OF STRUCTURAL STEEL ELEMENTS SHALL BE IN ACCORDANCE WITH THE <br />QUALITY CONTROL AND QUALITY ASSURANCE REQUIREMENTS OF AISC 360, AS NOTED IN TABLES 15A, 15B, 15C, AND AWS D1.1, <br />INCLUDING: <br />15.1.1 INSPECTION OF ERECTED STEEL SYSTEM. <br />15.1,2 REVIEW OF MATERIAL TEST REPORTS AND CERTIFICATIONS FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS. <br />15.1.3 OBSERVATION OF WELDING OPERATIONS AND VISUAL INSPECTION OF IN -PROCESS AND COMPLETED WELDS SHALL BE AS <br />FOLLOWS: <br />A. VERIFY THAT WELD FILLER MATERIAL AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE CONFORM TO AWS <br />SPECIFICATION SPECIFIED. VERIFY WELDERS ARE CERTIFIED BY WABQ, THAT PROPER ELECTRODES IN OVEN DRY <br />CONDITIONS ARE USED, AND THAT PROPER METHODS AND PREPARATIONS ARE USED. <br />r, <br />B. PERIODIC SPECIAL INSPECTION OF WELDING SHALL BE PERFORMED FOR SINGLE PASS FILLET WELDS LESS THAN OR <br />EQUAL TO 5/16" AND FLOOR AND DECK WELDS. <br />C, CONTINUOUS SPECIAL INSPECTION OF WELDING SHALL BE PERFORMED ON COMPLETE AND PARTIAL PENETRATION <br />GROOVE WELDS AND FILLET WELDS GREATER THAN 5/16". <br />D. ALL WELDS SHALL BE CHECKED VISUALLY, <br />E. ALL SHOP AND FIELD WELDING SHALL BE SUBJECT TO INSPECTION BY A WABQ CERTIFIED WELDING INSPECTOR <br />EMPLOYED BY THE OWNER. THE INSPECTOR SHALL UTILIZE RADIOGRAPHIC, ULTRASONIC, OR MAGNETIC PARTICLE <br />TESTING AND ANY OTHER AID TO VISUAL INSPECTION THAT MAY BE DEEMED NECESSARY TO ASSURE THE ADEQUACY <br />OF WELDING. THE OWNER SHALL CARRY OUT TESTING AND INTERPRETATION AT ANY STAGE AFTER WELDING. <br />�� <br />4J <br />F, 10% OF ALL FILLET WELDS SHALL BE CHECKED BY MAGNETIC PARTICLE TESTING. <br />Ln <br />_6 <br />G. 100% OF ALL COMPLETE PENETRATION WELDS SHALL BE CHECKED BY ULTRASONIC TESTING. <br />H. ALL WELDS FOUND DEFECTIVE AND REPAIRED SHALL BE REINSPECTED BY THE SAME METHOD ORIGINALLY USED. <br />THE COST OF REPAIR AND REINSPECTION SHALL BE BORNE BY THE CONTRACTOR,00 <br />I. STANDARDS FOR ACCEPTANCE SHALL BE AS GIVEN IN AWS Dl A. <br />15.1 A OBSERVATION OF BOLTING OPERATIONS. <br />rD <br />15.1.5 CONTINUOUS SPECIAL INSPECTION SHALL BE PERFORMED FOR EACH JOINT OR MEMBER. PERIODIC SPECIAL INSPECTION <br />00 <br />00 <br />SHALL BE PERFORMED ON ITEMS ON A RANDOM BASIS. PERIODIC SPECIAL INSPECTION NEED NOT DELAY FABRICATION OR <br />ERECTION OPERATIONS. <br />15.1.6 COLD FORMED STEEL DECK: <br />SPECIAL INSPECTIONS AND QUALIFICATION FOR WELDING SPECIAL INSPECTORS SHALL BE IN ACCORDANCE WITH THE <br />a� <br />P <br />co <br />QUALITY ASSURANCE INSPECTION REQUIREMENTS OF SDI QA/QC, AS NOTED IN TABLE 15D. <br />0 <br />15.1.7 OPEN -WEB STEEL JOISTS AND JOIST GIRDERS: <br />ra <br />c J <br />SPECIAL INSPECTIONS OF OPEN -WEB STEEL JOISTS AND JOIST GIRDERS SHALL BE IN ACCORDANCE WITH TABLE 15E. <br />so <br />15.1.9 EPDXY ANCHORS: SPECIFIC REQUIREMENTS FOR INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE OR <br />�aa <br />co <br />MASONRY SHALL BE AS DESCRIBED IN THE RESEARCH REPORT ISSUED BY AN APPROVED SOURCE (ICC, IAPMO, ETC,). <br />> <br />0 <br />15.1.10 EXPANSION ANCHORS: SPECIFIC REQUIREMENTS FOR INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE OR <br />W o <br />v Q 4 z a <br />MASONRY SHALL BE AS DESCRIBED IN THE RESEARCH REPORT ISSUED BY AN APPROVED SOURCE (ICC, IAPMO, ETC.). <br />15.2 ADDITIONAL REQUIRED SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE PER IBC SECTION 1705.12. <br />U W <br />18.1 SPECIAL INSPECTIONS AND TESTING FOR SEISMIC RESISTANCE: <br />18.1.1 SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE PER IBC 1705,12 SHALL BE REQUIRED FOR SEISMIC FORCE -RESISTING <br />N ~ 5 z ~ <br />SYSTEMS IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C, D, E OR F FOR THE FOLLOWING: <br />w���ow <br />x a <br />A. SPECIAL INSPECTIONS OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE THE QUALITY ASSURANCE <br />REQUIREMENTS OF AISC 341. <br />oa®`" <br />B. PERIODIC SPECIAL INSPECTION OF WELDING OPERATIONS OF COLD -FORMED STEEL ELEMENTS OF THE SEISMIC <br />FORCE -RESISTING SYSTEM. <br />C. PERIODIC SPECIAL INSPECTION OF SCREW ATTACHMENT, BOLTING, ANCHORING AND OTHER FASTENING OF <br />COLD -FORMED STEEL COMPONENTS WITHIN THE SEISMIC FORCE RESISTING SYSTEM, INCLUDING SHEAR WALLS, <br />DIAPHRAGMS, COLLECTORS, BRACES, AND HOLDOWNS. <br />D. PERIODIC SPECIAL INSPECTION DURING THE ANCHORAGE OF STORAGE RACKS IN STRUCTURES ASSIGNED TO <br />SEISMIC DESIGN CATEGORY D, E, OR F FOR RACKS 8-FT OR GREATER IN HEIGHT. <br />LL <br />ev <br />1-4CD <br />18.1.2 TESTING AND QUALIFICATION FOR SEISMIC RESISTANCE PER IBC 1705.13 SHALL BE REQUIRED FOR SEISMIC <br />FORCE -RESISTING SYSTEM IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C, D, E OR F FOR THE FOLLOWING:' <br />A. NONDESTRUCTIVE TESTING FOR STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE QUALITY ASSURANCE <br />REQUIREMENTS OF RISC 341, <br />;t <br />? <br />Ul <br />Uj <br />Qj <br />U <br />0 <br />V) <br />IJ <br />CL <br />CL <br />p <br />cn <br />l Ip <br />2215 North 30th Street, Suite 300 Tacoma, WA 98403 <br />253.383.2422 TEL 253,383,2572 FAX www.ahbixom WEB <br />I <br />