My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6214 BROADWAY 2022-06-27
>
Address Records
>
BROADWAY
>
6214
>
6214 BROADWAY 2022-06-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2022 2:11:03 PM
Creation date
6/27/2022 2:10:38 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
6214
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> distance requirements of Sections R314 Item 4 and R314.3.1. Specify additional <br /> performance requirements based on the location(s). <br /> Response:These alarms are existing and comply with the distance requirements of sections 8314 item 4 <br /> and R314,3.1. Genera!note#8 has been added for the contractor to verify. <br /> 4. Construction Note 7 on Sheet 3 states to install grab bars "per detail shown".The referenced <br /> detail(s) is not included.See Section R330.8 <br /> Response:Plans have been revised to include this missing detail. <br /> 5.Sheet 4 appears to include unused deck details. It is noted that the Garage Framing Plan <br /> 1/Sheet 1 references Detail 1/Sheet 4 for a ledger connection.The deck details are not <br /> suitable;details consistent with the proposed work should be included.See Sections R106.1.1 <br /> and R301.1. <br /> Response:Proposed framing plan is in conformance with!RC Section RS02 and the corresponding Table <br /> R502.3.1 for floor joist spans by lumber species and grade and as per garage framing note#1. Please <br /> clarify what is missing. <br /> 6.The exterior walls and ceiling for the converted garage enclose new conditions space. <br /> Insulation complying with WSEC Table R 402.1.1 should be specified in the drawings. <br /> Response: The plans have been revised to include construction note#11 that directs the contractor to <br /> provide insulation per exterior wall detail on sheet 4 already included. <br /> 7. Energy credits per WSEC Table R406.3 are listed on Sheet 3.The credits do not include the <br /> fuel normalization credit per Table R406.2. Based on Construction Note 1 indicated electricresisting <br /> heating,a credit of-1.0 per Item 3 is required.Additional credits from Table R406.2 <br /> are required.Alternatively,the heating system should be revised. <br /> Response: The plans have been revised to indicate that a heat pump will be installed in each new room. <br /> Refer to construction note#1. Energy credits per WSEC Table R406.3 have been revised as well. <br /> 8.The new bathroom should specify exhaust fans including the minimum required performance <br /> rates per IRC Table M1505.4.4(1). <br />
The URL can be used to link to this page
Your browser does not support the video tag.