My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
305 SE EVERETT MALL WAY VISION WORKS 2022-06-28
>
Address Records
>
SE EVERETT MALL WAY
>
305
>
VISION WORKS
>
305 SE EVERETT MALL WAY VISION WORKS 2022-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2022 8:03:35 AM
Creation date
6/27/2022 3:55:19 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
305
Tenant Name
VISION WORKS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6414 V VVL.V I CIj411GII ICI IW!WI V41111110I Ula1 LJ411411R90 111,1441119 VI Vat./ ,w M I -r ........ __--. <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> 'Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.9.2.2 Steam condensate • For buildings with on-site steam heating <br /> • systems heat recovery systems.indicate condensate water heat • <br /> recovery and use of recovered heat <br /> For buildings that use off-site generated steam <br /> where condensate is not returned to the • <br /> source,indicate on-site condensate water pea! ..-... <br /> recovery <br /> • <br /> C403.9.1.3 Refrigeration For buildings with food service,meat or deli <br /> condenser heat departments that have>5(X).0J(X)Btu/h of <br /> recovery - remote refrigeration capacity for coolers/ <br /> freezers,indicate condenser heat recovery and <br /> use of captured energy(service water heating, <br /> space heating,or dehumidification reheating) _ <br /> For buildings with?40,00O sf conditioned <br /> floor area and> I.000,000 Btu/h of remote <br /> refrigeration capacity.indicate condenser heat <br /> recovery to pre-heat service water;indicate <br /> remaining recovered beat is applied to space • <br /> heating or dehumidification reheating <br /> • <br /> C403.9.2.4 T-Teat recovery for For buildings that operate>70 hour per week, <br /> space heating • that are not served by a DOHS with energy <br /> recovery.and have> 1,500,000 IBut/h of heat <br /> • rejection capacity and>_0.45 cftn per sf of <br /> design minimum supply airflow with reheat, <br /> • indicate condenser heat recovery is provided <br /> for space heating that complies with Sections <br /> C403.9.2.4.I or C403.9.2.4.2 or C403.9.2.-1.4 <br /> C403.9.2.4.1 Water to water heat Indicate that 9€)io or more of the total <br /> C:403.9.2.4.4 recovery building space heating and ventilation air <br /> design loads are served by heat energy <br /> • rejected from either a heat recovery chiller or <br /> • <br /> the cooling loop of water to water heat pump <br /> equipment <br /> • C403,92.4.2 Exhaust heat recovery Indicate that waste heat is recovered from <br /> least 90`ii-of the total building exhaust airflow <br /> such that leaving exhaust air temperature <br /> while in hear recovery mode is 55 deg F dry • <br /> bulb;note exhaust air systems eligible for <br /> exception to this requirement <br /> C403.9.2.4.3 Process heat recovery In spaces with 5 watts per sf year-round <br /> cooling loads from lights and equipment. • <br /> indicate these spaces are served by water-- <br /> cooled equipniettt configured for heat <br /> • recovery <br /> • If these spaces are served by economizer(air <br /> or water),indicate automatic controls are <br /> • configured to disable economizer operation <br /> • while system is in heat recovery mode <br /> MULTIPLE ZONE AIR SYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.