Laserfiche WebLink
6414 V VVL.V I CIj411GII ICI IW!WI V41111110I Ula1 LJ411411R90 111,1441119 VI Vat./ ,w M I -r ........ __--. <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> 'Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.9.2.2 Steam condensate • For buildings with on-site steam heating <br /> • systems heat recovery systems.indicate condensate water heat • <br /> recovery and use of recovered heat <br /> For buildings that use off-site generated steam <br /> where condensate is not returned to the • <br /> source,indicate on-site condensate water pea! ..-... <br /> recovery <br /> • <br /> C403.9.1.3 Refrigeration For buildings with food service,meat or deli <br /> condenser heat departments that have>5(X).0J(X)Btu/h of <br /> recovery - remote refrigeration capacity for coolers/ <br /> freezers,indicate condenser heat recovery and <br /> use of captured energy(service water heating, <br /> space heating,or dehumidification reheating) _ <br /> For buildings with?40,00O sf conditioned <br /> floor area and> I.000,000 Btu/h of remote <br /> refrigeration capacity.indicate condenser heat <br /> recovery to pre-heat service water;indicate <br /> remaining recovered beat is applied to space • <br /> heating or dehumidification reheating <br /> • <br /> C403.9.2.4 T-Teat recovery for For buildings that operate>70 hour per week, <br /> space heating • that are not served by a DOHS with energy <br /> recovery.and have> 1,500,000 IBut/h of heat <br /> • rejection capacity and>_0.45 cftn per sf of <br /> design minimum supply airflow with reheat, <br /> • indicate condenser heat recovery is provided <br /> for space heating that complies with Sections <br /> C403.9.2.4.I or C403.9.2.4.2 or C403.9.2.-1.4 <br /> C403.9.2.4.1 Water to water heat Indicate that 9€)io or more of the total <br /> C:403.9.2.4.4 recovery building space heating and ventilation air <br /> design loads are served by heat energy <br /> • rejected from either a heat recovery chiller or <br /> • <br /> the cooling loop of water to water heat pump <br /> equipment <br /> • C403,92.4.2 Exhaust heat recovery Indicate that waste heat is recovered from <br /> least 90`ii-of the total building exhaust airflow <br /> such that leaving exhaust air temperature <br /> while in hear recovery mode is 55 deg F dry • <br /> bulb;note exhaust air systems eligible for <br /> exception to this requirement <br /> C403.9.2.4.3 Process heat recovery In spaces with 5 watts per sf year-round <br /> cooling loads from lights and equipment. • <br /> indicate these spaces are served by water-- <br /> cooled equipniettt configured for heat <br /> • recovery <br /> • If these spaces are served by economizer(air <br /> or water),indicate automatic controls are <br /> • configured to disable economizer operation <br /> • while system is in heat recovery mode <br /> MULTIPLE ZONE AIR SYSTEMS <br />