Laserfiche WebLink
LU IU V 11,M,,I Scl4uu GI I IVA S.A./1 I II IIGI l,101 IJUIIUII IVO II wIUUlny vl'JuJ I.a.,Iw w I.-.v...I .-..... . <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> 'Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.6.I Air systems serving Identify supply air systems serving multiple <br /> multiple zones ' - zones and the zones they serve on plans; <br /> indicate whether system is VAV and method <br /> of primary air control:or provide supporting <br /> documentation for applied exception to VAV • <br /> C403.6.I VAV air terminal Provide equipment schedules on plans that list <br /> primary supply all VAV air terminals and types(fan-powered <br /> airflow series and parallel air terminals,single duct <br /> and dual duct air terminals,etc) <br /> For each air terminal include:maximum <br /> • <br /> primary supply airflow rates during zone peak <br /> heating and zone peak cooling;maximum <br /> terminal airflow during reheating,rccooling or <br /> rinsing;minimum ventilation airflow rate,and <br /> the basis for these values:if IMC or ASIIRAE <br /> 62.1 multiple zone equation is the basis for <br /> minimum flow rates,provide this calculation <br /> on plans <br /> C403.6.2 Single duct VAV Indicate single duct terminal units are <br /> terminal units configured to reduce primary supply air <br /> before reheating or recooling <br /> C403.6.3 Dual duct systems- For systems with separate warm air and cool <br /> terminal units air duct:,indicate terminal units are <br /> configured to reduce the flow from one duct <br /> to minimum before mixing with air from the • <br /> other duct <br /> C403,6.8C4() VAV system static- Indicate locations of duct static pressure <br /> 3.6.9 pressure sensors and sensors on plans;include at least one sensor <br /> DDC set points per major duct branch:verify controller <br /> setpoint pressure at each sensor is S 1.2 inch <br /> w.g. <br /> For systems with zone level DDC.indicate <br /> controls arc configured to monitor zone <br /> damper positions and reset static pressure <br /> setpoint based on the zone requiring most <br /> pressure:include control logic that <br /> automatically detects and generates an alarm <br /> if any zone excessively drives reset logic,and <br /> allows building operators to exclude zones <br /> from reset logic <br /> C403.6.4 VAN/system supply Indicate controls automatically reset supply <br /> air reset air temperature in response to building loads <br /> or outdoor air temperature:or exception <br /> applied <br /> C403.6.5 Multiple-zone VAV For systems with zone level DDC controls, <br /> system ventilation indicate controls are configured to <br /> optimization controls automatically reduce outdoor airflow in <br /> - response to changes in system ventilation <br /> efficiency;or exception applied <br /> � (;\ 125 <br />