My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
305 SE EVERETT MALL WAY VISION WORKS 2022-06-28
>
Address Records
>
SE EVERETT MALL WAY
>
305
>
VISION WORKS
>
305 SE EVERETT MALL WAY VISION WORKS 2022-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2022 8:03:35 AM
Creation date
6/27/2022 3:55:19 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
305
Tenant Name
VISION WORKS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
cv iv vvv�-v�wyuu I11011w wl vvnnnGlU.iai vuuuul0 uwiuuuly Vivui+ISa Iw Ix 1W UVOI J JLV11GJ ax au INK -- ',mu w1.,..........; '$ •.—•—..,••••••a•---.___.. <br /> The folltzwing information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> 'Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.6.10.1te Maximum allowable For each multiple-zone VAV system,provide <br /> to ti system brake calculations that verify total fan system bhp is <br /> horsepower 90 :of the total allowable fan system bhp <br /> per Option 2 equation in Table C403.8.1.1 <br /> C403.6.10.1te Fan-powered terminal ,Indicate all series and parallel fan-powered <br /> in 9 unit motor and terminals have electronically commutated <br /> control - motors(ECM):indicate DDC control system <br /> is configured to vary air terrttinal fan speed as <br /> a function of the load:indicate fan speed <br /> during periods of low heating.low cooling,or <br /> ventilation-only mode is S 66%of peal: <br /> design air flow,or provide supporting <br /> - documentation for applied exception <br /> • <br /> C403.6.10. Application of single Indicate VAV terminal types on plans:verify <br /> hem 10 duet and fan-powered " fan-powered terminal units only serve <br /> terminal units perimeter zones with envelope loads and <br /> interior zones with high occupant density and <br /> DCV per C403.7.I;verify all other zones are <br /> served by single duct terminal units <br /> C4ft3.6.10, Fan-powered termmal Indicate DDC controls are configured to <br /> Item II unit primary air reset automatically reset the primary supply air cftn <br /> setpoint of all fan-powered terminal units to <br /> the minimum required to maintain ventilation <br /> during occupied heating or deadbard mode, <br /> based upon the VAS/air handling unit <br /> minimum ventilation air fraction <br /> C403.6.l0,lte Controls for high For zones> 15t)sf with high occupant density <br /> m 12 occupant density f>_25 people/ 1000 sf),indicate zone is <br /> spaces served by a dedicated terminal unit with DCV <br /> control that resets terminal unit ventilation <br /> setpoint based on measured CO2:also <br /> indicate occupancy sensor control that <br /> automatically reduces minimum ventilation to <br /> zero and sets back room heating and cooling <br /> setpoints by 5'F when space in unoccupied <br /> C t03.6.10, Dedicated cooling For data centers and server,electronic <br /> Item 13 systems serving data equipment telecom or similar spaces with <br /> centers and server, design cooling loads>5 W/sf,indicate spaces <br /> electronic equipment - are served by dedicated cooling systems that <br /> and telecom spaces are independent of the HPVAV systems <br /> serving the rest of building <br /> Indicate dedicated cooling systems are <br /> configured for 100%air economizer <br /> operation and comply with all related <br /> economizer requirements per C403.5(without <br /> economizer exceptions).or heat recovery per <br /> C403.5,Exception 9 <br /> C403.6.10. Central plant Indicate whether systems are served by a high <br /> Item 14 efficiency efficiency heating water plant,or a high <br /> efficiency chilled water plant <br /> 21 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.