My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
305 SE EVERETT MALL WAY VISION WORKS 2022-06-28
>
Address Records
>
SE EVERETT MALL WAY
>
305
>
VISION WORKS
>
305 SE EVERETT MALL WAY VISION WORKS 2022-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2022 8:03:35 AM
Creation date
6/27/2022 3:55:19 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
305
Tenant Name
VISION WORKS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LV I VV%JLV IN.G4U1IGIIICII.IVI VVll llllcildgl IJUIIUII 1U0 II IldUUI1 I VI VYi.I I\L,1\J Nt..-r v sw.rv...........•.• ..-......._ _.__._• <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> 'Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> If complying via high efficiency heating water <br /> • plant:Indicate all VAN`terminals have <br /> hydronic heating coils served by a heating <br /> writer system with either cats-fired boiler(s) <br /> with thermal efficiency(Ett)?92%,air-to- <br /> water heat pumps.or heat recovery chillers; <br /> indicate hydronic heating cods are sized per a <br /> maximum 120T entering seater temperature <br /> during peak demand <br /> If complying via high efficiency chilled water <br /> • plant:Indicate all VAV air-handlers have <br /> cooling coils served by chillers with rated <br /> IPLV efficiency that exceeds WSEC listed <br /> IPLV by at least 25% per Table C403.3.2(7) <br /> (note water-cooled'PIN is max,all others are <br /> min):indicate smallest chiller or compressor <br /> in plant is S 20%of the total plant capacity, <br /> • or provide thermal storage sized for>_20%of <br /> total plant capacity <br /> C403.6.10. Fault detection and Indicate DDC system includes automatic fault <br /> Item 15 diagnostics detection and diagnostics(FDD)configured <br /> to monitor operation and provide fault <br /> reporting of all required parameters for all <br /> VAV air handlers and VAV air terminal units <br /> in the HPV•AV system <br /> HIGH EFFICIENCY SINGLE-ZONE VAV SYSTEMS-EXCEPTION TO C403.3.5 DOAS,MUST COMPLY WITH ALL 8 PROVISIONS TO <br /> BE ELIGIBLE <br /> C403,12, Air economizer Indicate system is configured for 100%air <br /> Item 1 economizer operation and complies with all <br /> related economizer requirements per C403,5 <br /> (without economizer exceptions) <br /> C403.12. Direct digital controls Provide DDC controls for all components of - <br /> Item 2 (DDC) system per C403.4.11 (regardless of system <br /> • sine);identify all DDC system input/output <br /> • <br /> control points;indicate capability for trending <br /> and graphical display <br /> • <br /> C403.12.ltem Outdoor airflow For systems with minimum required outdoor <br /> 3 measurement and air> 1,000 efm.provide an airflow <br /> control monitoring station that is configured to <br /> measure outdoor air intake under all load <br /> conditions:indicate controls that adjust <br /> outdoor air elm via DCV per C403.7.1 <br /> • <br /> C403.12,Itein Maximum allowable For each single-zone VAV system,provide <br /> I system brake calculations that verify total fan system bhp is <br /> horsepower .90%of the total allowable fan system bhp <br /> per Option 2 equation in Table C403.8.1.I <br /> - C403.12. Supply airflow Provide controls that adjust supply airflow <br /> Item 5 control based on the heating and cooling loads: <br /> indicate control sequence that limits minimum <br /> — -_ -fan speed-to 30%%{af peak deign airflow-or <br /> required ventilation during unoccupied mock;, • <br /> • whichever is less <br /> 2 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.