Laserfiche WebLink
Ly,V V VVLV I NVMUlI CI I,CI ItO IVI VVI 111ICI t,Ial LJU1141,I O„R,IUUll, V,LOAF!I SC,I l..,l%I5t VVGI .J JLVI IGO tx all Ill -- f.U11,,,1.J1G,GU.,y VLVL, 141LLrt,llu,iw nw Ivw.te.... <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> ' 'Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> .._.. .............._.._ <br /> C405.6 ElectricalInclude electrical transformer schedule on <br /> transformers electrical plans;indicate transformer type, <br /> :;size,efficiency,or exception taken <br /> YES i C405.11 Feeders and branch Provide documentation that demonstrates <br /> circuits maximum voltage drop across feeders and i <br /> i branch circuits does not exceed 5% • <br /> C405.7 Dwelling unit ' Indicate on electrical plans that each dwelling <br /> electrical energy unit in Group R-2 has a separate electrical • <br /> consumption energy meter. <br /> C.405 8 'Electric motor : Include ail motors.including fractional hp <br /> efficiency ; motors.in electric motor schedule on <br /> electrical plans;indicate motor type. <br /> `horsepower,rpm,rated efficiency,or . <br /> exception applied <br /> C405.9,I Elevator cabs For luminaires in each elevator cab,provide <br /> calculations that demonstrate average efficacy <br /> is not less than 35 lumens per watt. <br /> For elevators that do not have an integral air <br /> conditioning system.indicate rated watts per <br /> • elm for elevator cab ventilation fans do not <br /> exceed 0.33 Watts per cfm <br /> Indicate automatic controls that de-energize <br /> lighting and ventilation fans when elevator is <br /> stopped and unoccupied for a period of 15 <br /> minutes or more <br /> C405.9.2 Escalators and Indicate escalators comply with ASME <br /> moving walks A 17.1/CSA B-14c automatic controls arc <br /> configured to reduce operational speed to the <br /> minimum permitted when not ill use <br /> C405 9.3 Regenerative drive Indicate all one-way down or reversible <br /> escalators are provided with a variable <br /> frequency regenerative drive <br /> DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING(CX) <br /> YES C408.4 Scope of electrical i Indicate that all electrical systems <br /> power and lighting (receptacles,transformers,motors,vertical <br /> systems and horizontal transportation)for which the <br /> • commissioning WSEC requires control functions and/or <br /> configuration to perform specific functions <br /> are required to be commissioned <br /> NA Where total building lighting load is>20 kW, <br /> or where total lighting load of luminaires <br /> : requiring daylight sensing and/or occupancy • <br /> control>10 kW,indicate that all automatic <br /> lighting control systems are required to be <br /> . i commissioned;or provide building lighting <br /> power calculation demonstrating eligibility for <br /> exception <br /> YES C405.13 Commissioning Indicate Cx requirements in plans and <br /> • <br /> C408.1.1 requirements in specifications for all applicable electrical and • <br /> C408.1.2 construction lighting control systems per C408 <br /> C408.1.4.2 , documents <br /> C103.6.3 <br /> °I\ I0 <br />