My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4122 COLBY AVE A B 2022-07-20
>
Address Records
>
COLBY AVE
>
4122
>
4122 COLBY AVE A B 2022-07-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2022 11:01:50 AM
Creation date
7/20/2022 11:01:17 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4122
Unit
A B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> REPLY LETTER TO E STE REVISIONS <br /> Sept 03, 2020 <br /> Owner: 4120 Colby LLC <br /> Job Address: 4120E&4120A Colby Ave. Everett <br /> Permit No. B2004-029 <br /> RE: Building Permit Re-review Letter <br /> Dear Jeff, <br /> In response to the Re-review letter dated May 22, 2020. <br /> Note:We have worked with Thad Newport to modify the Impervious surface area and have brought it <br /> under 2,000 sq.ft.So there is a new drainage plan proposed(attached)along with a new Sheet 13 to <br /> address some of the requested revisions. <br /> SITE PLAN-ALL ITEMS 1-13 Revised on Site Plan <br /> 1. The address for this project is incorrect,a new address needs to be assigned. <br /> 2. A separate demolition permit needs to be issued for the garage removal. <br /> 3. The high calculations are different on 2 sheets. "P1"shows 35.9 feet for all points,Sheet"P3"shows <br /> a different elevation for each point. <br /> 4. The contour lines shown on pages P3 and P are different and are labeled at different elevations. <br /> 5. The site plan does not show heat pumps that are shown on the floor plan. <br /> 6. The site plan is not clear as to the proposed footprint of the building. <br /> 7. The site plan does not show the landings required between the 2 buildings. <br /> 8. Two, minimum 36 inch landings are required at the entrance doors in the carport area.This space is <br /> shown as parking for the required parking spaces. <br /> 9. The proposed building dimensions are not shown on the site plan. <br /> 10. The dimensions of the parking spaces are not shown on the site plan. <br /> 11. Please remove the existing garage footprint and dimensions. <br /> 12. Roof projections are limited to 18 inches in the 5 foot side setback.The overhang shown on the north <br /> side of the building is shown at 24 inches on the plans. <br /> 13. The portion of the second and third floor cantilever on the North side that project 18 inches into the <br /> 5 foot side yard setback, is not allowed to have an overhang. <br /> ARCHITECTURAL <br /> 14. The plans show the width of the stairs at 34 inches please correct to the minimum 36-inch <br /> requirement. <br /> Revised Sheet 3 <br /> 15. The notes on the plans call out wall framing at 24 inches on center but none of the engineering <br /> drawing or tables specify the spacing of the wall framing. <br /> All wall framing notes indicate 16"O.C.On plans and engineering. <br /> Page 9 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.