My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
203 MADISON ST 2022-07-20
>
Address Records
>
MADISON ST
>
203
>
203 MADISON ST 2022-07-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2022 3:02:56 PM
Creation date
7/20/2022 3:02:12 PM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
203
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• ! <br /> Capital Architects Group pc <br /> 2813 Rockefeller Ave.Everett,WA 982010 ph:425.317.8017• fax:425.317.8489 <br /> 07.30.2021 IIECELIVEICity of Everett Permit Services <br /> 3200 Cedar Street <br /> Everett,WA 98201 AUG 2 4 t021 <br /> Attention: Rakeeb Khan CITY EVERETT <br /> RE: Plan Check Number B2106-044, First Building Review Permit Services <br /> Owner: Ryan Pimentel <br /> Job Address: 203 Madison Avenue Everett,WA 98203 <br /> Rakeeb, <br /> Thank you for your review comments. Please note our written responses for each item below: <br /> General <br /> 1. The governing codes should be updated to the current code year 2018 on Sheet A-1.0. <br /> Response: <br /> We acknowledge that the governing codes should be updated to the current code year 2018 and have <br /> revised Sheet A-1.0 and plans to reflect this. <br /> Architectural <br /> 1. Detail 2/A-6.0 shows R-38 insulation in the ceiling. Plans should show a requirement of <br /> R-49 insulation in the ceiling. Footnote e of Table R402.1.1 refers to single rafter or vaulted ceilings.Table <br /> R402.1.1 <br /> Response: <br /> Refer to revised sheet A-6.0/Detail 2 for correction of ceiling insulation specification. <br /> 2. Plans should show smoke alarms installed outside of each separate sleeping area in immediate vicinity of <br /> the bedrooms.See Section R314.3. <br /> Response: <br /> Refer to revised sheet A-2.1 for additional smoke alarm installed outside of each separate sleeping area <br /> per section R314.3. <br /> 3. Plans should show carbon monoxide alarms installed outside of each separate sleeping area in the <br /> immediate vicinity of the bedrooms. See Section R315.3. <br /> Response: <br /> Refer to revised sheet A-2.1 for additional carbon monoxide alarm installed outside of each separate <br /> sleeping area per section R314.3. <br /> Structural <br /> See letter attached for Structural Response Correction letter. <br /> Sandra Higgins <br /> Capital Architects Group Pc <br /> 1 Page <br />
The URL can be used to link to this page
Your browser does not support the video tag.