Laserfiche WebLink
11 <br />2 <br />e <br />V <br />R <br />11 <br />I <br />IQ <br />0 <br />TELECOM OUTLETS <br />OUTLET <br />OUTLET, CEILING MOUNTED <br />FURNITURE SYSTEMS OUTLET <br />, <br />OUTLET, MOUNTED IN FLOOR BOX <br />OUTLET, MOUNTED IN POKE THRU <br />(' <br />OUTLET, MOUNTED IN POWER POLE <br />TELECOM OUTLET TYPES <br /># <br /># INDICATES QUANTITY OF DATA JACKS, PULLSTRING <br />ALWAYS PROVIDED. WHERE NO QUANTITY IS NOTED, <br />2 DATA JACKS AND PULLSTRING. <br />AC <br />MOUNTED 3" ABOVE COUNTER BACKSPLASH <br />B <br />BLANK FACEPLATE, ROUGH -IN ONLY <br />'p D <br />DIRECT CONNECTION TO PANEL <br />M <br />PATIENT MONITORING <br />P <br />PAY TELEPHONE <br />y R <br />RACEWAY MOUNTED <br />\27 W <br />WALL. MOUNTED TELEPHONE HANDSET OUTLET <br />gp WAP <br />WIRELESS ACCESS POINT CONNECTION <br />CIRCUITS <br />RECEPTACLES <br />EMERGENCY <br />NORMAL <br />SINGLE RECEPTACLE, 120V <br />SINGLE RECEPTACLE, 120V, CEILING MOUNTED <br />DUPLEX RECEPTACLE, 120V <br />DUPLEX RECEPTACLE, 120V, CEILING MOUNTED <br />DOUBLE DUPLEX RECEPTACLE, 120V <br />DOUBLE DUPLEX RECEPTACLE, 120V, CEILING <br />MOUNTED <br />SPLIT WIRED RECEPTACLE, 120V, TOP CONTROLLED, <br />BOTTOM CONSTANTLY ENERGIZED <br /># <br /># <br />RECEPTACLE, NEMA # <br /># <br /># <br />RECEPTACLE, NEMA #, CEILING MOUNTED <br /># <br /># <br />COMBINATION RECEPTACLE, NEMA # AND 120V <br />FURNITURE SYSTEMS RECEPTACLE, 120V <br />N/A <br />�� <br />[LEI, -1 <br />INDICATES FULLY CONTROLLED <br />N/A <br />! T <br />INDICATES 15A <br />N/A <br />(I <br />INDICATES TWIST LOCK <br />NIA <br />L) <br />:; I <br />INDICATES MOUNTED 3" (75 MM) ABOVE COUNTER <br />.� <br />BACKSPLASH <br />N/A <br />MULTI -SERVICE FLOOR BOX (RECEPTACLES/OUTLETS <br />AS INDICATED) <br />N/A <br />®;.V' <br />MULTI -SERVICE POKE THRU (RECEPTACLES/OUTLETS <br />AS INDICATED) <br />N/A <br />` <br />MULTI -SERVICE POWER POLE <br />(RECEPTACLES/OUTLETS AS INDICATED) <br />N/A <br />0 <br />MULTI -SERVICE ASSEMBLY (RECEPTACLES/OUTLETS <br />AS INDICATED) <br />N/A <br />CLOCK RECEPTACLE, 120V <br />CORD DROP, 120V <br />CEILING CORD DROP, 120V <br />RECEPTACLE TYPES <br />9, A <br />ARC FAULT CIRCUIT INTERRUPTER <br />AT <br />ARC FAULT CIRCUIT INTERRUPTER AND TAMPER <br />RESISTANT <br />D <br />DEDICATED CIRCUIT <br />G <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GT <br />GROUND FAULT CIRCUIT INTERRUPTER AND TAMPER <br />RESISTANT <br />I <br />ISOLATED GROUND <br />S <br />SURGE PROTECTOR <br />T <br />TAMPER RESISTANT <br />U <br />INTEGRAL USB PORT(S) <br />WP <br />WEATHER RESISTANT COVER <br />CONTROLS <br />®' <br />NON -FUSED SAFETY SWITCH <br />FUSED SAFETY SWITCH, FUSE RATING INDICATED <br />COMBINATION MOTOR STARTER AND FUSED SAFETY <br />SWITCH, FUSE RATING INDICATED <br />MOTOR STARTER <br />MANUAL MOTOR STARTER <br />AUTOMATIC DOOR PUSHPLATE <br />DEAD FRONT GFCI <br />EMERGENCY SHUTDOWN <br />ENCLOSED CIRCUIT BREAKER <br />® <br />ENCLOSED CONTACTOR <br />PUSH BUTTON CONTROL STATION <br />,IM <br />TOGGLE SWITCH, MOTOR RATED <br />TOUCHLESS AUTOMATIC DOOR OPENER <br />DDC <br />DIRECT DIGITAL CONTROL PANEL <br />R <br />RELAY <br />e <br />THERMOSTAT <br />TC <br />TIME CLOCK <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />ELECTRICAL EQUIPMENT <br />208V OR 240V POWER PANELBOARD <br />480V OR 600V POWER PANELBOARD <br />EQUIPMENT CABINET OR PANEL <br />EQUIPMENT CONNECTION, FILL INDICATES <br />EMERGENCY CIRCUIT <br />`—' <br />GROUND BAR <br />MOTOR CONNECTION, 10 <br />MOTOR CONNECTION, 30 <br />BUS DUCT <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />BUS DUCT PLUG <br />SPD <br />SURGE PROTECTIVE DEVICE <br />® <br />TRANSFORMER, NOT TO SCALE <br />�r <br />TRANSFORMER, DRAWN TO SCALE <br />LIGHTING <br />SINGLE POLE SWITCH <br />INDICATES WIRELESS CONTROL <br />INDICATES BATTERY POWER <br />a <br />LOWER-CASE LETTER(S) NEAR SWITCH DENOTE <br />SWITCH LEG(S) <br />v 2 <br />DOUBLE POLE SWITCH <br />a 3 <br />THREE-WAY SWITCH <br />4 <br />FOUR. -WAY SWITCH <br />D <br />DIMMER SWITCH <br />`` K <br />KEY OPERATED SWITCH <br />$ LV <br />MOMENTARY CONTACT LOW VOLTAGE SWITCH <br />1 0 <br />�s <br />OCCUPANCY SENSOR SWITCH <br />P <br />SWITCH WITH PILOT LIGHT <br />PC <br />PHOTOCELL SWITCH <br />T <br />TIMER SWITCH <br />® COMBINATIONS OF THE ABOVE DESIGNATIONS <br />MAY BE USED <br />CS # <br />LOW VOLTAGE AGE CONTROL STATION, # INDICATES <br />DSC <br />STATION IDENTIFICATION <br />DIMMING SYSTEM CONTROL PANEL <br />ELCU <br />�-J <br />EMERGENCY LIGHTING CONTROL UNIT <br />LCP <br />LIGHTING CONTROL PANEL <br />®P <br />COMBINATION OCCUPANCY/PHOTO SENSOR SWITCH, <br />CEILING MOUNTED <br />OS <br />OCCUPANCY SENSOR SWITCH, CEILING MOUNTED <br />PC <br />PARTITION SENSOR CONTROL <br />PS <br />PHOTO SENSOR CONTROL <br />PS <br />PHOTO SENSOR CONTROL, CEILING MOUNTED <br />R <br />RELAY <br />® <br />LOW VOLTAGE TRANSFORMER <br />FIRE ALARM <br />FIRE SERVICE PHONE STATION OUTLET <br />FLAME DETECTOR <br />CO <br />GAS DETECTOR, CARBON MONOXIDE <br />® <br />HORN AND STROBE LIGHT, CEILING MOUNTED <br />HORN AND STROBE LIGHT, WALL MOUNTED <br />®, <br />REMOTE INDICATOR, CEILING MOUNTED <br />®� <br />REMOTE INDICATOR, WALL MOUNTED <br />SPEAKER AND STROBE LIGHT, CEILING MOUNTED <br />E14 <br />SPEAKER AND STROBE LIGHT; WALL MOUNTED <br />.�a <br />STROBE LIGHT, CEILING MOUNTED <br />sQ® <br />STROBE LIGHT, WALL MOUNTED <br />AIM <br />ADDRESSABLE INPUT MODULE <br />ARCM <br />AREA OF REFUGE COMMUNICATION MASTER UNIT <br />ARCR <br />AREA OF REFUGE COMMUNICATION REMOTE UNIT <br />0 <br />ADDRESSABLE OUTPUT MODULE <br />® <br />ELECTRICALLY OPERATED SMOKE OR FIRE/SMOKE <br />LpCLj <br />DAMPER CONNECTION <br />DOOR CLOSER <br />DH <br />DOOR HOLDER <br />IDD <br />CHIME, WALL MOUNTED <br />� <br />HORN, CEILING MOUNTED <br />D <br />HORN, WALL MOUNTED <br />PULL STATION <br />FAA <br />FIRE ALARM ANNUNCIATOR <br />FACP <br />FIRE ALARM CONTROL PANEL <br />FAT <br />FIRE ALARM TRANSMITTER <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />GAP <br />GRAPHIC ANNUNCIATOR PANEL <br />H <br />HEAT DETECTOR <br />NAC <br />FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT PANEL <br />PS <br />PRESSURE DETECTOR/SWITCH <br />R <br />INTERFACE RELAY <br />S <br />SMOKE DETECTOR, CEILING MOUNTED <br />� <br />SMOKE DETECTOR, WALL MOUNTED <br />SS <br />SMOKE DETECTOR, SINGLE STATION <br />S H <br />SMOKE/HEAT DETECTOR <br />WSMOKE/HEAT/CARBON <br />O <br />MONOXIDE DETECTOR <br />SPEAKER, CEILING MOUNTED <br />SPEAKER; WALL MOUNTED <br />VS <br />VALVE SUPERVISORY TAMPER SWITCH <br />FLOW DETECTOR/SWITCH <br />HEATISMOKE <br />TYPES <br />IBC#/F# <br />FIXED TEMPERATURE, # INDICATES °C OR OF <br />EH 1 <br />'._. R <br />RATE OF RISE <br />CORC#/F#COMBINED RATE OF RISE/FIXED TEMPERATURE <br />�S/AS <br />AIR SAMPLING <br />0BR <br />BEAM DETECTOR RECEIVER <br />BT <br />BEAMDETECTOR TRANSMITTER <br />S E <br />ELEVATOR RECALL <br />SI <br />IONIZATION <br />CIS>1D <br />IN DUCT <br />p <br />PHOTOELECTRIC <br />CIRCUITS <br />LUMINAIRES <br />EMERGENCY <br />NORMAL <br />N/A <br />L01 <br />LUMINAIRE IDENTIFICATION, SEE LUMINAIRES <br />SCHEDULE <br />NIA <br />L;f a <br />LOWER-CASE LETTER(S) NEAR LUMINAIRE DENOTE <br />SWITCH LEG(S) <br />RECESSED RECTANGULAR LUMINAIRE, DRAWN TO <br />SCALE <br />SURFACE MOUNTED RECTANGULAR LUMINAIRE, <br />DRAWN TO SCALE <br />RECESSED VOLUMETRIC LUMINAIRE, DRAWN TO <br />SCALE <br />STRIP LUMINAIRE, LENGTH TO SCALE <br />WALL MOUNTED RECTANGULAR LUMINAIRE, LENGTH <br />TO SCALE (NUMBER OF MOUNTING POINTS WILL VARY <br />WITH THE LUMINAIRE LENGTH AND ARE NOT <br />INDICATED.) <br />® <br />1300 <br />RECESSED DOWNLIGHT LUMINAIRE <br />SURFACE MOUNTED CEILING LUMINAIRE <br />PENDANT MOUNTED LUMINAIRE <br />LINEAR PENDANT MOUNTED LUMINAIRE, LENGTH TO <br />SCALE (NUMBER OF MOUNTING POINTS WILT® VARY <br />M <br />WITH THE LUMINAIRE LENGTH AND ARE NOT <br />INDICATED.) <br />WALL MOUNTED LUMINAIRE <br />WALL MOUNTED VERTICALLY ORIENTED LUMINAIRE <br />® <br />WALL MOUNTED RECESSED LINEAR LUMINAIRE, <br />LENGTH TO SCALE <br />EXIT SIGN, FILLED SIDES INDICATE ILLUMINATED <br />N/A <br />ANNOTATION, ARROWS INDICATE DIRECTIONAL <br />GRAPHICS <br />WALL MOUNTED EXIT SIGN, FILLED SIDES INDICATE <br />N/A <br />ILLUMINATED ANNOTATION, ARROWS INDICATE <br />DIRECTIONAL GRAPHICS <br />N/A <br />EXIT SIGN WITH EMERGENCY BATTERY PACK <br />N/A <br />WALL MOUNTED EXIT SIGN WITH EMERGENCY <br />BATTERY PACK <br />N/A <br />EMERGENCY BATTERY PACK, NUMBER OF LAMPS NOT <br />INDICATED <br />tt <br />N/A <br />WALL MOUNTED EMERGENCY BATTERY PACK, <br />NUMBER OF LAMPS NOT INDICATED <br />KA <br />N/A <br />EMERGENCY WITH REMOTE BATTERY PACK, NUMBER <br />OF LAMPS NOT INDICATED <br />it <br />N/A <br />WALL MOUNTED EMERGENCY WITH REMOTE BATTERY <br />PACK, NUMBER OF LAMPS NOT INDICATED <br />Mt <br />RECESSED LINEAR WALL WASH LUMINAIRE, LENGTH <br />TO SCALE <br />LINEAR PENDANT MOUNTED WALL WASH LUMINAIRE, <br />LENGTH TO SCALE <br />RECESSED WALL WASH LUMINAIRE <br />SURFACE MOUNTED WALL WASH LUMINAIRE <br />PENDANT MOUNTED WALL WASH LUMINAIRE <br />RECESSED ACCENT LUMINAIRE <br />SURFACE MOUNTED ACCENT LUMINAIRE <br />PENDANT MOUNTED ACCENT LUMINAIRE <br />'y <br />v <br />MONOPOINT LUMINAIRE <br />N/A <br />TRACK LIGHTING <br />N/A <br />CONTINUOUS SOURCE LUMINAIRE, PATH AS <br />INDICATED <br />MULTI -LAMP ACCENT LUMINAIRE, NUMBER OF LAMPS <br />NOT INDICATED <br />WALL MOUNTED MULTI -LAMP ACCENT LUMINAIRE, <br />NUMBER OF LAMPS NOT INDICATED <br />EF <br />OVERCOUNTER TASK LUMINAIRE <br />® <br />cep <br />UNDERCABINET TASK LUMINAIRE <br />FIBER OPTIC REMOTE SOURCE <br />rl <br />STEP LUMINAIRE <br />I <br />ILLUMINATED SIGN <br />® <br />WALL MOUNTED ILLUMINATED SIGN <br />NIGHT LIGHT <br />WALL MOUNTED STROBE LIGHT <br />WORK DEFINITION <br />NEW WORK <br />EXISTING <br />o® m® <br />REMOVE EXISTING <br />REMOVE EXISTING ELECTRICAL EQUIPMENT <br />— — — <br />FUTURE <br />e = e ® <br />TEMPORARY, AS NOTED <br />?:## <br />KEY NOTE <br />??? <br />EQUIPMENT IDENTIFICATION <br />CIRCUITS <br />RACEWAY CONCEALED IN CEILING OR WALL. EXPOSED <br />RACEWAY IS ALLOWED ONLY WHERE NOTED. <br />--- — — <br />RACEWAY BELOW SLAB OR UNDERGROUND <br />�—� <br />RACEWAY UP <br />RACEWAY DOWN <br />RACEWAY CONTINUATION <br />—71 <br />RACEWAY STUB -OUT WITH BUSHING <br />9 <br />SURFACE RACEWAY (HORIZONTAL/VERTICAL) <br />la <br />PLUG STRIP (HORIZONTAL/VERTICAL) <br />J <br />JUNCTION BOX, CEILING OR ABOVE CEILING MOUNTED <br />JUNCTION BOX, WALL MOUNTED <br />J <br />JUNCTION BOX, IN -GROUND <br />PB <br />PULL BOX <br />#1C MULTI -CONDUCTOR, # INDICTA TES <br />QUANTITY <br />(D) DEMOLISH <br />(E) EXISTING <br />(N) NEW <br />(R) EXISTING TO BE RELOCATED <br />1/C SINGLE CONDUCTOR <br />A AMPS <br />A/C AIR CONDITIONING UNIT <br />AC ALTERNATING CURRENT <br />ACH ABOVE COUNTER HEIGHT <br />ACT ACOUSTICAL CEILING TILE <br />ADA AMERICANS WITH DISABILITIES ACT <br />ADJ ADJUSTABLE <br />AF AMP FRAME <br />AFC ABOVE FINISHED CEILING <br />AFCI ARC FAULT CIRCUIT INTERRUPTER <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AHJ AUTHORITY HAVING JURISDICTION <br />AHU AIR HANDLING UNIT <br />AIC AMPERE INTERRUPTING CAPACITY <br />AL ALUMINUM <br />ALD ASSISTED LISTENING DEVICE <br />ALT ALTERNATE <br />ARCH ARCHITECTURAL <br />AS AMP SWITCH <br />AT AMP TRIP <br />A I S AUTOMAT IC TRANSFER SWITCH <br />AUTO AUTOMATIC <br />AV AUDIO VISUAL <br />AVG AVERAGE <br />AWG AMERICAN WIRE GAUGE <br />BC BONDING CONDUCTOR <br />BCU BARE COPPER <br />BFC BELOW FINISHED CEILING <br />BFG BELOW FINISHED GRADE <br />BKR BREAKER <br />BLDG BUILDING <br />BOF BOTTOM OF FIXTURE <br />BOH BACK OF HOUSE <br />BTM BOTTOM <br />C CONDUIT <br />C/W COMPLETE WITH <br />CAP CAPACITY <br />CATV COMMUNITY ANTENNA TELEVISION <br />CB CIRCUIT BREAKER <br />CCTV CLOSED CIRCUIT TELEVISION <br />CEC CANADIAN ELECTRIC CODE <br />CFOI CONTRACTOR FURNISHED, OWNER <br />INSTALLED <br />CIRC CIRCULATING <br />CKT CIRCUIT <br />CL CENTERLINE <br />CLG CEILING <br />CM CEILING MOUNTED <br />CMU CONCRETE MASONRY UNIT <br />CO CONDUIT ONLY <br />COMM COMMUNICATIONS <br />CONC CONCRETE <br />CONN CONNECTION <br />CONST CONSTRUCTION <br />CONT CONTINUOUS <br />CONTR CONTRACTOR <br />CPT CONTROL POWER TRANSFORMER <br />CPU CENTRAL PROCESSING UNIT <br />CR CRITICAL BRANCH <br />CT CURRENT TRANSFORMERS <br />CTR CENTER <br />CU COPPER <br />CUH CABINET UNIT HEATER <br />D DEDICATED <br />DALI DIGITAL ADDRESSABLE LIGHTING <br />INTERFACE <br />DC DIRECT CURRENT <br />DET DETAIL <br />DIA DIAMETER <br />DIM DIMENSION <br />DISC DISCONNECT <br />DIV DIVISION <br />DL DAMP LOCATION <br />DMX DIGITAL MULTIPLEX <br />DMX-RDM DIGITAL MULTIPLEX REMOTE <br />DEVICE MANAGEMENT <br />DN DOWN <br />DP DISTRIBUTION PANEL <br />DPDT DOUBLE POLE, DOUBLE THROW <br />DPR DAMPER <br />DPST DOUBLE POLE, SINGLE THROW <br />DWG DRAWING <br />DWH DOMESTIC WATER HEATER <br />EA EACH <br />EC ELECTRICAL CONTRACTOR <br />EF EXHAUSTFAN <br />ELEC ELECTRICAL <br />ELEV ELEVATOR <br />EM EMERGENCY <br />EM GEN EMERGENCY GENERATOR <br />EMT ELECTRICAL METALLIC TUBING <br />ENCL ENCLOSURE <br />EP ELECTRIC -PNEUMATIC <br />EPO EMERGENCY POWER OFF <br />EQ EQUIPMENT BRANCH <br />EQUIP EQUIPMENT <br />ETD EMERGENCY TRANSFER DEVICE <br />EWC ELECTRIC WATER COOLER <br />EXH EXHAUST <br />EXP EXPLOSION PROOF <br />EXTER EXTERIOR <br />F&I FURNISHED AND INSTALLED <br />FA FIRE ALARM <br />FAA FIRE ALARM ANNUNCIATOR <br />FACP FIRE ALARM CONTROL PANEL <br />FB FLOOR BOX <br />FCU FAN COIL UNIT <br />FLR FLOOR <br />FLUOR FLUORESCENT <br />FO FIBER (FIBRE) OPTIC <br />FOH FRONT OF HOUSE <br />FP FIRE PROTECTION <br />FPC FORWARD PHASE CONTROL <br />FS FUSIBLE SWITCH <br />FSCS FIRE FIGHTER SMOKE CONTROL <br />STATION <br />FU FUSE <br />FVNR FULL VOLTAGE NON REVERSING <br />FVR FULL VOLTAGE REVERSING <br />G,GND GROUND <br />G/Y GREEN YELLOW <br />GA GAUGE <br />GAL GALLONS <br />GC GENERAL CONTRACTOR <br />GEN GENERATOR <br />GFI, GFCI GROUND FAULT (CIRCUIT) <br />INTERRUPTER <br />H HOT CONDUCTOR <br />HC HORIZONTAL CROSS CONNECT <br />HD HAND DRYER <br />HFF HANDS FREE FIXTURE <br />HH HANDHOLE <br />HID HIGH INTENSITY DISCHARGE <br />HK HOUSE KEEPING PAD <br />HM HORIZONTALLY MOUNTED <br />HOA HAND -OFF -AUTO <br />HOR HORIZONTAL <br />HP HORSEPOWER <br />HT HEIGHT <br />HTG HEATING <br />HV HIGH VOLTAGE <br />HVCB HIGH VOLTAGE CIRCUIT BREAKER <br />HW HOT WATER <br />HZ HERTZ <br />IC INTERMEDIATE CROSS CONNECT <br />ID INSIDE DIAMETER <br />IDF INTERMEDIATE DISTRIBUTION <br />FRAME <br />IG ISOLATED GROUND <br />IMC INTERMEDIATE METAL CONDUIT <br />INST INSTANTANEOUS <br />IF INTERNET PROTOCOL <br />JB JUNCTION BOX <br />K KIRK KEY INTERLOCK <br />KAIC KILO -AMPS INTERRUPTING <br />CAPACITY <br />KV KILOVOLT <br />KVA KILOVOLT -AMPERES <br />KW KILOWATT <br />LED LIGHT EMITTING DIODE <br />LR LEGALLY REQUIRED <br />LS LIFE SAFETY BRANCH <br />LSIG LONG TIME, SHORT TIME, <br />INSTANTANEOUS, GROUND FAULT <br />LTG LIGHTING <br />TV LOW VOLTAGE <br />MAU MAKE UP AIR UNIT <br />MAX MAXIMUM <br />MC METAL CLAD CABLE <br />MCA MINIMUM CIRCUIT AMPS <br />MCB MAIN CIRCUIT BREAKER <br />MCC MOTOR CONTROL CENTER <br />MCCB MOLDED CASE CIRCUIT BREAKER <br />MCP MOTOR CIRCUIT PROTECTOR <br />MCT MAIN CROSS CONNECT <br />MDF MAIN DISTRIBUTION FRAME <br />MDP MAIN DISTRIBUTION PANEL <br />MECH MECHANICAL <br />MET MAIN EARTHING TERMINAL <br />MFR MANUFACTURER <br />MH MANHOLE <br />MIN MINIMUM <br />MISC MISCELLANEOUS <br />MLO MAIN LUG ONLY <br />MM MULTIMODE FIBER (FIBRE) OPTIC <br />STRAND <br />MSB MAIN SWITCHBOARD <br />MTD MOUNTED <br />MTG MOUNTING <br />MTS MAIN TERMINAL SPACE <br />MV MEDIUM VOLTAGE <br />MVCB MEDIUM VOLTAGE CIRCUIT <br />BREAKER <br />MW MICROWAVE OVEN <br />N NEUTRAL <br />NAC NOTIFICATION APPLIANCE CIRCUIT <br />NC NORMALLY CLOSED <br />NEC NATIONAL ELECTRIC CODE <br />NEMA NATIONAL ELECTRICAL <br />MANUFACTURERS ASSOCIATION <br />NIC NOT IN CONTRACT <br />NL NIGHT LIGHT <br />NO NORMALLY OPEN <br />NTS NOT TO SCALE <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />OFCI OWNER FURNISHED, CONTRACTOR <br />INSTALLED <br />OFE OWNER FURNISHED EQUIPMENT <br />OH OVERHEAD <br />OL OVERLOAD <br />OS OCCUPANCY SENSOR, OPTIONAL <br />STANDBY <br />OSP OUTSIDE PLANT <br />P POLE <br />PA PUBLIC ADDRESS <br />PB PULL BOX <br />PD PUNCHDOWN <br />PF POWER FACTOR <br />PNL PANEL <br />POE POINT OF ENTRANCE <br />POS POINT OF SERVICE <br />PR PAIR <br />PT POTENTIAL TRANSFORMERS <br />PTS PNEUMATIC TUBE STATION <br />PTZ PAN/TILT/ZOOM <br />PV PHOTOVOLTAIC <br />PVC POLYVINYL CHLORIDE <br />PWR POWER <br />RA RETURN AIR <br />REC RECESSED <br />RECP RECEPTACLE <br />REQD REQUIRED <br />REX REQUEST TO EXIT <br />RM ROOM <br />RNC RIGID NON-METALLIC CONDUIT <br />RO RACEWAY ONLY <br />RPC REVERSE PHASE CUT <br />RSC, RGS RIGID STEEL CONDUIT <br />SCCR SHORT CIRCUIT CURRENT RATING <br />SEC SECURITY <br />SECT SECTION <br />SIM SIMILAR <br />SM SINGLE MODE FIBER OPTIC STRAND <br />SMR SURFACE MOUNTED RACEWAY <br />SPD SURGE PROTECTED DEVICE <br />SPDT SINGLE POLE DOUBLE THROW <br />SPECS SPECIFICATIONS <br />SPST SINGLE POLE SINGLE THROW <br />8S STAINLESS STEEL <br />ST SHUNT TRIP <br />STD STANDARD <br />SW SWITCH <br />SWBD SWITCHBOARD <br />SWGR SWITCHGEAR <br />SYS SYSTEM <br />TBB TELECOMMUNICATIONS BACKBONE <br />TC TEMPERATURE CONTROL OR <br />TERMINAL CABINET <br />TE TELECOMMUNICATIONS <br />ENCLOSURE <br />TELE TELEPHONE <br />TELECOM TELECOMMUNICATIONS <br />TEMP TEMPERATURE <br />TERM TERMINAL <br />TGB TELECOMMUNICATIONS GROUND <br />BAR <br />TMGB TELECOMMUNICATIONS MAIN <br />GROUNDBAR <br />TOF TOP OF FIXTURE <br />TP TAMPER RESISTANT <br />TR TELECOMMUNICATIONS ROOM <br />TSP TWISTED SHIELDED PAIR <br />TSTAT THERMOSTAT <br />TTB TELECOM TERMINAL BOARD <br />TV TELEVISION <br />TYP TYPICAL <br />UG UNDERGROUND <br />UH UNIT HEATER <br />UNO UNLESS NOTED OTHERWISE <br />UNV UNIVERSAL VOLTAGE <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />USB UNIVERSAL SERIAL BUS <br />UTP UNSHIELDED TWISTED PAIR <br />UV UNIT VENTILATOR <br />V VOLTS <br />VA VOLT -AMPS <br />VAV VARIABLE AIR VOLUME <br />VC VOLUME CONTROL <br />VDT VISUAL DISPLAY TERMINAL <br />VERT VERTICAL <br />VFD VARIABLE FREQUENCY DRIVE <br />VIE VERIFY IN FIELD <br />VOL VOLUME <br />VT VAPOR TIGHT <br />W WIRE, WATT <br />WAP WIRELESS ACCESS POINT <br />WG WIREGUARD <br />WL WET LOCATION <br />WP WEATHERPROOF <br />WT WATERTIGHT <br />XFMR TRANSFORMER <br />O,PH PHASE <br />PROJECT NOTES <br />1. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS <br />FROM AUTHORITIES HAVING JURISDICTION AND PAY ALL ASSOCIATED FEES. <br />2. LOCATE JUNCTION AND PULL BOXES AS REQUIRED TO ALLOW ACCESS AFTER <br />EQUIPMENT AND APPURTENANCES ARE INSTALLED. COORDINATE EXACT <br />LOCATIONS WITH THE OTHER TRADES. COORDINATE LOCATIONS AND <br />ELEVATIONS OF ELECTRICAL DEVICES WITH DRAWINGS AND OTHER TRADES <br />PRIOR TO INSTALLATION. <br />3. PROTECT PERMANENT BUILDING FINISHES FROM DAMAGE DURING <br />CONSTRUCTION PERIOD. PROVIDE PLYWOOD OR SIMILAR MATERIAL UNDER <br />EQUIPMENT OR MATERIALS STORED ON FLOORS, AND IN AREAS WHERE <br />CONSTRUCTION MAY DAMAGE FINISHES. SURFACES OR FINISHES DAMAGED <br />DURING CONSTRUCTION SHALL BE REPLACED AT THE COST OF THE <br />CONTRACTOR AT FAULT. <br />4. CONTRACTORS SHALL COORDINATE LOCATIONS OF FIXTURES AND <br />ELECTRICAL DEVICES INSTALLED IN OR ON THE CEILING WITH <br />ARCHITECTURAL REFLECTED CEILING PLAN. CEILING MOUNTED ELECTRICAL <br />DEVICES SHALL BE MOUNTED IN THE CENTER OF THE CEILING TILES, UNLESS <br />OTHERWISE NOTED, <br />5. WHERE DIRECTED TO USE OR RETAIN EXISTING CIRCUITS, AND THE CIRCUIT <br />NUMBERS DIFFER FROM THE DRAWING, UPDATE DIRECTORIES AND RECORD <br />DRAWINGS. <br />6. PROPERLY SUPPORT PER CODE LOW VOLTAGE CABLING NOT IN CONDUIT. IN <br />AREAS SUCH AS CORRIDORS DESIGNATED FOR NEW CEILINGS AND FINISHES, <br />SUPPORT EXISTING ELECTRICAL DEVICES AND EQUIPMENT IN AND ABOVE <br />THE CEILING, INCLUDING CONDUIT AND CABLING. PROVIDE PROPER <br />PERMANENT SUPPORT AS NEEDED TO COMPLY WITH CODE AND TAKE <br />WEIGHT OFF CEILING SUPPORTS. REMOVE AND REINSTALL ELECTRICAL <br />DEVICES AND EQUIPMENT AS NEEDED FOR PAINTING, WALL COVERINGS, <br />CEILINGS, AND FINISH WORK, REFER TO ARCHITECTURAL DRAWINGS, LOW <br />VOLTAGE CABLING LOCATED IN EXPOSED STRUCTURE (CEILING) AREAS <br />SHALL BE INSTALLED IN CONDUIT (OR CABLE TRAY, IF APPLICABLE) AND <br />ROUTED TIGHT TO DECK. INSTALLATIONS NOT IN COMPLIANCE WITH THIS <br />REQUIREMENT SHALL BE REMOVED AND REINSTALLED AT CONTRACTOR'S <br />EXPENSE, <br />7. WHERE PROJECT PHASING IS INDICATED IN ANY PART OF THE WORKING <br />DOCUMENT PACKAGE, ELECTRICAL CONTRACTOR IS TO PLAN WORK SO AS <br />TO FACILITATE SUCH PHASING. <br />8. FOR BRANCH CIRCUITS OVER 75' (25 METERS) IN LENGTH (TOTAL ONE WAY) <br />FROM THE PANEL, THE ELECTRICAL CONTRACTOR SHALL CALCULATE THE <br />VOLTAGE DROP AND PROVIDE AN APPROPRIATE CONDUCTOR SIZE TO <br />ACHIEVE NO MORE THAN 3% MAXIMUM ALLOWABLE VOLTAGE DROP, <br />9. DO NOT SCALE THE DRAWINGS. BECAUSE OF THE SCALE OF THE DRAWINGS, <br />IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS OR OTHER SIMILAR <br />ITEMS WHICH MAY BE REQUIRED TO MAKE A COMPLETE OPERATING SYSTEM. <br />CAREFULLY INVESTIGATE CONDITIONS AFFECTING WORK AND INSTALL WORK <br />IN SUCH MANNER THAT INTERFERENCES BETWEEN PIPES, CONDUITS, DUCTS, <br />EQUIPMENT, ARCHITECTURAL AND STRUCTURAL FEATURES SHALL BE <br />AVOIDED. <br />1. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE, AND WHICH <br />IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT, SHALL BE <br />REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME <br />THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF <br />WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST <br />IF NOT SHOWN TO BE RELOCATED IF SUCH WIRING IS FOUND THE <br />CONTRACTOR SHALL NOTIFY THE OWNER OF WIRING LOCATION, REASON IT <br />MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S <br />APPROVAL BEFORE PROCEEDING WITH THE WORK, <br />PRIOR TO COMMENCING WITH DEMOLITION, IDENTIFY ALL POWER, LIGHTING, <br />COMMUNICATION, AND SIGNAL CIRCUITS PASSING THROUGH THE <br />DEMOLITION AREA OR EXTENDING BEYOND THE DEMOLITION AREA. <br />COORDINATE WITH DEMOLITION WORK OF OTHER TRADES. <br />2. THE EXISTING BUILDING MUST BE KEPT IN OPERATION AT ALL TIMES. <br />MAINTAIN ELECTRICAL SERVICES AND SYSTEMS AT ALL TIMES TO AREAS <br />BEYOND THE CONSTRUCTION AREA AND MAINTAIN CONTINUITY OF FIRE <br />ALARM, LIFE SAFETY AND SECURITY SYSTEMS TO ALL OCCUPIED AREAS OF <br />THE BUILDING THROUGHOUT THE CONSTRUCTION PERIOD. PROVIDE <br />TEMPORARY WIRING AND BRANCH CIRCUITING AS NECESSARY TO MAINTAIN <br />OPERATION OF EXISTING CIRCUITS AND SYSTEMS EXTENDING BEYOND <br />REMODEL AREA, ASSUME FULL RESPONSIBILITY FOR ANY DISRUPTION TO <br />EXISTING SERVICES, RECONNECT ANY SERVICES WHICH ARE TO REMAIN, <br />AND WHICH HAVE BEEN DISCONNECTED DURING DEMOLITION OR <br />CONSTRUCTION. ARRANGE WORK IN SUCH A MANNER THAT INTERRUPTIONS <br />IN SERVICES OCCUR ONLY AT PRE -SCHEDULED TIMES. CARRY OUT THE <br />WORK WITH A MINIMUM OF NOISE, DUST AND DISTURBANCE. <br />3. PERMANENTLY REMOVE ABANDONED ELECTRICAL EQUIPMENT, LIGHTING <br />FIXTURES, ELECTRICAL DEVICES, POWER AND SIGNALLING WIRING DEVICES <br />AND ASSOCIATED WIRE, RACEWAYS, AND/OR JUNCTION BOXES, THE <br />REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT <br />PRESENTLY CONCEALED IN EXISTING CONSTRUCTION SHALL BE <br />COORDINATED WITH THE OWNER PRIOR TO REMOVAL OR RELOCATION, <br />RACEWAYS AND CONDUCTORS SHALL BE REMOVED BACK TO THE SOURCE <br />OR NEAREST REMAINING JUNCTION BOX OR DEVICE AS FAR AS PRACTICAL, <br />OR WHERE COMPLETE REMOVAL NOT PRACTICAL, RENDERED PERMANENTLY <br />SAFE. <br />4. ANY EXISTING SYSTEM OUTAGES SHALL BE OF MINIMUM DURATION AND AT A <br />TIME ACCEPTABLE TO THE OWNER, ARRANGED A MINIMUM OF 10 WORKING <br />DAYS IN ADVANCE. LONGER NOTICES AND/OR ADDITIONAL RESTRICTIONS <br />PERTAINING TO OUTAGES MAY BE REQUIRED IN SOME INSTANCES, AS PER <br />SPECIFICATIONS. VERIFY PROTOCOL WITH ALL PROJECT STAKEHOLDERS <br />INCLUDING OWNER, TENANT, CONSTRUCTION MANAGER AND/OR USER <br />GROUP(S) AS APPLICABLE. <br />5. ELECTRICAL EQUIPMENT, FIXTURES, AND/OR DEVICES SCHEDULED TO <br />REMAIN OR TO BE RELOCATED THAT ARE DAMAGED DURING DEMOLITION <br />SHALL BE REPLACED WITH SIMILAR TYPE AS APPROVED BY THE OWNER, AT <br />NO ADDITIONAL CHARGE TO THE OWNER. <br />6. IN THE EVENT THAT DEMOLITION WORK AFFECTS THE STRUCTURAL <br />SUPPORT OF EXISTING ELECTRICAL EQUIPMENT THAT IS TO REMAIN IN <br />SERVICE, IT SHALL BE RE -SUPPORTED IN ACCORDANCE WITH ALL <br />APPLICABLE CODES. PROVIDE TEMPORARY SUPPORTS WHERE REQUIRED. <br />7, UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED <br />AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED <br />TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES <br />SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT <br />OR REQUIRED FIRE SEALANT, UNUSED RACEWAYS ABOVE ACCESSIBLE <br />CEILINGS SHALL BE REMOVED. <br />8. ELECTRICAL MATERIAL SCHEDULED FOR REMOVAL IS TO BE REMOVED FROM <br />THE SITE AND PROPERLY DISPOSED OF AS PART OF THIS CONTRACT. ANY <br />ELECTRICAL MATERIAL THE OWNER WISHES TO RETAIN TO BECOME THE <br />PROPERTY OF THE OWNER AND TO BE REMOVED AND PLACED AT A <br />LOCATION ON THE SITE AS DIRECTED BY THE OWNER, <br />9. THE DEMOLITION DRAWINGS SHOW THE GENERAL SCOPE OF THE <br />DEMOLITION AND NOT EXACT DETAILS OR TOTAL EXTENT. FOR EXACT <br />DETAILS AND TOTAL EXTENT, EACH SERVICE MUST BE CAREFULLY CHECKED <br />ON SITE. BEFORE REMOVING SERVICES FOLLOW THE SERVICE THROUGH TO <br />ENSURE OTHER AREAS OF THE BUILDING ARE NOT AFFECTED. <br />INDEXDRAWING <br />NO. <br />DRAWING NAIVE <br />E-001 <br />LEGENDS & ABBREVIATIONS <br />E-002 <br />ELECTRICAL SPECIFICATIONS SHEET 1 OF 2 <br />E-003 <br />ELECTRICAL SPECIFICATIONS SHEET 2 OF 2 <br />E-010 <br />POWER RISER DIAGRAM <br />ED-101A <br />LEVEL 1 DEMO POWER PLAN A <br />ED-101B <br />LEVEL 1 DEMO POWER PLAN B <br />ED-301A <br />LEVEL 1 DEMO LIGHTING PLAN A <br />ED-301B <br />LEVEL 1 DEMO LIGHTING PLAN B <br />E-101A <br />LEVEL 1 POWER PLAN A <br />E-101 B <br />LEVEL 1 POWER PLAN B <br />E-201A <br />LEVEL MECH POWER PLAN A <br />E-201B <br />LEVEL MECH POWER PLAN B <br />E-202A <br />ROOF MECH POWER PLAN A <br />E-301A <br />LEVEL 1 LIGHTING PLAN A <br />E-301B <br />LEVEL 1 LIGHTING PLAN B <br />E-401 <br />ELECTRICAL DETAILS <br />E-501 <br />ELECTRICAL SCHEDULES <br />E-502 <br />ELECTRICAL SCHEDULES <br />E-503 <br />ELECTRICAL SCHEDULES <br />E-601 <br />ENERGY CODE COMPLIANCE - LIGHTING <br />FA-101A <br />LEVEL 1 FIRE ALARM PLAN A <br />FA-101B <br />LEVEL 1 FIRE ALARM PLAN B <br />ill <br />c <br />0 <br />.j <br />0 <br />V) <br />LLJ <br />0 <br />0 <br />0 <br />z <br />0 <br />o <br />u 1N <br />Permit/Seal <br />53817 <br />�ssloNAL ��� <br />2021-00-05 <br />Project No.:22705501 <br />I <br />File Name: N/A <br />GN/PE <br />GN/PE PE/MS 03/05/21 <br />Dwn. <br />Dsgn. Chkd. YYYY.MM.DD <br />Title <br />LEGENDS <br />ABBREVIATIONS <br />Drawing No. E,,00,ml <br />ORIGINAL SHEET -ARCH D <br />