11
<br />2
<br />e
<br />V
<br />R
<br />11
<br />I
<br />IQ
<br />0
<br />TELECOM OUTLETS
<br />OUTLET
<br />OUTLET, CEILING MOUNTED
<br />FURNITURE SYSTEMS OUTLET
<br />,
<br />OUTLET, MOUNTED IN FLOOR BOX
<br />OUTLET, MOUNTED IN POKE THRU
<br />('
<br />OUTLET, MOUNTED IN POWER POLE
<br />TELECOM OUTLET TYPES
<br />#
<br /># INDICATES QUANTITY OF DATA JACKS, PULLSTRING
<br />ALWAYS PROVIDED. WHERE NO QUANTITY IS NOTED,
<br />2 DATA JACKS AND PULLSTRING.
<br />AC
<br />MOUNTED 3" ABOVE COUNTER BACKSPLASH
<br />B
<br />BLANK FACEPLATE, ROUGH -IN ONLY
<br />'p D
<br />DIRECT CONNECTION TO PANEL
<br />M
<br />PATIENT MONITORING
<br />P
<br />PAY TELEPHONE
<br />y R
<br />RACEWAY MOUNTED
<br />\27 W
<br />WALL. MOUNTED TELEPHONE HANDSET OUTLET
<br />gp WAP
<br />WIRELESS ACCESS POINT CONNECTION
<br />CIRCUITS
<br />RECEPTACLES
<br />EMERGENCY
<br />NORMAL
<br />SINGLE RECEPTACLE, 120V
<br />SINGLE RECEPTACLE, 120V, CEILING MOUNTED
<br />DUPLEX RECEPTACLE, 120V
<br />DUPLEX RECEPTACLE, 120V, CEILING MOUNTED
<br />DOUBLE DUPLEX RECEPTACLE, 120V
<br />DOUBLE DUPLEX RECEPTACLE, 120V, CEILING
<br />MOUNTED
<br />SPLIT WIRED RECEPTACLE, 120V, TOP CONTROLLED,
<br />BOTTOM CONSTANTLY ENERGIZED
<br />#
<br />#
<br />RECEPTACLE, NEMA #
<br />#
<br />#
<br />RECEPTACLE, NEMA #, CEILING MOUNTED
<br />#
<br />#
<br />COMBINATION RECEPTACLE, NEMA # AND 120V
<br />FURNITURE SYSTEMS RECEPTACLE, 120V
<br />N/A
<br />��
<br />[LEI, -1
<br />INDICATES FULLY CONTROLLED
<br />N/A
<br />! T
<br />INDICATES 15A
<br />N/A
<br />(I
<br />INDICATES TWIST LOCK
<br />NIA
<br />L)
<br />:; I
<br />INDICATES MOUNTED 3" (75 MM) ABOVE COUNTER
<br />.�
<br />BACKSPLASH
<br />N/A
<br />MULTI -SERVICE FLOOR BOX (RECEPTACLES/OUTLETS
<br />AS INDICATED)
<br />N/A
<br />®;.V'
<br />MULTI -SERVICE POKE THRU (RECEPTACLES/OUTLETS
<br />AS INDICATED)
<br />N/A
<br />`
<br />MULTI -SERVICE POWER POLE
<br />(RECEPTACLES/OUTLETS AS INDICATED)
<br />N/A
<br />0
<br />MULTI -SERVICE ASSEMBLY (RECEPTACLES/OUTLETS
<br />AS INDICATED)
<br />N/A
<br />CLOCK RECEPTACLE, 120V
<br />CORD DROP, 120V
<br />CEILING CORD DROP, 120V
<br />RECEPTACLE TYPES
<br />9, A
<br />ARC FAULT CIRCUIT INTERRUPTER
<br />AT
<br />ARC FAULT CIRCUIT INTERRUPTER AND TAMPER
<br />RESISTANT
<br />D
<br />DEDICATED CIRCUIT
<br />G
<br />GROUND FAULT CIRCUIT INTERRUPTER
<br />GT
<br />GROUND FAULT CIRCUIT INTERRUPTER AND TAMPER
<br />RESISTANT
<br />I
<br />ISOLATED GROUND
<br />S
<br />SURGE PROTECTOR
<br />T
<br />TAMPER RESISTANT
<br />U
<br />INTEGRAL USB PORT(S)
<br />WP
<br />WEATHER RESISTANT COVER
<br />CONTROLS
<br />®'
<br />NON -FUSED SAFETY SWITCH
<br />FUSED SAFETY SWITCH, FUSE RATING INDICATED
<br />COMBINATION MOTOR STARTER AND FUSED SAFETY
<br />SWITCH, FUSE RATING INDICATED
<br />MOTOR STARTER
<br />MANUAL MOTOR STARTER
<br />AUTOMATIC DOOR PUSHPLATE
<br />DEAD FRONT GFCI
<br />EMERGENCY SHUTDOWN
<br />ENCLOSED CIRCUIT BREAKER
<br />®
<br />ENCLOSED CONTACTOR
<br />PUSH BUTTON CONTROL STATION
<br />,IM
<br />TOGGLE SWITCH, MOTOR RATED
<br />TOUCHLESS AUTOMATIC DOOR OPENER
<br />DDC
<br />DIRECT DIGITAL CONTROL PANEL
<br />R
<br />RELAY
<br />e
<br />THERMOSTAT
<br />TC
<br />TIME CLOCK
<br />VFD
<br />VARIABLE FREQUENCY DRIVE
<br />ELECTRICAL EQUIPMENT
<br />208V OR 240V POWER PANELBOARD
<br />480V OR 600V POWER PANELBOARD
<br />EQUIPMENT CABINET OR PANEL
<br />EQUIPMENT CONNECTION, FILL INDICATES
<br />EMERGENCY CIRCUIT
<br />`—'
<br />GROUND BAR
<br />MOTOR CONNECTION, 10
<br />MOTOR CONNECTION, 30
<br />BUS DUCT
<br />ATS
<br />AUTOMATIC TRANSFER SWITCH
<br />BUS DUCT PLUG
<br />SPD
<br />SURGE PROTECTIVE DEVICE
<br />®
<br />TRANSFORMER, NOT TO SCALE
<br />�r
<br />TRANSFORMER, DRAWN TO SCALE
<br />LIGHTING
<br />SINGLE POLE SWITCH
<br />INDICATES WIRELESS CONTROL
<br />INDICATES BATTERY POWER
<br />a
<br />LOWER-CASE LETTER(S) NEAR SWITCH DENOTE
<br />SWITCH LEG(S)
<br />v 2
<br />DOUBLE POLE SWITCH
<br />a 3
<br />THREE-WAY SWITCH
<br />4
<br />FOUR. -WAY SWITCH
<br />D
<br />DIMMER SWITCH
<br />`` K
<br />KEY OPERATED SWITCH
<br />$ LV
<br />MOMENTARY CONTACT LOW VOLTAGE SWITCH
<br />1 0
<br />�s
<br />OCCUPANCY SENSOR SWITCH
<br />P
<br />SWITCH WITH PILOT LIGHT
<br />PC
<br />PHOTOCELL SWITCH
<br />T
<br />TIMER SWITCH
<br />® COMBINATIONS OF THE ABOVE DESIGNATIONS
<br />MAY BE USED
<br />CS #
<br />LOW VOLTAGE AGE CONTROL STATION, # INDICATES
<br />DSC
<br />STATION IDENTIFICATION
<br />DIMMING SYSTEM CONTROL PANEL
<br />ELCU
<br />�-J
<br />EMERGENCY LIGHTING CONTROL UNIT
<br />LCP
<br />LIGHTING CONTROL PANEL
<br />®P
<br />COMBINATION OCCUPANCY/PHOTO SENSOR SWITCH,
<br />CEILING MOUNTED
<br />OS
<br />OCCUPANCY SENSOR SWITCH, CEILING MOUNTED
<br />PC
<br />PARTITION SENSOR CONTROL
<br />PS
<br />PHOTO SENSOR CONTROL
<br />PS
<br />PHOTO SENSOR CONTROL, CEILING MOUNTED
<br />R
<br />RELAY
<br />®
<br />LOW VOLTAGE TRANSFORMER
<br />FIRE ALARM
<br />FIRE SERVICE PHONE STATION OUTLET
<br />FLAME DETECTOR
<br />CO
<br />GAS DETECTOR, CARBON MONOXIDE
<br />®
<br />HORN AND STROBE LIGHT, CEILING MOUNTED
<br />HORN AND STROBE LIGHT, WALL MOUNTED
<br />®,
<br />REMOTE INDICATOR, CEILING MOUNTED
<br />®�
<br />REMOTE INDICATOR, WALL MOUNTED
<br />SPEAKER AND STROBE LIGHT, CEILING MOUNTED
<br />E14
<br />SPEAKER AND STROBE LIGHT; WALL MOUNTED
<br />.�a
<br />STROBE LIGHT, CEILING MOUNTED
<br />sQ®
<br />STROBE LIGHT, WALL MOUNTED
<br />AIM
<br />ADDRESSABLE INPUT MODULE
<br />ARCM
<br />AREA OF REFUGE COMMUNICATION MASTER UNIT
<br />ARCR
<br />AREA OF REFUGE COMMUNICATION REMOTE UNIT
<br />0
<br />ADDRESSABLE OUTPUT MODULE
<br />®
<br />ELECTRICALLY OPERATED SMOKE OR FIRE/SMOKE
<br />LpCLj
<br />DAMPER CONNECTION
<br />DOOR CLOSER
<br />DH
<br />DOOR HOLDER
<br />IDD
<br />CHIME, WALL MOUNTED
<br />�
<br />HORN, CEILING MOUNTED
<br />D
<br />HORN, WALL MOUNTED
<br />PULL STATION
<br />FAA
<br />FIRE ALARM ANNUNCIATOR
<br />FACP
<br />FIRE ALARM CONTROL PANEL
<br />FAT
<br />FIRE ALARM TRANSMITTER
<br />FATC
<br />FIRE ALARM TERMINAL CABINET
<br />GAP
<br />GRAPHIC ANNUNCIATOR PANEL
<br />H
<br />HEAT DETECTOR
<br />NAC
<br />FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT PANEL
<br />PS
<br />PRESSURE DETECTOR/SWITCH
<br />R
<br />INTERFACE RELAY
<br />S
<br />SMOKE DETECTOR, CEILING MOUNTED
<br />�
<br />SMOKE DETECTOR, WALL MOUNTED
<br />SS
<br />SMOKE DETECTOR, SINGLE STATION
<br />S H
<br />SMOKE/HEAT DETECTOR
<br />WSMOKE/HEAT/CARBON
<br />O
<br />MONOXIDE DETECTOR
<br />SPEAKER, CEILING MOUNTED
<br />SPEAKER; WALL MOUNTED
<br />VS
<br />VALVE SUPERVISORY TAMPER SWITCH
<br />FLOW DETECTOR/SWITCH
<br />HEATISMOKE
<br />TYPES
<br />IBC#/F#
<br />FIXED TEMPERATURE, # INDICATES °C OR OF
<br />EH 1
<br />'._. R
<br />RATE OF RISE
<br />CORC#/F#COMBINED RATE OF RISE/FIXED TEMPERATURE
<br />�S/AS
<br />AIR SAMPLING
<br />0BR
<br />BEAM DETECTOR RECEIVER
<br />BT
<br />BEAMDETECTOR TRANSMITTER
<br />S E
<br />ELEVATOR RECALL
<br />SI
<br />IONIZATION
<br />CIS>1D
<br />IN DUCT
<br />p
<br />PHOTOELECTRIC
<br />CIRCUITS
<br />LUMINAIRES
<br />EMERGENCY
<br />NORMAL
<br />N/A
<br />L01
<br />LUMINAIRE IDENTIFICATION, SEE LUMINAIRES
<br />SCHEDULE
<br />NIA
<br />L;f a
<br />LOWER-CASE LETTER(S) NEAR LUMINAIRE DENOTE
<br />SWITCH LEG(S)
<br />RECESSED RECTANGULAR LUMINAIRE, DRAWN TO
<br />SCALE
<br />SURFACE MOUNTED RECTANGULAR LUMINAIRE,
<br />DRAWN TO SCALE
<br />RECESSED VOLUMETRIC LUMINAIRE, DRAWN TO
<br />SCALE
<br />STRIP LUMINAIRE, LENGTH TO SCALE
<br />WALL MOUNTED RECTANGULAR LUMINAIRE, LENGTH
<br />TO SCALE (NUMBER OF MOUNTING POINTS WILL VARY
<br />WITH THE LUMINAIRE LENGTH AND ARE NOT
<br />INDICATED.)
<br />®
<br />1300
<br />RECESSED DOWNLIGHT LUMINAIRE
<br />SURFACE MOUNTED CEILING LUMINAIRE
<br />PENDANT MOUNTED LUMINAIRE
<br />LINEAR PENDANT MOUNTED LUMINAIRE, LENGTH TO
<br />SCALE (NUMBER OF MOUNTING POINTS WILT® VARY
<br />M
<br />WITH THE LUMINAIRE LENGTH AND ARE NOT
<br />INDICATED.)
<br />WALL MOUNTED LUMINAIRE
<br />WALL MOUNTED VERTICALLY ORIENTED LUMINAIRE
<br />®
<br />WALL MOUNTED RECESSED LINEAR LUMINAIRE,
<br />LENGTH TO SCALE
<br />EXIT SIGN, FILLED SIDES INDICATE ILLUMINATED
<br />N/A
<br />ANNOTATION, ARROWS INDICATE DIRECTIONAL
<br />GRAPHICS
<br />WALL MOUNTED EXIT SIGN, FILLED SIDES INDICATE
<br />N/A
<br />ILLUMINATED ANNOTATION, ARROWS INDICATE
<br />DIRECTIONAL GRAPHICS
<br />N/A
<br />EXIT SIGN WITH EMERGENCY BATTERY PACK
<br />N/A
<br />WALL MOUNTED EXIT SIGN WITH EMERGENCY
<br />BATTERY PACK
<br />N/A
<br />EMERGENCY BATTERY PACK, NUMBER OF LAMPS NOT
<br />INDICATED
<br />tt
<br />N/A
<br />WALL MOUNTED EMERGENCY BATTERY PACK,
<br />NUMBER OF LAMPS NOT INDICATED
<br />KA
<br />N/A
<br />EMERGENCY WITH REMOTE BATTERY PACK, NUMBER
<br />OF LAMPS NOT INDICATED
<br />it
<br />N/A
<br />WALL MOUNTED EMERGENCY WITH REMOTE BATTERY
<br />PACK, NUMBER OF LAMPS NOT INDICATED
<br />Mt
<br />RECESSED LINEAR WALL WASH LUMINAIRE, LENGTH
<br />TO SCALE
<br />LINEAR PENDANT MOUNTED WALL WASH LUMINAIRE,
<br />LENGTH TO SCALE
<br />RECESSED WALL WASH LUMINAIRE
<br />SURFACE MOUNTED WALL WASH LUMINAIRE
<br />PENDANT MOUNTED WALL WASH LUMINAIRE
<br />RECESSED ACCENT LUMINAIRE
<br />SURFACE MOUNTED ACCENT LUMINAIRE
<br />PENDANT MOUNTED ACCENT LUMINAIRE
<br />'y
<br />v
<br />MONOPOINT LUMINAIRE
<br />N/A
<br />TRACK LIGHTING
<br />N/A
<br />CONTINUOUS SOURCE LUMINAIRE, PATH AS
<br />INDICATED
<br />MULTI -LAMP ACCENT LUMINAIRE, NUMBER OF LAMPS
<br />NOT INDICATED
<br />WALL MOUNTED MULTI -LAMP ACCENT LUMINAIRE,
<br />NUMBER OF LAMPS NOT INDICATED
<br />EF
<br />OVERCOUNTER TASK LUMINAIRE
<br />®
<br />cep
<br />UNDERCABINET TASK LUMINAIRE
<br />FIBER OPTIC REMOTE SOURCE
<br />rl
<br />STEP LUMINAIRE
<br />I
<br />ILLUMINATED SIGN
<br />®
<br />WALL MOUNTED ILLUMINATED SIGN
<br />NIGHT LIGHT
<br />WALL MOUNTED STROBE LIGHT
<br />WORK DEFINITION
<br />NEW WORK
<br />EXISTING
<br />o® m®
<br />REMOVE EXISTING
<br />REMOVE EXISTING ELECTRICAL EQUIPMENT
<br />— — —
<br />FUTURE
<br />e = e ®
<br />TEMPORARY, AS NOTED
<br />?:##
<br />KEY NOTE
<br />???
<br />EQUIPMENT IDENTIFICATION
<br />CIRCUITS
<br />RACEWAY CONCEALED IN CEILING OR WALL. EXPOSED
<br />RACEWAY IS ALLOWED ONLY WHERE NOTED.
<br />--- — —
<br />RACEWAY BELOW SLAB OR UNDERGROUND
<br />�—�
<br />RACEWAY UP
<br />RACEWAY DOWN
<br />RACEWAY CONTINUATION
<br />—71
<br />RACEWAY STUB -OUT WITH BUSHING
<br />9
<br />SURFACE RACEWAY (HORIZONTAL/VERTICAL)
<br />la
<br />PLUG STRIP (HORIZONTAL/VERTICAL)
<br />J
<br />JUNCTION BOX, CEILING OR ABOVE CEILING MOUNTED
<br />JUNCTION BOX, WALL MOUNTED
<br />J
<br />JUNCTION BOX, IN -GROUND
<br />PB
<br />PULL BOX
<br />#1C MULTI -CONDUCTOR, # INDICTA TES
<br />QUANTITY
<br />(D) DEMOLISH
<br />(E) EXISTING
<br />(N) NEW
<br />(R) EXISTING TO BE RELOCATED
<br />1/C SINGLE CONDUCTOR
<br />A AMPS
<br />A/C AIR CONDITIONING UNIT
<br />AC ALTERNATING CURRENT
<br />ACH ABOVE COUNTER HEIGHT
<br />ACT ACOUSTICAL CEILING TILE
<br />ADA AMERICANS WITH DISABILITIES ACT
<br />ADJ ADJUSTABLE
<br />AF AMP FRAME
<br />AFC ABOVE FINISHED CEILING
<br />AFCI ARC FAULT CIRCUIT INTERRUPTER
<br />AFF ABOVE FINISHED FLOOR
<br />AFG ABOVE FINISHED GRADE
<br />AHJ AUTHORITY HAVING JURISDICTION
<br />AHU AIR HANDLING UNIT
<br />AIC AMPERE INTERRUPTING CAPACITY
<br />AL ALUMINUM
<br />ALD ASSISTED LISTENING DEVICE
<br />ALT ALTERNATE
<br />ARCH ARCHITECTURAL
<br />AS AMP SWITCH
<br />AT AMP TRIP
<br />A I S AUTOMAT IC TRANSFER SWITCH
<br />AUTO AUTOMATIC
<br />AV AUDIO VISUAL
<br />AVG AVERAGE
<br />AWG AMERICAN WIRE GAUGE
<br />BC BONDING CONDUCTOR
<br />BCU BARE COPPER
<br />BFC BELOW FINISHED CEILING
<br />BFG BELOW FINISHED GRADE
<br />BKR BREAKER
<br />BLDG BUILDING
<br />BOF BOTTOM OF FIXTURE
<br />BOH BACK OF HOUSE
<br />BTM BOTTOM
<br />C CONDUIT
<br />C/W COMPLETE WITH
<br />CAP CAPACITY
<br />CATV COMMUNITY ANTENNA TELEVISION
<br />CB CIRCUIT BREAKER
<br />CCTV CLOSED CIRCUIT TELEVISION
<br />CEC CANADIAN ELECTRIC CODE
<br />CFOI CONTRACTOR FURNISHED, OWNER
<br />INSTALLED
<br />CIRC CIRCULATING
<br />CKT CIRCUIT
<br />CL CENTERLINE
<br />CLG CEILING
<br />CM CEILING MOUNTED
<br />CMU CONCRETE MASONRY UNIT
<br />CO CONDUIT ONLY
<br />COMM COMMUNICATIONS
<br />CONC CONCRETE
<br />CONN CONNECTION
<br />CONST CONSTRUCTION
<br />CONT CONTINUOUS
<br />CONTR CONTRACTOR
<br />CPT CONTROL POWER TRANSFORMER
<br />CPU CENTRAL PROCESSING UNIT
<br />CR CRITICAL BRANCH
<br />CT CURRENT TRANSFORMERS
<br />CTR CENTER
<br />CU COPPER
<br />CUH CABINET UNIT HEATER
<br />D DEDICATED
<br />DALI DIGITAL ADDRESSABLE LIGHTING
<br />INTERFACE
<br />DC DIRECT CURRENT
<br />DET DETAIL
<br />DIA DIAMETER
<br />DIM DIMENSION
<br />DISC DISCONNECT
<br />DIV DIVISION
<br />DL DAMP LOCATION
<br />DMX DIGITAL MULTIPLEX
<br />DMX-RDM DIGITAL MULTIPLEX REMOTE
<br />DEVICE MANAGEMENT
<br />DN DOWN
<br />DP DISTRIBUTION PANEL
<br />DPDT DOUBLE POLE, DOUBLE THROW
<br />DPR DAMPER
<br />DPST DOUBLE POLE, SINGLE THROW
<br />DWG DRAWING
<br />DWH DOMESTIC WATER HEATER
<br />EA EACH
<br />EC ELECTRICAL CONTRACTOR
<br />EF EXHAUSTFAN
<br />ELEC ELECTRICAL
<br />ELEV ELEVATOR
<br />EM EMERGENCY
<br />EM GEN EMERGENCY GENERATOR
<br />EMT ELECTRICAL METALLIC TUBING
<br />ENCL ENCLOSURE
<br />EP ELECTRIC -PNEUMATIC
<br />EPO EMERGENCY POWER OFF
<br />EQ EQUIPMENT BRANCH
<br />EQUIP EQUIPMENT
<br />ETD EMERGENCY TRANSFER DEVICE
<br />EWC ELECTRIC WATER COOLER
<br />EXH EXHAUST
<br />EXP EXPLOSION PROOF
<br />EXTER EXTERIOR
<br />F&I FURNISHED AND INSTALLED
<br />FA FIRE ALARM
<br />FAA FIRE ALARM ANNUNCIATOR
<br />FACP FIRE ALARM CONTROL PANEL
<br />FB FLOOR BOX
<br />FCU FAN COIL UNIT
<br />FLR FLOOR
<br />FLUOR FLUORESCENT
<br />FO FIBER (FIBRE) OPTIC
<br />FOH FRONT OF HOUSE
<br />FP FIRE PROTECTION
<br />FPC FORWARD PHASE CONTROL
<br />FS FUSIBLE SWITCH
<br />FSCS FIRE FIGHTER SMOKE CONTROL
<br />STATION
<br />FU FUSE
<br />FVNR FULL VOLTAGE NON REVERSING
<br />FVR FULL VOLTAGE REVERSING
<br />G,GND GROUND
<br />G/Y GREEN YELLOW
<br />GA GAUGE
<br />GAL GALLONS
<br />GC GENERAL CONTRACTOR
<br />GEN GENERATOR
<br />GFI, GFCI GROUND FAULT (CIRCUIT)
<br />INTERRUPTER
<br />H HOT CONDUCTOR
<br />HC HORIZONTAL CROSS CONNECT
<br />HD HAND DRYER
<br />HFF HANDS FREE FIXTURE
<br />HH HANDHOLE
<br />HID HIGH INTENSITY DISCHARGE
<br />HK HOUSE KEEPING PAD
<br />HM HORIZONTALLY MOUNTED
<br />HOA HAND -OFF -AUTO
<br />HOR HORIZONTAL
<br />HP HORSEPOWER
<br />HT HEIGHT
<br />HTG HEATING
<br />HV HIGH VOLTAGE
<br />HVCB HIGH VOLTAGE CIRCUIT BREAKER
<br />HW HOT WATER
<br />HZ HERTZ
<br />IC INTERMEDIATE CROSS CONNECT
<br />ID INSIDE DIAMETER
<br />IDF INTERMEDIATE DISTRIBUTION
<br />FRAME
<br />IG ISOLATED GROUND
<br />IMC INTERMEDIATE METAL CONDUIT
<br />INST INSTANTANEOUS
<br />IF INTERNET PROTOCOL
<br />JB JUNCTION BOX
<br />K KIRK KEY INTERLOCK
<br />KAIC KILO -AMPS INTERRUPTING
<br />CAPACITY
<br />KV KILOVOLT
<br />KVA KILOVOLT -AMPERES
<br />KW KILOWATT
<br />LED LIGHT EMITTING DIODE
<br />LR LEGALLY REQUIRED
<br />LS LIFE SAFETY BRANCH
<br />LSIG LONG TIME, SHORT TIME,
<br />INSTANTANEOUS, GROUND FAULT
<br />LTG LIGHTING
<br />TV LOW VOLTAGE
<br />MAU MAKE UP AIR UNIT
<br />MAX MAXIMUM
<br />MC METAL CLAD CABLE
<br />MCA MINIMUM CIRCUIT AMPS
<br />MCB MAIN CIRCUIT BREAKER
<br />MCC MOTOR CONTROL CENTER
<br />MCCB MOLDED CASE CIRCUIT BREAKER
<br />MCP MOTOR CIRCUIT PROTECTOR
<br />MCT MAIN CROSS CONNECT
<br />MDF MAIN DISTRIBUTION FRAME
<br />MDP MAIN DISTRIBUTION PANEL
<br />MECH MECHANICAL
<br />MET MAIN EARTHING TERMINAL
<br />MFR MANUFACTURER
<br />MH MANHOLE
<br />MIN MINIMUM
<br />MISC MISCELLANEOUS
<br />MLO MAIN LUG ONLY
<br />MM MULTIMODE FIBER (FIBRE) OPTIC
<br />STRAND
<br />MSB MAIN SWITCHBOARD
<br />MTD MOUNTED
<br />MTG MOUNTING
<br />MTS MAIN TERMINAL SPACE
<br />MV MEDIUM VOLTAGE
<br />MVCB MEDIUM VOLTAGE CIRCUIT
<br />BREAKER
<br />MW MICROWAVE OVEN
<br />N NEUTRAL
<br />NAC NOTIFICATION APPLIANCE CIRCUIT
<br />NC NORMALLY CLOSED
<br />NEC NATIONAL ELECTRIC CODE
<br />NEMA NATIONAL ELECTRICAL
<br />MANUFACTURERS ASSOCIATION
<br />NIC NOT IN CONTRACT
<br />NL NIGHT LIGHT
<br />NO NORMALLY OPEN
<br />NTS NOT TO SCALE
<br />OC ON CENTER
<br />OD OUTSIDE DIAMETER
<br />OFCI OWNER FURNISHED, CONTRACTOR
<br />INSTALLED
<br />OFE OWNER FURNISHED EQUIPMENT
<br />OH OVERHEAD
<br />OL OVERLOAD
<br />OS OCCUPANCY SENSOR, OPTIONAL
<br />STANDBY
<br />OSP OUTSIDE PLANT
<br />P POLE
<br />PA PUBLIC ADDRESS
<br />PB PULL BOX
<br />PD PUNCHDOWN
<br />PF POWER FACTOR
<br />PNL PANEL
<br />POE POINT OF ENTRANCE
<br />POS POINT OF SERVICE
<br />PR PAIR
<br />PT POTENTIAL TRANSFORMERS
<br />PTS PNEUMATIC TUBE STATION
<br />PTZ PAN/TILT/ZOOM
<br />PV PHOTOVOLTAIC
<br />PVC POLYVINYL CHLORIDE
<br />PWR POWER
<br />RA RETURN AIR
<br />REC RECESSED
<br />RECP RECEPTACLE
<br />REQD REQUIRED
<br />REX REQUEST TO EXIT
<br />RM ROOM
<br />RNC RIGID NON-METALLIC CONDUIT
<br />RO RACEWAY ONLY
<br />RPC REVERSE PHASE CUT
<br />RSC, RGS RIGID STEEL CONDUIT
<br />SCCR SHORT CIRCUIT CURRENT RATING
<br />SEC SECURITY
<br />SECT SECTION
<br />SIM SIMILAR
<br />SM SINGLE MODE FIBER OPTIC STRAND
<br />SMR SURFACE MOUNTED RACEWAY
<br />SPD SURGE PROTECTED DEVICE
<br />SPDT SINGLE POLE DOUBLE THROW
<br />SPECS SPECIFICATIONS
<br />SPST SINGLE POLE SINGLE THROW
<br />8S STAINLESS STEEL
<br />ST SHUNT TRIP
<br />STD STANDARD
<br />SW SWITCH
<br />SWBD SWITCHBOARD
<br />SWGR SWITCHGEAR
<br />SYS SYSTEM
<br />TBB TELECOMMUNICATIONS BACKBONE
<br />TC TEMPERATURE CONTROL OR
<br />TERMINAL CABINET
<br />TE TELECOMMUNICATIONS
<br />ENCLOSURE
<br />TELE TELEPHONE
<br />TELECOM TELECOMMUNICATIONS
<br />TEMP TEMPERATURE
<br />TERM TERMINAL
<br />TGB TELECOMMUNICATIONS GROUND
<br />BAR
<br />TMGB TELECOMMUNICATIONS MAIN
<br />GROUNDBAR
<br />TOF TOP OF FIXTURE
<br />TP TAMPER RESISTANT
<br />TR TELECOMMUNICATIONS ROOM
<br />TSP TWISTED SHIELDED PAIR
<br />TSTAT THERMOSTAT
<br />TTB TELECOM TERMINAL BOARD
<br />TV TELEVISION
<br />TYP TYPICAL
<br />UG UNDERGROUND
<br />UH UNIT HEATER
<br />UNO UNLESS NOTED OTHERWISE
<br />UNV UNIVERSAL VOLTAGE
<br />UPS UNINTERRUPTIBLE POWER SUPPLY
<br />USB UNIVERSAL SERIAL BUS
<br />UTP UNSHIELDED TWISTED PAIR
<br />UV UNIT VENTILATOR
<br />V VOLTS
<br />VA VOLT -AMPS
<br />VAV VARIABLE AIR VOLUME
<br />VC VOLUME CONTROL
<br />VDT VISUAL DISPLAY TERMINAL
<br />VERT VERTICAL
<br />VFD VARIABLE FREQUENCY DRIVE
<br />VIE VERIFY IN FIELD
<br />VOL VOLUME
<br />VT VAPOR TIGHT
<br />W WIRE, WATT
<br />WAP WIRELESS ACCESS POINT
<br />WG WIREGUARD
<br />WL WET LOCATION
<br />WP WEATHERPROOF
<br />WT WATERTIGHT
<br />XFMR TRANSFORMER
<br />O,PH PHASE
<br />PROJECT NOTES
<br />1. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS
<br />FROM AUTHORITIES HAVING JURISDICTION AND PAY ALL ASSOCIATED FEES.
<br />2. LOCATE JUNCTION AND PULL BOXES AS REQUIRED TO ALLOW ACCESS AFTER
<br />EQUIPMENT AND APPURTENANCES ARE INSTALLED. COORDINATE EXACT
<br />LOCATIONS WITH THE OTHER TRADES. COORDINATE LOCATIONS AND
<br />ELEVATIONS OF ELECTRICAL DEVICES WITH DRAWINGS AND OTHER TRADES
<br />PRIOR TO INSTALLATION.
<br />3. PROTECT PERMANENT BUILDING FINISHES FROM DAMAGE DURING
<br />CONSTRUCTION PERIOD. PROVIDE PLYWOOD OR SIMILAR MATERIAL UNDER
<br />EQUIPMENT OR MATERIALS STORED ON FLOORS, AND IN AREAS WHERE
<br />CONSTRUCTION MAY DAMAGE FINISHES. SURFACES OR FINISHES DAMAGED
<br />DURING CONSTRUCTION SHALL BE REPLACED AT THE COST OF THE
<br />CONTRACTOR AT FAULT.
<br />4. CONTRACTORS SHALL COORDINATE LOCATIONS OF FIXTURES AND
<br />ELECTRICAL DEVICES INSTALLED IN OR ON THE CEILING WITH
<br />ARCHITECTURAL REFLECTED CEILING PLAN. CEILING MOUNTED ELECTRICAL
<br />DEVICES SHALL BE MOUNTED IN THE CENTER OF THE CEILING TILES, UNLESS
<br />OTHERWISE NOTED,
<br />5. WHERE DIRECTED TO USE OR RETAIN EXISTING CIRCUITS, AND THE CIRCUIT
<br />NUMBERS DIFFER FROM THE DRAWING, UPDATE DIRECTORIES AND RECORD
<br />DRAWINGS.
<br />6. PROPERLY SUPPORT PER CODE LOW VOLTAGE CABLING NOT IN CONDUIT. IN
<br />AREAS SUCH AS CORRIDORS DESIGNATED FOR NEW CEILINGS AND FINISHES,
<br />SUPPORT EXISTING ELECTRICAL DEVICES AND EQUIPMENT IN AND ABOVE
<br />THE CEILING, INCLUDING CONDUIT AND CABLING. PROVIDE PROPER
<br />PERMANENT SUPPORT AS NEEDED TO COMPLY WITH CODE AND TAKE
<br />WEIGHT OFF CEILING SUPPORTS. REMOVE AND REINSTALL ELECTRICAL
<br />DEVICES AND EQUIPMENT AS NEEDED FOR PAINTING, WALL COVERINGS,
<br />CEILINGS, AND FINISH WORK, REFER TO ARCHITECTURAL DRAWINGS, LOW
<br />VOLTAGE CABLING LOCATED IN EXPOSED STRUCTURE (CEILING) AREAS
<br />SHALL BE INSTALLED IN CONDUIT (OR CABLE TRAY, IF APPLICABLE) AND
<br />ROUTED TIGHT TO DECK. INSTALLATIONS NOT IN COMPLIANCE WITH THIS
<br />REQUIREMENT SHALL BE REMOVED AND REINSTALLED AT CONTRACTOR'S
<br />EXPENSE,
<br />7. WHERE PROJECT PHASING IS INDICATED IN ANY PART OF THE WORKING
<br />DOCUMENT PACKAGE, ELECTRICAL CONTRACTOR IS TO PLAN WORK SO AS
<br />TO FACILITATE SUCH PHASING.
<br />8. FOR BRANCH CIRCUITS OVER 75' (25 METERS) IN LENGTH (TOTAL ONE WAY)
<br />FROM THE PANEL, THE ELECTRICAL CONTRACTOR SHALL CALCULATE THE
<br />VOLTAGE DROP AND PROVIDE AN APPROPRIATE CONDUCTOR SIZE TO
<br />ACHIEVE NO MORE THAN 3% MAXIMUM ALLOWABLE VOLTAGE DROP,
<br />9. DO NOT SCALE THE DRAWINGS. BECAUSE OF THE SCALE OF THE DRAWINGS,
<br />IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS OR OTHER SIMILAR
<br />ITEMS WHICH MAY BE REQUIRED TO MAKE A COMPLETE OPERATING SYSTEM.
<br />CAREFULLY INVESTIGATE CONDITIONS AFFECTING WORK AND INSTALL WORK
<br />IN SUCH MANNER THAT INTERFERENCES BETWEEN PIPES, CONDUITS, DUCTS,
<br />EQUIPMENT, ARCHITECTURAL AND STRUCTURAL FEATURES SHALL BE
<br />AVOIDED.
<br />1. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE, AND WHICH
<br />IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT, SHALL BE
<br />REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME
<br />THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF
<br />WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST
<br />IF NOT SHOWN TO BE RELOCATED IF SUCH WIRING IS FOUND THE
<br />CONTRACTOR SHALL NOTIFY THE OWNER OF WIRING LOCATION, REASON IT
<br />MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S
<br />APPROVAL BEFORE PROCEEDING WITH THE WORK,
<br />PRIOR TO COMMENCING WITH DEMOLITION, IDENTIFY ALL POWER, LIGHTING,
<br />COMMUNICATION, AND SIGNAL CIRCUITS PASSING THROUGH THE
<br />DEMOLITION AREA OR EXTENDING BEYOND THE DEMOLITION AREA.
<br />COORDINATE WITH DEMOLITION WORK OF OTHER TRADES.
<br />2. THE EXISTING BUILDING MUST BE KEPT IN OPERATION AT ALL TIMES.
<br />MAINTAIN ELECTRICAL SERVICES AND SYSTEMS AT ALL TIMES TO AREAS
<br />BEYOND THE CONSTRUCTION AREA AND MAINTAIN CONTINUITY OF FIRE
<br />ALARM, LIFE SAFETY AND SECURITY SYSTEMS TO ALL OCCUPIED AREAS OF
<br />THE BUILDING THROUGHOUT THE CONSTRUCTION PERIOD. PROVIDE
<br />TEMPORARY WIRING AND BRANCH CIRCUITING AS NECESSARY TO MAINTAIN
<br />OPERATION OF EXISTING CIRCUITS AND SYSTEMS EXTENDING BEYOND
<br />REMODEL AREA, ASSUME FULL RESPONSIBILITY FOR ANY DISRUPTION TO
<br />EXISTING SERVICES, RECONNECT ANY SERVICES WHICH ARE TO REMAIN,
<br />AND WHICH HAVE BEEN DISCONNECTED DURING DEMOLITION OR
<br />CONSTRUCTION. ARRANGE WORK IN SUCH A MANNER THAT INTERRUPTIONS
<br />IN SERVICES OCCUR ONLY AT PRE -SCHEDULED TIMES. CARRY OUT THE
<br />WORK WITH A MINIMUM OF NOISE, DUST AND DISTURBANCE.
<br />3. PERMANENTLY REMOVE ABANDONED ELECTRICAL EQUIPMENT, LIGHTING
<br />FIXTURES, ELECTRICAL DEVICES, POWER AND SIGNALLING WIRING DEVICES
<br />AND ASSOCIATED WIRE, RACEWAYS, AND/OR JUNCTION BOXES, THE
<br />REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT
<br />PRESENTLY CONCEALED IN EXISTING CONSTRUCTION SHALL BE
<br />COORDINATED WITH THE OWNER PRIOR TO REMOVAL OR RELOCATION,
<br />RACEWAYS AND CONDUCTORS SHALL BE REMOVED BACK TO THE SOURCE
<br />OR NEAREST REMAINING JUNCTION BOX OR DEVICE AS FAR AS PRACTICAL,
<br />OR WHERE COMPLETE REMOVAL NOT PRACTICAL, RENDERED PERMANENTLY
<br />SAFE.
<br />4. ANY EXISTING SYSTEM OUTAGES SHALL BE OF MINIMUM DURATION AND AT A
<br />TIME ACCEPTABLE TO THE OWNER, ARRANGED A MINIMUM OF 10 WORKING
<br />DAYS IN ADVANCE. LONGER NOTICES AND/OR ADDITIONAL RESTRICTIONS
<br />PERTAINING TO OUTAGES MAY BE REQUIRED IN SOME INSTANCES, AS PER
<br />SPECIFICATIONS. VERIFY PROTOCOL WITH ALL PROJECT STAKEHOLDERS
<br />INCLUDING OWNER, TENANT, CONSTRUCTION MANAGER AND/OR USER
<br />GROUP(S) AS APPLICABLE.
<br />5. ELECTRICAL EQUIPMENT, FIXTURES, AND/OR DEVICES SCHEDULED TO
<br />REMAIN OR TO BE RELOCATED THAT ARE DAMAGED DURING DEMOLITION
<br />SHALL BE REPLACED WITH SIMILAR TYPE AS APPROVED BY THE OWNER, AT
<br />NO ADDITIONAL CHARGE TO THE OWNER.
<br />6. IN THE EVENT THAT DEMOLITION WORK AFFECTS THE STRUCTURAL
<br />SUPPORT OF EXISTING ELECTRICAL EQUIPMENT THAT IS TO REMAIN IN
<br />SERVICE, IT SHALL BE RE -SUPPORTED IN ACCORDANCE WITH ALL
<br />APPLICABLE CODES. PROVIDE TEMPORARY SUPPORTS WHERE REQUIRED.
<br />7, UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED
<br />AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED
<br />TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES
<br />SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT
<br />OR REQUIRED FIRE SEALANT, UNUSED RACEWAYS ABOVE ACCESSIBLE
<br />CEILINGS SHALL BE REMOVED.
<br />8. ELECTRICAL MATERIAL SCHEDULED FOR REMOVAL IS TO BE REMOVED FROM
<br />THE SITE AND PROPERLY DISPOSED OF AS PART OF THIS CONTRACT. ANY
<br />ELECTRICAL MATERIAL THE OWNER WISHES TO RETAIN TO BECOME THE
<br />PROPERTY OF THE OWNER AND TO BE REMOVED AND PLACED AT A
<br />LOCATION ON THE SITE AS DIRECTED BY THE OWNER,
<br />9. THE DEMOLITION DRAWINGS SHOW THE GENERAL SCOPE OF THE
<br />DEMOLITION AND NOT EXACT DETAILS OR TOTAL EXTENT. FOR EXACT
<br />DETAILS AND TOTAL EXTENT, EACH SERVICE MUST BE CAREFULLY CHECKED
<br />ON SITE. BEFORE REMOVING SERVICES FOLLOW THE SERVICE THROUGH TO
<br />ENSURE OTHER AREAS OF THE BUILDING ARE NOT AFFECTED.
<br />INDEXDRAWING
<br />NO.
<br />DRAWING NAIVE
<br />E-001
<br />LEGENDS & ABBREVIATIONS
<br />E-002
<br />ELECTRICAL SPECIFICATIONS SHEET 1 OF 2
<br />E-003
<br />ELECTRICAL SPECIFICATIONS SHEET 2 OF 2
<br />E-010
<br />POWER RISER DIAGRAM
<br />ED-101A
<br />LEVEL 1 DEMO POWER PLAN A
<br />ED-101B
<br />LEVEL 1 DEMO POWER PLAN B
<br />ED-301A
<br />LEVEL 1 DEMO LIGHTING PLAN A
<br />ED-301B
<br />LEVEL 1 DEMO LIGHTING PLAN B
<br />E-101A
<br />LEVEL 1 POWER PLAN A
<br />E-101 B
<br />LEVEL 1 POWER PLAN B
<br />E-201A
<br />LEVEL MECH POWER PLAN A
<br />E-201B
<br />LEVEL MECH POWER PLAN B
<br />E-202A
<br />ROOF MECH POWER PLAN A
<br />E-301A
<br />LEVEL 1 LIGHTING PLAN A
<br />E-301B
<br />LEVEL 1 LIGHTING PLAN B
<br />E-401
<br />ELECTRICAL DETAILS
<br />E-501
<br />ELECTRICAL SCHEDULES
<br />E-502
<br />ELECTRICAL SCHEDULES
<br />E-503
<br />ELECTRICAL SCHEDULES
<br />E-601
<br />ENERGY CODE COMPLIANCE - LIGHTING
<br />FA-101A
<br />LEVEL 1 FIRE ALARM PLAN A
<br />FA-101B
<br />LEVEL 1 FIRE ALARM PLAN B
<br />ill
<br />c
<br />0
<br />.j
<br />0
<br />V)
<br />LLJ
<br />0
<br />0
<br />0
<br />z
<br />0
<br />o
<br />u 1N
<br />Permit/Seal
<br />53817
<br />�ssloNAL ���
<br />2021-00-05
<br />Project No.:22705501
<br />I
<br />File Name: N/A
<br />GN/PE
<br />GN/PE PE/MS 03/05/21
<br />Dwn.
<br />Dsgn. Chkd. YYYY.MM.DD
<br />Title
<br />LEGENDS
<br />ABBREVIATIONS
<br />Drawing No. E,,00,ml
<br />ORIGINAL SHEET -ARCH D
<br />
|