My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1525 75TH ST SW 2021 Plans 2022-12-07
>
Address Records
>
75TH ST SW
>
1525
>
Plans
>
1525 75TH ST SW 2021 Plans 2022-12-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2022 3:39:54 PM
Creation date
7/21/2022 10:33:27 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1525
Permit
B2103-053
Year
2021
Notes
REMODEL OF EXISTING OFFICE SPACE TO DECREASE OVERALL SIZE OF COMCAST OFFICE TO PREP FOR SUBLEASING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. FIRE ALARM DEVICES, INCLUDING QUANTITY, TYPE, CANDELA, AND PLACEMENT, ARE AN ESTIMATE BASED ON THE 2019 NFPA 72. COORDINATE FINAL DEVICE LOCATIONS, QUANTITY, AND <br />REQUIREMENTS WITH FIRE ALARM VENDOR. FIRE ALARM VENDOR TO OBTAIN FIRE ALARM PERMIT. FIRE ALARM VENDOR SHALL PROVIDE DRAWINGS AS NECESSARY TO THE CITY OF <br />EVERETT TO OBTAIN ALL PERMITS AND INSTALL A COMPLETE, FULLY OPERATIONAL BUILDING -WIDE FIRE ALARM SYSTEM FOR THE BUILDING. FIRE ALARM VENDOR TO PROVIDE <br />ENGINEER STAMPED DRAWINGS AS STATE OF WASHINGTON, <br />2. EXISTING FIRE ALARM SYSTEM TO REMAIN, MODIFY AS NECESSARY TO PROVIDE COMPLETE, FULLY OPERATIONAL BUILDING -WIDE FIRE ALARM SYSTEM. VERIFY PROPER OPERATION OF <br />ALL EXISTING FIRE ALARM DEVICES ON THE FLOOR PRIOR TO AND AFTER PROJECT COMPLETION. THE BUILDING FIRE SAFETY DIRECTOR SHALL BE ADVISED OF ANY DEVICE FOUND <br />DAMAGED, DEFECTIVE, OR INOPERATIVE. FIRE ALARM CONTRACTOR TO DETERMINE CONNECTION POINTS TO EXISTING FIRE ALARM SYSTEM. <br />3, EXISTING FIRE ALARM SYSTEM ASSUMED TO BE CODE -COMPLIANT WITH REQUIRED DEVICES INSTALLED. PROVIDE NEW DEVICE IF AREA IS MISSING REQUIRED FIRE ALARM DEVICE. <br />4. PROVIDE SMOKE DETECTOR AT ALL NEW LOCATIONS OF CONTROL UNITS, NOTIFICATION APPLIANCE CIRCUIT POWER EXTENDERS, AND SUPERVISING STATION TRANSMITTING <br />EQUIPMENT PER NFPA 72 §10.4.5. <br />5. ALL NEW WIRING SHALL BE APPROVED FOR FIRE ALARM SYSTEM INSULATION. RUN WIRING CONCEALED IN WALLS FOR CEILINGS. RUN WIRING IN CONDUIT IN EXPOSED AREAS. <br />A, PROVIDE MINIMUM #14AWG COPPER, TEFLON CABLE, 600V, (STROBE LIGHT WIRING). <br />B, PROVIDE MINIMUM #16 AWG COPPER, TWISTED SHIELDED, TEFLON CABLE, 600V, LOOP NOT TO EXCEED 2,000 FEET (ALL OTHER FIRE ALARM DEVICES AND SPEAKER WIRING). <br />6. ALL NEW FIRE ALARM DEVICES AND EQUIPMENT REQUIRED FOR EXISTING MODIFICATION SHALL BE SIMILAR AND COMPLETELY COMPATIBLE WITH EXISTING BUILDING FIRE ALARM <br />SYSTEM. CONTACT BASE BUILDING FIRE ALARM MAINTENANCE COMPANY PRIOR TO ORDERING NEW FIRE ALARM SYSTEM. CONTACT BASE BUILDING FIRE ALARM MAINTENANCE <br />COMPANY PRIOR TO ORDERING NEW FIRE ALARM DEVICES AND CONNECT ALL NEW FIRE ALARM DEVICES AS PER FIRE ALARM VENDOR RECOMMENDATIONS AND INTERCONNECTING <br />WIRING DIAGRAMS. COORDINATE ALL WORK HEREIN RELATED TO THE BUILDING FIRE ALARM SYSTEM WITH THE BUILDING ENGINEER AND MAINTENANCE COMPANY. <br />7. GIVE NOTICES, SUBMIT, AND FILE ALL NECESSARY DRAWINGS FOR APPROVAL TO THE NATIONAL, STATE, AND LOCAL BUILDING AND FIRE DEPARTMENTS, OBTAIN PERMITS, APPROVALS <br />OR LICENSES NECESSARY TO CARRY OUT THIS WORK AND PAY ALL FEES THEREFORE. ARRANGE FOR FIRE DEPARTMENT INSPECTION AND TESTS INCLUDING CONTROLLED <br />INSPECTIONS OF ANY OR ALL PARTS OF THE WORK IF SO REQUIRED BY AUTHORITIES OR UTILITY COMPANIES HAVING JURISDICTION AND PAY ALL CHARGES FOR SAME. <br />8. AT THE CONCLUSION OF THE PROJECT THE CONTRACTOR SHALL PROVIDE A FUNCTIONALITY TEST AS REQUIRED BY CODE AND AN "AS -BUILT" FIRE ALARM RISER TO THE ENGINEER, <br />BUILDING, AND SUBMIT TO THE FIRE DEPARTMENT. <br />9. COPY OF THE FINAL LETTER OF APPROVAL SHALL BE FORWARDED TO BUILDING MANAGEMENT. <br />10, ENTIRE INSTALLATION SHALL BE COMPLETELY TESTED PRIOR TO THE FIRE DEPARTMENT INSPECTION. <br />\ <br />t \------- <br />E7 143 <br />....... <br />rw <br />4 <br />;r <br />Permit/Seal <br />i;Y <br />(:K) LEVEL 1 FIRE ALARM PLAN - B <br />ut�W'Jaq <br /><Pick location in Project Information> <br />3/4/2021 7:04:12 PM <br />Drawing N <br />0- FAM <br />
The URL can be used to link to this page
Your browser does not support the video tag.