Laserfiche WebLink
F O R T E1 J MEMBER REPORT PASSED <br /> Level,B2: Drop Beam <br /> 1 piece(s)3 1/2"x 11 7/8"2.0E Parallam®PSL <br /> Overall Length:11'7" <br /> 0 0 <br /> 11 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual®Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 4940 @ 2" 7656(3.50") Passed(650/0) -- 1.0 D+1.0 L(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 3847 @ 1'3 3/8" 8035 Passed(480/0) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Moment(Ft-lbs) 13494 @ 5'9 1/2" 19902 Passed(68%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.310 @ 5'9 1/2" 0.375 Passed(L/436) -- 1.0 D+1.0 L(All Spans) <br /> Total Load Defl.(in) 0.352 @ 5'9 1/2" 0.563 Passed(L/383) -- 1.0 D+1.0 L(All Spans) <br /> •Deflection criteria:LL(L/360)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor, <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Total Accessories <br /> 1-Column-DF 3.50" 3.50" 2.26" 596 4344 4940 Blocking <br /> 2-Column-DF 3.50" 3.50" 2.26" 596 4344 4940 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 11'7"o/c <br /> Bottom Edge(Lu) 11'7'o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead Floor Live <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) Comments <br /> 0-Self Weight(PLF) 0 to 11'7" N/A 13.0 — <br /> 1-Uniform(PSF) 0 to 11'7"(Front) 7'6" 12.0 100.0 Default Load <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 11/16/2020 8:27:37 PM UTC <br /> Chris Simpliciano <br /> Nickerson Engineering,LLC ForteWEB v3.0,Engine:V8.1.4.2,Data:V8.0.0.0 <br /> (425)61no©ni File Name: 20-149 Restech Remodel <br /> simpliciano@nickersonengineering.com �Ccycrhueu,cr <br /> Page 3/4 <br />