Laserfiche WebLink
MEMBER REPORT PASSED <br /> Level,B3: Drop Beam <br /> i piece(s)5 1/4"x 11 7/8"2.0E Parallam®PSL <br /> Overall Length:13' 1' <br /> 0 0 <br /> 12'6' <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual 0 Location Allowed Result LDF Loath Combination(Pattern) System:Floor <br /> Member Reaction(lbs) 6512 @ 2" 11484(3.50") Passed(57%) -- 1.0 D+1.0 L(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 5237 @ 1'3 3/8" 12053 Passed(43%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Moment(Ft-lbs) 20229 @ 6'6 1/2" 29854 Passed(68%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.355 @ 6'6 1/2" 0.425 Passed(L/431) -- 1.0 D+1.0 L(All Spans) <br /> Total Load Defl.(in) 0.441 @ 6'6 1/2" 0.637 Passed(L/347) -- 1.0 D+1.0 L(All Spans) <br /> •Deflection criteria:LL(L/360)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> Bearing Length Loads to Supports(lbs) <br /> Supports Total Available Required Dead Floor Live Total Accessories <br /> 1-Column-DF 3.50" 3.50" 1.98" 1279 5233 6512 Blocking <br /> 2-Column-DF 3.50" 3.50" 1.98" 1279 5233 6512 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Ong Intervals Comments <br /> Top Edge(Lu) 13'1"o/c <br /> Bottom Edge(Lu) 13'1"o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead Floor Live <br /> 'Vertical Loads Location(Side) Tributary Width (0.90) (1.00) Comments <br /> 0-Self Weight(PLF) 0 to 13'1" N/A 19.5 -- <br /> 1-Uniform(PSF) 0 to 13'1"(Front) 8' 12.0 100.0 Default Load <br /> 2-Uniform(PLF) 0 to 13'1"(Front) N/A 80.0 - <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support Information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 11/16/2020 8:27:37 PM UTC <br /> Chris Simpliciano <br /> Nickerson Engineering,LLC ForteWEB v3.0,Engine:V8.1.4.2,Data:V8.0.0.0 <br /> (425)610-4425 File Name: 20-149 Restech Remodel <br /> simplidano@nidcersonengineering.com Weyerhaeuser <br /> Page 4/4 <br />