My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1717 ROCKEFELLER AVE 2022-07-27
>
Address Records
>
ROCKEFELLER AVE
>
1717
>
1717 ROCKEFELLER AVE 2022-07-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2022 10:47:11 AM
Creation date
7/27/2022 10:46:24 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1717
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job Name: <br /> : W:A- A <br /> PrneipTaegd BY4VE1in State Sheet Metal <br /> Quantity:1 <br /> Variable Frequency Drive <br /> Variable Frequency Drives are factory installed and tested to provide supply fan motor speed <br /> Modulation. VFDs on the supply fan, as compared to inlet guide vanes or discharge dampers, are <br /> quieter, more efficient, and are eligible for utility rebates. All VFDs are designed to allow bypass if <br /> required. Bypass control will simply provide full nominal airflow in the event of drive failure. Bypass <br /> mode is indicated in the unit wiring manual. Modulating gas heat models with SZVAV allow tighter <br /> space temperature control with less temperature swing. <br /> Controls <br /> Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal <br /> block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. <br /> ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall <br /> make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors <br /> measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature <br /> control, minimizes drift from set point, and provides better building comfort. A centralized control shall <br /> provide anti-short cycle timing and time delay between compressors to provide a higher level of <br /> machine protection. <br /> High Pressure Cutout <br /> This option is offered for units that do not have High Pressure cutout as standard. <br /> Low Leak Economizer <br /> This accessory meets low leak requirements for ASHRAE90.1, IECC, and Title 24 standards; Allows <br /> 100 percent outdoor air supply from 0-100 percent modulating dampers; Comes standard with <br /> Barometric Relief; can be paired with Powered exhaust for additional building evacuation; Can paired <br /> with Fault Detection (FDD) to meet current mandatory Title 24 requirements. <br /> Discharge Line Thermostat <br /> A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of <br /> each system. This standard option provides extra protection to the compressors against high <br /> discharge temperatures in case of loss of charge, extremely high ambient and other conditions which <br /> could drive the discharge temperature higher. Discharge line thermostat is wired in series with high <br /> pressure control. When the discharge temperature rises above the protection limit, the bi-metal disc in <br /> the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature on the <br /> discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the <br /> compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset <br /> to resume operation on that stage. <br /> Shaft Gounding Ring (FIYSHGR001,002A) 12.5-25 Ton <br /> Shaft grounding rings shall be factory installed on all VFD driven motors to provide a conductive <br /> discharge path away from the motor bearings to ground. Bearing Protection Ring shall be maintenance <br /> free circumferential ring of conductive micro fibers that discharges voltages to ground. <br /> Human Interface <br /> The Trane Human Interface shall have a 5 inch color touchscreen display that conforms to FCC Part <br /> 15 Class B with an Ingress Protection Rating of IP24. The display text shall be readable by a person <br /> with 20/20 vision at a distance of 3 feet and 60° angle at lighting levels ranging from 100 lux- 25,000 <br /> lux. Also, the display shall operate at temperatures of-40°C to 70°C. Firmware and unit configurations <br /> shall be able to be restored via a USB storage device. <br /> Sequence of Operation (if applied in a SINGLE-ZONE CONSTANT-VOLUME SYSTEM or a <br /> CHANGEOVER BYPASS SYSTEM) <br /> B. SINGLE-ZONE CONSTANT-VOLUME SYSTEM <br />
The URL can be used to link to this page
Your browser does not support the video tag.