My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1717 ROCKEFELLER AVE 2022-07-27
>
Address Records
>
ROCKEFELLER AVE
>
1717
>
1717 ROCKEFELLER AVE 2022-07-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2022 10:47:11 AM
Creation date
7/27/2022 10:46:24 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1717
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job Name:WAA • <br /> Prepared By:E n State Sheet Metal <br /> Unit Tag:Y4V-1 <br /> Quantity:1 <br /> 1. OCCUPIED HEAT/COOL: <br /> The RTU shall operate the supply fan continuously and modulate (or cycle) compressors, modulate (or <br /> stage) heat, and/or enable airside economizing to maintain zone temperature at setpoint. The OA <br /> damper shall open to bring in the required amount of ventilation. <br /> 2. MORNING WARM-UP/PRE-COOL: <br /> The RTU shall operate the supply fan and modulate (or cycle) compressors or modulate (or stage) <br /> heat to raise/lower zone temperature to its occupied setpoint. The OA damper shall remain closed, <br /> unless economizing. <br /> D. CHANGEOVER BYPASS SYSTEM <br /> 1. OCCUPIED HEAT/COOL: <br /> Each VAV terminal shall use pressure-independent control, with airflow measurement, to vary primary <br /> airflow to maintain zone temperature at its occupied setpoint. The RTU shall modulate the bypass <br /> damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors, modulate (or <br /> stage) heat, and/or enable airside economizing based on current zone cooling/heating demands. The <br /> OA damper shall open to bring in the required amount of ventilation. <br /> 2. MORNING WARM-UP/PRE-COOL: <br /> Each VAV terminal unit shall vary primary airflow to raise/lower zone temperature to its occupied <br /> setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and <br /> modulate (or cycle) compressors or modulate (or stage) heat based on current zone cooling/heating <br /> demands. The OA damper shall remain closed, unless economizing. <br /> 3. COOLING/HEATING CHANGEOVER LOGIC: <br /> The System Controller shall determine the overall system cooling/heating mode based on "voting" <br /> from each zone. When the majority of zones require cooling, the RTU shall operate in cooling mode <br /> and any zone that requires heating shall reduce primary airflow to minimum. When the majority of <br /> zones require heating, the RTU shall operate in heating mode and any zone that requires cooling shall <br /> reduce primary airflow to minimum. <br /> 2020-02-10 17 OR•977 <br />
The URL can be used to link to this page
Your browser does not support the video tag.