Laserfiche WebLink
iliktir <br /> EVALUATION REPORT T N um r <br /> ® Originally Issued: 10/24/2013 Revised: 10/29/2020 Valid Through: 10/31/2021 <br /> SAN JUAN PRODUCTS 2.6 Diving equipment shall only be installed on Type I pools <br /> 850 East Davidson Avenue and shall comply with the requirements of and be installed in <br /> Eloy,Arizona 85131 accordance with Section 808 of the ISPSC or Section 5.8 of <br /> www.sanjuanpools.com ANSUNSPI-5. <br /> kenb@sanjuanpools.com <br /> 2.7 Pools that are located in flood hazard areas established in <br /> FIBERGLASS REINFORCED PLASTIC accordance with IRC Table R301.2 (1) shall comply with <br /> SWIMMING POOLS ISPSC Section 304 or 2012, 2009 and 2006 IRC Sections <br /> AG101.2 and AG103.3, as applicable. <br /> CSI Section: <br /> 13 11 00 Swimming Pools and Spas 2.8 Suction outlets shall be designed and installed in <br /> accordance with Section 3109.5 of the IBC, Section 310 of <br /> 1.0 RECOGNITION the ISPSC or Section AG106.1 of the 2012,2009 and IRC. <br /> San Juan Products pools described in this report were 2.9 Electrical, plumbing, pumping and water heating <br /> evaluated for use as residential swimming pools. The equipment and decking are beyond the scope of this report <br /> physical characteristics and durability properties of the pools and shall be installed in accordance with the applicable code <br /> were evaluated for compliance with the following codes: and the requirements of the building official. <br /> • 2018, 2015, 2012, 2009, 2006 International 2.10 Special features such as stairs and sloping entries shall <br /> Building Code®(IBC) be designed to the requirements of Section 809 of the ISPSC. <br /> • 2018, 2015, 2012, 2009, 2006 International <br /> Residential Code®(IRC) 2.11 Pools are produced by San Juan Products in Eloy,AZ. <br /> • 2018 and 2015 International Swimming Pool and <br /> Spa Code®(ISPSC) 3.0 PRODUCT USE <br /> 2.0 LIMITATIONS 3.1 General: San Juan Products pools recognized in this <br /> report are used in residential swimming pool applications <br /> Use of the Fiberglass Reinforced Plastic Swimming Pool using heated water that is circulated in a closed system. The <br /> shells recognized in this report is subject to the following swimming pool shells comply with the requirements in the <br /> limitations: 2018 and 2015 ISPSC and the 2012, 2009 and 2006 IRC <br /> Section AG103. Swimming pool shells are permanently <br /> 2.1 The Fiberglass Reinforced Plastic Swimming Pool shells installed in-ground. All pool shells are either Type 0 or Type <br /> shall be constructed and installed in accordance with this I as shown in Table I of this report and comply with Chapter <br /> report and the manufacturer's installation instructions. In the 8 of the 2018 and 2015 ISPSC or ANSUNSPI-5. <br /> event of a conflict,the more restrictive shall take precedence. <br /> 3.2 Installation: San Juan Products pool shells shall be <br /> 2.2 Clearances of the swimming pool shells from slopes set installed in accordance with this report and the <br /> forth in the 2018, 2015 and 2012 IBC Section 1808.7.3 or manufacturer's installation instructions. All necessary <br /> 2009 and 2006 IBC Section 1805.3.3, and IRC Section plumbing and electrical work shall comply with the local <br /> R403.1.7, as applicable, shall be observed. codes in effect. <br /> 2.3 Barriers shall comply with IBC Section 3109, ISPSC Subject to the building official's approval, the San Juan <br /> Section 305 or 2012,2009 and 2006 IRC Section AG105,as Products pool shells may be installed without a soil <br /> applicable. investigation by a registered design professional provided <br /> none of the following conditions are encountered at the site: <br /> 2.4 Slip resistance is outside the scope of this evaluation <br /> report. Reports of slip resistance tests that demonstrate • Groundwater within the excavation,where the pool <br /> compliance with Section 306.2 of the ISPSC or Section 8.1 floor will contact the soil at the time of installation. <br /> of ANSI/NSPI-5 shall be submitted to the building official • Un-compacted fill in contact with any portion of the <br /> for approval. pool shell. <br /> • Expansive-type soils. <br /> 2.5 A permanent label shall be applied to the pool equipment • Soil types with an angle of repose that will not <br /> stating the following:"The pool shall remain full of water at support the walls of the excavation at desired slopes. <br /> all times.Pool may be damaged if water level is allowed to • Adjacent structures, which may be in danger posed <br /> drop below the pool inlet. When appreciable drawdown is by the proposed pool location. <br /> noticed or if it becomes necessary to drain the pool, San Juan , <br /> 0. <br /> Pr duct h 1 e n cte for i ru tin ." <br /> The product described in this Unifonn Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of construction in order to satisfy and comply with -` <br /> (._ « <br /> the intent of the provision of the code,as noted in this report,and for at least equivalence to that prescribed in the cock in quality,strength,effectiveness,fire resistance,durability and safely, <br /> as applicable,in accordance with ISO Section 104.11.This document shall only be reproduced in its entirety.Copyright©2020 by International Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States. Ph:1-877-41ESRPT•Fax:909.472.4171 ANS <br /> I <br /> web:www.uniform-s.org•4755 East Philadelphia Street,Ontario,California 91761-2816—USA p h ACCREDITED <br /> (I((d� isawc t70s5 <br /> Product Codification engy. <br />