Laserfiche WebLink
14'414 <br /> '004 <br /> .. TI T Number: - ��` <br /> Originally Issued: 10/24/2013 Revised: 10/29/2020 Valid Through: 10/31/2021 <br /> If any of the above-mentioned conditions are encountered, <br /> excavation shall cease immediately. The conditions shall be <br /> investigated by a qualified registered design professional and I AE <br /> mitigation measures recommended, if possible. The s <br /> investigation report and recommendations provided by theIli <br /> registered design professional shall be submitted to the <br /> building official for review and approval prior to resuming d <br /> excavation. <br /> or <br /> The pool excavation profile shall have a minimum over-dig IAPMO UES ER-298 <br /> of 6 inches(152 mm)on the sides and 4 inches(102 mm)at <br /> the bottom. The backfill for the pool bottom shall consist of 6.0 SUBSTANTIATING DATA <br /> structurally stable sand or pea gravel up to a maximum of 3/8- <br /> inch (9.53 mm) diameter and compacted to match the pool Data has been submitted and is in accordance with ICC-ES <br /> floor profile. The pool shell shall sit finely on compacted Acceptance Criteria for In-Ground, Residential, Fiberglass <br /> backfill and be within 1 inch (25.4 mm) of level.Water-till Reinforced Plastic Swimming Pools and Permanently <br /> and backfill simultaneous operations shall commence with Installed Plastic Spas (AC274), approved December 2006 <br /> backfill washed in with water. Backfill level and water-fill (Editorially revised January 2017). Test reports are from <br /> level shall be approximately the same throughout filling laboratories in compliance with ISO/IEC 17025. <br /> procedure. <br /> 7.0 STATEMENT OF RECOGNITION <br /> After completion of the water-fill and backfill operation a <br /> bond beam shall be installed in accordance with the This evaluation report describes the results of research <br /> manufacturer's installation instructions and approved by the carried out by IAPMO Uniform Evaluation Service on San <br /> building official. Juan Products pools to assess conformance to the codes <br /> shown in Section 1.0 of this report and serves as <br /> 4.0 PRODUCT DESCRIPTION documentation of the product certification. Products are <br /> manufactured at locations noted in Section 2.11 of this report <br /> The San Juan Products pool details are described in Table I under a quality control program with periodic inspections <br /> of this report by model number. Each unit is one-piece under the supervision of IAPMO UES. <br /> fiberglass construction shop-formed over a mold. The pool <br /> has a minimum thickness of '/a inch (6.4 mm) fiberglass <br /> reinforced plastic (FRP), which is composed of roving rL M , <br /> thermosetting polymer matrix. The surface finish is f '. " " <br /> neopentyl glycol/isophthalic gel coat. Brian Gerber,P.E.,S.E. <br /> 5.0 IDENTIFICATION Vice President,Technical Operations <br /> Uniform Evaluation Service <br /> The Fiberglass Reinforced Plastic Swimming Pool shells ✓ c <br /> shall be identified as follows: <br /> 5.1 A label shall be affixed on at least one of the following: Richard Beck,PE,CBO,MCP <br /> product, packaging, installation instructions or descriptive Vice President,Uniform Evaluation Service <br /> literature. A label shall also be placed on the installed pool <br /> or equipment by the distributor or installer. i <br /> GP Russ Chan.y <br /> 5.2 The label shall include the company name or trademark, CEO,The IAPMO Group <br /> model number,the IAPMO Uniform ES Mark of Conformity <br /> and the Evaluation Report Number(ER-298)to identify the <br /> products recognized in this report. A die-stamp label may For additional information about this evaluation report please visit <br /> also substitute for the label. Either Mark of Conformity may ww •.uniform-es.org or email us at info uniform-es.org <br /> be used as shown below: <br /> Pegc 2 4 5- 318 <br />