Laserfiche WebLink
1 <br /> 1 Structural Engineering or by an individual holding valid registration <br /> 2 in another state as a civil or structural Engineer. I <br /> 3 <br /> 4 All shop drawings and the cover page of all calculation submittals <br /> 5 shall carry the Professional Engineer's original signature, date of I <br /> 6 signature, original seal, registration number, and date of <br /> 7 expiration. The cover page shall include the contract number, <br /> 8 contract title, and sequential index to calculation page numbers. 1 <br /> 9 Two copies of the associated design calculations shall be <br /> 10 submitted for approval along with shop drawings. <br /> 11 <br /> 12 Details for handholes and luminaire arm connections are available I <br /> 13 from the Bridges and Structures Office. <br /> 14 <br /> 15 Foundations for various types of standards shall be as follows: I <br /> 16 <br /> 17 Type PPB As noted on Standard Plan J-20.10 <br /> 18 Type PS As noted on Standard Plan J-21.10 <br /> 19 Type I As noted on Standard Plan J-21.10 111 <br /> 20 Type FB As noted on Standard Plan J-21.10 <br /> 21 Type RM As noted on Standard Plan J-21.10 , <br /> 22 Type CCTV As noted on Standard Plan J-29.15 <br /> 23 Type II As noted in the Plans. <br /> 24 Type III As noted in the Plans. <br /> 25 Type IV As noted in the Plans and Standard Plan J-27.10 I <br /> 26 Type V As noted in the Plans and Standard Plan J-27.10 <br /> 27 Type SD As noted in the Plans. <br /> 28 <br /> 29 When so indicated on the plans, the steel traffic signal standards and any associated <br /> 30 mast arms or luminaire arms shall be powder coated with a protective coating for <br /> 31 exterior galvanized steel. The pole fabricator also has the option to submit to the City I <br /> 32 for approval, their process of coating galvanized steel in order to paint/coat the poles. <br /> 33 The City of Everett will provide the paint color chip to the pole supplier for color <br /> 34 matching. III35 <br /> 36 CNH 8-20.2(9-29.12(1)) ELECTRICAL SPLICE MATERIALS.RTF <br /> 37 Fused Quick-Disconnect Kits <br /> 38 Section 9-29.7(2) is supplemented with the following: <br /> 39 <br /> 40 Soldered compression connections are not allowed. Illumination fused quick <br /> 41 disconnects shall be Type 65U, single disconnect per conductor. I <br /> 42 <br /> 43 CNH 8-20.2(9-29.19) Pedestrian Push Buttons.docx <br /> 44 Pedestrian Push Buttons <br /> 45 Section 9-29.19 is supplemented with the following: <br /> 46 <br /> 47 Accessible Pedestrian Station I <br /> 48 The pushbutton stations and adapters shall be Forest Green in color. The sign shall <br /> 49 be 9 inch by 15 inch, option G (MUTCD R10-3e), when used in conjunction with a <br /> 50 countdown type pedestrian signal display, or MUTCD R10-25 (9 inch by 12 inch) <br /> I <br /> INTERURBAN TRAIL TO YMCA PEDESTRIAN IMPROVEMENTS SPECIAL PROVISIONS <br /> WORK ORDER 3749 Page SP58 of SP68 MAY 2,2022 ' <br /> I <br />