Laserfiche WebLink
I <br /> 1 Individual micro-lens optics shall produce IES Type 2 or Type 3 full cutoff distributions with 0% <br /> 1 2 lumens above 90° nadir. The power supply shall have less than 20% total harmonic distortion <br /> 3 and a minimum power factor of 0.90. The EMC shall meet or exceed FCC CFR Part 15. <br /> 4 Transient voltages shall comply with ANSI C62.41 Cat. A. An integral surge protector shall <br /> I 5 meet ANSI/IEEE C62.45, C62.41.2, IEC61000-4-2, and IEC 61000-4-4. Each luminaire shall <br /> 6 be provided with a standard 3" x 3"ANSI label indicating the wattage and the light source type <br /> 7 (LED), using black letters on a reflective white background. <br /> I 8 <br /> 9 The finish shall be a fade and abrasion resistant, epoxy polyester powder coat with a light gray <br /> 10 color. The luminaire shall meet UL listing for wet locations and maintain an IP66 rating for the <br /> 11 optics compartment and an IP54 rating or better for the power compartment. <br /> I12 <br /> 13 The Street Luminaires shall meet or exceed the following initial delivered lumen output: <br /> 14 <br /> I 15 Small Luminaire (200W HPS relative equivalent): <br /> 16 Type 2 or Type 3 distribution: >_ 9,200 lumens <br /> 17 <br /> I 18 Medium Luminaire (250W HPS relative equivalent): <br /> 19 Type 2 or Type 3 distribution: >_ 11,700 lumens <br /> 20 <br /> I 21 Large Luminaire (400W HPS relative equivalent): <br /> 22 Type 2 or Type 3 distribution: >_ 18,000 lumens <br /> 23 <br /> 24 The following listed fixtures meet the required specifications: <br /> 25 <br /> 26 Small Luminaire: <br /> 27 <br /> I 28 Type 2 distribution: <br /> 29 Leotek GCM1-60J-MV-40K-2R-GY-095-PCR7-4B-RWG-WL-BSK <br /> 30 Schreder SMART2-US-24L093-NW-T2M-SV-GY D01-AA-AB <br /> 31 32 LED Roadway NXT-48M-0-7-2LB-5-GY-3-UL-X-4H-BIRD <br /> 33 Type 3 distribution: <br /> I 34 Leotek GCM1-60J-MV-40K-3R-GY-095-PCR7-4B-RWG-WL-BSK <br /> 35 Schreder SMART2-US-24L093-NW-T3M-SV-GY-D01-AA-AB <br /> 36 LED Roadway NXT-48M-0-7-3LB-5-GY-3-UL-X-4H-BIRD <br /> 37 <br /> 38 <br /> 39 Medium Luminaire: <br /> 40 <br /> I 41 Type 2 distribution: <br /> 42 Leotek GCM1-60J-MV-40K-2R-GY 125-PCR7-4B-RWG-WL-BSK <br /> 43 Schreder SMART2-US-36L134-NW-T2M-SV-GY D01-AA-AB <br /> 44 45 LED Roadway NXT-60M-0-7-2LB-5-GY-3-UL-X-4H-BIRD <br /> 46 Type 3 distribution: <br /> I 47 Leotek GCM1-60J-MV-40K-3R-GY 125-PCR7-4B-RWG-WL-BSK <br /> 48 Schreder SMART2-US-36L134-NW-T3M-SV-GY D01-AA-AB <br /> 49 LED Roadway NXT-60M-0-7-3LB-5-GY-3-UL-X-4H-BIRD <br /> 1 50 <br /> INTERURBAN TRAIL TO YMCA PEDESTRIAN IMPROVEMENTS SPECIAL PROVISIONS <br /> IWORK ORDER 3749 Page SP61 of SP68 MAY 2,2022 <br /> I <br />