SHKSARCHITECTS <br /> Correction Response — BUILDING/STRUCTURAL <br /> To Jeff Heilman and James Bronder <br /> City of Everett Permit Services <br /> 3200 Cedar 98Str201 1E2LII n „!Everett, WA 98201 �`�'J//From Jordan Inman2 <br /> 0 2020 <br /> Date 06/05/2020 C I TY O F E 1lE R E TT <br /> Project Project#B2004-039 Permit Services <br /> Baugh-Floyd Addition <br /> Re: Correction Notice#1 <br /> Jeff and James, <br /> Attached please find a written response to the building and structural review comments. The drawing <br /> revisions have been clouded. <br /> BUILDING/STRUCTURAL <br /> 1. Below grade walls can be insulated with minimum R-21 on the interior, R-15 continuous insulation on <br /> the interior, R-5 continuous rigid insulation on the interior with minimum R-13 insulation in a furred wall <br /> cavity or R-10 rigid insulation on the exterior from the top of the footing to the top of the concrete wall. <br /> The plans call out R-15 on the plan view(although not designated as continuous), and the section <br /> drawing shows R-10 Rigid insulation. The Wall Section 12 on sheet A3.3 shows Please correct the <br /> plans to clearly define which option you are proposing to use. <br /> The note on A2.0 -Basement Floor Plan has been revised to show continuous R-5 rigid <br /> insulation, with a minimum R-13 furred-out stud wall. <br /> Wall section 12/A3.3 has been revised to show R-5 rigid insulation with a minimum R-13 <br /> furred-out stud wall. <br /> 2. Several windows that meet the criteria specified in section R308.4.3 Glazing In Windows are not shown <br /> as tempered safety glass in the window schedule. Please verify the area of glazing and designate <br /> required safety glass as applicable. <br /> After reviewing the proposed windows in reference to R308.4.3, I found that window W203 <br /> does indeed require safety glazing; W203 has been revised to indicate safety glazing in A2.2— <br /> Second Floor Plan and the Window Schedule. <br /> Window W106, while indicated as "SG" in plan view,was not indicated as such in the <br /> schedule; the Window Schedule has been revised to indicate safety glazing for W106. <br /> There are several windows that meet some of the requirements in R308.4, but not all.The <br /> following are comments on windows I have found do not require safety glazing: <br /> - Window W102 and similar size casements (W104, W108,W202,W205) have a <br /> glazing area of 7.1 SF, less than the 9 SF listed in R308.4.3.Therefore, safety <br /> glazing is not required in these units. <br /> 1050 N. 38th St. <br /> Seattle, WA 98103 <br /> PH: 206.675.9151 <br /> FAX 206.675.9150 <br /> www.shksarchitects.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.