• . <br /> 1. Provide a letter from the engineer verifying that the plans have been reviewed and are consistent <br /> with the engineering calculations for lateral loads prepared by Sound Structural Solutions and that the <br /> gravity calculations prepared by Design lines are adequate for the proposed addition and alterations <br /> to the existing structure. All engineering should be incorporated into the drawings. <br /> Response: <br /> Construction plan Sheets 1-9 prepared by Design Lines,dated 11-21-2018,were provided <br /> to Sound Structural Solutions for their subsequent review and analysis,from which Sound <br /> Structural Solutions prepared a 28 page lateral analysis with calculations, SSS# <br /> s18811021, dated May 14 2019, signed and sealed by Ronald Skinner, P.E., license <br /> #40421, on 5/16/2019, and from which Sound Structural Solutions prepared <br /> construction plan Sheets S1, S2, S3, and S4, dated 5/15/2019, signed and sealed by <br /> Ronald Skinner, P.E., license #40421, on 5/16/2019. Ronald Skinner's seal is evidenced <br /> on the construction plan Sheets S1,S2,S3,and S4 and the lateral analysis. See attached <br /> letter from the designer confirming the gravity analysis calculations have been re- <br /> reviewed and confirmed that the structure is adequate for the gravity loads for the <br /> proposed addition to the existing structure. Lateral engineering is incorporated in the <br /> existing S sheet drawings. <br /> 2. The new walls enclosing the proposed Dining room, including the exterior wall shall be insulated <br /> with minimum R-21 per WSEC Please revise. <br /> Response: <br /> The three perimeter walls of the dining room have been specified to have R-21"Foam-It- <br /> Green"spray foam insulation @ 7.2 per inch. See note in upper right corner of the garage <br /> on Sheet 4, Main Floor Plan. <br /> 3. Provide detail of the connection of the new foundation and footings to the existing foundation. <br /> Response: <br /> The connection note is existing in the upper right corner of Sheet 2, Foundation Plan. <br /> 4. Provide section drawing showing the connection of the rim joist to the cantilevered floor joists <br /> that are supporting the ledger for the deck joists that are supporting the hot tub. <br /> Response: <br /> The hot tub has been removed from the project. A beam has been added between the <br /> cantilevered floor joists and the deck joists. <br /> 5. Provide #4 rebar stubbed out at 18"O.C, maximum at concrete porches capable of resisting <br /> differential settling. <br /> Response: <br /> The rebar connection delineation and note has been added to the front porch on Sheet 2, <br /> Foundation. <br /> 0 523 61sT ST SE © 425.879.3437 O brianbodge@msn.com <br /> Everett,WA 98203 <br /> 2/4 <br />