My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11625 AIRPORT RD SONRISE CHRISTIAN CENTER Geotech Report 2022-10-25
>
Address Records
>
AIRPORT RD
>
11625
>
SONRISE CHRISTIAN CENTER
>
Geotech Report
>
11625 AIRPORT RD SONRISE CHRISTIAN CENTER Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 2:09:09 PM
Creation date
8/25/2022 7:40:35 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11625
Tenant Name
SONRISE CHRISTIAN CENTER
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> GEOTECHNICAL EVALUATION <br /> EVERETT,WASHINGTON <br /> February 6,2018 <br /> I <br /> Wall Design Criteria <br /> "At-rest"Conditions(Lateral Earth Pressure—EFD+) 55 pcf(Equivalent Fluid Density) <br /> "Active"Conditions(Lateral Earth Pressure—EFD+) 35 pcf(Equivalent Fluid Density) <br /> Seismic Increase for"At-rest"Conditions 22H*(Uniform Distribution) <br /> (Lateral Earth Pressure) <br /> Seismic Increase for"Active"Conditions 8H*(Uniform Distribution) <br /> (Lateral Earth Pressure) <br /> Passive Earth Pressure on Low Side of Wall Neglect upper 2 feet,then 35o pcf EFD+ <br /> (Allowable,includes F.S.=1.5) <br /> Soil-Footing Coefficient of Sliding Friction(Allowable; 0.40 <br /> includes F.S.=1.5) <br /> "H is the height of the wall;Increase based on one in 2,50o year seismic event(2 percent probability of being exceeded in 5o years),+ <br /> EFD—Equivalent Fluid Density <br /> The stated lateral earth pressures do not include the effects of hydrostatic pressure generated by water <br /> accumulation behind the retaining walls. Uniform horizontal lateral active and at-rest pressures on the <br /> retaining walls from vertical surcharges behind the wall may be calculated using active and at-rest lateral <br /> earth pressure coefficients of o.3 and o.5,respectively(if necessary for the vaults). The soil unit weight of <br /> 125 pcf may be used to calculate vertical earth surcharges. <br /> To reduce the potential for the buildup of water pressure against the walls, continuous footing drains <br /> (with cleanouts) should be provided at the bases of the walls. The footing drains should consist of a <br /> minimum 4-inch diameter perforated pipe,sloped to drain,with perforations placed down and enveloped <br /> by a minimum 6 inches of pea gravel in all directions. Pumps may be required if gravity flow cannot be <br /> achieved. <br /> The backfill adjacent to and extending a lateral distance behind the walls at least 2 feet should consist of <br /> free-draining granular material. All free draining backfill should contain less than 3 percent fines <br /> (passing the U.S. Standard No. 200 Sieve)based upon the fraction passing the U.S. Standard No.4 Sieve <br /> with at least 3o percent of the material being retained on the U.S. Standard No. 4 Sieve. The primary <br /> purpose of the free-draining material is the reduction of hydrostatic pressure. Some potential for the <br /> moisture to contact the back face of the wall may exist,even with treatment,which may require that more <br /> extensive waterproofing be specified for walls,which require interior moisture sensitive finishes. <br /> We recommend that the backfill be compacted to at least 95 percent of the maximum dry density based on <br /> ASTM Test Method D1557. In place density tests should be performed to verify adequate compaction. <br /> Soil compactors place transient surcharges on the backfill. Consequently, only light hand operated <br /> equipment is recommended within 3 feet of walls so that excessive stress is not imposed on the walls. <br /> PO Box 82243 6 <br /> Kenmore,WA 98028 <br /> (206)331-1097 <br /> Cobaltgeo(@gmail.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.