1318 75TH ST SE 2022 Plans 2025-03-27
>
Address Records
>
75TH ST SE
>
1318
>
Plans
>
1318 75TH ST SE 2022 Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 9:17:27 AM
Creation date
9/6/2022 11:49:12 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Permit
B2201-048
Year
2022
Notes
NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(F) :50 CFM MIN EXHUAST FAN VENTTED TO EXTERIOR <br /> EGRESS W/WINDOW WELL 3'x3' EGRESS W/WINDOW WELL 3'x3' (5) :SMOKE ALARM PER R314 <br /> / 29'-6 1/2" / 22-5 1/2" (SC) :SMOKE ALARM/CO2 ALARM MIX HARDWIRED TO HOME WITH BACKUP BATTERY INTERCONNECTED. <br /> / /17 __. <br /> 9 \ J r (HID) :HEAT DECTOR FOR THE GARAGE <br /> N I CI) :WHOLE HOUSE FAN. <br /> WATER HEATER <br /> 13'-7 1/2'‘ 8, o, 3,_o. 13'-7 1/2" ' NOTES: <br /> j'' BEDROOM / , / BEDROOM <br /> 164SF 164 SF 1.TYPICAL EXTERIOR WALL:SIDING o/INFILTRATION BARRIER o/EXTERIOR SHEATHING PER STRUCTURAL PLANS/2X6 STUDS @ 16"0.C.w/R-21 BATT INSULATION AND 1/2"MIN. <br /> (S) GWB AT INSIDE FACE.CONCRETE TO BE FOXBLOCKS 2 5/8"RIGID INSUL ON BOTH SIDE WITH 6"CONCRETE WALL.R-21 <br /> VyF (S) 2.TYPICAL INTERIOR WALL:SIDING o/INFILTRATION BARRIER o/EXTERIOR SHEATHING PER STRUCTURAL PLANS/2X6 STUDS @ 16"O.C.w/R-21 BATT INSULATION AND 1/2"MIN. <br /> WF GWB AT INSIDE FACE w/P.V.A.PRIMER. <br /> c 3.PROVIDE LOCKI ON ALL PLUMBING OPENING <br /> ,,—....\f--. <br /> - \ 4.PROVIDE SOLID BLOCKING ABOVE ANY SUPPORTS <br /> UTILITY .. 5.PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICLE DRAFT OPENING AND TO PROVIDE <br /> �19 SF (SC) / HEATPUMP HEATPUMP CONDESSOR EFFECTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN TOP AND ROOF SPACE <br /> 21'-1py8. 6.GARAGE DOOR:PROVIDE 13/8"SOLID CORE DOOR OR EQUIV.20 MIN.RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE.DOOR TO BE EQUIPPED WITH A SELF-CLOSING <br /> \ 4- _ / DEVICE.(R302.5.1) <br /> \ 7.GARAGE WALL:SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2"GYPSUM BOARD APPLIED TO GARAGE SIDE.A 5/8"TYPE"X"GWB OR EQUIV.IS REQUIRED <br /> )_° (F) 0 \ r �I_ BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE.(R302.6&TABLE 302.6) <br /> BASEMENT o I II II II II II II_ 8.GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES,PORCHES,STAIRS,RAMPS,BALCONIES AND LANDINGS LOCATED MORE THAN 30"ABOVE THE FLOOR OR <br /> to BATHROOM LIVING ROOM v r GRADE BELOW.GUARD SHALL NOT BE LESS THAN 36"IN HEIGHT.OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4"SPHERE CANNOT PASS THROUGH.(R312) <br /> 0 54 SF 397 SF - ` m� l�$�I_I6.16$ 9-U 9.STAIR TREADS AND RISERS(R311.7):MAX.RISER HEIGHT SHALL BE 7 3/4".RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br /> ° m v I I I 1FIFM / DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8".THE MIN,TREAD DEPTH SHALL BE 10".DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8".FIREBLOCK <br /> a'- 8' / 4'-0" / F upI I I I/I II II I STAIRS PER IRC 302.11.ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS(R303.7).STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br /> 1 V/ fill 1 I I II JL____J 10. <br /> 7 )EGRESSINDOWS:OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS.BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44"ABOVE FLOOR.OPENABLE AREA <br /> \ \ \ S 5.7 SQ.FT.NET CLEAR MIN.EXCEPT 5.0 Q.FT.IS ALLOWED FOR AN OPENING WITHIN 44"OF FINISHED GRADE.(R310.1) <br /> DRYER:VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS.DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL.MAX.DUCT LENGTH PER <br /> TABLE M1502.4.4.1 OR M1502.4.4.2.(M1502) <br /> 10'-8 7/8" Vii. <br /> 31'-3 1/8" 12.ATTIC ACCESS:MIN.22"X30"AND REQUIRED AT AREAS GREATER THAN 30 SQ.FT.AND VERTICAL HEIGHT OF 30"OR GREATER.(R807.1)SEE M1305.1.3 FOR ADDITIONAL <br /> / / / / REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br /> 7'-01/8" 30-35/8" 13.TEMP.GLASSWINDOW <br /> / / / / 14./2"GWB UNDER STAIRWAY IN ENCLOSED SPACES <br /> 52'-0" 15.ALL BEDROOMS TO HAVE ELECTRIC RESISTANCE HEATING <br /> / / 16.BATHROOM WINDOW GLAZING AND STAIR WINDOW TO BE SAFTEY GLAZING(TEMPERED GLASS)PER R308.4.5 <br /> 17.WHOLE-HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED,BALANCED AND VERIFIED TO PROVIDE A FLOW RATE NOT LESS THAN THE MINIMUM REQUIRED BY <br /> SECTIONS M1505.4.3 AND M1505.4.4.TESTING <br /> SHALL BE PERFORMED ACCORDING TO THE VENTILATION EQUIPMENT MANUFACTURER'S INSTRUCTIONS,OR BY USING A FLOW HOOD,FLOW GRID,OR OTHER AIRFLOW MEASURING <br /> EGRESS W/WINDOW WELL 6'x3' DEVICE AT THE MECHANICAL VENTILATION FAN'S INLET TERMINALS,OUTLET TERMINALS OR GRILLES OR IN THE CONNECTED VENTILATION <br /> DUCTS.WHERE REQUIRED BY THE BUILDING OFFICIAL,TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY.A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE <br /> SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED <br /> TO THE BUILDING OFFICIAL AND BE POSTED IN THE DWELLING UNIT PER SECTION M1505.4.1.7.(M1505.4.1.6) <br /> O BASEMENT <br /> 1/8" = 1'-0" <br /> PERMT BLUE MOON REALTY LLC BASEMENT FLOOR PLAN <br /> # B2201 -048 PROPOSED SFR <br /> DATE: 4/25/2022 A2 ` <br />