My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2022 Plans 2025-03-27
>
Address Records
>
75TH ST SE
>
1318
>
Plans
>
1318 75TH ST SE 2022 Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 9:17:27 AM
Creation date
9/6/2022 11:49:12 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Permit
B2201-048
Year
2022
Notes
NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> • <br /> 3'-0" I <br /> EXTEIOR LANDING / A9 <br /> NOTES#19 <br /> 14'-8 1/4" f 14'-4 1/4" 22'-11 1/2" <br /> / f / / (F) :50 CFM MIN EXHUAST FAN VENTTED TO EXTERIOR <br /> 6'-23/4" 8'-6" -_ _- T-2" 7'-13/4" <br /> (S) :SMOKE ALARM PER R314 <br /> / 2"x 6" / DN \ / I IN \ \ (SC) :SMOKE ALARM/CO2 ALARM MIX HARDWIRED TO HOME WITH BACKUP BATTERY INTERCONNECTED. <br /> 16"OC S{(��� / <br /> R-21 S` <br /> C1UYig'1, PROVIDE(1)HR FIRE RATINGBETWEEN (I* :HEAT DECTOR FOR THE GARAGE <br /> io R to GARAGE AND LIVING SPACE AT <br /> / WALLS ANDCEILING ABOVE <br /> • \ /\ \ WF :WHOLE HOUSE FAN. <br /> \ to \ \ I. ircY I\ <br /> - BATHROOM \ NOTES: <br /> (F)50 SF q UPI 1 1 1 1 zr-ov2 <br /> N\N 2"x 6" / 1.TYPICAL EXTERIOR WALL:SIDING o/INFILTRATION BARRIER o/EXTERIOR SHEATHING PER STRUCTURAL PLANS/2X6 STUDS @ 16"0.C.w/R-21 BATT INSULATION AND 1/2"MIN. <br /> .,___: <br /> lilt <br /> 16"OC ( ��, �� 2 CAR GARAGE EN GWB AT INSIDE FACE <br /> \ R-21 l f g ) 533 SF 2.TYPICAL INTERIOR WALL:SIDING o/INFILTRATION BARRIER o/EXTERIOR SHEATHING PER STRUCTURAL PLANS/2X6 STUDS @ 16"0.C.w/R-21 BATT INSULATION AND 1/2"MIN. <br /> _ �b - M <br /> co GWB AT INSIDE FACE w/P.V.A.PRIMER. <br /> d N \ -- 3 (HID) N 3.PROVIDE FIREBLOCKING ON ALL PLUMBING OPENING <br /> Eo EGRESS (S) _ N 4.PROVIDE SOLID BLOCKING ABOVE ANY SUPPORTS <br /> A9 <br /> 5.PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICLE DRAFT OPENING AND TO PROVIDE <br /> iv \ 41 <br /> = E 4"CONCRETE SLAB EFFECTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN TOP AND ROOF SPACE <br /> BEDROOM LIVING ROOM/KITCHEN IL__4 = A9 Fl AND TAMP M 6.GARAGE DOOR:PROVIDE 13/8"SOLID CORE DOOR OR EQUIV.20 MIN.RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE.DOOR TO BE EQUIPPED WITH A SELF-CLOSING <br /> �- 124 SF 356 SF -- /8":12"TO GARAGE DOOR DEVICE.(R302.5.1) <br /> o - \ (S) --- 7.GARAGE WALL:SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2"GYPSUM BOARD APPLIED TO GARAGE SIDE.A 5/8"TYPE"X"GWB OR EQUIV.IS REQUIRED <br /> 11 1 BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE.(R302.6&TABLE 302.6) <br /> N c. 10'-0 18'-3 1/2* DN GUARD RAILINGS NOTES#18 HEATPUMP CONDESSOR 8.GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES,PORCHES,STAIRS,RAMPS,BALCONIES AND LANDINGS LOCATED MORE THAN 30"ABOVE THE FLOOR OR <br /> EnWF // MAIN INP' / GRADE BELOW.GUARD SHALL NOT BE LESS THAN 36"IN HEIGHT.OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4"SPHERE CANNOT PASS THROUGH.(R312) <br /> yyF oril <br /> R302.5.1 FIRE RATED DOOR 9.STAIR TREADS AND RISERS(R311.7):MAX.RISER HEIGHT SHALL BE 7 3/4".RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br /> iv \: \ DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8".THE MIN,TREAD DEPTH SHALL BE 10".DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8".FIREBLOCK <br /> CO ( KITCHEN \ / STAIRS PER IRC 302.11.ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS(R303.7).STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br /> �7 'n PANTR • 11ns ISLAND HEATPUMP I I 6 I 1 311.7.E <br /> P 4•-751a• 12'-71/8" 1 <br /> IF"/ <br /> 15 SF (SC) o �� 11 1 1 <br /> \ - . `�' 1 1 1 1 1 i� 10.EGRESS WINDOWS:OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS.BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44"ABOVE FLOOR.OPENABLE AREA <br /> �� M ..•0) I I l I 1 L / / col IS 5.7 SQ.FT.NET CLEAR MIN.EXCEPT 5.0 SQ.FT.IS ALLOWED FOR AN OPENING WITHIN 44"OF FINISHED GRADE.(R310.1) <br /> N- i• v 10'-0• ( m 11.DRYER:VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS.DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL.MAX.DUCT LENGTH PER <br /> BATHROOM c � 1111 I F LAUNDRY ROOM/STAIRS TO BASEMENT TABLE M1502.4.4.1 OR M1502.4.4.2.(M1502) <br /> F- 50 SF (F) 146 SF 1 1 1 1 \ 1 Eo 12.ATTIC ACCESS:MIN.22"X30"AND REQUIRED AT AREAS GREATER THAN 30 SQ.FT.AND VERTICAL HEIGHT OF 30"OR GREATER.(R807.1)SEE M1305.1.3 FOR ADDITIONAL <br /> En <br /> ^� <br /> \ \ \ \ ` I 1 O8 w/o REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br /> k- I \ 13.TEMP.GLASS WINDOW <br /> a 32'-2 1/8" ao\ 19'-9 7/8" \ 14.1/2"GWB UNDER STAIRWAY IN ENCLOSED SPACES <br /> / // 0, �� 15.ALL BEDROOMS TO HAVE ELECTRIC RESISTANCE HEATING <br /> \__ <br /> 2"x 6" 16.BATHROOM WINDOW GLAZING AND STAIR WINDOW TO BE SAFTEY GLAZING(TEMPERED GLASS)PER R308.4.5 <br /> 17.WHOLE-HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED,BALANCED AND VERIFIED TO PROVIDE A FLOW RATE NOT LESS THAN THE-MINIMUM REQUIRED BY <br /> 2"x 6" 100 CFM Vented hood DN \ VENTTED DRYER TO OUTSIDE 16'OC SECTIONS M1505.4.3 AND M1505.4.4.TESTING <br /> 16"OC to exterior R-21 SHALL BE PERFORMED ACCORDING TO THE VENTILATION EQUIPMENT MANUFACTURER'S INSTRUCTIONS,OR BY USING A FLOW HOOD,FLOW GRID,OR OTHER AIRFLOW MEASURING <br /> R-21 DEVICE AT THE MECHANICAL VENTILATION <br /> 0"� FAN'S INLET TERMINALS,OUTLET TERMINALS OR GRILLES OR IN THE CONNECTED VENTILATION <br /> A9 <br /> ./i, EXTERIOR LANDING DUCTS.WHERE REQUIRED BY THE BUILDING OFFICIAL,TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY.A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE <br /> NOTES#19 SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED <br /> 52'-Or' TO THE BUILDING OFFICIAL AND BE POSTED IN THE DWELLING UNIT PER SECTION M1505.4.1.7.(M1505.4.1.6) <br /> / / 18.GUARD RAILS IN GARAGE STAIRS SHALL BE 36"MINIMUM HEIGHT.SHALL NOT ALLOW 4"SPHERE THROUGH OPENINGS AND NOT ALLOW 6"SPHERE ON BOTTOM OPENING.GUARD <br /> RAILS IN GARAGE STAIRS SHALL COMPLY WITH R312.1 <br /> 19.EXTEIOR LANDING TO BE ON BOTH STAIR ENTRANCES.MINIMUM 36"X36"WITH A 4"SLAB PER R311.7.6 <br /> 10 1/8" <br /> FLOOR <br /> 1/8" = 11-0" <br /> PERMT BLUE MOON REALTY LLC MAIN FLOOR PLAN <br /> < <br /> # B2201 -048 PROPOSED SFR <br /> A3 < <br /> DATE: 4/25/2022 < <br /> < <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.