My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2022 Plans 2025-03-27
>
Address Records
>
75TH ST SE
>
1318
>
Plans
>
1318 75TH ST SE 2022 Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 9:17:27 AM
Creation date
9/6/2022 11:49:12 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Permit
B2201-048
Year
2022
Notes
NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> 1 <br /> A9 <br /> 12'-5 1/2" 16'-8" 22'-11 1/2" (F) :50 CFM MIN EXHUAST FAN VENTTED TO EXTERIOR <br /> / (S) :SMOKE ALARM PER R314 <br /> 6'-23/4" 15'-7" 30'-31/4" <br /> / / // / (SC) :SMOKE ALARM/CO2 ALARM MIX HARDWIRED TO HOME WITH BACKUP BATTERY INTERCONNECTED. <br /> (J. :HEAT DECTOR FOR THE GARAGE <br /> WF :WHOLE HOUSE FAN.80 CFM TO RUN EVERY 2 OF 4 HOURS <br /> \ �� \r--91 \ L\ 71 I II I \ I 0 A \ \ <br /> M °� NOTES: <br /> "v <br /> m ih\ / EGRESS o ' I I I I co 1.TYPICAL EXTERIOR WALL:SIDING o/INFILTRATION BARRIER o/EXTERIOR SHEATHING PER STRUCTURAL PLANS/2X6 STUDS @ 16"O.C.w/R-21 BATT INSULATION AND 1/2"MIN. <br /> rn m - BEDROOM' 1 1 I <br /> LO L- i. io EGRESS GWB AT INSIDE FACE. <br /> i co <br /> 123 SF I I I I \ 2.TYPICAL INTERIOR WALL:SIDING o/INFILTRATION BARRIER o/EXTERIOR SHEATHING PER STRUCTURAL PLANS/2X6 STUDS @ 16"O.C.w/R-21 BATT INSULATION AND 1/2"MIN. <br /> GWB AT INSIDE FACE w/P.V.A.PRIMER. <br /> c WF �)� MASTER BEDROOM \ 3.PROVIDE FIREBLOCKING ON ALL PLUMBING OPENING <br /> Eci <br /> 4� F� 4.PROVIDE SOLID BLOCKING ABOVE ANY SUPPORTS <br /> \ 12'-0" " ` to co to 5.PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICLE DRAFT OPENING AND TO PROVIDE <br /> 4 SECOND FLOORlommi 1--- <br /> A9 EFFECTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN TOP AND ROOF SPACE <br /> LIVING ROOM '- on 6.GARAGE DOOR:PROVIDE 13/8"SOLID CORE DOOR OR EQUIV.20 MIN.RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE.DOOR TO BE EQUIPPED WITH A SELF-CLOSING <br /> \ 455 SF o� N DEVICE.(R302.5.1) <br /> c \ �/ EGRESS 22'-1 1/2" - 7.GARAGE WALL:SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2"GYPSUM BOARD APPLIED TO GARAGE SIDE.A 5/8"TYPE"X"GWB OR EQUIV.IS REQUIRED <br /> BEDROOM �N / i� BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE.(R302.6&TABLE 302.6) <br /> Co too \ 50 123 SF N- / - 8.GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES,PORCHES,STAIRS,RAMPS,BALCONIES AND LANDINGS LOCATED MORE THAN 30"ABOVE THE FLOOR OR <br /> N , CO3'-U' N <br /> iN.n g. x- GRADE BELOW.GUARD SHALL NOT BE LESS THAN 36"IN HEIGHT.OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4"SPHERE CANNOT PASS THROUGH.(R312) <br /> N WF s) N (SC) r, 9 STAIR TREADS AND RISERS(R311.7):MAX.RISER HEIGHT SHALL BE 7 3/4".RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br /> o - 0 (S) 0DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8".THE MIN,TREAD DEPTH SHALL BE 10".DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8".FIREBLOCK <br /> EN o STAIRS PER IRC 302.11.ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS(R303.7).STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br /> b 12'-0" \ 311.7.6) <br /> N. , 16'-4 1/2" 10.EGRESS WINDOWS:OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS.BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44"ABOVE FLOOR.OPENABLE AREA <br /> \ \' a \ \ IS 5.7 SQ.FT.NET CLEAR MIN.EXCEPT 5.0 SQ.FT.IS ALLOWED FOR AN OPENING WITHIN 44"OF FINISHED GRADE.(R310.1) <br /> BATHROOM =MI `n to 11.DRYER:VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS.DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL.MAX.DUCT LENGTH PER <br /> 72 SF EGRESS CLOSET BATHROOM (F) m % TABLE M1502.4.4.1 OR M1502.4.4.2.(M1502) <br /> �\ c (F) co 71 SF 77SF Zo - \ U' 12.ATTIC ACCESS:MIN.22"X30"AND REQUIRED AT AREAS GREATER THAN 30 SQ.FT.AND VERTICAL HEIGHT OF 30"OR GREATER.(R807.1)SEE M1305.1.3 FOR ADDITIONAL <br /> \ 12'-0" REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br /> Xio viZo 10'-6" 11.-4" gm 13.TEMP.GLASS WINDOW <br /> c a 1 1 1 / / 14./2"GWB UNDER STAIRWAY IN ENCLOSED SPACES <br /> \;"4-\ \io\ >KN <br /> "" g 4 - M\ \ \ 15.ALL BEDROOMS TO HAVE ELECTRIC RESISTANCE HEATING <br /> 16.BATHROOM WINDOW GLAZING AND STAIR WINDOW TO BE SAFTEY GLAZING(TEMPERED GLASS)PER R308.4.5 <br /> 17.WHOLE-HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED,BALANCED AND VERIFIED TO PROVIDE A FLOW RATE NOT LESS THAN THE MINIMUM REQUIRED BY SECTIONS <br /> I M1505.4.3 AND M1505.4.4.TESTING <br /> 16'-7 3/8" 7'-10 3/4" 4'-7 3/8" 10'-9 1/2" 12'-2"/ / / I / SHALL BE PERFORMED ACCORDING TO THE VENTILATION EQUIPMENT MANUFACTURER'S INSTRUCTIONS,OR BY USING A FLOW HOOD,FLOW GRID,OR OTHER AIRFLOW MEASURING <br /> / DEVICE AT THE MECHANICAL VENTILATION FAN'S INLET TERMINALS, <br /> 52'-0" OUTLET TERMINALS OR GRILLES OR IN THE CONNECTED VENTILATION <br /> / DUCTS.WHERE REQUIRED BY THE BUILDING OFFICIAL,TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY.A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE <br /> 2 \ SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED <br /> A9 1 TO THE BUILDING OFFICIAL AND BE POSTED IN THE DWELLING UNIT PER SECTION M1505.4.1.7.(M1505.4.1.6) <br /> O SECOND FLOOR <br /> 1/8" = 1'-0" <br /> PERMT BLUE MOON REALTY LLC SECOND FLOOR PLAN <br /> # B2201 -048 PROPOSED SFR <br /> DATE: 4/25/2022 A4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.