My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2702 BROADWAY 2019 Plans 2022-10-24
>
Address Records
>
BROADWAY
>
2702
>
Plans
>
2702 BROADWAY 2019 Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 8:11:51 AM
Creation date
10/24/2022 7:57:54 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2702
Permit
B1910-028
Year
2019
Notes
DINING AREA REMODEL, DEMO & REVISE ROOF AREA
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO <br />COMMENCEMENT OF WORK AND WILL IMMEDIATELY CONTACT ARCHITECT <br />FOR ANY DISCREPANCIES. <br />2. DO NOT DIMENSION DRAWINGS, CONTACT ARCHITECT OFFICE FOR ANY <br />CLARIFICATIONS. <br />3. ALL DIMENSIONS ARE SHOWN TO FACE OF FRAMING, UNLESS NOTED <br />OTHERWISE (UNO). <br />4. ADA COMPLIANCE PER ICC Al 17.1-2009 <br />5. FIRE EXTINGUISHERS SHALL BE PROVIDED BY CONTRACTOR, QUANTITIES <br />AND LOCATIONS TBD BY FIRE MARSHALL. <br />6. VERIFY ALL ROUGH OPENING REQUIREMENTS WITH DOOR AND WINDOW <br />MANUFACTURERS PRIOR TO FRAMING, <br />7. PER WASHINGTON STATE ENERGY CODE, ALL INSULATION MATERIALS TO <br />BE CLEARLY IDENTIFIED AND MARKED W/ LABELING VISIBLE FOR <br />INSPECTION. <br />1) GENERAL CONTRACTOR (GC) SHALL TAKE ALL NECESSARY PRECAUTIONS <br />TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON THE JOB <br />DURING DEMOLITION INCLUDING, BUT NOT LIMITED TO, FALL PROTECTION, <br />HAZARDOUS MATERIAL EXPOSURE, EXPOSED ELECTRICAL AND BRACING AS <br />NEEDED <br />2) GENERAL CONTRACTOR (GC) SHALL REMOVE ALL DEBRIS & EQUIPMENT <br />DAILY DURING DEMOLITION WORK <br />3) GC SHALL PATCH AND REPAIR ALL DAMAGED SURFACES TO MATCH <br />ADJACENT SURFACES AS REQUIRED <br />4) GC SHALL FIELD VERIFY ALL EXISTING SITE AND BUILDING CONDITIONS <br />PRIOR TO DEMOLITION <br />5) DEMOLITION MEANS AND METHODS ARE THE CONTRACTORS <br />RESPONSIBILITY <br />6) SINGLE RESTROOM TO BE AVAILABLE AND FUNCTIONAL AT ALL TIMES FOR <br />EMPLOYEES DURING RENOVATION <br />7) ABANDONED PIPES SHALL BE CAPPED IN A MANNER TO CONCEAL WITHIN <br />WALL, CEILING OR FLOOR <br />8) GC TO INSTALL AND MAINTAIN TEMPORARY VISQUEEN DUST PARTITION - <br />COORDINATE LOCATION IN FIELD WITH FRANCHISEE - PROVIDE TIGHT SEAL <br />Mark Description <br />REMOVE LIGHT FIXTURES - CAP POWER AND PAINT COVER, PATCH AND <br />REPAIR WALL PRIOR TO NEW FINISH <br />�2 EXISTING AWNINGS / CANOPIES TO BE REMOVED - RETAIN CIRCUITS FOR <br />REUSE - PATCH, REPAIR, AND PREP SURFACES <br />EXISTING "WAVE" FINISH TO BE REMOVE, PRIME AND PREP SURFACE FOR <br />NEW PAINT COLOR PER FINISH ELEVATIONS <br />® REMOVE ALL "LONG JOHN SILVERS" SIGNAGE, CAP POWER AND PAINT <br />COVER - PREP SURFACE BELOW FOR NEW FINISH <br />�5 REMOVE EXISTING PYRAMID ROOF, FRAMING & SKIRT, LIGHT FIXTURES <br />AND FRAMING - RETAIN CIRCUITS FOR RE -USE <br />REMOVE COLONEL SIGN CABINET - DISCONNECT POWER & - RETAIN <br />CIRCUITS FOR RE -USE <br />�7 REMOVE EXISTING AWNING & ATTACHMENT ASSEMBLY - PATCH AND <br />REPAIR SURFACE BELOW, PREP FOR NEW FINISH <br />® REMOVE EXISTING "KFC" LETTERSET, SIGN FACE AND CABINET <br />® REMOVE "COUNTRY FRIED CHICKEN" CABINET & LETTERING - <br />DISCONNECT FROM POWER AND SAVE CIRCUIT FOR RE -USE <br />10 PREP SURFACE FOR NEW EIFS TREATMENT - SEE A501 <br />11 REMOVE WALL SCONCE FIXTURES - CAP POWER AND PAINT CAP, SAVE <br />CIRCUIT FOR RE -USE <br />Demo Elevations <br />PER EMC 19.36 <br />SIGN CATEGORY: <br />ALLOWABLE FREE STANDING SIGNS: <br />MAX SIZE OF FREESTANDING SIGN: <br />MAX SIZE OF WALL SIGNS: <br />MAX PROTRUSION OF WALL SIGNS: <br />BACKLIT CABINET SIGNS MAX SIZE: <br />SOUTH ELEVATION <br />TOTAL FACADE AREA: <br />ALLOWABLE WALL SIGN AREA: <br />AREA OF BACKLIT WALL SIGN: <br />AREA OF WALL SIGNS (OTHER): <br />FREE STANDING SIGNS: <br />AREA OF FREE STANDING SIGN: <br />EAST ELEVATION <br />TOTAL FACADE AREA: <br />ALLOWABLE WALL SIGN AREA: <br />AREA OF BACKLIT WALL SIGN: <br />AREA OF WALL SIGNS (OTHER): <br />FREE STANDING SIGNS: <br />AREA OF FREE STANDING SIGN: <br />NORTH ELEVATION <br />TOTAL FACADE AREA: <br />ALLOWABLE WALL SIGN AREA: <br />AREA OF BACKLIT WALL SIGN: <br />AREA OF WALL SIGNS (OTHER): <br />FREE STANDING SIGNS: <br />AREA OF FREE STANDING SIGN: <br />ZONE UM=B <br />1 PER STREET FRONTAGE <br />40SF <br />32SF OR 15% OF FACADE (MAX 100SF) <br />12" <br />6SF <br />1520 SF <br />100 SF <br />0 SF <br />30.7 SF <br />1 <br />20.1 SF <br />665 SF <br />100 SF <br />0 SF <br />99.8 SF <br />0 <br />0 SF <br />1540 SF <br />100 SF <br />0 SF <br />73.1 SF <br />0 <br />0 SF <br />1) ALL SURFACES TO BE THOROUGHLY CLEANED AND DRIED BEFORE FINISH <br />WORK (PAINT, PANELS, ETC) TO BE APPLIED <br />2) WALL / ROOF AREAS TO BE REPAIRS FROM DEMOLITION WORK PRIOR TO <br />BEGINNING FINISH WORK <br />3) ALL PAINT TO ALIGN AND TERMINATE WITH ARCHITECTURAL ELEMENTS <br />UNLESS OTHERWISE NOTED <br />4) REFER TO SHEET A302 FOR PAINT FINISH SCHEDULE <br />South Elevation - Proposed <br />Mark I Description <br />0 NEW DRIVE-THRU CANOPY - VERIFY SIZE WITH VENDOR <br />2� EXISTING PARAPET COPING TO BE REPAIRED, SEALED AND PAINTED <br />NEW PARAPET COPING AND TRIM FINISH TO MATCH EXISTING TOWER <br />NEW ROOF MOUNT LIGHT ATTACHED TO INTERIOR OF PARAPET <br />�5 NEW VINYL GRAPHICS APPLIED TO NEW TOWER PANELS (WALL SIGN) 86.7 <br />SF - REFER TO A301 FOR SIGN CALCULATIONS <br />�6 PAINT 4" WIDE BORDER @ WINDOWS & DOORS PER ELEVATION <br />7� THOROUGHLY CLEAN AND ALLOW TO DRY ALL STONEWORK PRIOR TO <br />PAINTING - APPLY EXTERIOR PRIMER AS NEEDED <br />® THOROUGHLY CLEAN AND ALLOW TO DRY ALL EXISTING EXTERIOR <br />FINISH WORK PRIOR TO PAINTING - APPLY EXTERIOR PRIMER AS NEEDED <br />EXISTING DOOR / WINDOW TO REMAIN - PROTECT DURING DEMO, <br />CONSTRUCTION AND REFINISH WORK <br />10 EXISTING COOLER WALL / ROOF / TRIM - THOROUGHLY CLEAN AND PREP <br />SURFACE FOR NEW FINISH - PROVIDE PRIMER FOR APPROPRIATE <br />SURFACE MATERIALS <br />11 EXISTING DOWNSPOUT TO REMAIN, REPAIR AS NEEDED - PAINT TO <br />MATCH WALL COLOR BEYOND <br />12 24" LED CABINET "KFC" LETTERING SIGN (13.1 SF) -REFER TO A301 FOR <br />SIGN CALCULATIONS - COLOR AS SHOWN <br />13 FREESTANDING SIGN (20.1 SF) REFER TO A301 FOR SIGN <br />CALCULATIONS <br />14 STENCIL PAINTED GRAPHIC ELEMENT (WALL SIGN) - REFER TO A301 <br />15 EXISTING SERVICE METER - PROTECT DURING CONSTRUCTION <br />16 EXISTING ROOF ACCESS LADDER - PAINT TO MATCH WALL BEYOND <br />17 EXISTING RECESSES, GROOVES OR OTHER FINISH FACADE FORMS TO BE <br />FILLED WITH EFTS TO LEVEL FINISH <br />119 <br />XISTIN IXTUR REMAIN-- PAINT MATCH ALL BEY ND <br />NEW EXTERIOR AWNING /LOUVER, REFER TO FLOOR PLAN FOR SIZES <br />\ 1 <br />East Elevation -Pro <br />Scale: 1 /4"=1'-0„ <br />Scale: 1 /4"=1'-0" <br />o <br />0 <br />V/? <br />0 <br />OD <br />30 <br />0 <br />o N <br />> <br />1, <br />w <br />V/) <br />0 N <br />00 <br />z <br />0a <br />N <br />� <br />W <br />x <br />L <br />�LL <br />3M <br />Q N <br />tN <br />0 N <br />z00 <br />0 <br />n N <br />N <br />Q <br />00 <br />N v <br />V5506 REGISTERED <br />ARCHITECT <br />AEL C. PER <br />STATE OF WASHINGTO <br />� * M <br />ml I Ma - e � W W 144 <br />ORIGINAL RECIPE <br />SINCE89 0 <br />�w <br />d= <br />N� <br />r <br />a <br />O <br />0 <br />o <br />W <br />E <br />MN <br />aD <br />a � <br />o <br />a'. <br />0 <br />CU <br />Q <br />egg <br />9 E <br />-�--+ <br />0 <br />a t <br />O <br />W <br />W <br />a > <br />L <br />$Q <br />tU <br />E <br />O <br />� a - <br />a <br />E <br />N <br />> <br />a_ <br />W <br />0 <br />w <br />Z-5z <br />C.) <br />Za0 <br />L d W <br />zoo <br />U <br />LL <br />M. 1.9 <br />c <br />� <br />o � � <br />Job #: <br />2019-16 <br />Drawn: <br />KJH JRS <br />Checked: <br />MCP <br />Issue Date: <br />10.14.2019 <br />Submittal- <br />10-15.2019 <br />10.14.2019 <br />W <br />06 <br />z <br />0 <br />U) <br />w <br />Scale:1/8"=1'-0" <br />
The URL can be used to link to this page