.---------------------------------- REVISIONS
<br />1�-------------�
<br />HORIZ MTL SIDING t i -- - ---- _
<br />SYSTEM W/ J-TRIM
<br />ATTACHED TO HSS _ L _
<br />ANTI -CLIMB FENCE AT COLUMN W/ 16 GA SHT F----- REMOVE EXISTING
<br />GATE PANEL MTL CLIP ANGLES PIPE/METAL GRATE
<br />PLATFORMS AND CONC.
<br />ATTACH It THRU
<br />2x2 ANGLE WRAPPING --`- ANIT-CLIMB FENCE TO PIER
<br />EDGE OF COLUMN TO
<br />SECURE FENCE COLUMN
<br />- -- GRIND SMOOTH - FLUSH
<br />TRAFFIC z5
<br />f k W/TOP OF CURB, TYP.
<br />_ 2x2xY4" GATE FRAME COATING, TYP t° z
<br />J
<br />O — lz—Q m—— _
<br />Ira
<br />z Orr „..a �. -h, ry. �S" ATTACHMENT, CLOSURE
<br />8x%' CONT. PLATE FROM m � �� �
<br />COLUMN TO COLUMN w x h K fi;k
<br />FENCING TO BE
<br />BETWEEN GATE POSTS m Q
<br />c t DESIGN/BUILD BY k Via"
<br />611
<br />CONTRACTOR"
<br />COLUMN BEYOND
<br />...:.
<br />`x PLATE CONNECTION �\(�WjJ COLUMN DEMO j\/�Wj/ HORIZ GUARD RAIL
<br />f 1
<br />3
<br />t $ S
<br />k i
<br />x. Y '1
<br />r. RF001 x. » RF004 » , »
<br />z — — _ — — —
<br />_,_ SCALE: 1 1 2 1 0 SCALE. 1 2
<br />_., r. .u,... ., .ti. .max ,... .. a z,.-,. .. fs .y ,....-.,...,. 4 ..*.. :F .:. ,. -. � , ...... ,; .-. iS,•:. �-€ ,..:: ,,...,
<br />2x2x/4 ANGLE
<br />,.
<br />,�� LENGTH OF FENCING
<br />ANTI —CLIMB FENCE
<br />FENCE GATE @ SILL MTL PANEL CONNECTION @ CURB
<br />15 SCALE: 1-1/2»=1'-0» RF014 SCALE: 1-1/2"=1'-0» RFo10
<br />- ANGLE THAT SPANS
<br />1 FROM COLUMN TO
<br />- COLUMN, SEE
<br />WIRE FENCING
<br />-- - - - - -- - -- - - -- STRUCTURAL
<br />INTERIOR CLOSURE
<br />PLATE BY TERMINATION BAR &
<br />DESIGN/BUILD ANGLE SEALANT
<br />CONTRACTOR 1 :, $ V, O, BASE FLASHING
<br />BELOW —
<br />_ �$ 5 � ADHERE TO HSS COLUMN
<br />/ PIPE
<br />OUTSIDE ENCLOSURE w 3 rvN NEW INSULATION AND
<br />ANTI -CLIMB FENCE 3 EXISTING
<br />2 U-Jw ROOFING TO MATCH
<br />- - - -Q-°a---- - METAL PANEL I - � � � � £00* r � �� � r � BASE t ATTACHED TO
<br />o a (E) CONC SLAB
<br />w FLASH G
<br />METAL PANEL c� m
<br />BEL0 V-
<br />CURB. a
<br />j II BELOW
<br />i
<br />-- -
<br />--- -- - METAL PANEL SECTIONS
<br />\ REGISTERED
<br />CENTERED 8'-0" COLUMNS 6135
<br />10, 7 CONNECTION @ OUTSIDE CORNER % COLUMN CONNECTION @ CURB ARCHITECT
<br />ZD W / RF006 L » : » RF002
<br />m - SCALE: 1-1 /2» =1, —0» SCALE: 1-1 /2 =1 —0 ��
<br />11 MICHAEL R. UMALLEY
<br />STATE OF WASHINGTON
<br />ANTI -CLIMB FENCE AND
<br />INSIDE ENCLOSURE UNISTRUT TO BE DESIGN
<br />CLOSURE PLATE, UNISTRUT AND 1 /BUILD BY CONTRACTOR
<br />FENCE & METAL PANEL MTL PANEL OUTSIDE CORNER FENCING
<br />ONS CTOR. ATTACHN/BUILD BY CONDUIT RUNNING AND
<br />1 » , » RF015 1
<br />6 THRU ANIT-CLIMB FENCE TO SECURED UNDER ANGLE
<br />SCALE: 1-1/2 =1 —0 SCALE: 1-1/2»=1'-0» RFoos COLUMN 1
<br />SHEAR SCREW FLUSH 1 ANGLE THAT SPANS
<br />AND GRIND SMOOTH FROM COLUMN TO
<br />COLUMN
<br />EXIST
<br />CONSTRUCTION q J-BOX
<br />1 N ! WHIP OFF JUNCTION BOX
<br />TO REMAIN
<br />ANTI -CLIMB FENCE SHOWN SHADED TRAFFIC UP TO LIGHT FIXTURE
<br />1 COATING, TYP RUNNING ALONG SIDE OF
<br />1 COLUMN
<br />1 MATCH EXISTING SLOPE EXIST _
<br />'CONC
<br />1 I
<br />ANGLE CANTILEVERS EXIST ROOF DRAINPIPING I I - COLUMN BEYOND
<br />FROM COLUMN, SEEMATCH
<br />EXISTING - STRUCTURAL w
<br />I I _j p
<br />r I I Z w
<br />a
<br />w °r
<br />\ —
<br />rn
<br />�\ \
<br />3
<br />a c 5------------ c� m
<br />MITER ANGLES GRIND
<br />£ 4 z 3Ki �
<br />ol
<br />I I SMOOTH
<br />VERIFY
<br />Aj
<br />2Y2" MTL STUD SOFFIT FRMG � 16" OC CONNECTION @ INSIDE CORNER FENCE CONNECTION @ CURB
<br />£
<br />W/ CEMENT BOARD STUCCO FINISHING $ » » RF005 ��, » RF003
<br />a SYSTEM SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 =1 —0
<br />w
<br />a SEALANT JT, TYP
<br />W
<br />CORE THROUGH EXISTING CONCRETE WALL W
<br />TO RE-ROUTE EXISTING ROOF DRAIN PIPING -
<br />SEE MECH FOR ADDL INFORMATION
<br />W
<br />NEW CURB & ANGLE CANTILEVER EXTERIOR SOFFIT z
<br />17 W
<br />» » RF017 13 » » EF001 j HORIZ MTL SIDING U
<br />J
<br />SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 =1 —0 I SYSTEM W/ J-TRIM 12" DIA ROLLER, ANGLE, Q
<br />ATTACHED TO HSS BEAM AND ATTACHMENT TO BE CJ
<br />DESIGN/BUILD BY
<br />jl CONTRACTOR W
<br />J u
<br />0
<br />N
<br />O
<br />OUTSIDE ENCLOSURE E Q
<br />11 (D
<br />INSTALL HINGE TO ALLOW
<br />I � j I HSS HORIZ. TOP AND Lu
<br />GATE TO SWING BEYOND 90' 1 VERTICAL POSTS, SEE o
<br />itI K STRUCTURAL U j
<br />2x2xY4" HSS GATE FRAMING I'l
<br />1 —— — Z
<br />ANTI —CLIMB FENCE
<br />11 I INTERMEDIATE 1 I I W :.{. Q
<br />1 TWO WAY KEYED LOCKABLE HORIZONTAL HSS BEAM 1 ATTACHMENT, CLOSURE 0 y
<br />N GATE LATCH 1 PLATE, UNISTRUT AND _ O m
<br />FENCING II MATCH EXISTING SLOPE F EN TO BE >
<br />1 j DESIGN/BUILD BY 00
<br />II ANGLE CANTILEVERS o (I I_- CONTRACTOR CY w/
<br />MATCH
<br />FROM COLUMN, SEE Ii
<br />STRUCTURAL 1
<br />EXISTING - 1
<br />I I I o f I
<br />MTL PANEL @ HORIZ & TOP FENCE CONNECTION @ HORIZ & TOP
<br />a a 9 , RF011 » , » RF008
<br />a SCALE: 1-1 /2» =1 —0» SCALE: 1-1 /2 =1 —0
<br />a
<br />a
<br />� HSS COLUMN ON THE BACKSIDE
<br />s m OF FENCE
<br />a a m EDGE TO ALIGN W/5" PLATE
<br />ABOVE ATTACHMENT, CLOSURE PLATE,
<br />UNISTRUT AND FENCING TO BE
<br />£/BUILD BY CONTRACTOR
<br />+ C C k
<br />.... _ INSIDE ENCLOSURE 15 LATTACHMENT, CLOSURE PLATE, I................ .............. ................ NAC
<br />UNISTRUT AND FENCING TO BE I ................:. :..: .:.:.. /� R C H I T E C T U R E
<br />d DESIGN BUILD BY I I .........:. . :.
<br />n g
<br />METAL PANEL / I I nacarchitecture.com
<br />CONTRACTOR
<br />t I
<br />....... 120 AVENUE
<br />3 WEST RIVERSIDE
<br />it SPOKANEWA99201
<br />..........
<br />I P 509 838 8240
<br />II ........... :....... :...
<br />I I...........
<br />NEW CURB & ANGLE SUPPORT GATE @ ANTI -CLIMB FENCE
<br />NAC NO 111-19089
<br />» , » RF018 4' » , » RF013 I I ....... DRAWN M P
<br />18 SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 =1 —0
<br />I I CHECKED
<br />.. .. ... .--
<br />.. .....
<br />MK
<br />.... ...... . ... _ . " DATE 3-
<br />I I .12 2021
<br />_................... ........... .
<br />I I I I I
<br />I I I
<br />I I
<br />ANGLE, SEE STRUCTURAL
<br />END OF PANELS
<br />CENTERED ON COLUMNS 3 ANGLE, SEE STRUCT
<br />DETAILS
<br />MTL PANEL GRIND SMOOTH
<br />ELEVATION @ METAL PANEL ELEVATION a@ FENCE CONNECTION CD
<br />10 » , » RF012 » , » RF007
<br />SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 -1 —0 z
<br />C) N A5*01
<br />
|