Laserfiche WebLink
.---------------------------------- REVISIONS <br />1�-------------� <br />HORIZ MTL SIDING t i -- - ---- _ <br />SYSTEM W/ J-TRIM <br />ATTACHED TO HSS _ L _ <br />ANTI -CLIMB FENCE AT COLUMN W/ 16 GA SHT F----- REMOVE EXISTING <br />GATE PANEL MTL CLIP ANGLES PIPE/METAL GRATE <br />PLATFORMS AND CONC. <br />ATTACH It THRU <br />2x2 ANGLE WRAPPING --`- ANIT-CLIMB FENCE TO PIER <br />EDGE OF COLUMN TO <br />SECURE FENCE COLUMN <br />- -- GRIND SMOOTH - FLUSH <br />TRAFFIC z5 <br />f k W/TOP OF CURB, TYP. <br />_ 2x2xY4" GATE FRAME COATING, TYP t° z <br />J <br />O — lz—Q m—— _ <br />Ira <br />z Orr „..a �. -h, ry. �S" ATTACHMENT, CLOSURE <br />8x%' CONT. PLATE FROM m � �� � <br />COLUMN TO COLUMN w x h K fi;k <br />FENCING TO BE <br />BETWEEN GATE POSTS m Q <br />c t DESIGN/BUILD BY k Via" <br />611 <br />CONTRACTOR" <br />COLUMN BEYOND <br />...:. <br />`x PLATE CONNECTION �\(�WjJ COLUMN DEMO j\/�Wj/ HORIZ GUARD RAIL <br />f 1 <br />3 <br />t $ S <br />k i <br />x. Y '1 <br />r. RF001 x. » RF004 » , » <br />z — — _ — — — <br />_,_ SCALE: 1 1 2 1 0 SCALE. 1 2 <br />_., r. .u,... ., .ti. .max ,... .. a z,.-,. .. fs .y ,....-.,...,. 4 ..*.. :F .:. ,. -. � , ...... ,; .-. iS,•:. �-€ ,..:: ,,..., <br />2x2x/4 ANGLE <br />,. <br />,�� LENGTH OF FENCING <br />ANTI —CLIMB FENCE <br />FENCE GATE @ SILL MTL PANEL CONNECTION @ CURB <br />15 SCALE: 1-1/2»=1'-0» RF014 SCALE: 1-1/2"=1'-0» RFo10 <br />- ANGLE THAT SPANS <br />1 FROM COLUMN TO <br />- COLUMN, SEE <br />WIRE FENCING <br />-- - - - - -- - -- - - -- STRUCTURAL <br />INTERIOR CLOSURE <br />PLATE BY TERMINATION BAR & <br />DESIGN/BUILD ANGLE SEALANT <br />CONTRACTOR 1 :, $ V, O, BASE FLASHING <br />BELOW — <br />_ �$ 5 � ADHERE TO HSS COLUMN <br />/ PIPE <br />OUTSIDE ENCLOSURE w 3 rvN NEW INSULATION AND <br />ANTI -CLIMB FENCE 3 EXISTING <br />2 U-Jw ROOFING TO MATCH <br />- - - -Q-°a---- - METAL PANEL I - � � � � £00* r � �� � r � BASE t ATTACHED TO <br />o a (E) CONC SLAB <br />w FLASH G <br />METAL PANEL c� m <br />BEL0 V- <br />CURB. a <br />j II BELOW <br />i <br />-- - <br />--- -- - METAL PANEL SECTIONS <br />\ REGISTERED <br />CENTERED 8'-0" COLUMNS 6135 <br />10, 7 CONNECTION @ OUTSIDE CORNER % COLUMN CONNECTION @ CURB ARCHITECT <br />ZD W / RF006 L » : » RF002 <br />m - SCALE: 1-1 /2» =1, —0» SCALE: 1-1 /2 =1 —0 �� <br />11 MICHAEL R. UMALLEY <br />STATE OF WASHINGTON <br />ANTI -CLIMB FENCE AND <br />INSIDE ENCLOSURE UNISTRUT TO BE DESIGN <br />CLOSURE PLATE, UNISTRUT AND 1 /BUILD BY CONTRACTOR <br />FENCE & METAL PANEL MTL PANEL OUTSIDE CORNER FENCING <br />ONS CTOR. ATTACHN/BUILD BY CONDUIT RUNNING AND <br />1 » , » RF015 1 <br />6 THRU ANIT-CLIMB FENCE TO SECURED UNDER ANGLE <br />SCALE: 1-1/2 =1 —0 SCALE: 1-1/2»=1'-0» RFoos COLUMN 1 <br />SHEAR SCREW FLUSH 1 ANGLE THAT SPANS <br />AND GRIND SMOOTH FROM COLUMN TO <br />COLUMN <br />EXIST <br />CONSTRUCTION q J-BOX <br />1 N ! WHIP OFF JUNCTION BOX <br />TO REMAIN <br />ANTI -CLIMB FENCE SHOWN SHADED TRAFFIC UP TO LIGHT FIXTURE <br />1 COATING, TYP RUNNING ALONG SIDE OF <br />1 COLUMN <br />1 MATCH EXISTING SLOPE EXIST _ <br />'CONC <br />1 I <br />ANGLE CANTILEVERS EXIST ROOF DRAINPIPING I I - COLUMN BEYOND <br />FROM COLUMN, SEEMATCH <br />EXISTING - STRUCTURAL w <br />I I _j p <br />r I I Z w <br />a <br />w °r <br />\ — <br />rn <br />�\ \ <br />3 <br />a c 5------------ c� m <br />MITER ANGLES GRIND <br />£ 4 z 3Ki � <br />ol <br />I I SMOOTH <br />VERIFY <br />Aj <br />2Y2" MTL STUD SOFFIT FRMG � 16" OC CONNECTION @ INSIDE CORNER FENCE CONNECTION @ CURB <br />£ <br />W/ CEMENT BOARD STUCCO FINISHING $ » » RF005 ��, » RF003 <br />a SYSTEM SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 =1 —0 <br />w <br />a SEALANT JT, TYP <br />W <br />CORE THROUGH EXISTING CONCRETE WALL W <br />TO RE-ROUTE EXISTING ROOF DRAIN PIPING - <br />SEE MECH FOR ADDL INFORMATION <br />W <br />NEW CURB & ANGLE CANTILEVER EXTERIOR SOFFIT z <br />17 W <br />» » RF017 13 » » EF001 j HORIZ MTL SIDING U <br />J <br />SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 =1 —0 I SYSTEM W/ J-TRIM 12" DIA ROLLER, ANGLE, Q <br />ATTACHED TO HSS BEAM AND ATTACHMENT TO BE CJ <br />DESIGN/BUILD BY <br />jl CONTRACTOR W <br />J u <br />0 <br />N <br />O <br />OUTSIDE ENCLOSURE E Q <br />11 (D <br />INSTALL HINGE TO ALLOW <br />I � j I HSS HORIZ. TOP AND Lu <br />GATE TO SWING BEYOND 90' 1 VERTICAL POSTS, SEE o <br />itI K STRUCTURAL U j <br />2x2xY4" HSS GATE FRAMING I'l <br />1 —— — Z <br />ANTI —CLIMB FENCE <br />11 I INTERMEDIATE 1 I I W :.{. Q <br />1 TWO WAY KEYED LOCKABLE HORIZONTAL HSS BEAM 1 ATTACHMENT, CLOSURE 0 y <br />N GATE LATCH 1 PLATE, UNISTRUT AND _ O m <br />FENCING II MATCH EXISTING SLOPE F EN TO BE > <br />1 j DESIGN/BUILD BY 00 <br />II ANGLE CANTILEVERS o (I I_- CONTRACTOR CY w/ <br />MATCH <br />FROM COLUMN, SEE Ii <br />STRUCTURAL 1 <br />EXISTING - 1 <br />I I I o f I <br />MTL PANEL @ HORIZ & TOP FENCE CONNECTION @ HORIZ & TOP <br />a a 9 , RF011 » , » RF008 <br />a SCALE: 1-1 /2» =1 —0» SCALE: 1-1 /2 =1 —0 <br />a <br />a <br />� HSS COLUMN ON THE BACKSIDE <br />s m OF FENCE <br />a a m EDGE TO ALIGN W/5" PLATE <br />ABOVE ATTACHMENT, CLOSURE PLATE, <br />UNISTRUT AND FENCING TO BE <br />£/BUILD BY CONTRACTOR <br />+ C C k <br />.... _ INSIDE ENCLOSURE 15 LATTACHMENT, CLOSURE PLATE, I................ .............. ................ NAC <br />UNISTRUT AND FENCING TO BE I ................:. :..: .:.:.. /� R C H I T E C T U R E <br />d DESIGN BUILD BY I I .........:. . :. <br />n g <br />METAL PANEL / I I nacarchitecture.com <br />CONTRACTOR <br />t I <br />....... 120 AVENUE <br />3 WEST RIVERSIDE <br />it SPOKANEWA99201 <br />.......... <br />I P 509 838 8240 <br />II ........... :....... :... <br />I I........... <br />NEW CURB & ANGLE SUPPORT GATE @ ANTI -CLIMB FENCE <br />NAC NO 111-19089 <br />» , » RF018 4' » , » RF013 I I ....... DRAWN M P <br />18 SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 =1 —0 <br />I I CHECKED <br />.. .. ... .-- <br />.. ..... <br />MK <br />.... ...... . ... _ . " DATE 3- <br />I I .12 2021 <br />_................... ........... . <br />I I I I I <br />I I I <br />I I <br />ANGLE, SEE STRUCTURAL <br />END OF PANELS <br />CENTERED ON COLUMNS 3 ANGLE, SEE STRUCT <br />DETAILS <br />MTL PANEL GRIND SMOOTH <br />ELEVATION @ METAL PANEL ELEVATION a@ FENCE CONNECTION CD <br />10 » , » RF012 » , » RF007 <br />SCALE: 1-1 /2 =1 —0 SCALE: 1-1 /2 -1 —0 z <br />C) N A5*01 <br />