My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
7 ELEVEN
>
Plans
>
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 11:20:51 AM
Creation date
10/24/2022 10:23:53 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
7 ELEVEN
Permit
B2008-029
Year
2020
Notes
CREATE RETAIL SPACES IN THE FORMER CONVENIENCE STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING ROOF - <br />STRUCTURE ABOVE <br />3-5/8" x 20 GA. BRACE <br />AT EACH JOIST <br />3-5/8" x 20 GA. —" <br />STUDS AT 24" O.C. <br />METAL RUNNER CHANNEL <br />12 <br />— FASTEN RUNNER TO BOTTOM. <br />9 OF STRUCTURE W/2 #6 TEK <br />1 7 SCREWS @ 24" O.0 <br />A 'o <br />7 <br />SIW <br />PAINTED GYP., REFERENCE <br />PAINTING SCHEDULE <br />FINISH PER ROOM FINISH <br />"'���SCHEDULE AND INTERIOR <br />ELEVATIONS <br />BULLNOSE TILE EDGE (T-5) <br />A.F.F. <br />REFER TO RCP <br />I pgh, I I <br />I oil <br />olm <br />10'-2 1/2" <br />REFLECTED CEILING PLAN (ez <br />3/16" = l'-O" NORTH <br />-I\- -/\\- _/\_ <br />m <br />9 <br />GENERAL NOTES <br />1 . ALL WALL PAINT ABOVE 9'-4" IN THE MERCHANDISE AREA SHALL BE "P-4" UNLESS NOTED <br />OTHERWISE ON THE REFLECTED CEILING PLAN. (REFERENCE SHEET A6.1 FOR MATERIALS <br />SCHEDULE). <br />2. SYRUP LINE INSTALLATION NOTE: WHERE REQUIRED BY CODE OR AS INDICATED ON PLAN <br />CABLED BUNDLE SYRUP LINES SHALL BE INSTALLED IN PVC CONDUIT (METAL CONDUIT <br />FOR FR LINES) W/ 45 DEGREE SWEEPS AT CORNER AND "TEE" CONNECTIONS, CONDUIT <br />SHALL BE ATTACHED TO WALL AND UNDERSIDE OF ROOF CONSTRUCTION W/ PIPE STRAPS <br />AS REQUIRED, REFERENCE MANUFACTURE SPECIFICATIONS FOR MINIMUM ALLOWED <br />BENDING RADIUS OF LINES <br />3. VERIFY NUMBER OF SYRUP LINES TO NUMBER OF SYRUP AND POST MIX MACHINES <br />4. PROVIDE ACCESS PANEL WHEN EQUIPMENT IS PRESENT ABOVE COOLER VAULT <br />k2 � J� <br />10'-5". 510" _Ll <br />--------------- <br />PROVIDE UNISTRUT PlOOO ACROSS <br />THREE TRUSSES MIN. TO <br />ACCOMMODATE NEW MONITORS <br />12 <br />Eli <br />NOTE: <br />PROVIDE BLOCKING AS REQUIRED FOR <br />ALL CEILING MOUNTED COMPONENTS <br />110 <br />lil REFLECTED CEILING PLAN KEY NOTES <br />1. SYRUP LINE 974 SERIES (974R AT FIRE RATED WALLS) ATTACHED TO BOTTOM OF DECK <br />WITH Y4" WIDE 16 GAUGE GALVANIZED PIPE STRAPS AT4'O.C. <br />2. 6" DIA PVC CONDUIT ABOVE CEILINGS FOR SYRUP LINES -ROUTE (2) BUNDLES OF 14 <br />SYRUP LINES PER 6" PVC CONDUIT AS REQUIRED -SEAL TO WALL FINISH AT <br />PENETRATIONS AND APPLY SPRAY FOAM ON INTERIOR OF CONDUIT AT ENDS TO SEAL <br />AROUND SYRUP LINES (TYP THROUGHOUT WALLS). <br />3. SYRUP LINES TO POSTMIX INSTALL IN PVC CONDUIT TO WALL POCKET BELOW AND SEAL <br />AS REQUIRED. <br />4, SYRUP LINES TO SLURPEE DISPENSERS INSTALL IN PVC CONDUIT TO WALL POCKET <br />BELOW AND SEAL AS REQUIRED. <br />5. NOT USED. <br />6. NOT USED. <br />7. PRE -MANUFACTURED INSULATED COOLER VAULT CEILING. BUILDING CEILING ABOVE Is <br />UNFINISHED EXPOSED STRUCTURE, <br />8. DIGITAL MENU BOARDS, REF EF-1, A7.2, AND A7.3 FOR MORE DETAILS, G.C. TO INSTALL <br />DMB AS TIGHT AS POSSIBLE TO UNDERSIDE OF A.C.T. CEILING TO MAINTAIN MAXIMUM <br />' C'To I NSTALL <br />AIN MAXIMUM <br />CLEARANCE, 6'-8" A.F.F. MIN, <br />9. PROMO SCREEN. CENTER BETWEEN POS1 AND POS2. REF EF-1, A7.2, AND A7.3 FOR <br />3 <br />MORE DETAILS. GC TO INSTALL DNAB AS TIGHT AS POSSIBLE TO UNDERSIDE OF A.C.T. <br />CEILING TO MAINTAIN MAXIMUM CLEARANCE, 6'-8" A.F.F. MIN, <br />10. NEW HVAC UNIT. REFER TO MECHANICAL DRAWINGS FOR FURTHER INFORMATION. <br />11. NEW 7-ELEVEN SIGNAGE TO BE PERMITTED AND INSTALLED BY OTHERS. <br />'rl2. NEW LED FIXTUR`ESMC�UNTED TO UNDERS�IDEOF �EXIST`INC�' CA�NOPY. <br />Ing <br />EXISTING ROOF <br />STRUCTURE ABOVE <br />FASTEN RUNNER TO <br />BOTTOM OF STRUCTURE <br />W/2 #6 TEK SCREWS @ <br />24" O.C. <br />3 5/8" 20GA. METAL STUD <br />KICKER @ 16" O.C. TO <br />UNDERSIDE OF <br />STRUCTURE <br />B/ EX. WOOD TRUSS <br />\,r + 8'-1 0" A. F. F. <br />A%f--\ B/ SCHEDULED CLG. <br />REFER TO RCP <br />3 5/8" 20GA. METAL <br />STUDS @ 16" O.C. TO <br />UNDERSIDE OF <br />STRUCTURE <br />METAL CORNER BEAD, <br />ALL SIDES, TYP. <br />REFLECTED CEILING PLAN SYMBOLS <br />(NOT ALL SYMBOLS MAY BE USED) <br />ROOM HEIGHT ABOVE FINISH TAG CEILING TAG <br />FINISH FLOOR (REFER TO MATERIAL (REFER TO CEILING <br />SCHEDULE) SCHEDULE ON THIS <br />CONCENTRIC DIFFUSER <br />F71AIR DIFFUSER <br />CEILING <br />EXHAUST <br />TRANSFER <br />GRILL <br />EMERGENCY <br />LIGHT FIXTURE <br />REF. ELECTRICAL <br />SECURITY MONITOR <br />`Af/BUILT IN CAMERA <br />SECURITY CAMERA <br />EXIT SIGN DIRECTIONAL <br />EXIT SIGN <br />ISUSPENDED <br />CEILING GRID <br />(A-1) <br />::� Sim. <br />Z_(A7�0) <br />4/// <br />/Z <br />co <br />4 7/8'[ <br />T-6" MIN. <br />PROVIDE CLEAR AREA <br />ABOVE AND AROUND <br />POST-M IX TO ALLOW TO <br />MAINTENANCE ACCESS <br />GC TO VERIFY FINAL CEILING <br />HEIGHT AND CLEAR AREA <br />ARCOU�NDP �T-MIX IN FIELD <br />0 4 <br />N.T.S. <br />METAL TOP TRACK <br />EXISTING PRE-ENGINEERED <br />WOOD TRUSSES @ 24 O.C, <br />TO REMAIN <br />VERIFY AS REQUIRED TO <br />CLEAR TOP OF ICE <br />MACHINE <br />5/8" GYP. BID. ON 3 5/8" <br />20GA. METAL STUDS @ <br />16" 0. C. <br />WALL PARTITION <br />- SEE PLAN AND <br />PARTITION TYPE <br />SHEET) <br />F77777771 <br />�:�l GYP BOARD CEILING <br />EZZI WALK IN COOLER <br />EVAPORATOR <br />LED LIGHT <br />REF. ELECTRICAL <br />EMERGENCY LED <br />LIGHT FIXTURE <br />REF. ELECTRICAL <br />LED LIGHT <br />FIXTURE <br />REF, ELECTRICAL <br />SURFACE MOUND <br />I LED LIGHT <br />FIXTURE <br />REF. ELECTRICAL <br />2x2 LED <br />EMERGENCY <br />LIGHT FIXTURE <br />REF. ELECTRICAL <br />2x2 LED <br />LIGHT FIXTURE <br />REF. ELECTRICAL <br />INTERIOR WALL MOUNT <br />SPEAKER <br />AWA MUSIC SYSTEM <br />L# REVISIONS <br />NO. DATE � DESCRIPTION <br />1 11/04/20 JOWNER/PEER REVIEW COMMENTSI <br />CONSULTANT <br />1 1 � <br />SEAL <br />7862 <br />v" F R E_ G I S 'T �Er--_"IRE D <br />IN- '_ IT" <br />CUSTOMER <br />lilma-mrs; wwim��_ - moommomm <br />PROJECT DESCRIPTION <br />STORE # <br />SHEET TITLE <br />CEILING <br />PLAN <br />SHEET MANAGEMENT <br />PROJECT NO,: 41564 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: FS DA <br />REVIEWED BY: JK/JD <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN RESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENTWITI OUTTHE EXPRESSEI <br />WRITTEN, PERMISSION OF SEVAN DESIGN SOLUTIONS, P.C, IS PROHIBITED. <br />(NOTPUBUSHED: ALL RIGHIS RESERVED.) <br />COPYRIGHT BYSEVAN DESIGN SOLUTIONS, P.C. 2020 <br />, NO <br />I <br />
The URL can be used to link to this page
Your browser does not support the video tag.