Ill�nl � r <br />NOTE: <br />DETAIL ELIMINATES PITCH POCKETS <br />FOR PIPING PENETRATIONS THROUGH <br />THE ROOF. PITCH POCKET <br />INSTALLATIONS ARE PROHIBITED. <br />ATTACHED TREATED WOOD NAILER <br />TO DECK WITH SUITABLE FASTNER AS <br />REQ'D PER LOCAL AHJ. <br />PROVIDE MINI 2° BETWEEN <br />PIPES AND 4" MIN CLEARANCE <br />FROM PIPE TO TOP OF CURES. <br />z <br />yF- <br />U <br />Q <br />ca <br />la W <br />INSULATE VOID AS <br />REQ'D TO PREVENT <br />CONDENSATION <br />PIPE PORTAL <br />1 1 /2" = V-0" <br />DEMISING LINE <br />(ROOF PLAN <br />D3/16" 6 V-0" <br />SHEET METAL OR FLEX TUBE COLLAR. <br />PROVIDE CONT, BEAD OF SEALANT AT COLLAR <br />SHEET MTL FLASHING RECEIVER WITH <br />GASKETED FASTENERS @ MIN 18" O.C. AROUND <br />PERIMETER OF PIPE PORTAL.; PROVIDE PROPER <br />_ FASTENING SCHEDULE AS REQ'D PER LOCAL <br />AH.J. <br />REMOVABLE COUNTER FLASHING <br />OVER FASTNERS @ 8" O.C. <br />ROOFING MEMBRANE TO EXTEND <br />MIN OF 2" ABOVE CANT <br />SINGLE PLY ROOFING MEMBRANE OVER LAP <br />FLASHING AS REQ'D PER ROOFING MEMBRANE <br />SPECIFICATIONS <br />THERMAL INSULATION <br />WOOD CANT AS REQ'D TO BRACE CURB <br />— — — — — — <br />�---- --- ROOF DECK <br />00 <br />f <br />1. REMOVE ANY UNUSED EXHAUST FAN, DUCTWORK, FLUES, VENTS, AND EXISTING <br />CONDENSING UNITS. FIELD VERIFY EXISTING EQUIPMENT LAYOUT. PATCH AND <br />REPAIR ROOF TO MATCH EXISTING CONDITION. <br />AND CONTRACTOR <br />TO <br />INSPECTPATCH/REPAIREXIST. <br />EXIST ROOF MEMBRANE, FLASHING, ETC. AS 1 FOR A COMPLETE AND <br />WATERTIGHTi <br />1 II <br />1. EXISTING ROOF TOP EQUIPMENT TO BE REMOVED IN ITS ENTIRETY. CURS TO <br />REMAIN, CLOSE OFF EXIST OPENING W/GALV. MTL COVER OVER-" EXT, GRADE <br />PLYWOOD SUBSTRATE. <br />2. NEW ROOF TOP UNIT. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR <br />FURTHER INFORMATION. <br />3. NEW REMOTE CONDENSER. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS <br />FOR FURTHER INFORMATION. <br />4. NEW EXHAUST DUCT. REFER TO MECHANICAL DRAWINGS FOR FURTHER <br />INFORMATION. <br />5. NEW SANITARY VENT THRU ROOF. REFER TO PLUMBING DRAWINGS FOR FURTHER <br />INFORMATION. <br />6. EXISTING METAL COPING TO REMAIN. <br />7. LINE OF EXISTING EXTERIOR WALL ASSEMBLY BELOW. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 ' <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI4 331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCE_LIENCE I CHARITY <br />REVISIONS NO. I DATE I DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />II CONSULTANT II <br />SEAL <br />EGIS r <br />ARCHITECT <br />}D <br />A IMSF <br />i, <br />W <br />CUSTOMER <br />PROJECT DESCRIPTION <br />I I PROJECT LOCATION <br />607 SE EVERETT MALL <br />WAY <br />SLEET TITLE <br />EXISTING'ROOF <br />PLAN <br />SHEET MANAGEMENT <br />PROJECT NO.: 41504 <br />DATE ISSUED: 0-03-20 <br />DRAWN BY: FS/OA <br />REVIEWED BY: JK/J0 <br />THIS DOCUMENT IS AND SHALL REMAIN TILE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT W ITHOUTTHE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN DESIGN SOLUTIONS, P.C. 20)0 <br />SHEET NUMBER <br />