EXISTING WALL <br />ASSEMBLY TO REMAIN <br />INSIDE <br />OUTSIDE <br />B.O. EXISTING ROUGH <br />OPENING - V.I.F. <br />-- INSTALL NEW 2x WOOD TOP <br />EXISTING WALL <br />ASSEMBLY TO REMAIN <br />` INFILL EXISTING ROUGH <br />OPENING AS REQUIRED TO <br />MATCH EXISTING WALL <br />CONSTRUCTION AND <br />NEW WALL FINISH <br />ADJACENT EXTERIOR <br />- REFER TO MATERIALS <br />FINISH MATERIAL <br />SCHEDULE FOR <br />FURTHER <br />INSTALL NEW 2x WOOD <br />INFORMATION <br />BOTTOM PLATE <br />NEW WALL BASE <br />- REFER TO MATERIALS <br />T.O. EXISTING ROUGH kL <br />SCHEDULE FOR <br />OPENING -V.I.F. <br />FURTHER <br />EXISTING WALL ASSEMBLY <br />INFORMATION <br />TO REMAIN <br />NEW FLOOR FINISH <br />- REFER TO MATERIALS <br />SCHEDULE FOR <br />FURTHER <br />INFORMATION <br />a <br />T.O. EXISTING PARAPE <br />14'-3" V.L.F. <br />T.O. EXISTING STOREFI <br />6 10" V.I.F. <br />PAINT COLOR TRANSITI <br />2°_0" V.I.F. <br />T.O. FINISH FLOOR <br />Moll - <br />If- T .O. EXISTING PARAPE <br />14 3" V.I.F. <br />T.O. EXISTING STOREF <br />I <br />6'-10" V.I.F. <br />PAINT COLOR TRANSIT <br />2-0" V.I.F. <br />T.O. FINISH FLOOR <br />0`-Oil <br />r <br />PER MANUFACTURE'S <br />SPECIFICATIONS <br />EXISTING CONTINUOUS <br />SOFFIT VENT <br />EXISTING BUILDING SOFFIT <br />FACE OF OVERHANG MANTEL <br />� Ya <br />®If <br />NEV140"ALUMINUM <br />BUILTTO Y <br />f BLOCKING TO <br />EXISTING • • DECK AT TRUSS <br />flLOCATIONS <br />`- FASCIA TO OVERLAP CLADDING BY 1 <br />1/2" MIN. <br />/® CEMENT FIBER NICHIHA CLADDING <br />PANELS OVER VERTICAL FRAMING <br />CHANNELS (CHANNEL AND FRAMING <br />CHANNELS AND CLADDING BY NICHIA, <br />SYSTEM INSTALLED BY G.C. <br />CONTINUOUS HORIZONTAL 1x4 <br />/ PRESSURE TREATED FURRING <br />OVERHANG STRUCTURE.TYP. <br />TOP, MID -HEIGHT AND BOTTOM - 4"-0" <br />O.C. MAX. ADJUST SPACING OR ADD <br />FURRING AS REQUIRED <br />�- FACE OF OVERHANG <br />`- FLUID APPLIED WEATHER BARRIER <br />OVER EXISTING OVERHANG MATERIAL <br />(W.R. MEADOWS AIR SHIELD T MP <br />- CONTINUOUS METAL DRIP EDGE <br />FLASHING ATTACHED TO FACE OF <br />EXISTING OVERHANG VERTICAL LEG <br />TO BE 3" HIGH. SET FLASHING <br />AGAINST WALL WITH A CONTINUOUS <br />BEAD OF SILICONE SEALANT <br />TOTAL SYSTEM THICKNESS ±2 3/4" <br />EXTERIORT9ONS LEGEND <br />ELEVATIONS KEY NOTES <br />1. <br />NEW ALUMINUM STOREFRONT DOOR, FINISH TO MATCH EXISTING. REFER TO SHEET A6.0 <br />DOOR SCHEDULE FOR FURTHER INFORMATION. <br />X <br />SECTION TAG <br />A3.0 <br />2. <br />NEW INTERNALLY ILLUMINATED WALL SIGN BY OTHERS UNDER SEPARATE PERMIT. <br />g <br />B <br />3. <br />INFILL A/C UNIT OPENING. PATCH AND REPAIR TO MATCH EXISTING EXTERIOR WALL <br />ASSEMBLY. PAINT EXTERIOR WALL FINISH P-1 <br />4. <br />EXTERIOR CO2 CAGE. <br />5. <br />NITROGEN CAGE. <br />KEYNOTE <br />6. <br />PROPANE EXCHANGE CAGE BY <br />PROVIDED THIRD PARTY. <br />7. <br />ICE MERCHANDISER. <br />8. <br />NEW 7-ELEVEN WINDOW STRIPING APPLIED TO INSIDE FACE OF GLASS. <br />P- # PAINT <br />9. <br />NEW BLACK WINDOW FILM TO BE INSTALLED AT BOTTOM OF TOP MULLION TO TOP OF <br />(SEE A6.1 EXTERIOR <br />WINDOW STRIPE, AND RUN ACROSS STOREFRONT AT SAME LEVEL AS SHOWN. <br />PAINT SCHEDULE.) <br />10. <br />BEGIN NEW BLACK WINDOW FILM WHERE INDICATED. TO BE ALIGNED WITH BEGINNING OF <br />SALES COUNTER. <br />11. <br />EXISTING METAL COPING TO BE PAINTED P-1. SEE SHEET A6.1 FOR EXTERIOR PAINT <br />SCHEDULES. <br />12. <br />NEW ALUMINUM COMPOSITE METAL PANEL (ACM). <br />13. <br />EXISTING EXTERIOR FINISH TO BE PAINTED P-1. SEE SHEET. A6.1 FOR EXTERIOR PAINT <br />SCHEDULES. <br />14. <br />EXISTING EXTERIOR FINISH TO BE PAINTED P-2. SEE SHEET A6.1 FOR EXTERIOR PAINT <br />SCHEDULES. <br />15. <br />EXISTING METAL CONTAINER TO REMAIN. <br />16. <br />EXISTING PLANTER TO REMAIN. <br />17, <br />EXISTING TRASH CAN TO REMAIN. <br />18. <br />EXISTING METAL COPING TO REMAIN. NO WORK. <br />19, <br />EXISTING STUCCO FINISH TO REMAIN. NO WORK. <br />20, <br />EXISTING CORRUGATED METAL CANOPY TO REMAIN. <br />21. <br />NEW EMERGENCY EGRESS LIGHT <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove® IL 60515 <br />Phone:312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, Ml48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />Z REVISIONS <br />K L DA I E DESCRIPTIOIN <br />1 1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />CONSULTANT <br />SEAL <br />7862 <br />[k <br />. <br />' <br />#� <br />3. GyS y��- &w ¢� <br />I'E ,., d I € ^ E,. E L Cw..�� <br />F , G i I `E <br />EC T <br />€ i OF VVIAS 191 <br />CUSTOMER <br />I PROJECT DESCRIPTION <br />1 <br />PROJECT LOCATION <br />607 SE EVERETT MALL <br />WAY <br />SHEET TITLE <br />EXTERIOR <br />ELEVATIONS <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: P5/0A <br />REVIEWED BY: JK/JD <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT WITHOUTTHE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN DESIGN SOLUTIONS, P.C. 2020 <br />I I SHEET NUMBER I I <br />