<br />1. SCOPE
<br />1.1 HEREAFTER IN THIS SPECIFICATION, THE WORD "MECHANICAL CONTRACTOR" SHALL REFER TO THE
<br />INSTALLING MECHANICAL OR REFRIGERATION CONTRACTOR AND "OWNER" SHALL REFER TO 7-ELEVEN. OWNER
<br />SHALL PURCHASE THE EQUIPMENT AND ARRANGE TO HAVE THAT EQUIPMENT DELIVERED TO THE STORE SITE. THE
<br />MECHANICAL CONTRACTOR SHALL HAVE THE UPRIGHT REFRIGERATED CABINETS UNCRATED, SET IN PLACE, LEGS
<br />INSTALLED, UPRIGHT REFRIGERATED CABINETS LEVELED, PLACE THE CONDENSING UNITS, MAKE CONNECTIONS
<br />FOR THE REFRIGERATION LINES AND ELECTRICAL LINES (WHERE ALLOWED BY LOCAL CODE) BETWEEN THE
<br />UPRIGHT REFRIGERATED CABINETS AND CONDENSING UNITS, FURNISH AND INSTALL THE CONDENSATE DRAIN
<br />LINES AND START UP THE UNITS PER THE INSTALLATION INSTRUCTIONS PACKAGED WITH THE EQUIPMENT. POWER
<br />WIRING FROM THE ELECTRICAL PANEL TO THE UPRIGHT REFRIGERATED CABINETS iS THE RESPONSIBILITY OF THE
<br />GENERAL CONTRACTOR'S ELECTRICAL SUB -CONTRACTOR.
<br />2. CODE REQUIREMENTS
<br />2.1 ALL PROPOSALS SHALL INCLUDE, AND WORK PERFORMED SHALL BE ACCOMPLISHED IN ACCORDANCE
<br />WITH APPLICABLE LOCAL LAWS, REGULATIONS, ORDINANCES, STATUTES AND CODES, WHICH SHALL BE
<br />DELINEATED, AND ALL MODIFICATIONS REQUIRED BY THE INSPECTING AUTHORITY SHALL BE MADE BY THE
<br />MECHANICAL CONTRACTOR WITHOUT ADDITIONAL COST TO THE OWNER. ANY DEVIATIONS REQUIRED DUE TO
<br />UNFORESEEN CIRCUMSTANCES, SHALL BE CALLED TO THE ATTENTION OF THE PROJECT CONSTRUCTION MANAGER.
<br />3. GUARANTEE
<br />3.1 MECHANICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND THE COMPLETE SYSTEM OPERATION
<br />WILL BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL THAT THE MECHANICAL CONTRACTOR PROVIDED
<br />FOR INSTALLATION, FOR A PERIOD OF 90 DAYS AFTER ACCEPTANCE BY THE OWNER. ANY PART OF THE
<br />FURNISHED EQUIPMENT ON THIS INSTALLATION WHICH PROVES DEFECTIVE, OR WAS DAMAGED IN SHIPMENT,
<br />SHALL BE HANDLED AS STATED IN PARAGRAPH 4 ENTITLED "MECHANICAL CONTRACTOR INSPECTION
<br />RESPONSIBILITIES".
<br />3.2 MECHANICAL CONTRACTOR SHALL GUARANTEE THAT THE UNIT HAS BEEN INSTALLED PROPERLY.
<br />3.3 MECHANICAL CONTRACTOR SHALL PROVIDE THE FOLLOWING INFORMATION TO THE EQUIPMENT
<br />MANUFACTURER'S DISTRIBUTOR, AND TO THE OWNER IF DEFECTS ARE ENCOUNTERED WITH THE EQUIPMENT.
<br />3.3.1 MODEL NUMBER OF THE UNIT.
<br />3.3.2 SERIAL NUMBER OF THE UNIT.
<br />3.3.3 DATE OF INSTALLATION
<br />3.3.4 DETAILED ACCOUNT OF THE PROBLEM, DIAGNOSIS, AND REPAIR WORK REQUIRED.
<br />3.3.5 PARTS REQUIRING REPLACEMENT.
<br />3.3.6 STORE NUMBER AND ADDRESS.
<br />3.4 MECHANICAL CONTRACTOR SHALL FURNISH TO THE OWNER'S REPRESENTATIVE ALL CERTIFICATES OF
<br />FINAL INSPECTION AND APPROVAL FROM INSPECTION AUTHORITIES HAVING JURISDICTION.
<br />WALK IN COOLERREFRIGERATION SYST INSTALLATION
<br />SPECIFICATION INTRODUCTION:
<br />THE CONTRACTING FOR INSTALLATIONS OF WALK-IN REFRIGERATION EQUIPMENT WILL BE ACCOMPLISHED IN
<br />THE FIELD AT THE ZONE LEVEL. THESE SPECIFICATIONS ARE TO AID IN PREPARATION OF NATIONAL
<br />STANDARD CONTRACT DOCUMENTS.
<br />I. SCOPE
<br />NUNN
<br />t }
<br />3 A tir � ♦■ �
<br />2. CODE REQUIREMENTS AND PERMITS
<br />2.1 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH ALL APPLICABLE LOCAL LAWS,
<br />REGULATIONS, ORDINANCES, STATUTES AND CODES, AND ALL MODIFICATIONS REQUIRED BY THE INSPECTION
<br />AUTHORITY SHALL BE MADE BY THE MECHANICAL CONTRACTOR WITHOUT ADDITIONAL COST TO THE OWNER.
<br />2.2 OBTAIN, PAY FOR AND FURNISH ALL REFRIGERATION PERMITS REQUIRED BY LOCAL OR STATE
<br />ORDINANCES OR CODES.
<br />2.3 NO EXTRAS SHALL BE ALLOWED DUE TO CONDITIONS WITH WHICH THE MECHANICAL CONTRACTOR
<br />SHOULD HAVE BEEN FAMILIAR.
<br />3. GUARANTEE
<br />3.1 MECHANICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND THE COMPLETE SYSTEM OPERATION
<br />WILL BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL THAT THE MECHANICAL CONTRACTOR
<br />PROVIDED FOR INSTALLATION, FOR A PERIOD OF 90 DAYS AFTER ACCEPTANCE BY THE OWNER. ANY PART OF
<br />THE FURNISHED EQUIPMENT ON THIS INSTALLATION WHICH PROVES DEFECTIVE, OR WAS DAMAGED IN
<br />SHIPMENT, SHALL BE HANDLED AS STATED IN PARAGRAPH 4 ENTITLED "MECHANICAL CONTRACTOR INSPECTION
<br />RESPONSIBILITIES".
<br />3.2 MECHANICAL CONTRACTOR SHALL FURNISH TO THE OWNER REPRESENTATIVE ALL CERTIFICATES OF
<br />FINAL INSPECTION AND APPROVAL FROM INSPECTION AUTHORITIES HAVING JURISDICTION.
<br />4. MECHANICAL CONTRACTOR INSPECTION RESPONSIBILITIES
<br />4.1 CHECK EACH PIECE OF REFRIGERATION EQUIPMENT FOR DAMAGES AND SHORTAGES. IF SUCH
<br />CONDITIONS EXIST, THE MECHANICAL CONTRACTOR SHALL:
<br />4.1.1 OBTAIN INSPECTION REPORT IN DUPLICATE FROM THE COMMON CARRIER AND NOTIFY OWNER
<br />OFFICE AND REFRIGERATION EQUIPMENT SUPPLIER IMMEDIATELY.
<br />4.1.2 MAKE REPAIRS WHEN AUTHORIZED TO DO SO BY MANUFACTURER'S REPRESENTATIVE,
<br />REPLACING ANY MALFUNCTIONING PART(S) ON THE EQUIPMENT WITHOUT CHARGE TO THE OWNER.
<br />5. EQUIPMENT
<br />5.1 EVAPORATOR FAN COILS
<br />THE MECHANICAL CONTRACTOR SHALL HANG THE EVAPORATOR COILS IN ACCORDANCE WITH THE MECHANICAL
<br />PLAN. ALL MOUNTING HARDWARE, TO INCLUDE A BEARING SURFACE FOR THE HANGER RODS, SHALL BE
<br />FURNISHED BY THE MECHANICAL CONTRACTOR. THE EVAPORATOR FAN COILS ARE IN NO CIRCUMSTANCE TO BE
<br />SUPPORTED BY THE WALK-IN COOLER PANELS ALONE.
<br />5.2 APPROVED COOLER (VAULT) REFRIGERATION EQUIPMENT MANUFACTURERS AND MODEL NUMBERS
<br />(R448A)
<br />5.2.1 HEATCRAFT/BOHN REMOTE CONDENSING UNITS INCLUDING (1) MEDIUM TEMP COMPRESSOR FOR
<br />VAULT COOLER, (1) LOW TEMP COMPRESSOR FOR VAULT ICE STORAGE, AND (1) LOW TEMP COMPRESSOR FOR
<br />VAULT FREEZER STORAGE.
<br />6. INSTALLATION REQUIREMENTS
<br />6A REFRIGERANT PIPING
<br />6A.1 ALL SUCTION LINE PIPING SHALL BE SEALED REFRIGERANT GRADE, TYPE L, HARD DRAWN. THE
<br />LIQUID LINE PIPING SHALL BE SEALED REFRIGERANT GRADE, TYPE C, HARD DRAWN ON ALL MAIN RUNS.
<br />THE SHORT SECTION OF TUBING BETWEEN THE MAIN LIQUID LINE AND EXPANSION VALVE SHALL BE SOFT
<br />DRAWN REFRIGERANT TUBING.
<br />6.1.2 ALL HORIZONTAL TUBING RUNS SHALL BE SLOPED TOWARD THE COMPRESSOR, AND/OR "P"
<br />TRAP 1 INCH PER 20 FEET. ALL VERTICALLY RUN SUCTION LINES SHALL BE P-TRAPPED AT THE BASE OF
<br />EACH SUCTION RISER OF 4 FEET OR MORE TO ENHANCE OIL RETURN TO THE COMPRESSOR, AND SHALL BE
<br />P-TRAPPED FOR EACH 20 FEET SECTION OF RISER,
<br />6.1.3 ONLY SILVER BASE SOLDER (15% SILVER) SHALL BE USED FOR THIS INSTALLATION.
<br />6.1.4 REFRIGERANT PIPING IN THE WALK-IN SHALL BE STRAPPED TO ASSURE PIPING SUPPORT. THIS
<br />STRAPPING SHALL BE COPPER. IF NON -COPPER STRAPPING IS USED, IT SHALL BE LINED WITH AN
<br />INSULATING MATERIAL TO PREVENT BI-METALLIC ELECTROLYSIS. REFER TO MANUFACTURER'S
<br />INSTALLATION MANUAL FOR RECOMMENDED PIPE SUPPORT SPACING.
<br />6.2 REFRIGERANT LEAK TESTING
<br />6.2.1 AFTER ALL REFRIGERANT TUBING IS CONNECTED, THE ENTIRE SYSTEM, INCLUDING THE
<br />CONDENSING UNIT, SHALL BE PRESSURIZED TO 150 PSIG WITH A MIXTURE OF APPROPRIATE REFRIGERANT
<br />AND DRY NITROGEN. ALL CONNECTIONS, BOTH FLARED AND SOLDERED, SHALL BE THOROUGHLY
<br />CHECKED WITH AN ELECTRONIC OR HALIDE LEAK DETECTOR. ALL LEAKING SOLDER CONNECTIONS SHALL
<br />BE DISASSEMBLED, CLEANED AND RE -SOLDERED.
<br />6.3 EVACUATION
<br />6.3.1 THE COMPLETE SYSTEM SHALL BE EVACUATED WITH A VACUUM PUMP. THE REFRIGERATION
<br />COMPRESSOR SHALL NOT BE USED TO EVACUATE THE SYSTEM.
<br />6.3.2 THE COMPLETE SYSTEM, TO INCLUDE THE CONDENSING UNIT, SHALL BE EVACUATED A
<br />MINIMUM OF THREE TIMES. THE VACUUM SHALL BE BROKEN THE FIRST AND SECOND TIME AT 500 MICRONS
<br />USING APPROPRIATE REFRIGERANT. THE THIRD VACUUM SHALL BE BROKEN BY THE CHARGING
<br />REFRIGERANT.
<br />6A SUCTION LINE INSULATION
<br />6.4.1 THE MAIN SUCTION LINE INSIDE THE COOLER (VAULT) TO INCLUDE THE "'P" TRAP, THE VERTICAL
<br />SUCTION RISER, ALL ABOVE ROOF SUCTION PIPING SHALL BE INSULATED WITH 1/2" WALL ARMAFLEX OR ITS
<br />EQUIVALENT. ALL JOINTS SHALL BE PROPERLY SEALED WITH APPROVAL BY INSULATION MANUFACTURER'S
<br />ADHESIVE OR SEALANT.
<br />6.5 CONDENSATE DRAIN LINES
<br />6.5.1 CONDENSATE DRAIN LINE MATERIAL SHALL BE 1" O.D. HARD DRAWN COPPER TUBING.
<br />MECHANICAL CONTRACTOR SHALL INSTALL HEAT TRACE IN LOW TEMP SECTION OF VAULT. REF ELECTRICAL
<br />SPECIFICATIONS SECTION 3.5.12 FOR HEAT TRACE REQUIREMENTS.
<br />6.5.2 THE LINES SHALL BE CAPABLE OF BEING OPENED AS CLOSE TO THE EVAPORATOR DRAIN
<br />AS POSSIBLE TO ALLOW EFFECTIVE CLEANING.
<br />6.5.3 THE DRAIN LINE SHALL BE TRAPPED ON A VERTICAL SLOPE PRIOR TO REACHING THE
<br />RECEIVING FLOOR DRAIN OR PIT (WHICHEVER 1S ALLOWABLE UNDER LOCAL CODES).
<br />6.5.4 THE DRAIN LINE SHALL HAVE A DEFINITE SLOPE AWAY FROM THE EVAPORATOR OR DRAIN
<br />PIT (WHICHEVER IS ALLOWABLE UNDER LOCAL CODES). THE DRAINS FROM THE EVAPORATORS SHALL BE
<br />JOINED TO MAIN DRAIN LINE WHICH SHALL RUN TO A DRAIN LOCATION SHOWN ON THE MECHANICAL PLAN
<br />AND SHALL BE FIRMLY SUPPORTED WITH STRAPS AT LEAST EVERY SIX FEET ALONG THE DRAIN RUN.
<br />6.6 SYSTEM SET-UP
<br />6.6.1 THE OIL LEVEL IN THE COMPRESSOR SIGHT GLASS SHALL BE BETWEEN 1/3 AND 112 FULL AT
<br />ALL TIMES (FOR SEMI -HERMETIC COMPRESSORS ONLY. HERMETIC COMPRESSORS DO NOT HAVE OIL SIGHT
<br />GLASS).
<br />6.6.2 THE PROPER AMOUNT OF REFRIGERANT SHALL BE CHARGED INTO THE SYSTEM WITH THE
<br />COMPRESSOR OPERATING AT THE PROPER DEAD PRESSURE (SEE MANUFACTURER'S SPECIFICATIONS).
<br />6.6.3 ONLY SUNISO-3GS OIL SHALL BE USED ION THE MEDIUM TEMP SYSTEMS AND MOBIL EAL
<br />ARCTIC 22 CC OIL SHALL BE USED IN THE LOW TEMP SYSTEMS.
<br />6.6.4 THE THERMOSTATIC EXPANSION VALVE SUPERHEAT IS CONTROLLED BY THE BEACON
<br />MICRO -PROCESSOR BOARD AND IS FACTORY SET AT 8 DEG. THE MECHANICAL CONTRACTOR SHALL CHECK
<br />THE SUPERHEAT AT THE COMPRESSOR TO ENSURE THE COMPRESSOR SUPERHEAT MEETS THE
<br />COMPRESSOR MANUFACTURER'S GUIDELINES. THE MECHANICAL CONTRACTOR MAY HAVE TO ADJUST
<br />SUPERHEAT AT BEACON BOARD TO CORRECT INCORRECT SUPERHEAT READINGS AT THE COMPRESSOR,
<br />6.6.4.1 THE WALK-IN COOLER AND FREEZER THERMOSTATS AREA PART OF THE BEACON MICRO-
<br />PROCESSOR SYSTEM AND ARE FACTORY MOUNTED. THE MECHANICAL CONTRACTOR SHALL PROGRAM THE
<br />BEACON II BOARDS AS FOLLOWS:
<br />VAULT COOLER TEMPERATURE SETPOINTS:
<br />VAULT COOLER: +38° F
<br />VAULT ICE: +20' F
<br />VAULT FREEZER: -10° F
<br />OTHER REFRIGERATION EQUIPMENT TEMPERATURE SETPOINTS:
<br />SANDWICH CASE: +32° F
<br />CONDIMENT STATION: +38' F
<br />ICE CREAM CASE: -10' F
<br />ICED COFFEE/CREAM DISPENSER: +38' F
<br />UNDER COUNTER REFRIGERATED STORAGE: +38' F
<br />BACKROOM FREEZER: +10' F
<br />6.7 PENETRATIONS
<br />6.7.1 ALL OPENINGS THROUGH THE WALK-IN PANELS REQUIRED FOR HANGERS, CONDENSATE
<br />DRAIN LINES, STRAPPING AND REFRIGERANT PIPING SHALL BE SEALED EXTERIOR AND INTERIOR BY THE
<br />MECHANICAL CONTRACTOR TO PREVENT MOISTURE FROM ENTERING THE INSULATION, AND TO MAINTAIN
<br />THE WALK-IN VAPOR BARRIER.
<br />6.7.2 THE MECHANICAL CONTRACTOR SHALL SEAL OFF ALL PASS -THROUGH OPENINGS
<br />REQUIRED FOR REFRIGERANT TUBING IN ACCORDANCE WITH REQUIREMENTS STATED ON MECHANICAL
<br />PLAN.
<br />7. ELECTRICAL
<br />7.1 ALL PROVISIONS FOR WIRING (LINE VOLTAGE AND BEACON LOW VOLTAGE) SHALL BE BY THE
<br />ELECTRICAL_ CONTRACTOR. FINAL BEACON LOW VOLTAGE WIRING CONNECTIONS SHALL BE BY THE
<br />MECHANICAL CONTRACTOR.
<br />8. MECHANICAL CONTRACTOR CLEAN-UP RESPONSIBILITIES
<br />8.1 REMOVE ALL CRATING FROM PREMISES.
<br />8.2 REMOVE ALL LABELS AND CLEAN CONDENSING SURFACES IF REQUIRED, AND STRAIGHTEN
<br />CONDENSING COIL FINS IF REQUIRED.
<br />8.3 TOUCH-UP AND REPAIR PAINT AS REQUIRED.
<br />mommommiDT'illg-
<br />1.1 HEREAFTER IN THIS SPECIFICATION, THE WORD "MECHANICAL CONTRACTOR" SHALL REFER TO THE
<br />INSTALLING MECHANICAL OR REFRIGERATION CONTRACTOR AND "OWNER" SHALL REFER TO 7-ELEVEN. OWNER SHALL
<br />PURCHASE THE EQUIPMENT AND ARRANGE TO HAVE THAT EQUIPMENT DELIVERED TO THE STORE SITE. THE
<br />MECHANICAL CONTRACTOR SHALL HAVE UNITS UNCRATED, SET IN PLACE, LEGS INSTALLED (IF APPLICABLE),
<br />EQUIPMENT LEVELED, INSTALL THE CONDENSATE DRAIN LINES (IF REQUIRED) AND START UP THE UNITS PER THE
<br />INSTALLATION INSTRUCTIONS PROVIDED WITH THE EQUIPMENT. POWER WIRING FROM THE ELECTRICAL PANEL TO
<br />THE WALK-IN COOLER IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR'S ELECTRICAL SUB -CONTRACTOR.
<br />EXACT LOCATIONS OF EQUIPMENT WILL BE DETERMINED BY THE FLOOR PLAN AND MEASUREMENTS AT THE
<br />BUILDING AND IN COOPERATION WITH CONTRACTORS AND IN ALL CASES, SHALL BE SUBJECT TO APPROVAL OF THE
<br />OWNER'S DIVISION CONSTRUCTION MANAGER.
<br />2. CODE REQUIREMENTS
<br />2.1 ALL PROPOSALS SHALL INCLUDE, AND WORK PERFORMED SHALL BE ACCOMPLISHED IN ACCORDANCE WITH
<br />ALL APPLICABLE LOCAL LAWS, REGULATIONS, ORDINANCES, STATUTES AND CODES, WHICH SHALL BE DELINEATED
<br />AND ALL MODIFICATIONS REQUIRED BY THE INSPECTING AUTHORITY SHALL BE MADE BY THE MECHANICAL
<br />CONTRACTOR WITHOUT ADDITIONAL COST TO THE OWNER. ANY DEVIATIONS REQUIRED DUE TO UNFORESEEABLE
<br />CIRCUMSTANCES, SHALL BE CALLED TO THE ATTENTION OF THE DIVISION CONSTRUCTION MANAGER.
<br />3.1 MECHANICAL
<br />CONTRACTOR SHALL GUARANTEE ALL
<br />OPERATION
<br />WILL BE FREE FROM DEFECTS IN WORKMANSHIP ,.L CONTRACTOR PROVIDED
<br />FURNISHEDFOR INSTALLATION, FOR A PERIOD OF 90 DAYS AFTER ACCEPTANCE BY THE
<br />ANY PART OF THE
<br />DEFECTIVE, DAMAGED
<br />SHALL BE HANDLED AS STATED IN PARAGRAPH4 ENTITLED "MECHANICAL CONTRACTOR INSPECTION
<br />3.2 MECHANICAL CONTRACTOR SHALL PROVIDE THE FOLLOWING INFORMATION TO THE EQUIPMENT
<br />3.2.1 MODEL NUMBER OF THE UNIT
<br />3.2.2 SERIAL NUMBER OF THE UNIT
<br />3.2.3 DATE OF INSTALLATION
<br />3.2.4 DETAILED ACCOUNT OF THE PROBLEM, DIAGNOSIS, AND REPAIR WORK REQUIRED
<br />3.2.5 PARTS REQUIRING REPLACEMENT
<br />3.2.6 STORE NUMBER AND ADDRESS
<br />3.3 MECHANICAL CONTRACTOR SHALL FURNISH TO THE OWNER'S REPRESENTATIVE ALL CERTIFICATES
<br />OF FINAL INSPECTION AND APPROVAL FROM INSPECTION AUTHORITIES HAVING JURISDICTION.
<br />4. INSTALLATION REQUIREMENTS
<br />4.1 GENERAL
<br />4.1.1 THE EQUIPMENT FROM VARIOUS MANUFACTURERS IS CONFIGURED SIMILARLY WITH MINOR
<br />DIFFERENCES DUE TO INDIVIDUAL MANUFACTURER'S DESIGN. INSTALLATION INSTRUCTIONS ARE BASICALLY
<br />SIMILAR FOR EACH MANUFACTURER'S EQUIPMENT.
<br />4.2 RETAIL REFRIGERATION EQUIPMENT
<br />4.2.1 INSTALLATION INSTRUCTIONS
<br />PARTS REQUIRED:
<br />1. R448A REFRIGERANT FOR ALL REMOTE CONDENSING UNITS EXCEPT ICE MAKER
<br />AND SLURPEES (R404A): UP TO 15LBS 4 OZ PER CONDENSER.
<br />2. WALL MOUNTED ELECTRICAL JUNCTION BOX WITH STRAIN RELIEF
<br />3. 50 FEET (MAX) OF ELECTRICAL CONDUIT" WITH MINIMUM AWG 22 STRAND 7X30 WIRE.
<br />4. MOUNTING HARDWARE FOR JUNCTION BOX BRACKETS, CLAMPS AND REMOTE CONDENSER.
<br />CONTENTS OF KIT:
<br />1. REMOTE CONDENSER
<br />2. FLEXIBLE LINE SET
<br />3. QUICK DISCONNECT FITTINGS
<br />4. 50 FEET OF 3/8" INSULATED LINE SET
<br />5. 50 FEET OF 5/8" INSULATED LINE SET
<br />6. COPPER ELBOW FITTINGS
<br />7. MOUNTING STRUT AND CLAMPS
<br />8. JUMPER FOR ELECTRICAL CONNECTION
<br />INSTALLATION INSTRUCTIONS:
<br />1. UNPACK CONDENSER
<br />2. CONDENSER INSTALLATION
<br />3. REFRIGERATION LINE INSTALLATION
<br />4. ELECTRICAL CONNECTIONS
<br />5. FBD UNIT INSTALLATION
<br />6. REFRIGERANT CHARGING
<br />7. UNIT START UP
<br />INSTALLATION:
<br />1. CAREFULLY UNPACK THE CONDENSING UNIT.
<br />2. CONDENSER INSTALLATION: INSTALL THE REMOTE CONDENSER ACCORDING TO THE
<br />DOCUMENT "INSTALL AND MAINTENANCE DATA" PROVIDED WITH THE CONDENSER.
<br />4.2.2 ICE MAKER (PIPED TO THE HOSHIZAKI REMOTE CONDENSING UNIT. PRECHARGED
<br />REFRIGERANT LINE SET FURNISHED BY THE ICE MAKER MANUFACTURER.)
<br />4.2.3 SANDWICH CASE (PIPED TO THE HEATCRAFT REMOTE CONDENSING UNIT. PRECHARGED
<br />REFRIGERANT LINE SET FURNISHED BY THE SANDWICH CASE MANUFACTURER.)
<br />4.2.4 SLURPEE (PIPED TO THE FBD SINGLE REMOTE CONDENSING UNIT. PRECHARGED
<br />REFRIGERANT LINE SET FURNISHED BY THE SLURPEE MANUFACTURER.)
<br />4.2.5 FROZEN LEMONADE (PIPED TO FBD DUAL REMOTE CONDENSING UNIT. PRECHARGED
<br />REFRIGERANT LINE SET FURNISHED BY THE FROZEN LEMONADE MANUFACTURER.)
<br />4.3 CONDENSATE DRAIN
<br />4.3.1 NORMALLY, THE CONDENSATE DRAIN CONNECTION INCLUDED WITH THE UNIT, WILL BE STUBBED
<br />OUT AT THE BOTTOM OF THE CABINET, (IF REQUIRED). MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL
<br />A DRAIN LINE FROM THE CABINETS TO THE FLOOR DRAIN. IT SHALL BE PERMISSIBLE TO MANIFOLD THE DRAINS
<br />INTO A COMMON DRAIN LINE; THE MANIFOLD SHALL BE 1 INCH DIAMETER MINIMUM. COPPER WILL BE
<br />ACCEPTABLE. EACH DRAIN CONNECTION SHALL BE FULL SIZE OF THE EQUIPMENT DRAIN CONNECTION SERVED.
<br />4.4 UNIT START UP AND CHECKOUT
<br />4.4.1 MECHANICAL CONTRACTOR SHALL FOLLOW THE SPECIFIC UNIT INSTALLATION PROCEDURES
<br />WHICH ARE PACKAGED WITH EACH PIECE OF EQUIPMENT WHEN DELIVERED TO THE STORE.
<br />5. MECHANICAL CONTRACTOR RESPONSIBILITIES
<br />5.1 REMOVE ALL CRATING FROM PREMISES.
<br />5.2 CHECK EACH PIECE OF REFRIGERATION EQUIPMENT FOR DAMAGES. NOTIFY THE OWNER'S DIVISION
<br />OFFICE IMMEDIATELY. MAKE REPAIRS ONLY WHEN AUTHORIZED TO DO SO.
<br />5.3 OBTAIN, PAY FOR AND FURNISH ALL REFRIGERATION PERMITS REQUIRED BY LOCAL OR STATE
<br />ORDINANCES OR CODES.
<br />5.4 COMPLY WITH ALL LOCAL AND STATE CODES; IN JURISDICTION WHENEVER THE SPECIFICATIONS
<br />DO NOT MEET CODES, THE CODES SHALL TAKE PREFERENCE. NOTIFY OWNER'S DIVISION CONSTRUCTION
<br />OFFICE REGARDING REQUIRED MODIFICATIONS.
<br />5.5 NO EXTRAS SHALL BE ALLOWED DUE TO CONDITIONS WITH WHICH THE MECHANICAL CONTRACTOR
<br />SHOULD HAVE BEEN FAMILIAR.
<br />6. ELECTRICAL
<br />6.1 ALL PROVISIONS FOR WIRING, EXCEPT LOW VOLTAGE CONNECTIONS, SHALL BE BY THE ELECTRICAL
<br />CONTRACTOR, FINAL CONNECTIONS SHALL BE BY THE MECHANICAL CONTRACTOR FOR LOW VOLTAGE.
<br />6.2 ALL ELECTRICAL POWER SUPPLY WIRING SHALL BE BY ELECTRICAL CONTRACTOR,
<br />6.3 ALL LINE VOLTAGE CONTROL WIRING FROM THE RETAIL REFRIGERATION EQUIPMENT TO THE
<br />CONDENSER UNIT(S) SHALL BE BY THE ELECTRICAL CONTRACTOR.
<br />Corporate Office:
<br />3025 Highland Parkway, Suite 850
<br />Downers Grove, IL 60515
<br />Phone: 312.756.7778
<br />info@sevansolutions.com www.sevansolutions.com
<br />Regional Office:
<br />37704 Hills Tech Drive
<br />Farrington Dills, Ml 4 331
<br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY
<br />REVISIONS
<br />NO. DATE DESCRIPTION
<br />1 11/04/20 OWNER/PEER REVIEW COMMENTS
<br />II CONSULTANT II
<br />1
<br />EFnyineers,
<br />760 Creel Drive
<br />Wood IEfinpis 60191
<br />TA r30/595-8800
<br />F= tx (330/59 r-8818
<br />www.` 0VVet1 IrIeors,com
<br />SEAL
<br />M
<br />A
<br />Pg
<br />" $ 7-
<br />ISSU DATE: 11/04/20
<br />I CUSTOMER I I
<br />I PROJECT DESCRIPTION I
<br />I I PROJECT LOCATION
<br />607 SE I
<br />WAY
<br />I I SHEET TITLE I I
<br />REFRIGERATION
<br />SPECIFICATIONS
<br />SHEET MANAGEMENT
<br />T �
<br />PROJECT NO.: 41564
<br />DATE ISSUED: 08-07-20
<br />DRAWN BY: JS
<br />REVIEWED BY: JT
<br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF
<br />SEVAN MULTI -SITE SOLUTIONS, INC.
<br />REPRODUCTiON OR ALTERATION OF THIS DOCUMENT W H HOUT THE EXPRESSE
<br />WRITTEN PERMISSION OF SEVAN MULTI -SITE SOLUTIONS, INC. IS PROHIBITED.
<br />(NOT PUBLISHED: ALL RIGHTS RESERVED.)
<br />COPYRIGHT BY SEVAN MULTI -SITE SOLUTIONS, INC. 2013
<br />I SKEET NUMBER
<br />
|