A-7
<br />+42"
<br />GFCI
<br />24"
<br />FCI
<br />11
<br />A-4
<br />WP/GFCI
<br />F_6 �-
<br />a
<br />co
<br />L-8
<br />+24"
<br />HBL-4792
<br />L-4
<br />5
<br />L-14
<br />\ 6
<br />B-9
<br />+921 19
<br />154. L-16
<br />(TYP) 19
<br />CONDUIT PENETRATION
<br />CONDUIT AT CEILING PENETRATION
<br />SEALED WITH SILICONE
<br />FILLED WITH SEALANT
<br />SEALANT
<br />CONDUIT AND WIRING TO PANEL
<br />CONDUIT AND WIRING TO
<br />FURNISHED BY OWNER, INSTALLED BY G.C.
<br />NEXT JUNCTION BOX ON
<br />COOLER/FREEZER BOX CEILING
<br />SAME SYSTEM
<br />CEILING MOUNTED WP JUNCTION BOX
<br />WITH THREADED HUBS AND GASKETED
<br />COVERPLATE
<br />TYPICAL COIL
<br />PROVIDE CEILING MOUNTED MANUAL
<br />TWO -POLE SWITCH IN WEATHERPROOF
<br />ENCLOSURE.
<br />LIQUID TIGHT FLEX CONDUIT TO
<br />KNOCKOUT ON UNIT. FINAL
<br />CONNECTION TO COIL BY GC
<br />NOTE: DO NOT LOCATE WP JUNCTION BOX DIRECTLY IN FRONT OF DISCHARGE FAN, OFFSET TO SIDE.
<br />2
<br />EVAPORATOR
<br />COIL WIRING
<br />N.T.S.
<br />SF: 1.00 CC
<br />JN:H:A20029.34
<br />FN:E1.0_P0WER & SPECIAL SYSTEMS PLAN
<br />1 ELECTRICAL FLOOR PLAN
<br />E1.0 SC: 1 /4" _ 1'-On
<br />ELECTRICAL NOTES:
<br />1. ALL ISOLATED GROUND RECEPTACLES SERVED FROM PANEL "B" SHALL BE
<br />OF THE ISOLATED GROUND TYPE, ALL CIRCUITS SHALL CONTAIN A HOT,
<br />NEUTRAL, GROUND AND ISOLATED GROUND CONDUCTOR.
<br />2. AMPACITY OF ALL CONDUCTOR SIZES SHOWN ON PLANS IS BASED ON 75°C
<br />RATED TERMINATIONS AND CONDUCTOR INSULATION. CONTRACTOR SHALL
<br />FIELD VERIFY EQUIPMENT TEMPERATURE RATINGS OF ALL TERMINATIONS
<br />AND ADJUST CONDUCTOR SIZES PER NEC 110.14(C)
<br />3. ALL WIRING IS COPPER. REFER TO ELECTRICAL SPECIFICATIONS FOR
<br />FURTHER INFORMATION.
<br />4. ALL WALL MOUNTED RECEPTACLES SHALL BE 18" A.F.F ON CENTER.
<br />UNLESS NOTED OTHERWISE.
<br />5. FURNISH AND INSTALL CORD AND CAP FOR ALL EQUIPMENT CONNECTED
<br />TO NEMA L-14R RECEPTACLE.
<br />6. G.C. TO COORDINATE POWER REQUIREMENTS FOR EXTERIOR SIGNAGE.
<br />7. THE UNGROUNDED AND GROUNDED CONDUCTORS OF EACH MULTIWIRE
<br />BRANCH CIRCUIT SHALL BE GROUPED BY WIRE TIES OR SIMILAR MEANS IN
<br />AT LEAST ONE LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF
<br />ORIGINATION. REF 2017 NEC (210.4(D))
<br />8. EACH MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS
<br />THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED
<br />CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUITS ORIGINATES.
<br />REF 2017 NEC (210.4)
<br />9. CONDUITS THAT ARE EXPOSED TO WIDELY DIFFERENT TEMPERATURES,
<br />SUCH AS COOLERS, FREEZERS OR SERVICE ENTRANCE CONDUCTORS,
<br />SHALL BE SEALED TO PREVENT CIRCULATION OF AIR AND/OR MOISTURE.
<br />REF 2017 NEC (300.7 (A))
<br />10. CONDUIT AND WIRING IN AREAS WHERE EXPOSED SHALL BE ROUTED AT 90
<br />DEGREE ANGLES PERPENDICULAR OR PARALLEL TO JOISTS. COORDINATE
<br />PAINTING OF CONDUIT WITH ARCHITECTURAL FINISHES.
<br />Milo
<br />0
<br />NEW PANEL F
<br />3-2 F F=21
<br />42" 7S-26 co F�27
<br />i � N
<br />y
<br />r NEW PANEL L
<br />SM-
<br />-�^ NEW PANELS S-23
<br />NEW PANEL B
<br />A-(22,24) NEW PANEL A
<br />+421, 4
<br />A-46
<br />B-5 _ +84"
<br />SM 25)_ GFCI
<br />0 2DF
<br />L6-30R +24"
<br />A-53 F"
<br />+42" FLL �4-j43,45) Io +72"
<br />L5-20 J•.BR GFCI B-10
<br />+84" IM 8-26
<br />PM I I *42" A-47 2t3F
<br />B-3 +72" +24°
<br />+42" TST B-6 GFCI
<br />+42" NT �- B-8
<br />+42"ML A 13 2DF
<br />L6-30R - t +24
<br />B-(43;45)
<br />MK
<br />r A-2
<br />,',
<br />w er FC A-(27,29)'
<br />L6-30R 10
<br />+ 2
<br />SH L14-5OR I I
<br />+42" 'A=(23 25) L .�
<br />SH @H1 RECtRC PUMP
<br />+42"-L14-50R P-1(
<br />13-(36; 8) +36" 1 PH. 41W..
<br />I Q Ili
<br />ILLI
<br />CP
<br />A-8. 1 1 I
<br />II I
<br />a �.1 ,
<br />+42" 0 i €I
<br />- WATER HEATER
<br />3 P/60A/N F
<br />±96" ' A-44
<br />i f
<br />A-38
<br />CIA 0 t
<br />P=9
<br />_M
<br />' +93"
<br />`GFCI
<br />2
<br />B-50
<br />\\-420 A-9
<br />26
<br />19
<br />O ELECTRICAL EQUIPMENT CONNECTION SCHEDULE
<br />SYMBOL
<br />DESCRIPTION
<br />VOLTAGE
<br />LOAD
<br />FEEDER
<br />FED FROM
<br />WIRE
<br />CONDUIT
<br />BREAKER
<br />BW
<br />BUN WARMER
<br />208/1 PH
<br />1.1 FLA
<br />2#12+G
<br />1/2"
<br />20A/2P
<br />A-(33,35)
<br />CH
<br />CHILI/CHEESE DISPENSER
<br />120/1 PH
<br />4.5 FLA
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />B-40
<br />CP
<br />CAPPACCINO
<br />120/1 PH
<br />15.OA
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-8
<br />CS
<br />CONDIMENT STATION
<br />120/1 PH
<br />3.3A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-36
<br />CW
<br />COLD WELL
<br />120/1PH
<br />4.5A
<br />2#12+G
<br />2#10+G
<br />1/2"
<br />3/4"
<br />20A/1P
<br />30A/2P
<br />B-28
<br />A-(48,50)
<br />DO
<br />DOYON OVEN
<br />208/1 PH
<br />21.OA
<br />FC
<br />FRANKE COFFEE
<br />208/1PH
<br />27.8A
<br />2#10+G
<br />3/4"
<br />30A/2P
<br />A-(27,29)
<br />FL
<br />FROZEN LEMONADE
<br />208/1PH
<br />5.1A
<br />2#12+G
<br />1/2"
<br />20A/2P
<br />A-(43,45)
<br />HC
<br />HEATED CABINET
<br />120/1 PH
<br />10.83A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />8-20
<br />HD
<br />HAND DRYER
<br />120/1 PH
<br />1500 VA
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />B-13
<br />HFD
<br />HOT FOOD DISPLAY
<br />120/1PH
<br />9.2A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-51
<br />MK
<br />MILK COOLER
<br />120/1PH
<br />86W
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-11
<br />ML
<br />MELITTA
<br />208/1PH
<br />273A
<br />2#10+G
<br />3/4"
<br />30A/2P
<br />B-(43,45)
<br />MW
<br />(2) MICROWAVE
<br />208/1PH
<br />14.3A
<br />2#12+G
<br />1/2"
<br />20A/2P
<br />A-(40,42),(18,20)
<br />NC
<br />NOVELTY CASE
<br />20811PH
<br />15.OA
<br />2#12+G
<br />1/2"
<br />20A/2P
<br />A-(26,28)
<br />NT
<br />NITRON
<br />120/1PH
<br />4.5A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-13
<br />ODM
<br />OPEN DISPLAY MERCHANDISER
<br />120/1PH
<br />6.92A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-15
<br />OV
<br />OVEN
<br />208/1PH
<br />5990W
<br />2#10+G
<br />3/4"
<br />30A/2P
<br />B-(27,29)
<br />PC
<br />PASTRY CASE
<br />120/1 PH
<br />4.8A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-3
<br />PF
<br />PREP FREEZER
<br />120/1 PH
<br />5.3A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />B-7
<br />I
<br />ICE MACHINE
<br />120/1PH
<br />13.7A
<br />2#12+G
<br />3/4"
<br />20A/1P
<br />B-26
<br />PM
<br />POST MIX
<br />120/1 PH
<br />TOA
<br />2#12+G
<br />1/2"
<br />20AIlP i
<br />B-6
<br />PR
<br />(2) PREP REFRIGERATOR
<br />120/1 PH
<br />3.3A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />B-11, A-49
<br />RG
<br />(2) ROLLER GRILL
<br />208/1 PH
<br />103A
<br />2#12+G
<br />1/2"
<br />20A/2P
<br />A-(19,21), (10,12)
<br />SHD
<br />SANDEN HOT DISPLAY
<br />120/1 PH
<br />4.5A
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-14
<br />SH
<br />(2) SOFT HEAT COFFEE
<br />120/208/1PH
<br />25A
<br />3#8+G
<br />3/4"
<br />40A/2P
<br />A-(23,25), B-(36,38)
<br />SM
<br />(2) SLURPEE MACHINE
<br />208/1PH
<br />2O.2A
<br />2#10+G
<br />3/4"
<br />30A/2P
<br />A-(22,24), B-(23,25)
<br />TST
<br />TOUCHSCREEN T TEA TOWER
<br />120/1 PH
<br />2.OA
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A.5
<br />2LT
<br />2-DOOR LOW TEMP
<br />208/1PH
<br />12.OA
<br />2#12+G
<br />1/2"
<br />20A/2P
<br />B-(56,58)
<br />2DF
<br />(2) 2-DOOR FREEZER
<br />120/1PH
<br />10.OA
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-2 B-8
<br />CIA
<br />U OPEN AIR CASE
<br />120/1 PH
<br />3.0 FLA
<br />2#12+G
<br />1/2"
<br />20A/1P
<br />A-38
<br />11M 1-DOOR ICE MERCHANDISER 120/1PH 8.OA 2#12+G 1/2" 20A/1P B-1
<br />/
<br />ELECTRICAL SCHEDULE NOTES:
<br />ES1. REFER TO ARCHITECTURAL DRAWINGS & EQUIPMENT DRAWINGS FOR EXACT NUMBER AND LOCATIONS OF EQUIPMENT.
<br />ES2. ALL SINGLE PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 AMPERES OR LESS AND THREE PHASE
<br />RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100
<br />AMPERES OR LESS INSTALLED IN THE KITCHEN AND
<br />FOOD/BEVERAGE AREA SHALL HAVE GROUND FAULT CIRCUIT
<br />INTERRUPTER PROTECTION.
<br />ES3. CONTRACTOR SHALL COORDINATE EXACT WIRING REQUIREMENTS
<br />(IE. PHASE REQUIREMENTS) FOR ISOLATED GROUND
<br />EQUIPMENT, POS EQUIPMENT AND AUTOMATIC BEVERAGE SYSTEM WITH EQUIPMENT VENDOR PRIOR TO INSTALLATION,
<br />ES4. CONTRACTOR SHALL VERIFY ALL EQUIPMENT ELECTRICAL REQUIREMENTS WITH '7-ELEVEN' OPERATION MANAGER, PRIOR TO
<br />INSTALLATION.
<br />ES5. VERIFY EXACT ELECTRICAL REQUIREMENTS OF NEW EQUIPMENT PRIOR TO ANY INSTALLATION. NOTIFY PROJECT MANAGER OF
<br />ANY DISCREPANCIES.
<br />/
<br />KEYNOTES - POWER
<br />L-10
<br />12
<br />11
<br />EXHAUST FAN. SWITCH FAN WITH RESTROOM LIGHTS, TYP.
<br />/
<br />+42"
<br />WP, GFCI
<br />2
<br />DEVICES SHALL BE NEMA 5-20 UNLESS NOTED OTHERWISE. TYP OF
<br />120V-20A CIRCUITS.
<br />B-(30,32,34)
<br />EXTERIOR SIGNAGE J-BOX. COORDINATE FINAL LOCATION WITH
<br />3/4"C.-3 # 6
<br />a
<br />SIGNAGE CONTRACTOR AND CONSTRUCTION MANAGER. RUN
<br />/
<br />& 1 # 10 GROUND
<br />EXTERIOR BUILDING SIGNS THROUGH PHOTOCELL DRIVEN
<br />CONTACTOR. PROVIDE PAD -LOCKABLE BREAKER FOR MAINTENANCE.
<br />aENERGY
<br />MANAGEMENT ENCLOSURE PROVIDED BY OTHERS, PROVIDE
<br />120V DEDICATED CIRCUIT ONLY.
<br />RECEPTACLE FOR ATM SIGN. VERIFY LOCATION WITH CONSTRUCTION
<br />MANAGER PRIOR TO COMMENCEMENT OF WORK.
<br />ElWINDOW
<br />RECEPTACLES. MOUNT FLUSH IN CEILING, MOUNT
<br />ABOVE WINDOW HEADER IN OPEN CEILING AREA, PER NEC
<br />ElTELEPHONE
<br />BOARD: 4'X4'X3/4" PLYWOOD WITH (1) #6 CU.
<br />GROUND FOR FUTURE USE MOUNTED ABOVE 4'X4'X3/4"
<br />PLYWOOD WITH (1) #6 CU. GROUND PER TELE. CO.
<br />REQUIREMENTS. MOUNT RECEPTACLE ADJACENT TO OR
<br />ABOVE TELEPHONE BOARD, DO NOT MOUNT BELOW.
<br />El
<br />PROVIDE PAD -LOCKABLE BREAKER FOR MAINTENANCE PER N.E.C.
<br />422.31(B). COORDINATE EXACT LOCATION OF ELECTRICAL OUTLET WITH
<br />CONSTRUCTION MANAGER PRIOR TO ROUGH -IN.
<br />El
<br />REFER TO EVAPORATOR COIL WIRING DETAIL, RE: 3/E1.0, TYP,
<br />EVEEDER
<br />1_
<br />ROOT: COORDINATE INSTALLATION WITH FUELING PLANS,
<br />INSTALL IN ACCESSIBLE LOCATION. MOUNT AT 48" A.F.F. TO BOTTOM,
<br />ERECEPTACLE
<br />FOR MOTION SENSOR FAUCET. REFER TO
<br />ARCHITECTURAL SHEETS FOR EXACT ROUGH -IN LOCATIONS, TYP.
<br />12
<br />RECEPTACLE FOR WATER FILTRATION BOOSTER PUMP, E.C, TO INSTALL
<br />WATER-RESISTANT, "WHILE -IN -USE" COVER.
<br />13
<br />E.C. TO PROVIDE WIRING FOR COOLER AND/OR FREEZER DOOR
<br />HEATERS AND DOOR FRAMES AND CONNECT TO MANUFACTURER
<br />SUPPLIED JUNCTION BOX ES.
<br />1
<br />14
<br />PR VID POWER TO AUTOMATIC FLUSH, COORDINATE EXACT
<br />REQUIREMENTS WITH THE MANUFACTURER, REFER TO
<br />ARCHITECTURAL SHEETS FOR EXACT ROUGH -IN LOCATIONS.
<br />ESERVICE
<br />RECEPTACLE, WEATHERPROOF GFCI.
<br />ENOT
<br />USED.
<br />EflEMERGENCY
<br />GAS SHUT-OFF @ 48" A.F.F.
<br />19
<br />TRANSMITTER RECEPTACLE, G.C. TO PROVIDE. MR. CHIME ENTRANCE
<br />-7
<br />TELEPHONE/
<br />DATA OUTLET
<br />JO
<br />JUNCTION BOX
<br />((�
<br />125 V RECEPTACLE,
<br />DUPLEX
<br />125 V RECEPTACLE,
<br />CEILING MOUNT DUPLEX
<br />125 V RECEPTACLE,
<br />SIMPLEX
<br />125 V RECEPTACLE,
<br />DOUBLE DUPLEX
<br />(NOTE: NOT ALL SYMBOLS ARE USED)
<br />ALERT TRANSMITTER (DA4TAC). CONTACT MR, CHIME AT 877-672-4463
<br />20 RECEIVER RECEPTACLE, G.C. TO PROVIDE. MR. CHIME RECEIVER (DARD).
<br />HINSTALL WEATHERPROOF SPEAKER, G.C. TO PROVIDE MR. CHIME
<br />SPEAKER (SPK).MOUNT ON WALL IN WALK IN COOLER AND CONNECT TO
<br />NEAREST RECEIVER OUTSIDE OF COOLER.
<br />22 ISOLATED GROUND (IG) 20 AMP CIRCUIT FOR ATM, FLUSH MOUNT
<br />DUPLEX FACE PLATE WITH ORANGE RECEPTACLE.
<br />23 NOT USED.
<br />HNOT USED.
<br />25 E.C. TO MAINTAIN 2" SPACING BETWEEN RECEPTACLES FOR STAND UP
<br />LOTTO MACHINE.
<br />26 RECEPTACLE FOR SPEAKER TO BE FLUSH MOUNTED DIRECTLY BEHIND
<br />SPEAKER. VERIFY EXACT HEIGHT AND LOCATION WITH ARCHITECTURAL
<br />DRAWINGS. INSTALLER TO HIDE POWER CABLE BEHIND THE SPEAKER
<br />USING CABLE TIES.
<br />27 NOT USED.
<br />sevan
<br />DESIGN SOLUTIONS, P.C.
<br />Corporate Office:
<br />3025 Highland Parkway, Suite 850
<br />Downers Grove, IL 60515
<br />Phone: 312.756.7778
<br />info@sevansolutions.com www.sevansolutions.com
<br />Regional Office:
<br />37704 Hills Tech Drive
<br />Farmington Hills, MI 48331
<br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY
<br />A REVISIONS
<br />NO. DATE DESCRIPTION
<br />1 11/04/20 OWNER/PEER REVIEW COMMENTS
<br />DICKERSON', ENGINEERING, INC.11
<br />Professional Electrical Engineers
<br />3343 NORTH RIDGE AVENUE
<br />ARLINGTON HEIGHTS, IL 60004
<br />TEL (847) 966-0290
<br />WWW,DEI-PE COM
<br />SEAL
<br />ti DICk
<br />Q " O
<br />(� z Z
<br />36369
<br />�GISTIE,
<br />t. EX RES 0 >/O5/202
<br />SIGNATURE
<br />11/04/2020
<br />DATE
<br />11•T-1411 IN 1191 ;,,
<br />l �I
<br />PROJECT LOCATION
<br />•
<br />07 SE EVERETT MALL
<br />WAY
<br />EVERETT, WA 0•
<br />SHEET TITLE
<br />ELECTRICAL
<br />POWER PLAN
<br />SHEET MANAGEMENT
<br />PROJECT NO.: 41564
<br />DATE ISSUED: 08-10-20
<br />DRAWN BY: SR
<br />REVIEWED BY: DD
<br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF
<br />SEVAN MULTI -SITE SOLUTIONS, INC.
<br />REPRODUCTION OR ALTERATION OFTHIS DOCUMENT WITHOUTTHE EXPRESSED
<br />WRITTEN PERMISSION OF SEVAN MULTI -SITE SOLUTIONS, INC. IS PROHIBITED.
<br />(NOT PUBLISHED: ALL RIGHTS RESERVED.)
<br />COPYRIGHT BY SEVAN MULTI -SITE SOLUTIONS, INC. 2093
<br />W
<br />
|