My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11108 EVERGREEN WAY ALEM MARKET 2022-11-17
>
Address Records
>
EVERGREEN WAY
>
11108
>
ALEM MARKET
>
11108 EVERGREEN WAY ALEM MARKET 2022-11-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2022 8:39:02 AM
Creation date
11/17/2022 8:38:24 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11108
Tenant Name
ALEM MARKET
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4110 • <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Monday, December 13, 2021 12:36 PM <br /> To: payanbrothers@gmail.com <br /> Subject: City of Everett Permit Services: 11108 Evergreen Way (M2111-080) - First Building Intake <br /> Review <br /> Hello, Aurelio. <br /> Your application has been received and a permit set up. However, the submitted documents are not <br /> sufficiently developed for us to perform a comprehensive review at this time. <br /> Revised construction-level documents should be submitted for review. Two complete sets of the revised <br /> drawings should be submitted to replace the previously submitted drawing sets. Preliminary comments are <br /> provided below to assist in revising the drawings, but these are not intended to provide a comprehensive <br /> review. The resubmittal documents should include an itemized response letter clarifying how the review <br /> comments below have been addressed. <br /> Intake Review Comments: <br /> 1. The submitted drawings consist of excerpted architectural sheets from Building Permit No. B2107-001 and <br /> the manufacturer's generic shop drawings for the hood system. Project specific mechanical drawings <br /> showing the proposed location of the hood system and other information as required (e.g., roof framing, <br /> installation details, etc.) should be submitted for review. See IBC Section 107.2.1. <br /> 2. The anticipated location of the hood system appears to be against an interior wall of unknown <br /> construction. The hood should be provided with a minimum 18-inch clearance to combustible <br /> materials. The note in the "Section Plan Detail" on Sheet 2-of-2 regarding the required clearance is not <br /> adequate. Alternative, reduced clearances, including the sides and top,should be substantiated with <br /> details per IMC Section 308.4.2. See IMC Section 507.2.6. <br /> 3. The proposed hood weighs more than 20 lb and is suspended from the framing above. Details for the <br /> connection of the hood to the structure are required; the details provided in the manufacturer's drawings <br /> are not adequate. The hood shall be provided with lateral bracing per ASCE 7-10 Section <br /> 13.6. Alternatively, the hood may be braced by a direct connection to the adjacent wall provided that the <br /> minimum 18-inch clearance is maintained. See IBC Sections 107.2.1, 1604.1 and 1613.1. <br /> 4. The duct is provided with fire wrap at the interior of the building. The wrap terminates at the exterior <br /> wall. The wrap should continue a minimum of 18 inches outside the exterior wall if the wall construction <br /> includes combustible materials (e.g., siding, exterior wall sheathing, etc.). The 18-inch clearance shall be <br /> measured perpendicular to the wall surface. Clearances may be reduced per IMC Table 308.4.2. See IMC <br /> Section 506.3.6. <br /> 5. Up-blast fans serving Type I hoods shall be installed with a hinge, restraint, and flexible electrical cable to <br /> permit inspection and cleaning. These do not appear to be specified. The drawing should be revised. See <br /> IMC 506.5.3. <br /> 1 � . <br />
The URL can be used to link to this page
Your browser does not support the video tag.