4110 • <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Monday, December 13, 2021 12:36 PM <br /> To: payanbrothers@gmail.com <br /> Subject: City of Everett Permit Services: 11108 Evergreen Way (M2111-080) - First Building Intake <br /> Review <br /> Hello, Aurelio. <br /> Your application has been received and a permit set up. However, the submitted documents are not <br /> sufficiently developed for us to perform a comprehensive review at this time. <br /> Revised construction-level documents should be submitted for review. Two complete sets of the revised <br /> drawings should be submitted to replace the previously submitted drawing sets. Preliminary comments are <br /> provided below to assist in revising the drawings, but these are not intended to provide a comprehensive <br /> review. The resubmittal documents should include an itemized response letter clarifying how the review <br /> comments below have been addressed. <br /> Intake Review Comments: <br /> 1. The submitted drawings consist of excerpted architectural sheets from Building Permit No. B2107-001 and <br /> the manufacturer's generic shop drawings for the hood system. Project specific mechanical drawings <br /> showing the proposed location of the hood system and other information as required (e.g., roof framing, <br /> installation details, etc.) should be submitted for review. See IBC Section 107.2.1. <br /> 2. The anticipated location of the hood system appears to be against an interior wall of unknown <br /> construction. The hood should be provided with a minimum 18-inch clearance to combustible <br /> materials. The note in the "Section Plan Detail" on Sheet 2-of-2 regarding the required clearance is not <br /> adequate. Alternative, reduced clearances, including the sides and top,should be substantiated with <br /> details per IMC Section 308.4.2. See IMC Section 507.2.6. <br /> 3. The proposed hood weighs more than 20 lb and is suspended from the framing above. Details for the <br /> connection of the hood to the structure are required; the details provided in the manufacturer's drawings <br /> are not adequate. The hood shall be provided with lateral bracing per ASCE 7-10 Section <br /> 13.6. Alternatively, the hood may be braced by a direct connection to the adjacent wall provided that the <br /> minimum 18-inch clearance is maintained. See IBC Sections 107.2.1, 1604.1 and 1613.1. <br /> 4. The duct is provided with fire wrap at the interior of the building. The wrap terminates at the exterior <br /> wall. The wrap should continue a minimum of 18 inches outside the exterior wall if the wall construction <br /> includes combustible materials (e.g., siding, exterior wall sheathing, etc.). The 18-inch clearance shall be <br /> measured perpendicular to the wall surface. Clearances may be reduced per IMC Table 308.4.2. See IMC <br /> Section 506.3.6. <br /> 5. Up-blast fans serving Type I hoods shall be installed with a hinge, restraint, and flexible electrical cable to <br /> permit inspection and cleaning. These do not appear to be specified. The drawing should be revised. See <br /> IMC 506.5.3. <br /> 1 � . <br />