1716 CEDAR ST 2020 Plans 2022-12-14
>
Address Records
>
CEDAR ST
>
1716
>
Plans
>
1716 CEDAR ST 2020 Plans 2022-12-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2022 10:35:57 AM
Creation date
12/14/2022 10:29:56 AM
Metadata
Fields
Template:
Address Document
Street Name
CEDAR ST
Street Number
1716
Permit
BW2006-002
Year
2020
Notes
REPAIR TO EXTG SFR; REPAIR BEDROOM PORTION OF HOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DASHED LINE DENOTES <br />EXISTING ROOF ABOVE <br />1 A 1� - <br />IN <br />z <br />n <br />W <br />V) <br />w <br />w <br />I <br />w <br />J <br />J <br />a <br />I <br />C <br />D <br />0 <br />I <br />0 <br />I <br />0 <br />_I <br />ELECT. <br />MTR <br />L <br />E KITCHEN <br />2 <br />42'-0" <br />3 <br />13'-7" 24'-5" Ile <br />0 <br />I EM EM <br />VERIFY / ADD SW-1 / E SHEATHING AND �) BEDROOM <br />NAILING REQUIREMENTS <br />THIS WALL <br />E iLIVING< <br />\ DEMO <br />- - - 0 e �® <br />1 <br />/ REMOVE EXISTING <br />PLUMBING, RELOCATE <br />XI T G EXIST'G AS REQUIRED PER <br />PLAN A200B <br />3 0 x 6 8 3 0 x 6 8 <br />k <br />UNHEATED 771 7-5 <br />SPACE: (E) DECK _ <br />SEE '0,-4& 1 ZIZ6 <br />�q 2sx6s <br />GC TO VERIFY / ADD (E) <br />HDRS MIN (2) 2X6 TYP <br />1 <br />THESE LINES. <br />VERIFY / ADD SW-1 <br />SHEATHING AND <br />f NAILING REQUIREMENTS <br />r/ �H1S-WALL_ <br />�(IST'G �✓�-. � <br />4 <br />1 <br />PROPERTY LINE <br />EXISTING ROOF TO <br />REMAIN - LIFT / <br />SHORE & RESET ON <br />NEW EXTERIOR WALLS <br />REMOVE EXISTING <br />EXTERIOR WALLS, SIDING <br />AND ROTTEN WOOD <br />FOUNDATION <br />MECHANICAL, ELECTRICAL AND <br />PLUMBING PERMITS BY GCI <br />GC TO VERIFY / AD <br />(E) HDRS MIN 4X12 <br />E RAGS <br />Q�T10 : <br />REMOVE EXISITNG WINDOW <br />REPLACE WITH NEW SAFTY <br />GLAZING WINDOWS U = .28 MAX <br />ADD R21 BATT INSULATION TO <br />WALL AND R g INSULATION TO <br />ROOF z/7 <br />PROVIDE ANCHOR BOLT, <br />SHEATHING, NAILING AND STRAP <br />REQUIREMENTS PER IRC FIGURE <br />R602.10.6.4 <br />EXIST'G <br />70x 6 8 <br />0 2 4 8 12 <br />lvl= 4' <br />z <br />0 <br />GENERAL NOTES; <br />1. ALL WORK SHALL MEET ALL APPLICABLE BUILDING CODES, COUNTY <br />CODES & ORDINANCES <br />2. ALL NAILING SHALL COMPLY WITH NAILING SCHEDULES IN I.R.C. AS <br />LISTED IN STRUCTURAL NOTES <br />3. COMPLIANCE CARDS TO BE POSTED FOR WALLS FLOORS CEILINGS <br />FOR VERIFICATION OF INSULATION <br />4. PROVIDE METAL NAIL STOPPERS ADJ. TO PLUMBING / ELECTRICAL <br />5. ALL CONCRETE TO WOOD CONTACT - WOOD TO BE PRESSURE <br />TREATED <br />6. MECHANICAL, PLUMBING & ELECT. TO CONFIRM & OBTAIN ALL <br />NECESSARY PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION <br />(AHJ) INCLUDING CITY OF EVERETT <br />7. HVAC TO BE FORCED AIR GAS WITH INTERMITTENT WHOLE HOUSE <br />VENTILATION USING EXHAUST FANS (EXISTING SYSTEM SFR & NEW <br />SYSTEM DADU) <br />8. HOT WATER BY OTHER. INSTAHOT UNDER CABINET MOUNTED SYSTEM <br />OR HOT WATER TANK <br />9. MECHANICAL VENTILATION / OUTSIDE AIR SUPPLY <br />REFERENCE IRC M1507 <br />10. FIRE AND DRAFT STOPS: PER IRC R302.11 AND 302.12. <br />INSTALL DRAFT STOPS SO THAT CONCEALED SPACE DOES NOT EXCEED <br />1,000SF <br />LEGEND <br />O <br />SMOKE ALARM PER IRC:R314 <br />HARDWIRED TO THE MAIN ELECTRICAL SYSTEM WITH <br />BATTERY BACKUP 0 <br />1 <br />EF <br />EXHAUST FANS PER IRC:M1507 <br />50CFM INTERMITTENT BATHROOM <br />100CFM INTERMITTENT KITCHEN (WHF) <br />© <br />PROVIDE STAIRWELL ILLUMINATION <br />PER IRC R303.6 <br />SG <br />SAFETY GLAZING PER IRC R308 <br />CO <br />CARBON MONOXIDE ALARMS PER <br />IRC R315 <br />WINDOW SYMBOL - <br />SEE SCHEDULE SHEET A6.03 <br />® <br />EGRESS WINDOW SYMBOL - <br />PER IRC:R310 AS LOCATED ON PLANS <br />EGRESS <br />SEE SCHEDULE SHEET A6.03 <br />[] <br />DOOR SYMBOL - <br />SEE SCHEDULE SHEET A6.01 <br />O <br />WALL & FLOOR TYPES - <br />SEE SHEET A9.01 <br />+9'-0"GWB <br />CEILING HEIGHT <br />LOCAT. <br />SEE SHEET A7.00 FOR FINISH SCHEDULE, <br />MAT-# <br />EQUIPMENT SCHEDULE & LIGHTING SCHEDULE <br />SW1 <br />SHEARWALL TAG <br />SPAN <br />DIRECTION <br />STAIRS PER <br />IRC R311.7 <br />APPROVAL STAMP AREA <br />CITY OF EVE- RETT <br />REVIEWED FOR PERMIT <br />z <br />U) <br />U <br />m <br />N <br />0 <br />� <br />c <br />co <br />0 <br />fu <br />:3 Z <br />a) CL <br />> <br />20 <br />ca U <br />w <br />� �®� <br />ca <br />E � <br />® m N <br />tN t) 14, <br />►l ' <br />1 <br />co <br />cu <br />cu <br />CD <br />A2.01A <br />
The URL can be used to link to this page
Your browser does not support the video tag.