My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1716 CEDAR ST 2020 Plans 2022-12-14
>
Address Records
>
CEDAR ST
>
1716
>
Plans
>
1716 CEDAR ST 2020 Plans 2022-12-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2022 10:35:57 AM
Creation date
12/14/2022 10:29:56 AM
Metadata
Fields
Template:
Address Document
Street Name
CEDAR ST
Street Number
1716
Permit
BW2006-002
Year
2020
Notes
REPAIR TO EXTG SFR; REPAIR BEDROOM PORTION OF HOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />1. ALL WORK SHALL MEET ALL APPLICABLE BUILDING CODES, COUNTY <br />CODES & ORDINANCE <br />2. ALL NAILING SHALL COMPLY WITH NAILING SCHEDULES IN I.R.C. AS <br />LISTED IN STRUCTURAL NOTES <br />3. COMPLIANCE CARDS TO BE POSTED FOR WALLS FLOORS CEILINGS <br />FOR VERIFICATION OF INSULATION <br />4. PROVIDE METAL NAIL STOPPERS ADJ. TO PLUMBING / ELECTRICAL <br />NORTH WALL TO BE 1 5. ALL CONCRETE TO WOOD CONTACT - WOOD TO BE PRESSURE <br />A ONE HOUR RATED TREATED <br />WALL PER WALL Al1 2 TYPE 3 SHEET A901 3 4 6. MECHANICAL, PLUMBING & ELECT. TO CONFIRM & OBTAIN ALL <br />42'-0" PROVIDE ROOF EAVE FIRE NECESSARY PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION <br />BLOCKING PER FOOTNOTE 1 (AHJ) INCLUDING CITY OF EVERETT <br />13'-7" 24'-5" TABLE 302.1(1) <br />REPLACEMENT AREA 7. HVAC TO BE FORCED AIR GAS WITH INTERMITTENT WHOLE HOUSE <br />SW-1 1'X6"W X 10" DP CONC. VENTILATION USING EXHAUST FANS (EXISTING SYSTEM SFR & NEW <br />NEW CONCRETE W1 _ - - _ FOOTING w/_(2) #5 CONT. SYSTEM DADU) <br />IdBATI ON -&- - - - - - FLOOR FRAMING - - o o W2 BOTT - TYP <br />DASHED LINE DENOTES o 1 3 x 2 8" CONC. STEMWALL w 4 8. HOT WATER BY OTHER. INSTAHOT UNDER CABINET MOUNTED SYSTEM <br />I SILL @ 44" 0 a / # PROVIDE R49 BATT OR HOT WATER TANK <br />EXISTING ROOF ABOVE 1 S9.01 2 x 2 @ 12 O.C. EW CENT. TYP INSULATION IN ATTIC SPACE <br />3 3 ILL @ 54" PROVIDE VENTING 1SF/150SF <br />ATTIC SPACE 9. MECHANICAL VENTILATION / OUTSIDE AIR SUPPLY <br />I VET- - - - - - - - - - - - - - - - -VENT- REFERENCE IRC M 1507 <br />q - - 50% EAVE VENTS / 50% <br />` ` EXISTING ROOF TO REMAIN - RIDGE VENT <br />- - - - - -�jj/- <br />-- - - _ - - - - - - - 10. FIRE AND DRAFT STOPS: PER IRC R302.1 1 AND 302.12. <br />/ - I LIFT / SHORE & RESET ON INSTALL DRAFT STOPS SO THAT CONCEALED SPACE DOES NOT EXCEED <br />(E) BEDROOM OIL T I NEW EXTERIOR WALLS 1,000SF <br />/ ALL HEADERS TO PROVIDE R49 BATT <br />BE (2) 2X10'S ( I INSULATION <br />202 2 PROVIDE FIRE BLOCKING AT NORTH WALL <br />PROVIDE 24"X24" <br />p i EAVE PER R302.1 (1 ) <br />o +8'-5" ATTIC ACCESS 2 ° 6 $ o '. I S9.01 <br />o E LIVIN� E N OPENINGS LIMITED TO 25% PER <br />\ @ I I NEW 2X4 EXTERIOR TABLE 6302.1(1) <br />PROVIDE o O 2 WALLS @ 16" O.C. w WALL AREA 205SF <br />NEW CO CO x 3 OW I CLOSED CELL SPRAY OPENINGS AREA = 10.8SF <br />ALARM J I FOAM INSULATION R21 HEAD WALL FLOOR FRAMING/ FOUNDATION NOTES: <br />AND 0 N EGRESS RAIN - 1 10.8SF / 205SF = 5% 1. SEE SHEET S/101 FOR GENERAL STRUCTURAL NOTES. <br />�01- --- ------------- - LESS THAN 25% = OK <br />INTERCONNECTED o t \ ,_ ( 2. FOR TYPICAL DETAILS NOT REFERENCED ON PLAN SEE SHEET <br />B - - SMOKE T - - 36 PJT- - - - - - - - -,/ElT - S901 & S902 <br />ALARMS ( - - - - � '�i - � CRAWL SPACE NOTES <br />0 VENT CRAWL SPACE @ 1 SF VENT / 150SF AREA <br />5'-0' 3 x 2 3. VERIFY ALL PLAN DIMENSIONS PRIOR TO CONSTRUCTION. <br />1 DATUM SILL @ 44"MAX VENTS TO BE 8 X14 EACH 112SQ IN EACH <br />10 SW-1 1 CRAWL SPACE AREA = 220SF 4. D2 INDICATES SPAN DIRECTION OF 23 32" NAILED AND GLUED <br />S9.01 REQUIRED = 1.47SF REQUIRED / <br />4 VENTS @ 220SO IN EACH 1.5 SF PER VENT W/ 8d @ 6" OC PANEL EDGES; 8d @ 12" OC FIELD. <br />CRAWL SPACE 4 VENTS PROVIDED @ 1.5SF EACH = 6SF PROVIDED <br />ACCESS - 18" CLEARANCE MIN FROM GROUND TO FLOOR 5. ALL EXTERIOR WALL FRAMING TO BE 2x6 @�'NTER. <br />SEE FRAMING FRAMINGDTL. 4/A901 - PROVIDE 6MIL POLY VB AT CRAWL SPACE GROUND 6. ALL EXTERIOR WALLS TO BE SHEARWALL TY - <br />ER <br />z SHEARWALL SCHEDULE, TYP UNO. <br />- PROVIDE CRAWL SPACE ACCESS 18"X24" MIN <br />CO 7. VERIFY ALL PLAN DIMENSIONS WITH ARCHITECTURAL PRIOR TO <br />ui +8'-5" O CONSTRUCTION. <br />cn JE,8. CONTRACTOR TO COORDINATE DRAWINGS WITH ALL OTHER <br />LLJw ENCLOSED E DECK DISCIPLINES PRIOR TO POURING FOUNDATIONS INCLUDING BUT <br />PORCH NOT LIMITED TO: DOOR AND WINDOW LOCATIONS, DEPRESSED <br />I o SLAB SLOPES, LOCATION OF DRAINS, BLOCK -OUTS FOR <br />o I (E)KITCHEN PLUMBING, MECHANICAL AND ELECTRICAL CONDUITS, ETC. <br />W I10 <br />`� N SHOWER NOTES 9. POST SIZES AND LOCATIONS ARE SPECIFIED AT BASE OF <br />UPC 408.9 ARRANGE CONTROLS SO THAT POST. <br />THE BATHER CAN ADJUST THE VALVES <br />EF PRIOR TO STEPPING INTO THE SHOWER <br />MECHANICAL, ELECTRICAL AND SPRAY <br />ELECT. 1 PLUMBING PERMITS BY GCI SHOWER WALLS PER IRC 307.2 <br />NONABSORBENT SURFACE TO 72" <br />MTR A. F. F. <br />MOUNT SHOWER HEAD <br />@ 6'-8"AFF LEGEND <br />(VERIFY WITH OWNER) <br />< F�B> SMOKE ALARM PER IRC;R314 <br />(E)RES11,00 24' MIN SAFETY GLASS DOOR O HARDWIRED TO THE MAIN ELECTRICAL SYSTEM WITH <br />OUTSWING OR SLIDER ONLY BATTERY .BACKUP <br />SHOWER PAN PER DTL EF EXHAUST FANS PER IRC:M1507 <br />C - - - - 11 /A901 0 50CFM INTERMITTENT BATHROOM <br />100CFM INTERMITTENT KITCHEN (WHF) <br />0 PROVIDE STAIRWELL ILLUMINATION <br />L PER IRC R303.6 <br />SG SAFETY GLAZING PER IRC R308 <br />E AG CARBON MONOXIDE ALARMS PER <br />CO <br />IRC R315 <br />WIN® SEE DOSCHEDULLEO SHEET A6.03 <br />EGR® PERES C:R3100ASSSYMBOL <br />LOCATED ON PLANS <br />EGRESS SEE SCHEDULE SHEET A6.03 <br />® DOOR SYMBOL - <br />SEE SCHEDULE SHEET A6.01 <br />O WALL & FLOOR TYPES - <br />SEE SHEET A9.01 <br />+9'-0"GWB CEILING HEIGHT <br />LOCAT. SEE SHEET A7.00 FOR FINISH SCHEDULE, <br />MAT-# EQUIPMENT SCHEDULE & LIGHTING SCHEDULE <br />F_sw__ll SHEARWALL TAG <br />SPAN <br />DIRECTION <br />STAIRS PER IRC R311.7 <br />1 - PROPOSED FLOOR PLAN <br />SCALE:1/4" = V-0" <br />Z <br />0 <br />0 2 4 8 12 <br />1 ll = 41 <br />APPROVAL STAMP AREA <br />z <br />O <br />w <br />U) <br />U <br />co <br />07 <br />w <br />a <br />N <br />N <br />0 <br />0 <br />Lo <br />0 <br />0 <br />0 <br />fu <br />N z <br />Z <br />-4-4 <br />N d <br />4-1 <br />Up <br />ca U E <br />h <br />LU <br />U <br />co <br />U � �i <br />d <br />_M <br />d cnd'cu <br />N E - <br />1 cu O L <br />E N <br />O E L6 p <br />N C/) I- Y <br />r <br />L0 <br />U <br />r- <br />� <br />N <br />cv <br />o <br />mo <br />r <br />cn <br />00 <br />W <br />♦♦�^^, <br />VJ <br />0) <br />cu <br />c <br />E_ <br />�--+ <br />o <br />Mco <br />W <br />r <br />w <br />A2.01 B I <br />