Laserfiche WebLink
8'-2" A.F.F. <br />T.O. 8" 18 GA. <br />SURFACE <br />MOUNTED STEEL <br />STRAPPING <br />2'-4" A.F.F. <br />T.O. 8" 18 GA. <br />SURFACE <br />MOUNTED STEEL <br />STRAPPING <br />REFER TO <br />REFLECTED <br />CEILING PLAN <br />SHEET A102 <br />FOR CEILING <br />TYPE AND <br />HEIGHT. <br />01722-00 <br />LJ 01402-00 <br />B-PVC30-A101-REV01 <br />CONSTRUCTION FLOOR PLAN <br />SCALE: 1/4" = T-0" <br />CENTER LINE <br />LEASE LINE <br />NEW WALLS <br />NEW WALL W/ SOUND BATTS <br />EXISTING WALLS <br />— _ _ _ _ NEW/EXTG.BULKHEAD <br />DETAIL WALL TYPES <br /># SHEET # <br />DOOR NUMBER <br />DOORS SHOWN FULLY OPEN TO <br />90' ARE CONSIDERED AS NEW <br />;F DOORS, HARDWARE, JAMBS, ETC. <br />B <br />,1 <br />DOORS SHOWN PARTIALLY <br />OPEN TO 45' ARE <br />CONSIDERED AS EXISTING <br />DOORS, HARDWARE, <br />JAMBS, ETC. <br />A-PVC30-A101-REV00 <br />LARGE SMALL O.D. <br />EXAM EXAM RECEPTION ADJACENT TENANT <br />LtHStuiNt <br />1. <br />LEASE LINE; G.C. TO VERIFY ACTUAL MEASUREMENTS AND REPORT ANY DISCREPANCIES IMMEDIATELY, <br />2. <br />EXISTING STOREFRONT GLAZING SYSTEM / CHANNELS/ DOORS, HARDWARE TO REMAIN. <br />3. <br />APPLY WHITE SILICONE CAULK ALONG JOINTS AT ALL WET AREAS. <br />4. <br />EDGE OF CEILING SOFFIT ABOVE, SEE REFLECTED CEILING PLAN. <br />5. <br />EXISTING FLOOR DRAIN, REFER TO P200 PLUMBING DRAWINGS. <br />& <br />EXISTING DEMISING PARTITION. G.C. TO PATCH/REPAIR AS REQUIRED TO MAINTAIN REQUIRED FIRE RATING <br />& LEVEL 4 FINISH, TYP. <br />7. <br />INSTALL NEW MOP SINK WITH HOT WATER HEATER ABOVE IN THE BOH AS INDICATED. REFER TO PLUMBING <br />DRAWINGS. <br />8. <br />VENT HOLES ARE NEEDED FOR THE MONITORS THAT WILL BE MOUNTED ON THIS WALL. SEE ELEVATION <br />14/A401b AND SECTION 15/A401b. <br />9. <br />ELECTRICAL DISTRIBUTION EQUIPMENT, REFER TO ELECTRICAL DRAWINGS. GC TO DEMARCATE IN CAUTION <br />TAPE THE REQUIRED CLEARANCE AT THE ELECTRICAL EQUIPMENT, AS INDICATED. MUST BE 42" CLEAR FROM <br />FACE & 30" CLEAR SIDE TO SIDE, ABOVE AND BELOW. <br />10. <br />NEW PHONE BOARD. (2) 4'x8' PLY INSTALLED 8' SIDE VERTICAL @ 18" AFF. REFER TO ELECTRICAL DRAWINGS. <br />11. <br />G.C. TO PROVIDE AND INSTALL NEW METAL STUD FURRING ON DEMISING WALLS AND IN -WALL BLOCKING <br />FOR PERIMETER WALL FIXTURES. SEE SECTION "B" THIS SHEET & ELEVATION SHEETS FOR LOCATION. <br />12. <br />REFER TO SHEET A203 FOR GRAB BAR INSTALLATION DETAILS, TYPICAL, <br />13. <br />PROVIDE BLOCKING ABOVE CEILING FOR FULL HEIGHT FIXTURES TO ATTACH. COORDINATE WITH NEXTORE <br />PROJECT MANAGER. <br />14. <br />HI/LO WATER FOUNTAIN, SEE SHEET A203 AND PLUMBING DRAWINGS. <br />15. <br />EXISTING PARTITION TO REMAIN. G.C. TO OPEN WALL UP TO INSTALL SOUND BATT INSULATION, PATCH <br />AND REPAIR TO BRING TO LEVEL 4 FINISH. <br />16. <br />17. <br />18. <br />FLOOR TO CEILING MIRROR, SEE 4&5/A401a FOR PLAN VIEW (WALL TYPE IS MODIFIED AT MIRROR LOCATION) <br />AND SEE 10/A401a FOR SECTION FOR MORE INFORMATION. <br />19. <br />NEW HAND SINK. REFER TO PLUMBING DRAWINGS. <br />20. <br />PROVIDE IN -WALL BLOCKING AT ALL CABINET LOCATIONS, REFER TO'C' ON THIS SHEET. <br />21. <br />G.C. TO PROVIDE AND INSTALL SIN WALL BLOCKING FOR PERIMETER WALL FIXTURES. SEE DETAIL 'A' ON THIS <br />SHEET & ELEVATION SHEETS FOR LOCATIONS. <br />22. <br />IN AREAS WHERE THE FLOOR TO CEILING PERIMETER WALLS ARE, GYP. BD. ONLY NEEDS BROUGHT TO A <br />LEVEL 1 FINISH <br />2-PVC30-A101-REV01 <br />A. GC TO MAINTAIN ALL DIMENSIONS AS SPECIFIED FOR LENS PROCESS ROOM. NOTIFY NEXTORE PROJECT MANAGER OF <br />ANY DISCREPANCIES OF HOLD DIMENSIONS. <br />B. GC IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS REQUIRED AT THE <br />ENTRANCE TO PRODUCE A FLUSH CONDITION BETWEEN THE STORE CLOSURE LINE AND THE EXISTING MALL FLOORING. <br />C. GC SHALL SUPPLY AND INSTALL BLOCKING IN ALL WALLS AS REQUIRED TO SUPPORT WALL SHELVING AND CABINETS. <br />ANCHOR BLOCKING W/ SCREWS AT TOP MIDDLE AND BOTTOM (NO SILICONE). REFER TO MILLWORK SHOP DRAWINGS <br />FOR MOUNTING HEIGHTS. ALL BLOCKING NOTES FOUND ON SHOP DRAWINGS, SHALL BE PROVIDED AND INSTALLED BY <br />G.C. <br />D. ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION SERVICE AND <br />REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT, COORDINATE PLACEMENT WITH LANDLORD'S ON -SITE <br />REPRESENTATIVE. <br />E. REFER TO SPECIFICATIONS 0003-0006 <br />F. NO MATERIAL SUBSTITUTIONS WILL BE PERMITTED UNLESS SUBMITTED TO NEXTORE PROJECT MANAGER FOR REVIEW <br />AND APPROVAL. SUBSTITUTIONS CALLED OUT IN SPECIFICATIONS AS BEING NEEDED TO BE NOTED AT TIME OF BID. <br />G. ALL MANUFACTURERS RECOMMENDED INSTALLATION AND MAINTENANCE PROCEDURES ARE TO BE FOLLOWED BY <br />GENERAL CONTRACTOR ON THIS PROJECT, <br />H. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE REPRESENTATIVE LISTED AS SOON AS CONTRACTS ARE <br />AWARDED TO COMMUNICATE DESIRED SCHEDULE DATES AND PROJECT INFORMATION. <br />L GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL UPCHARGES ASSOCIATED WITH THE DELAY OF ORDERING <br />SPECIFIED PRODUCTS. <br />J. ANY QUESTIONS CONCERNING THESE SPECIFICATIONS SHALL BE DIRECTED TO THE ARCHITECT FOR DOCUMENT <br />CLARIFICATION. <br />K. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED & SUPERVISED BY GC. <br />L. G.C. TO POST A SIGN ABOVE ENTRY DOORS WITH ONE INCH LETTERS STATING "THIS DOOR TO REMAIN UNLOCKED <br />WHEN BUILDING IS OCCUPIED". WHEN UNLOCKED, DOORS MUST SWING WITHOUT OPERATION OF ANY LATCHING <br />DEVICE. (NOTE: DEADBOLTS ARE NOT ALLOWED ON SECOND EXIT DOOR.) <br />M. FIRE MARSHAL TO DETERMINE FINAL QUANTITIES AND LOCATION OF FIRE EXTINGUISHERS. <br />N. ALL DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS NOTED OTHERWISE ON PLANS. <br />0. ALL NEW AND EXISTING GYP. WALL BOARD TO BE FINISH LEVEL 4. CEILING GYP. TO BE LEVEL 5 FINISH. <br />P. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE IN COMPLIANCE <br />WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES <br />OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. <br />1-PVC30-A101-REV00 <br />ONT <br />O <br />z <br />NB�(lDRE <br />®ESIGN 8v- <br />CONSTRUCTION <br />MANAGEMENT <br />STORE 46261 <br />910 CENTER <br />910 SE EVERETT MALL WAY <br />EVERETT, WA 98208 <br />Construction for: <br />0 0 O <br />o <br />O <br />® � O <br />G O O <br />00 J <br />N 0 <br />JL <br />Z3 0 <br />�o <br />Qo <br />UJ�i <br />Revisions: <br />Mark Date <br />Architect of Record <br />cc_ N <br />C D R T L A N D <br />M 0 R G A N <br />ARCHITECT <br />711 N. FIELDER RD. <br />ARLINGTON, TX 76012 <br />PH: (817) 635-5696 <br />FAX: (817) 635-5699 <br />Seal <br />REGISTERED <br />A IT;ECT <br />CORTLAND MORGAN <br />STATE OF WASHINGTON <br />Architect Job No.: <br />33N2022 <br />Nextore Store Design Revision No.: <br />Nextore Project <br />Number 86841 <br />Brand Design Type: <br />PV 3.0 <br />ISSUED FOR: <br />® CONSTRUCTION <br />Title <br />CONSTRUCTION <br />FLOOR PLAN <br />0411912022 <br />Drawn By <br />STAFF <br />Checked By <br />j Sheet <br />i <br />A101 <br />