My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
910 SE EVERETT MALL WAY 2022 PEARLE VISION Plans 2023-01-09
>
Address Records
>
SE EVERETT MALL WAY
>
910
>
PEARLE VISION
>
Plans
>
910 SE EVERETT MALL WAY 2022 PEARLE VISION Plans 2023-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 8:00:38 AM
Creation date
12/15/2022 1:19:58 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
910
Tenant Name
PEARLE VISION
Permit
B2204-058
Year
2022
Notes
REMODEL OF FORMER T MOBILE INTO A PEARLE VISION CENTER
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOL <br />TYPE DESCRIPTION <br />SYMBOL <br />TYPE <br />TC.;Ri 9,YrT <br />e1 <br />TRACK LIGHT HEAD. COLOR TO <br />® <br />SUPPLY DIFFUSER <br />e2 <br />MATCH TRACK. <br />00 <br />m2-L <br />RECESSED ADJUSTABLE 2-LIGHT <br />DOWNLIGHT, RECTANGULAR, PAINTED <br />SUPPLY SLOT TRIMMED DIFFUSER <br />SDs# LENGTH' <br />m3 L <br />TRIM TO MATCH CEILING. <br />RETURN SLOT TRIMMED DIFFUSER <br />sDR#LENGTH <br />CUSTOMER FACING SPRINKLER HEAD; <br />a <br />C1 <br />SECURITY CAMERA <br />CONCEALED HEAD, CUSTOM COLOR <br />CAP TO MATCH CEILING FINISH <br />TB <br />THREE CIRCUIT TRACK. <br />TB -TRACK COLOR BLACK <br />NON -CUSTOMER FACING SPRINKLER <br />TB (LENGTH) <br />- <br />HEAD; SEMI -RECESSED <br />(LENGTH) _ LENGTH OF TRACK <br />® <br />X1C <br />EXIT SIGN EDGE LIT LED (SEE <br />� <br />CEILING ACCESS PANEL. FINISH TO <br />MATCH CEILING FINISH <br />GENERAL NOTE'C' FOR MOUNTING) <br />SEE PLAN FOR SIZE <br />SPK <br />CEILING FLUSH MOUNT SPEAKER <br />RETURN DIFFUSER <br />EX <br />EXISTING LIGHT - RELAMP <br />O <br />TC <br />TRAFFIC COUNTER (SHOPPER TRAK) <br />A2L <br />2X2 LIGHT <br />® <br />A2L <br />2 X 2 LAY IN LED LIGHTING <br />az <br />A2LEM <br />A-PVC30-A102-REV01 <br />ELECTRICAL <br />ROOM <br />C ETR 107 — <br />CLG. HT.=OPEN <br />PRETEST <br />06 <br />C AC-5 CLG. HT.=9'-10 <br />BOH <br />077�105 -- <br />CLG. HT.=9'-10" <br />RESTROOM <br />C ETR 104 <br />DCLG. HT.=8'-0-1/2" <br />C P-TBD <br />REFLECTED CEI LING PLAN <br />SCALE: 1/4" = T-0" <br />1. <br />NEW STOREFRONT SIGN BY SIGN CONTRACTOR. <br />9. <br />AUDIO SPEAKER SYSTEM INSTALLED BY TENANT VENDOR, <br />2. <br />INSTALL GYP. BD. CEILING (GYP-1) AS INDICATED. SEE <br />CEILING FRAMING & FINISHING FOR SPEAKERS BY G.C., <br />SHEET A403 FOR CEILING DETAILS. <br />G.C. TO COORDINATE WITH VENDOR. <br />3 <br />GYP. BE) GEIHNG EeVE <br />10. <br />INSTALL TRAFFIC COUNTER (SHOPPER TRAK). REFER TO <br />ELECTRICAL DRAWINGS FOR MORE INFORMATINO. PAINT <br />TO MATCH SURROUNDING CEILING AREA. <br />4. <br />PROVIDE AND INSTALL 18"x18" ACCESS PANEL "STEALTH" <br />11. <br />EXISTING CEILING TO REMAIN. EXISITNG LIGHT & <br />NO EXPOSED FLANGE TYPE. PAINT TO MATCH ADJACENT <br />EXHAUST FAN TO REMAIN, RELAMP EXISTING LIGHT. <br />CEILING AREA. <br />COORDINATE WITH MECHANICAL & ELECTRICAL <br />DRAWINGS FOR DETAILS. <br />5. <br />LINE OF GYP. BD. BULKHEAD @ 7'-4j" A.F.F. SEE TYP. <br />12. <br />INSTALL WIRELESS ACCESS POINT, REFER TO ELECTRICAL <br />SOFFIT DETAIL 3/A401b. <br />DRAWINGS FOR MORE INFORMATION. <br />6. <br />LINE OF GYP. BD. BULKHEAD @ Y-10 1" A.F.F. SEE TYP. <br />13. <br />INSTALL NEW ACOUSTICAL CEILINGS AS INDICATED PER <br />SOFFIT DETAIL 3/A401b. <br />THE FINISH SCHEDULE. SEE SHEET A403 FOR CEILING <br />7. <br />START A FULL CEILING TILE AS SHOWN. <br />DETAILS. <br />& <br />SECURITY CAMERA SYSTEM INSTALLED BY TENANT <br />14. <br />NEW SUPPLY/ RETURN DIFFUSER IN GYP. BOARD CEILING. <br />VENDOR. SUGGESTED LOCATIONS INDICATED ON PLAN. <br />COORDINATE WITH MECHANICAL DRAWNGS. <br />COORDINATE WITH SECURITY VENDOR BEFORE <br />15. <br />EXISTING ACT CEILING AND LIGHTING TO REMAIN. G.C. TO <br />INSTALLATION. PAINT COLLAR TO MATCH SURROUNDING <br />REPLACE ANY DAMAGED CEILING TILES. RE -LAMP <br />CEILING AREA. (TYP.) SECURITY CAMERAS SHALL NOT <br />EXISTING LIGHT FIXTURE. <br />RECEIVE ANY ABOVE CEILING JUNCTION BOX. THE <br />16. <br />EXISTING LIGHTING AND OPEN CEILING IN ELECTRICAL <br />CAMERAS HAVE THEIR OWN RECESS MOUNT KITS. <br />ROOM TO REMAIN. RELAMP LIGHT FIXTURES. <br />LOCATION OF CAMERAS SHALL BE MARKED CLEARLY IN <br />ORDER FOR SECURITY CAMERA TECHNICIAN TO LOCATE. <br />17. <br />TRACK LIGHTING IN WINDOW TO BE INSTALLED FOR <br />ALL WIRING TO BE PROVIDED AND INSTALLED PER <br />FUTURE USE. <br />ELECTRICAL PLANS. <br />2-PVC30-A102-REV01 <br />FOR EXISTING FIRE SPRINKLER SYSTEM: <br />CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE <br />NEW SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED <br />BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN/SHOP <br />DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND <br />BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND <br />INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD <br />101, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. <br />DESIGN STANDARDS: <br />- HARD CEILING AND CEILING TILE AT RETAIL AREA / STOREFRONT: WHITE <br />CONCEALED HEADS; RELIABLE MODEL 'G-4'; TYCO 'RF-11' <br />- CEILING TILE AT OD, AND LENS PROCESS: RECESSED WHITE PENDANT HEADS <br />WITH WHITE TRIM RINGS; RELIABLE MODEL 'G-FT; TYCO 'TY-L' <br />- CEILING TILE AT LOUNGE, OFFICE, AND BACK OF HOUSE: WHITE PENDANT HEADS <br />WITH WHITE TRIM RINGS; RELIABLE MODEL "G"; 'TY-L' <br />3-PVC30-A102-REV00 <br />A. IT SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE <br />LIGHTING PACKAGE. THE G.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE <br />ELECTRICAL PACKAGE DISTRIBUTOR, <br />B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER <br />OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE <br />CEILING MOUNTED AND CENTERED ABOVE DOOR OR OPENING. IF PLAN LOCATIONS <br />ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR <br />DIRECTION. <br />C. G.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINARIES AND ASSOCIATED <br />LAMPS FURNISHED BY NEXTORE. G.C. IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY <br />OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES <br />PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE <br />CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT <br />SPECIFICATION OF LIGHTING FIXTURES. <br />D. CEILING GRID SHALL BE CENTERED IN ROOM UNLESS OTHERWISE NOTED, <br />E. INSTALL ALL NEW LIGHTS AND TRACK AS INDICATED. <br />F. INSTALL SUPPLY AND RETURN AIR DIFFUSERS AS INDICATED. COORDINATE WITH <br />MECHANICAL DRAWINGS FOR SPECIFIC TYPES AND INSTALLATION DETAILS. <br />DIFFUSERS TO BE PAINTED TO MATCH SURROUNDING CEILING AREA. (TYP. IN GYP. <br />CEILING) <br />G. INSTALL NEW SPRINKLER HEADS THROUGHOUT THE SPACE. COORDINATE WITH FIRE <br />PROTECTION PLAN. GC TO ORDER FIRE SPRINKLER CAPS WITH CUSTOM COLOR TO <br />MATCH CEILING COLORS. CODE REQUIRES ORDERING, NOT SELF PAINTING. (TYP.) <br />H. G.C. TO PROVIDE AND INSTALL FIRE DAMPERS IN DUCTWORK AT ANY DEMISING <br />WALL PENETRATIONS. TYP. <br />I. SEE SHEET A101 FOR AREAS WHERE BLOCKING ABOVE THE CEILING IS REQUIRED FOR <br />FREE STANDING FIXTURES. <br />1-PVC30-A102-REV00 <br />NDk,'7'ml ' �E <br />(DK <br />DESIGN <br />CONSTRUCTION <br />ION <br />MANAGEMENT <br />STORE 06261 <br />910 CENTER <br />910 SE EVERETT MALL WAY <br />EVERETT, WA 98208 <br />Construction for. . <br />z o <br />9-� <br />�o <br />oLn <br />o <br />® �O <br />c <br />o <br />t9 Do J (6 <br />w <br />co)U <br />O d <br />LU > <br />J � � <br />N x <br />� J <br />/) O <br />CD <br />Q CD <br />LJJ I <br />00 <br />Revisions: <br />Mark Date <br />Architect of Record <br />C mv <br />C0RTLANG <br />M 0 R G A N <br />ARCHITECT <br />711 N. FIELDER RD. <br />ARLINGTON, TX 76012 <br />PH: (817) 635-5696 <br />FAX: (817) 635-5699 <br />Seal <br />REGISTERED <br />A ITECT <br />CORTLAND MORGAN <br />STATE OF 1YASHINGTON i <br />Architect Job No.: <br />33N2022 <br />Nextore Store Design Revision No.: <br />7 <br />Nextore Project <br />Number 86841 <br />Brand Desian TVDe: <br />PV 3.0 <br />WOODn ... <br />ISSUED FOR: <br />X1 CONSTRUCTION <br />Title <br />REFLECTED <br />CEILING PLAN <br />Date <br />04/19/2022 <br />Drawn By <br />STAFF <br />Checked By <br />CM <br />Sheet <br />I A102 <br />
The URL can be used to link to this page
Your browser does not support the video tag.