GENERAL DEMOLITION NOTES - - <br />1. IN EVERY INSTANCE OF DEMOLITION AND/OR REMODELING, THE E.C. SHALL 10. ALL WALLS, CEILINGS, FLOORS, ETC., BEING DISTURBED BY THE WORK SHALL <br />FIGURE A COMPLETE JOB AS NONE OTHER SHALL BE ACCEPTED. BE RETURNED TO FINISHED CONDITIONS TO MATCH EXISTING BY THE E.C. & <br />HE SHALL DO HIS OWN CUTTING &. PATCHING AS NECESSARY UNDER HIS <br />2. THE DRAWINGS ARE TO BE USED ONLY AS A GUIDELINE FOR DEMOLITION. CONTRACT. <br />THE E.C. MUST VISIT THE SITE PRIOR TO BIDDING TO VERIFY ALL WORK <br />REQUIRED FOR A COMPLETE JOB & INCLUDE THE COST OF SUCH WORK IN HIS 11. EXISTING MATERIALS SHALL BE TURNED OVER TO THE OWNER. IF NOT <br />BID. REQUIRED BY OWNER, THE E.C. SHALL REMOVE THESE MATERIALS FROM THE <br />PREMISES. <br />3. THE E.C. SHALL MAINTAIN EXISTING SERVICES TO & IN THE EXISTING AREA AS <br />REQUIRED. <br />4. IF NECESSARY, THE E.C. SHALL PROVIDE TEMPORARY SERVICES IN THE <br />EXISTING AREAS. <br />5. THE E.C. SHALL DISCONNECT & REMOVE ELECTRIC SERVICE TO ALL <br />MECHANICAL EQUIPMENT BEING REMOVED AS A RESULT OF THE <br />REMODELING. <br />6. ELECTRICAL EQUIPMENT & DEVICES SHALL BE REMOVED COMPLETE <br />INCLUDING CONDUIT & WIRE. <br />7. FLUSH MOUNTED WALL OUTLETS SHALL BE REMOVED AND THE WALL <br />PATCHED AND FINISHED TO MATCH THE ADJACENT WALL FINISHES. <br />AND/OR8. ANY EXISTING CONDUIT, WIRING ELECTRICAL MECHANICAL <br />DEVICES BEING DISTURBED BY THE WORK SHALL . REWORKED BY <br />CONTRACTORAS • ITS FORMER EXISTING <br />OPERATING CONDITION. <br />9. ANY CIRCUITS FEEDING THROUGH DEVICES OR EQUIPMENT BEING <br />RELOCATED, REWORKED, OR ABANDONED & SERVING OTHER ELECTRICAL <br />DEVICES, AND/OR EQUIPMENT SHALL BE MAINTAINED BY PROVIDING J-BOXES <br />OR OTHER ACCEPTABLE METHOD AS REQUIRED. <br />12. NO CONDUIT, BOXES, WIRING, OR CABLES SHALL BE INSTALLED WITHIN 1 1/2" <br />OF THE LOWEST POINT OF THE UNDERSIDE OF THE ROOF DECKING, NOR <br />SHALL THEY BE INSTALLED CONCEALED WITHIN METAL -CORRUGATED ROOF <br />DECKING, THE E.C. SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK <br />EXISTING CONDUIT, BOXES, WIRING, AND CABLING THAT IS NOT IN <br />COMPLIANCE WITH THIS REQUIREMENT. <br />13. ALL CONDUIT AND CABLING SHALL BE PROPERLY SUPPORTED AS REQUIRED <br />BY THE NATIONAL ELECTRICAL CODE. THE E.C. SHALL BE RESPONSIBLE TO <br />REPLACE AND/OR REWORK EXISTING CONDUIT AND/OR CABLING THAT IS <br />NOT IN COMPLIANCE WITH THIS REQUIREMENT. <br />i4. E.C. SHALL FIELD VERIFY SLAB ON GRADE FLOOR CONSTRUCTION TYPE PRIOR <br />TO CUTTING. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR CUT A <br />STRUCTURAL FLOOR SLAB THICKER THAN FOUR (4") INCHES WITHOUT PRIOR <br />WRITTEN APPROVAL FROM ENGINEER OF RECORD. NOTIFY ENGINEER OF <br />RECORD OF ANY SLAB THICKNESS GREATER THAN FOUR (4") INCHES PRIOR <br />TO PROCEEDING WITH ANY SAW CUTTING. REFER TO SHEET S001 FOR MORE <br />INFORMATION. <br />KEY NOTES - ELECTRICAL DEMOLITION <br />1. EXISTING PANELBOARD AND ASSOCIATED ELECTRICAL DEVICES TO REMAIN. <br />2. DISCONNECT AND REMOVE ALL EXISTING LIGHT FIXTURES - INCLUDING EXIT AND EMERGENCY FIXTURES. <br />3. DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES - INCLUDING SWITCHES, RECEPTACLES, DATA ETC. <br />4. DISCONNECT AND REMOVE EXISTING PHONE BOARD. SALVAGE ANY EXISTING EQUIPMENT TO BE RELOCATED TO NEW PHONE BOARD LOCATION. <br />ELECTRICAL - DEMOLITION <br />SCALE: 1/4" = 1'-D" <br />INFORMATION IS BASED ON SURVEY <br />PICTURES. VERIFY ALL WORK IN FIELD. <br />ADVISE NEX I ORE PROJECT MANAGER OF <br />ANY DISCREPANCIES. <br />Construction for: <br />Revisions: <br />Mark Date <br />ELECTRICAL <br />