Laserfiche WebLink
LARGE <br />EXAM <br />SMALL <br />EXAM <br />O.D. <br />RECEPTION <br />ELECTRICAL - LIGHTING <br />SCALE: 1/4" = 1'-0" <br />LIGHT FIXTURE SCHEDULE e NEXTORE 2 <br />ALL NEW FIXTURES ARE OWNER SUPPLIED, EC INSTALLED <br />TAG <br />DESCRIPTION <br />SUPPLIER <br />MANUFACTURER <br />MODELNUMBER <br />FINISH/COLORVOLIAGE <br />LAMP TYPE <br />LAMP CITY <br />FIXTURE WATTS <br />NOTES <br />A2L <br />20W RECESSED 2X2 LED PANEL <br />CREE <br />C-TR-FP22-25L-35K-WH <br />2X2 LED PANEL <br />120V <br />20W LED <br />20W LED CHIP, 0-10V DIMMING <br />1 <br />20 <br />20W RECESSED 2X2 LED PANELW/1320 LUM <br />A2L-EM <br />BATTERY <br />CREE <br />C-TR-FP22-25L-35K-WH-EB <br />2X2 LED PANEL <br />120V <br />2OW LED <br />20W LED CHIP, 0-10V DIMMING <br />1 <br />20 <br />E1 <br />BLACK TRACK HEAD, 15 DEGREE OPTICS <br />VIABIZZUNO <br />VIABIZZUNO <br />ECONOTRACK - E1 <br />BLACK <br />120V <br />20.5'W, 3000K, 92 CRI <br />1 <br />24 <br />E2 <br />BLACK TRACK HEAD, 24 DEGREE OPTICS <br />VIABIZZUNO <br />VIABIZZUNO <br />ECONOTRACK - E2 <br />BLACK <br />120V <br />20.5W, 3000K, 92 CRI <br />1 <br />24 <br />E3 <br />BLACK TRACK HEAD, 31 DEGREE OPTICS <br />VIABIZZUNO <br />VIABIZZUNO <br />ECONOTRACK - E3 <br />BLACK <br />120V <br />20.5W, 3000K, 92 CRI <br />1 <br />24 <br />LAMP, WITH BLACK TRIM BLACK INTERIOR, LED 2 D <br />M2-1 <br />DOWNLIGH I, 24 DEGREE OPTIC <br />VIABIZZUNO <br />VIABIZZUNO <br />MINITRAFFIC- M2 <br />BLACK <br />120V <br />16.8W, 30WK, 92 CRI <br />2 <br />20 <br />2 LAMP, WITH BLACKTRIM BLACK INTERIOR, LED <br />M3-1 <br />DOWNLIGHT, 31 DEGREE OPTIC <br />VIABIZZUNO <br />VIABIZZUNO <br />MINITRAFFIC- M3-1 <br />BLACK <br />120V <br />10W, 3000K, 92 CRI <br />2 <br />20 <br />TRACK, BLACK FINISH, FIELD CUT TO MATCH SIZE <br />ON PLANS, PROVIDE END FEEDS AND CONNECTORS <br />T44 <br />AS REQUIRED <br />VIABIZZUNO <br />VIABIZZUNO <br />ECONOTRACK - T1, T2, T3, T4, T# <br />BLACK <br />120V <br />N/A <br />WHITE, SEMI -RECESSED EXTRUDED ALUMINUM LED <br />EDGE LIT EXITSIGN, RED LETTERS, CEILING <br />X1C <br />MOUNTED, WITH BATTERY <br />CAPITOL LIGHT <br />LIGHTALARMS <br />SPLEDNWRCD (WHITE) <br />WHITE <br />120/277 <br />LED W/UNIT <br />3 <br />REM1 <br />RECESSED EMERGENCY LIGHT <br />CAPITOL LIGHT <br />LIGHTALARMS <br />RPW--PSQ WITH REMOTE CONTROL TEST <br />WHITE <br />1201277 <br />4 LED W/UNI I, 717 LUMENS AT90 MIN <br />1 <br />7 <br />CONTROLS AND LIMITERS <br />1 <br />TRACK CURRENT LIMITER PANEL. THE <br />INDICATES THE AMPACITY OF THE CURRENT <br />CLP-#A <br />LIMITER. SEE PLANS. <br />CAPITOL LIGHT <br />ACUITY/SILVER BULLET <br />T24M-1077UL-6BP-3A1-4A2-8A1-SM <br />STANDARD <br />120 <br />N/A <br />COS <br />CEILING OCCUPANCYSENSOR <br />CAPITOL LIGHT <br />SENSORSWITCH <br />CM-PDT-10 <br />WHITE <br />OS <br />WALLOCCUPANCY SENSOR <br />CAPITOL LIGHT <br />LUTRON <br />MS-A102-WH <br />WHITE <br />NOTES: <br />1. <br />PROVIDE CURRENT LIMITER PANEL AS INDICATED ON PLANS. LOCATE PANEL ADJACENT TO TENANT LINE VOLTAGE PANEL, <br />2. <br />POWERS FIXTURES IN THE EVENT OF A POWER FAILURE. SEE WIRING DETAIL <br />3. <br />PROVIDE 0-10V DIMMER WITH FIXTURE. SEE LIGHTING PLAN FOR QUANTITY. <br />4. <br />INSTALL REMOTE DRIVER ANDO-10V DIMMERTO CONTROL FIXTURE. PROVIDE LOW VOLTAGE WIRING FROM REMOTE DRIVER TO FIXTURE. <br />5. <br />INSTALL REMOTE DRIVER AND LOW VOLTAGE WIRING FROM REMOTE DRIVER TO FIXTURE. <br />6. <br />FIXTURE IS FURNISHED FROM MANUFACTURER WITH 10 METER (32FT) 2 CONDUCTOR, PLENUM RATED SUPPLY. FIXTURE IS SUPPLIED WITH 120V/24V DRIVER, PLENUM RATED, UL LISTED FOR HARD WIRED LINE/LOAD CONNECTIONS. <br />ELECTRICAL CONTRACTOR TO SUPPLY <br />LOW VOLTAGE WIRING BETWEEN DRIVER AND 10M LEAD, OR SHORTEN LEAD WHEN THE DRIVER IS WITHIN 10 M. ELECTRICAL CONTRACTOR TO PROVIDE SUPPORTS <br />AND LINE VOLTAGE WIRING/CONNECTIONS TO DRIVER, AND INSTALL <br />DRIVER. ALL DRIVERS ARE PROVIDE <br />WITH 0-10V DIMMING. ELECTRICAL CONTRACTOR TO PROVIDE 0-10V DIMMER AND DIMMING 2C PLENUM RATED CABLE TO DRIVERS AND CONNECT/TEST. <br />INSTALL DIMMER IN REMOTE LOCATION WHERE SHOWN ON PLANS. <br />7. <br />FIXTURE IS FURNISHED FROM MANUFACTURER WITH 5 METER (15FT) 2 CONDUCI OR, PLENUM RATED SUPPLY. FIXTURE IS SUPPLIED WITH 120V/24V DRIVER, <br />PLENUM RATED, UL LISTED FOR HARD WIRED LINE/LOAD CONNECTIONS. <br />ELECTRICAL CONTRACTOR TO SUPPLY <br />LOW VOLTAGE WIRING BETWEEN DRIVER AND 3M LEAD, OR SHORTEN LEAD WHEN THE DRIVER IS WITHIN 10 M. ELECTRICAL CONTRACTOR TO PROVIDE SUPPORTS AND LINE VOLTAGE WIRING/CONNECTIONS 10 DRIVER, AND INSTALL DRIVER. ALL DRIVERS ARE PROVIDER <br />WITH 0-10V DIMMING. ELECTRICAL CONTRACTOR TO PROVIDE 0-10V DIMMER AND DIMMING 2C PLENUM RATED CABLE TO DRIVERS AND CONNECT/TEST. <br />INS HALL DIMMER AS SHOWN ON DRAWINGS. <br />GENERAL: <br />WHEN THE PROJECT IS LOCATED IN NYC OR CHICAGO, SUPPLIER TO VERIFY PART NUMBERS BEFORE FURNISHING. <br />TENANT'S SUPPLIER TO PROVIDE WALL OCCUPANCY SENSORS, DIMMERS, AND/OR COMBINATION SENSORS/DIMMERS, SEE PLANS FOR EXACT QUANTITY. <br />ONT <br />XX KEYNOTES -LIGHTING PLAN <br />1. CIRCUIT VIA MASTER LIGHTING SWITCH BANK. SEE DETAIL ED033. <br />2. NEW LIGHTING SWITCH BANK. SEE DETAIL ED033. IF LOCATION IS <br />UNDESIRABLE, FIELD VERIFY EXACT LOCATION WITH NEXTORE PROJECT <br />MANAGER PRIOR TO ROUGH -IN. <br />3. ROUTE UNSWITCHED CONNECTION TO EXIT SIGNS AND WHERE FIXTURES <br />ARE SWITCHED, ROUTE ADDITIONAL POWER FROM THE SAME CIRCUIT <br />AHEAD OF ALL SWITCHING FOR POWER LOSS SENSING. <br />4. PROVIDE OCCUPANCY SENSOR FOR AUTOMATIC SHUT OFF OF ROOM <br />LIGHTING. SEE DETAIL E002. <br />5. EXTEND CIRCUITRY TO NEW CEILING MOUNTED RESTROOM EXHAUST FAN IN <br />THIS SPACE. RESTROOM LIGHT SWITCH SHALL SIMULTANEOUSLY CONTROL <br />LIGHTS AND FAN. <br />6. NOT USED. <br />7. CURRENT LIMITING PANEL "CLP". REFER TO LIGHTING FIXTURE SCHEDULE FOR <br />MORE INFORMATION. <br />1. EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE <br />CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. <br />2. ALL NIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING <br />3. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. <br />THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE <br />DISTRIBUTOR. <br />4. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. <br />EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND <br />CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT <br />NEXTORE PROJECT MANAGER FOR DIRECTION. <br />5. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO <br />AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES <br />ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR <br />DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN <br />LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR <br />DIRECTION. <br />6. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY <br />CONSTRUCTION PERIOD. <br />7. LIGHTING CIRCUITS UP TO 100'--0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM, <br />LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS <br />MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS <br />MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS <br />MINIMUM, <br />8. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE <br />T HRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR <br />VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING <br />FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR <br />MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. <br />9. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS <br />FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL <br />DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM <br />G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, G.C. SHALL CALL THE LIGHTING <br />DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE <br />RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH NEXTORE. <br />10. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST <br />NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL -VOLTAGE <br />WITH BATTERY BACKUP (1201277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE <br />USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT <br />ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. <br />11. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE <br />SYSTEM. <br />12. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND <br />MILLWORK PRIOR TO CONNECTION. <br />13. FOR ALL REMODELS, RETROFIT ALL EXISTING FLUORESCENT LIGHTS WITH T12 FIXTURES TO 18, <br />INCLUDING BALLASTS AND LAMPS <br />14. EMERGENCY (FM) LUMINAIRES THAT ARE NOT WIRED TO A CENTRAL INVERTER SYSTEM NOR <br />SHOWN WITH `NU SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS <br />POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. <br />INFORMATION IS BASED ON SURVEY <br />PICTURES. VERIFY ALL WORK IN FIELD. <br />ADVISE NEXTORE PROJECT MANAGER OF <br />ANY DISCREPANCIES, <br />DO NOT INSTALL JUNCTION PDXES (WITH OR WITHOUT COVERS) VISIBLE <br />TO THE PUBLIC IN THE SALES AND PUBLIC PACK OF HOUSE AREAS. IF <br />THIS IS DONE, THE GC IS REQUIRED TO REMOVE THE JUNCTION PDX AT <br />HIS/HER EXPENSE. <br />ENERGY CODE - COMMISSIONING <br />1. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA: <br />1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING. <br />1.2. OCCUPANCY SENSORS DE -ENERGIZE AFTER NO MOTION IS DETECTED AFTER A <br />30 MINUTE DELAY, <br />2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA: <br />2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE <br />ENERGIZED AND DE -ENERGIZED WITH THE TIMER SWITCH OR CONTACTOR <br />CONTROLLED BY TIME LOCK. <br />ER E - COMMISSIONING SMALL <br />PROJECTS <br />CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE <br />CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS <br />THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. <br />RECESSED LIGHT FIXTURES INSTALLED IN A PLENUM SPACE SHALL RE PLENUM RATED. <br />Construction <br />o� <br />ILU �:- V <br />i Associates <br />C O N S U L T I N G <br />PNGIINEEERS <br />3030 West Streetsboro Road <br />Richfield, Ohio 44286 <br />(330) 659-6688 Phone <br />(330) 659-6675 Fax <br />6", <br />15L�Ci1 � <br />Architect Job No.: <br />33N2022 <br />Nextore Store Design Revision No.: <br />briA <br />Nextore Project <br />Number 86841 <br />Brand Design Type: <br />SKIN <br />ISSUED FOR: <br />❑ CONSTRUCTION <br />Title <br />LIGHTING <br />PLAN <br />Date <br />04/19/2022 <br />Drawn By <br />TBA <br />Checked By <br />TBA <br />Sheet <br />