LARGE
<br />EXAM
<br />SMALL
<br />EXAM
<br />O.D.
<br />RECEPTION
<br />ELECTRICAL - LIGHTING
<br />SCALE: 1/4" = 1'-0"
<br />LIGHT FIXTURE SCHEDULE e NEXTORE 2
<br />ALL NEW FIXTURES ARE OWNER SUPPLIED, EC INSTALLED
<br />TAG
<br />DESCRIPTION
<br />SUPPLIER
<br />MANUFACTURER
<br />MODELNUMBER
<br />FINISH/COLORVOLIAGE
<br />LAMP TYPE
<br />LAMP CITY
<br />FIXTURE WATTS
<br />NOTES
<br />A2L
<br />20W RECESSED 2X2 LED PANEL
<br />CREE
<br />C-TR-FP22-25L-35K-WH
<br />2X2 LED PANEL
<br />120V
<br />20W LED
<br />20W LED CHIP, 0-10V DIMMING
<br />1
<br />20
<br />20W RECESSED 2X2 LED PANELW/1320 LUM
<br />A2L-EM
<br />BATTERY
<br />CREE
<br />C-TR-FP22-25L-35K-WH-EB
<br />2X2 LED PANEL
<br />120V
<br />2OW LED
<br />20W LED CHIP, 0-10V DIMMING
<br />1
<br />20
<br />E1
<br />BLACK TRACK HEAD, 15 DEGREE OPTICS
<br />VIABIZZUNO
<br />VIABIZZUNO
<br />ECONOTRACK - E1
<br />BLACK
<br />120V
<br />20.5'W, 3000K, 92 CRI
<br />1
<br />24
<br />E2
<br />BLACK TRACK HEAD, 24 DEGREE OPTICS
<br />VIABIZZUNO
<br />VIABIZZUNO
<br />ECONOTRACK - E2
<br />BLACK
<br />120V
<br />20.5W, 3000K, 92 CRI
<br />1
<br />24
<br />E3
<br />BLACK TRACK HEAD, 31 DEGREE OPTICS
<br />VIABIZZUNO
<br />VIABIZZUNO
<br />ECONOTRACK - E3
<br />BLACK
<br />120V
<br />20.5W, 3000K, 92 CRI
<br />1
<br />24
<br />LAMP, WITH BLACK TRIM BLACK INTERIOR, LED 2 D
<br />M2-1
<br />DOWNLIGH I, 24 DEGREE OPTIC
<br />VIABIZZUNO
<br />VIABIZZUNO
<br />MINITRAFFIC- M2
<br />BLACK
<br />120V
<br />16.8W, 30WK, 92 CRI
<br />2
<br />20
<br />2 LAMP, WITH BLACKTRIM BLACK INTERIOR, LED
<br />M3-1
<br />DOWNLIGHT, 31 DEGREE OPTIC
<br />VIABIZZUNO
<br />VIABIZZUNO
<br />MINITRAFFIC- M3-1
<br />BLACK
<br />120V
<br />10W, 3000K, 92 CRI
<br />2
<br />20
<br />TRACK, BLACK FINISH, FIELD CUT TO MATCH SIZE
<br />ON PLANS, PROVIDE END FEEDS AND CONNECTORS
<br />T44
<br />AS REQUIRED
<br />VIABIZZUNO
<br />VIABIZZUNO
<br />ECONOTRACK - T1, T2, T3, T4, T#
<br />BLACK
<br />120V
<br />N/A
<br />WHITE, SEMI -RECESSED EXTRUDED ALUMINUM LED
<br />EDGE LIT EXITSIGN, RED LETTERS, CEILING
<br />X1C
<br />MOUNTED, WITH BATTERY
<br />CAPITOL LIGHT
<br />LIGHTALARMS
<br />SPLEDNWRCD (WHITE)
<br />WHITE
<br />120/277
<br />LED W/UNIT
<br />3
<br />REM1
<br />RECESSED EMERGENCY LIGHT
<br />CAPITOL LIGHT
<br />LIGHTALARMS
<br />RPW--PSQ WITH REMOTE CONTROL TEST
<br />WHITE
<br />1201277
<br />4 LED W/UNI I, 717 LUMENS AT90 MIN
<br />1
<br />7
<br />CONTROLS AND LIMITERS
<br />1
<br />TRACK CURRENT LIMITER PANEL. THE
<br />INDICATES THE AMPACITY OF THE CURRENT
<br />CLP-#A
<br />LIMITER. SEE PLANS.
<br />CAPITOL LIGHT
<br />ACUITY/SILVER BULLET
<br />T24M-1077UL-6BP-3A1-4A2-8A1-SM
<br />STANDARD
<br />120
<br />N/A
<br />COS
<br />CEILING OCCUPANCYSENSOR
<br />CAPITOL LIGHT
<br />SENSORSWITCH
<br />CM-PDT-10
<br />WHITE
<br />OS
<br />WALLOCCUPANCY SENSOR
<br />CAPITOL LIGHT
<br />LUTRON
<br />MS-A102-WH
<br />WHITE
<br />NOTES:
<br />1.
<br />PROVIDE CURRENT LIMITER PANEL AS INDICATED ON PLANS. LOCATE PANEL ADJACENT TO TENANT LINE VOLTAGE PANEL,
<br />2.
<br />POWERS FIXTURES IN THE EVENT OF A POWER FAILURE. SEE WIRING DETAIL
<br />3.
<br />PROVIDE 0-10V DIMMER WITH FIXTURE. SEE LIGHTING PLAN FOR QUANTITY.
<br />4.
<br />INSTALL REMOTE DRIVER ANDO-10V DIMMERTO CONTROL FIXTURE. PROVIDE LOW VOLTAGE WIRING FROM REMOTE DRIVER TO FIXTURE.
<br />5.
<br />INSTALL REMOTE DRIVER AND LOW VOLTAGE WIRING FROM REMOTE DRIVER TO FIXTURE.
<br />6.
<br />FIXTURE IS FURNISHED FROM MANUFACTURER WITH 10 METER (32FT) 2 CONDUCTOR, PLENUM RATED SUPPLY. FIXTURE IS SUPPLIED WITH 120V/24V DRIVER, PLENUM RATED, UL LISTED FOR HARD WIRED LINE/LOAD CONNECTIONS.
<br />ELECTRICAL CONTRACTOR TO SUPPLY
<br />LOW VOLTAGE WIRING BETWEEN DRIVER AND 10M LEAD, OR SHORTEN LEAD WHEN THE DRIVER IS WITHIN 10 M. ELECTRICAL CONTRACTOR TO PROVIDE SUPPORTS
<br />AND LINE VOLTAGE WIRING/CONNECTIONS TO DRIVER, AND INSTALL
<br />DRIVER. ALL DRIVERS ARE PROVIDE
<br />WITH 0-10V DIMMING. ELECTRICAL CONTRACTOR TO PROVIDE 0-10V DIMMER AND DIMMING 2C PLENUM RATED CABLE TO DRIVERS AND CONNECT/TEST.
<br />INSTALL DIMMER IN REMOTE LOCATION WHERE SHOWN ON PLANS.
<br />7.
<br />FIXTURE IS FURNISHED FROM MANUFACTURER WITH 5 METER (15FT) 2 CONDUCI OR, PLENUM RATED SUPPLY. FIXTURE IS SUPPLIED WITH 120V/24V DRIVER,
<br />PLENUM RATED, UL LISTED FOR HARD WIRED LINE/LOAD CONNECTIONS.
<br />ELECTRICAL CONTRACTOR TO SUPPLY
<br />LOW VOLTAGE WIRING BETWEEN DRIVER AND 3M LEAD, OR SHORTEN LEAD WHEN THE DRIVER IS WITHIN 10 M. ELECTRICAL CONTRACTOR TO PROVIDE SUPPORTS AND LINE VOLTAGE WIRING/CONNECTIONS 10 DRIVER, AND INSTALL DRIVER. ALL DRIVERS ARE PROVIDER
<br />WITH 0-10V DIMMING. ELECTRICAL CONTRACTOR TO PROVIDE 0-10V DIMMER AND DIMMING 2C PLENUM RATED CABLE TO DRIVERS AND CONNECT/TEST.
<br />INS HALL DIMMER AS SHOWN ON DRAWINGS.
<br />GENERAL:
<br />WHEN THE PROJECT IS LOCATED IN NYC OR CHICAGO, SUPPLIER TO VERIFY PART NUMBERS BEFORE FURNISHING.
<br />TENANT'S SUPPLIER TO PROVIDE WALL OCCUPANCY SENSORS, DIMMERS, AND/OR COMBINATION SENSORS/DIMMERS, SEE PLANS FOR EXACT QUANTITY.
<br />ONT
<br />XX KEYNOTES -LIGHTING PLAN
<br />1. CIRCUIT VIA MASTER LIGHTING SWITCH BANK. SEE DETAIL ED033.
<br />2. NEW LIGHTING SWITCH BANK. SEE DETAIL ED033. IF LOCATION IS
<br />UNDESIRABLE, FIELD VERIFY EXACT LOCATION WITH NEXTORE PROJECT
<br />MANAGER PRIOR TO ROUGH -IN.
<br />3. ROUTE UNSWITCHED CONNECTION TO EXIT SIGNS AND WHERE FIXTURES
<br />ARE SWITCHED, ROUTE ADDITIONAL POWER FROM THE SAME CIRCUIT
<br />AHEAD OF ALL SWITCHING FOR POWER LOSS SENSING.
<br />4. PROVIDE OCCUPANCY SENSOR FOR AUTOMATIC SHUT OFF OF ROOM
<br />LIGHTING. SEE DETAIL E002.
<br />5. EXTEND CIRCUITRY TO NEW CEILING MOUNTED RESTROOM EXHAUST FAN IN
<br />THIS SPACE. RESTROOM LIGHT SWITCH SHALL SIMULTANEOUSLY CONTROL
<br />LIGHTS AND FAN.
<br />6. NOT USED.
<br />7. CURRENT LIMITING PANEL "CLP". REFER TO LIGHTING FIXTURE SCHEDULE FOR
<br />MORE INFORMATION.
<br />1. EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE
<br />CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF.
<br />2. ALL NIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING
<br />3. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE.
<br />THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE
<br />DISTRIBUTOR.
<br />4. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS.
<br />EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND
<br />CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT
<br />NEXTORE PROJECT MANAGER FOR DIRECTION.
<br />5. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO
<br />AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES
<br />ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR
<br />DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN
<br />LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR
<br />DIRECTION.
<br />6. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY
<br />CONSTRUCTION PERIOD.
<br />7. LIGHTING CIRCUITS UP TO 100'--0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM,
<br />LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS
<br />MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS
<br />MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS
<br />MINIMUM,
<br />8. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE
<br />T HRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR
<br />VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING
<br />FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR
<br />MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID.
<br />9. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS
<br />FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL
<br />DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM
<br />G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, G.C. SHALL CALL THE LIGHTING
<br />DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE
<br />RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH NEXTORE.
<br />10. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST
<br />NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL -VOLTAGE
<br />WITH BATTERY BACKUP (1201277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE
<br />USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT
<br />ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION.
<br />11. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE
<br />SYSTEM.
<br />12. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND
<br />MILLWORK PRIOR TO CONNECTION.
<br />13. FOR ALL REMODELS, RETROFIT ALL EXISTING FLUORESCENT LIGHTS WITH T12 FIXTURES TO 18,
<br />INCLUDING BALLASTS AND LAMPS
<br />14. EMERGENCY (FM) LUMINAIRES THAT ARE NOT WIRED TO A CENTRAL INVERTER SYSTEM NOR
<br />SHOWN WITH `NU SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS
<br />POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF.
<br />INFORMATION IS BASED ON SURVEY
<br />PICTURES. VERIFY ALL WORK IN FIELD.
<br />ADVISE NEXTORE PROJECT MANAGER OF
<br />ANY DISCREPANCIES,
<br />DO NOT INSTALL JUNCTION PDXES (WITH OR WITHOUT COVERS) VISIBLE
<br />TO THE PUBLIC IN THE SALES AND PUBLIC PACK OF HOUSE AREAS. IF
<br />THIS IS DONE, THE GC IS REQUIRED TO REMOVE THE JUNCTION PDX AT
<br />HIS/HER EXPENSE.
<br />ENERGY CODE - COMMISSIONING
<br />1. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA:
<br />1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING.
<br />1.2. OCCUPANCY SENSORS DE -ENERGIZE AFTER NO MOTION IS DETECTED AFTER A
<br />30 MINUTE DELAY,
<br />2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA:
<br />2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE
<br />ENERGIZED AND DE -ENERGIZED WITH THE TIMER SWITCH OR CONTACTOR
<br />CONTROLLED BY TIME LOCK.
<br />ER E - COMMISSIONING SMALL
<br />PROJECTS
<br />CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE
<br />CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS
<br />THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT.
<br />RECESSED LIGHT FIXTURES INSTALLED IN A PLENUM SPACE SHALL RE PLENUM RATED.
<br />Construction
<br />o�
<br />ILU �:- V
<br />i Associates
<br />C O N S U L T I N G
<br />PNGIINEEERS
<br />3030 West Streetsboro Road
<br />Richfield, Ohio 44286
<br />(330) 659-6688 Phone
<br />(330) 659-6675 Fax
<br />6",
<br />15L�Ci1 �
<br />Architect Job No.:
<br />33N2022
<br />Nextore Store Design Revision No.:
<br />briA
<br />Nextore Project
<br />Number 86841
<br />Brand Design Type:
<br />SKIN
<br />ISSUED FOR:
<br />❑ CONSTRUCTION
<br />Title
<br />LIGHTING
<br />PLAN
<br />Date
<br />04/19/2022
<br />Drawn By
<br />TBA
<br />Checked By
<br />TBA